INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED ROYAL EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS ROUGH-IN

Similar documents
INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

Reducing Your Water Footprint

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR SOLIS SOLAR-POWERED SENSOR-ACTIVATED CONCEALED FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Maintenance Guide. OPTIMA Components:

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

G2 Optima Plus Flushometer

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

ETF-600 Sensor Operated Lavatory Faucet

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM ROYAL AND REGAL XL CONCEALED CLOSET AND URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

Optima Flushometers Current style Royal (after 09/26/10)

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

AquaSense ZTR Series

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Royal Flushometer PARTS LIST

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

AquaSense ZTR Series

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

Installation Instructions

AquaSense TM ZTS6200EV Series

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

Installation Instructions

Installation Instructions

AquaSense AV Closet ZEMS Series Automatic Systems Sensor-Operated AquaVantage Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaSense TM ZEG Series

AquaSense AV ZER Series

Installation Instructions

Sloan Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 6. SLIP JOINT GASKETS AND RINGS

Installation Instructions

Installation Instructions

Installation Instructions

AquaSense AV ZER Series

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Installation Instructions

Installation Instructions

AquaSense ZTR Series

Installation Instructions

AquaVantage AV ZER6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

FUEL SYSTEM. Table of Contents. Specifications. Special Tools. Section 3B Carburetor. 950 ± 50 rpm 850 ± 50 rpm

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Instructions

FUEL SYSTEMS 5 A FUEL DELIVERY SYSTEMS AND FUEL PUMPS

INSTALLATION INSTRUCTIONS FOR SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM EXPOSED CLOSET, URINAL AND SERVICE SINK

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

Sloan & Zurn Flush Valves

COMMANDER 3000 CLASSIC PANEL MOUNT REMOTE CONTROL

2 ½ 4 Deringer 40/50 Maintenance Instructions READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 8:00 AM 4:30 PM PST

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

ACCESSORIES. Table of Contents. Section 8A - All Models

TABLE OF CONTENTS Flushometer Section

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

6 8 Magnum 40(x) Maintenance Instructions

Model 1001/1001HPS Drinking Fountain

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual

Sensor-Operated Exposed Systems ZEMS6200 ZEMS ZEMS ZEMS6201 ZEMS6203

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

GENUINE REPAIR PARTS FOR

AquaSense ZEMS G2 Series

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

Transcription:

ode No. 0816434 Rev. 8 (08/14) INSTLLTION INSTRUTIONS FOR OPTIM SYSTEM SENSOR TIVTE ROYL EXPOSE WITH TRUE MEHNIL OVERRIE FLUSHOMETERS Exposed loset Flushometers 1-1/2 Top Spud Model 110/111 ES-S TMO Model 113 ES-S TMO Model 115 ES-S TMO Model 116 ES-S TMO Exposed Urinal Flushometers 3/4 Top Spud Model 186 ES-S TMO Exposed Urinal Flushometers 1-1/4 Top Spud Model 180 ES-S TMO MOEL 110/111 MOEL 186 MOEL 180 LIMITE WRRNTY Unless otherwise noted, Sloan Valve ompany warrants its products, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. uring this period, Sloan Valve ompany will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve ompany, at customer s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve ompany s products directly from Sloan Valve ompany for purpose of resale. This warranty does not cover the life of the batteries. THERE RE NO WRRNTIES WHIH EXTEN EYON THE ESRIPTION ON THE FE HEREOF. IN NO EVENT IS SLON VLVE OMPNY RESPONSILE FOR NY ONSEQUENTIL MGES OF NY MESURE WHTSOEVER. ROUGH-IN MOEL 110/111/113 MOEL 186 2-1/4 (57 mm) 2-3/4 1-1/2 (38 mm) 1 I.P.S. (25 mm N) 2-1/4 (57 mm) ELE. 2-3/4 1-1/2 (38 mm) 3/4 I.P.S. (20 mm N) T.M.O. TOP OF ELE. OX & X MOEL 110/111-11½ (292 mm) Y MOEL 110/111-19 (356 mm) MOEL 113-16 (406 mm) MOEL 113-19 (483 mm) MOEL 115/116 X Y MOEL 180 4 (102 mm) TOP OF T.M.O. 11-1/2 (292 mm) 1-1/2 (38 mm) 2-1/4 (57 mm) 2-3/4 1-1/2 (38 mm) OVERRIE SENSOR PLTE ELETRIL OX TOP OF Y 1 I.P.S. (25 mm N) X MOEL 115-24 (610 mm) Y MOEL 115-14 (356 mm) MOEL 116-27 (686 mm) MOEL 116-17 (432 mm) POSITION OF SENSOR OX N E RISE OR LOWERE 1 (25 mm) IF IN ONFLIT WITH HNIP GR RS. X 2-1/4 (57 mm) 4 (102 mm) ELE. 2-3/4 1-1/2 (38 mm) TOP OF 1 I.P.S. (25 mm N) T.M.O. 11-1/2 (292 mm) 1-1/2 (38 mm)

PRIOR TO INSTLLTION Prior to installation, install the items listed below. Electrical wiring to the transformer loset fixture box (120 V, 2 amp service required Water supply line for each EL-154, 24 V, rain line 50 V transformer used) IMPORTNT: LL PLUMINGING N ELETRIL WIRING SHOUL E INSTLLE IN ORNE WITH PPLILE OES N REGULTIONS. WTER LINES MUST E SIZE TO PROVIE N EQUTE VOLUME OF WTER FOR EH. 24 V STEP-OWN TRNSFORMER MUST E USE. WHEN INSTLLING FLUSHOMETER, IT IS IMPORTNT THT THE FLUSH MOEL MTHES THE REQUIREMENTS OF THE PLUMING. FLUSH LL WTER LINES PRIOR TO MKING ONNETIONS. Sloan flushometers are designed to operate with flowing pressure 15 to 100 psi (104 to 689 kpa) of water pressure. THE MINIMUM PRESSURE REQUIRE TO THE VLVE IS ETERMINE Y THE TYPE OF SELETE. onsult fixture manufacturer for minimum pressure requirements. Most Low onsumption water closets (1.6 gpf/6.0 Lpf) require a minimum flowing pressure of 25 psi (172 kpa). Protect the chrome or special finish of this flushometer O NOT USE TOOTHE TOOLS TO INSTLL OR SERVIE THE VLVE. lso, see are and leaning section of this manual. IMPORTNT: EXEPT FOR ONTROL STOP INLET, O NOT USE PIPE SELNT OR PLUMING GRESE ON NY VLVE OMPONENT OR OUPLING! ELETRIL OX INSTLLTION IGRM FINISHE TILE WLL 4 (102 mm) SQ. OX EVIE OVER (PLSTER RING) 3/4 (19 mm) HIGH PPLETON ELET. #8470 OR EQUL (Y ONTRTOR) Transformer Installation Install transformer (EL-154) on a 2-gang electrical box, 4 x 4 x 2½ (102 mm x 102 mm x 64 mm) in a convenient location; refer to the illustration at lower left side of this page (Figure 1). Note: One Sloan EL-154 transformer can operate up to ten Optima equipped flushometers. Run 18-gauge wire from transformer to flushometer(s). Wire supplied by others. O NOT supply power to transformer until installation of flushometer is complete. NOTE: maximum of ten (10) flushometer units can operate from one (1) Sloan EL-154 transformer, lass 2, UL Listed, 50 V (min.) at 24 V, plate mounted. Sensor/Solenoid Operator ox Locations Optima ES-S flushometer exposed True Mechanical Override closet model employs one (1) electrical box. Refer to rough-in illustrations for locations. NOTE: Install plaster ring so screw holes are on left and right side of box. NOTE: reak tiles to allow screw holes in plaster to show. Tools Required for Installation Sloan -50 Super-Wrench, Wire stripper/crimping tool Sloan -109 Plier Wrench or 5/64 hex wrench (supplied) smooth jawed spud wrench Slotted screwdriver!!! IMPORTNT!!! WITH THE EXEPTION OF ONTROL STOP INLET, O NOT USE PIPE SELNT OR PLUMING GRESE ON NY VLVE OMPONENT OR OUPLING!!!! IMPORTNT!!! NEVER OPEN ONTROL STOP TO WHERE THE FLOW FROM THE VLVE EXEES THE FLOW PILITY OF THE. IN THE EVENT OF VLVE FILURE, THE MUST E LE TO OMMOTE ONTINUOUS FLOW FROM THE VLVE. OVER PLTE!!! IMPORTNT!!! PROTET THE FINISH OF SLON S FLUSHOMETERS O NOT USE TOOTHE TOOLS TO INSTLL OR SERVIE THESE VLVES. USE SLON -50 Super-Wrench, Sloan -109 Plier Wrench OR SMOOTH JWE WRENH TO SEURE LL OUPLINGS. LSO SEE THE RE N LENING SETION.!!! IMPORTNT!!! THIS PROUT ONTINS MEHNIL N/OR ELETRIL OMPONENTS THT RE SUJET TO NORML WER. THESE OMPONENTS SHOUL E HEKE ON REGULR SIS N REPLE S NEEE TO MINTIN THE VLVE S PERFORMNE. g Orientation PLSTER RING FINISHE PLSTER WLL 4 (102 mm) SQ. x 2-1/2 (64 mm) EEP OUTLET OX PPLETON ELET. #4S1 OR EQUL (Y ONTRTOR) Figure 1 1 - INSTLL OPTIONL SWET SOLER PTER (ONLY IF YOUR PIPE OES NOT HVE MLE THRE) Measure from finished wall to /L of fixture spud. ut pipe 1¼ (32 mm) shorter than this measurement. hamfer O.. and I.. of water supply pipe. Slide threaded adapter fully onto pipe, until it bottoms out. WTER PIPE FINISHE WLL 1-1/4 (32 mm) Sweat solder the adapter to pipe.!!! IMPORTNT!!! WITH THE EXEPTION OF ONTROL STOP INLET, O NOT USE PIPE SELNT OR PLUMING GRESE ON NY VLVE OMPONENT OR OUPLING! 2 /L OF SWET SOLER PTER

2 - INSTLL OVER TUE, WLL FLNGE N ONTROL STOP TO PIPE Measure from finished wall to first thread of adapter or threaded supply pipe (dimension X ). ut cover tube to this length. Slide cover tube over pipe. Slide wall flange over cover tube until against wall. Thread control stop onto water supply line. Tighten with a wrench making sure outlet is positioned as required. Tighten wall flange set screw with hex wrench. O NOT install vandal resistant stop cap at this time. WLL FLNGE IRON PIPE NIPPLE OR OPPER PIPE WITH SWET SOLER PTER OVERING TUE WTER PIPE X SWET SOLER PTER OVER TUE K-HEK STOP SET SREW ONNET ONTROL STOP P SET SREW WLL FLNGE 3 INSTLL VUUM REKER FLUSH ONNETION N UTTON ssemble pipe, elbows, couplings, nylon slip gaskets, rubber gaskets and flanges as illustrated. Insert tube into fixture spud. E Install true mechanical override button into flushometer. Install valve handle cap on opening in back of valve body. Hand tighten all couplings. VUUM REKER TUE VUUM REKER TUE VUUM REKER TUE Flushometer -6 oupling Nut NYLON SLIP GSKET FLNGE OUPLING RUER GSKET NYLON SLIP GSKET FLNGE OUPLING RUER GSKET NYLON SLIP GSKET FLNGE OUPLING RUER GSKET EV-1017- Valve Handle ap -31 Gasket True Mechanical Override utton ssembly 4 - INSTLL FLUSHOMETER NOTE For high efficiency urinal flushometers (0.5, 0.25 and 0.125 gpf), it is necessary to first insert the flow control component into the tailpiece assembly. See the H1015 flow control kit and separate instructions for details on how to install. FLUSHOMETER OY TILPIEE OUPLING O-RING 1 ONTROL STOP Lubricate tailpiece o-ring with water. Insert adjustable tailpiece into control stop. Tighten tailpiece coupling by hand. G-44 FRITION RING JUSTLE TILPIEE lign flushometer directly above the vacuum breaker flush connection by sliding the flushometer body IN or OUT as needed. Tighten vacuum breaker coupling by hand. lign flushometer body and securely tighten first the tailpiece coupling (1), then the vacuum breaker and pipe couplings (2), and finally the spud coupling (3). Use a wrench to tighten these couplings in the order shown. NOTE Max. adjustment of Sloan djustable Tailpiece is ½ (13 mm) IN or OUT from the standard 4¾ ( L of Valve to L of ontrol Stop). If roughing-in measurement exceeds 5¼ (133 mm), consult factory for longer tailpiece. 2 3 VUUM REKER OUPLING VUUM REKER FINISH ONNETION OUPLING VUUM REKER REPIR KIT ± 1/2 (13 mm) 3

6 - INSTLL SENSOR OX MOUNTING PLTE Install Sensor Mounting Plate using the Screws provided. SENSOR OX MOUNTING PLTE SENSOR MOUNTING PLTE TTH SENSOR MOUNTING PLTE TO PLSTER RING USING FOUR (4) SREWS (SUPPLIE) LT. MOUNTING HOLES IF MU RING IS INSTLLE WITH HOLES ORIENTE TOP/OTTOM Preferred Plaster Ring Orientation 7 - ELETRIL HOOK-UP e certain power is OFF to prevent damage to electrical components. onnect Sensor to Transformer and Solenoid coil EXTLY as shown. Wiring iagram for One Flush Valve onnect 24 volt source lead to terminal labeled 24 V IN of Sensor. TRNSFORMER SENSOR onnect solenoid lead to terminal labeled TO VLVE of Sensor. onnect remaining solenoid lead to remaining 24 volt source lead. Wiring iagram 120 V GR SOLENOI VLVE EL-1500-L SENSOR 24 V Wiring iagram for Multiple Flush Valves OIL WIRE 24 V OIL UNIT #1 EL-1500-L SENSOR OIL WIRE 24 V OIL UNIT #2 THRU #10 (IF USE) TRNSFORMER 8 - INSTLL SENSOR OVER PLTE Hang Sensor over Plate onto Mounting Plate. Push down on over Plate to firmly seat. Secure over Plate with Screw, provided. SENSOR OX OVER PLTE SSEMLY K VIEW OVER PLTE SSEMLY WILL HNG ON MOUNTING PLTE (3) PLES FRONT VIEW TO 24 V POWER IN SENSOR RKET (EL-545) TO VLVE FTER PLTE SSEMLY IS HUNG ON WLL, TURN SREW IN FULL ISTNE S SHOWN 4

9 - INSTLL WLL FLNGE N SEURE SOLENOI HOUSING N OIL SSEMLY Locate flange on wall at dimensions shown. FLNGE F G H onnect transformer and sensor wire leads to coil wire leads. Lubricate O-Ring seal of solenoid assembly with water. While feeding wires back into the wall, carefully insert the F-15 tail into the wall flange and install solenoid operator assembly to Flushometer. Loosen the housing retention nut as needed to aid in positioning the assembly. SET SREW ELETRIL WIRING 2-3/4 rill hole to pass wires through. Mount flange to wall using screws and anchors provided. E Pull wires from transformer and sensor through flange into room. Install F-15 Tail Pipe to Solenoid Housing. F-15 oil Retention Nut I J Secure solenoid operator to Flushometer by tightening the solenoid coupling. Tighten housing retention nut. Secure flange set screw with provided hex key. Important: o not remove coil from solenoid plunger guide unless power has been disconnected. Failure to do so may damage sensor, coil and transformer. 10 - FLUSH OUT LINE E Make sure control stop is LOSE. Remove flushometer outer cover, inside cover and lift out relief valve assembly. Install flushometer inner cover and outer cover, and wrench tight. Open control stop. Turn on water supply to flush line of any debris or sediment. Shut off control stop, remove covers, remove diaphragm kit and flush under clean water. Reinstall diaphragm kit and relief valve assembly. Reinstall inside cover. Thread on outer cover and wrench tight. O NOT open control stop until Step 13. 5

11 - POWER N STRT-UP MOE Note: It is recommended that all electronic connections be tested with the water supply OFF. Turn Power ON. The self-adaptive sensor automatically adapts to the surrounding environment when 24 volt supply is activated. No manual adjustments are required. Start-up mode will take approximately one (1) minute to complete its cycle and is important that no non-permanent target is present at this time. continuous red light visible in sensor window indicates sensor is in the start-up mode. If the red light is flashing, this indicates that the sensor is picking up a target. Unless this target is a permanent fixture in the sensor s environment (i.e., a wall or stall door), it must be removed from the view of the sensor. In this case, disconnect the 24 volt power supply for twenty (20) seconds or more. Reconnect the 24 volt power supply at the transformer or fuse box. When start-up cycle is complete, there will be no light visible in the sensor window. Note: If 24 volt power supply is interrupted at any time for more than fifteen (15) seconds, the start-up mode automatically repeats itself when power is restored. Incorrect wiring or a short in the 24 volt supply is indicated by a continuous warning signal seen in the sensor window. The visible red light flashes three (3) slow, three (3) times fast, three (3) slow flashes. The EL-1500 Series Sensors self-adaptive sensor is equipped with the sentinel flush feature (automatically flushes Flushometer every twenty-four (24) hours after last use). 12 - ETETION / TIVTION When an object is detected, a slowly flashing red light will appear in the sensor window. fter approximately eight (8) to ten (10) seconds, the light will flash rapidly indicating sensor is armed and ready to activate solenoid when the object leaves the detection area. The solenoid will be activated within two (2) to four (4) seconds after nondetection. 13 - TURN WTER ON N JUST ONTROL STOP djust control stop to meet the flow rate required for proper cleansing of the fixture. Open control stop OUNTERLOKWISE one (1) FULL turn from the closed position. ctivate flushometer by placing hand in front of Optima sensor lens for ten (10) seconds and then moving it away. djust control stop after each flush until the rate of flow delivered properly cleanses the fixture.!!! IMPORTNT!!! ll Sloan Flushometers are engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip N a quiet flushing cycle is achieved. Never open ontrol Stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve. 14 - VNL RESISTNT ONTROL STOP P INSTLLTION N REMOVL Thread the plastic sleeve onto the stop bonnet until it is snug (hand tight only; do not use pliers or a wrench). Place the metal control stop cap over the plastic sleeve and using the palm of the hand, push or pop the cap over the fingers of the sleeve. The cap should spin freely on the insert. To remove Vandal Resistant Stop cap Using a large flat screwdriver, gently lift the cap from the control stop as follows. Insert the screwdriver blade between the bottom edge of the cap and the flat surface of the control stop body. Using the screwdriver as a lever, push the screwdriver handle straight back toward the wall. Gently lift the cap from the sleeve. It may be necessary to work the screwdriver around the diameter of the cap to further lift the cap from the sleeve.!!! IMPORTNT!!! O NOT INSTLL THE P ONTO THE SLEEVE UNLESS SLEEVE HS EEN THREE ONTO THE ONTROL STOP ONNET. IF SSEMLE WHEN OFF OF THE ONTROL STOP, THE SLEEVE WILL NOT OME PRT FROM THE P! Once the cap has been lifted away from the control stop, grasp the cap and pull it off the sleeve. 6

OPERTION 1. continuous, invisible light beam is emitted from the Optima sensor. 2. When a user enters the beam s effective range, for water closets 22-42 (559 mm - 1067 mm) and for urinals 15-30 (381 mm - 762 mm), the beam is reflected into the Optima scanning window and transformed into a low voltage electrical signal that activates a ten-second time delay circuit. The time delay circuit eliminates false operation from passers-by in the rest room. Once the time delay is completed, the output circuit is alerted and continues in a hold mode for as long as the user remains within the effective range of the sensor. 3. When the user steps away from the Optima sensor, the loss of reflected light initiates an electrical one-time signal that energizes the solenoid operator, and activates the flushometer to flush the fixture. This occurs on the water closet approximately three (3) seconds after indication. This delay is built into the sensor to help prevent false flushing due to movement by the user. The circuit for both water closets and urinals then automatically resets and is ready for the next user. TROULESHOOTING GUIE NOTE: URINLS When the sensor detects a user, a slow flashing red light appears in the sensor window. fter eight (8) to ten (10) seconds, the light flashes rapidly to indicate that the sensor is armed. When the sensor no longer detects a user, the sensor immediately activates the solenoid valve after a 0.5 second delay. WTER LOSETS etection and activation are the same as the urinal except when the sensor no longer detects an user, the sensor activates the solenoid valve after a three (3) second delay. 1. PROLEM: Valve OES NOT function (red light does not flash when user steps in front of sensor). USE: No power is being supplied to sensor. SOLUTION: Ensure that the main power is turned ON. heck transformer, leads and connections. Repair or replace as necessary. USE: EL-1500 series sensor is not operating. SOLUTION: Replace EL-1500 series sensor. 2. PROLEM: Valve OES NOT function (red light flashes when user steps in front of sensor). INITOR: Red light stops flashing when user steps away and valve makes a clicking sound but OES NOT flush. USE: No water is being supplied to the valve. SOLUTION: Make certain that water supply is turned ON and the control stop is open. USE: EL-128- cartridge is fouled or jammed. SOLUTION: Turn electronic power to valve OFF (failure to do so could result in damage to the solenoid coil). Remove the solenoid operator from the valve and remove the EL-128- cartridge. lean and/or repair as necessary. INITOR: The red light stops flashing when user steps away but the valve OES NOT make a clicking sound and OES NOT flush. USE: EL-163- solenoid shaft assembly is fouled or jammed. SOLUTION: Turn electronic power to valve OFF (failure to do so could result in damage to the solenoid coil). Remove EL-101 or EL-166 nut from the solenoid operator. Remove the coil from the solenoid operator. Use a spanner wrench or pliers to remove the EL-163- solenoid shaft assembly from valve. lean and/or replace as necessary. e sure to replace plunger spring when reassembling solenoid shaft assembly. INITOR: The red light flashes three (3) short flashes, three (3) long flashes then three (3) short flashes ( S-O-S ) and continues to repeat this cycle even when user steps out of the sensor s detection range. USE: SOLUTION: EL-1500 Series sensor wiring connections are incorrect. Rewire sensor to valve. One solenoid lead connects to the TO VLVE connection on sensor. One transformer lead connects to the 24 V IN connection on sensor. Second solenoid lead and second transformer lead connect together. RE N LENING 7 USE: Wiring to sensor is ground shorted. SOLUTION: Find short in wiring circuit and correct. USE: EL-165-2 solenoid coil is burnt out or coil is not connected to solenoid plunger shaft. SOLUTION: Reinstall or replace coil as necessary. 3. PROLEM: Volume of water is insufficient to adequately siphon fixture. USE: ontrol stop is not open wide enough. SOLUTION: djust control stop for desired water delivery. USE: Low consumption unit is installed on water saver or conventional fixture. SOLUTION: Replace diaphragm component parts of valve with kit that corresponds to appropriate flush volume of fixture. USE: Inadequate water volume or pressure available from supply. SOLUTION: Increase pressure or supply (flow rate) to the valve. onsult factory for assistance. 4. PROLEM: Length of flush is too long (long flushing) or valve fails to shut off. USE: Water saver valve is installed on low consumption fixture. SOLUTION: Replace iaphragm component parts of valve with kit that corresponds to appropriate flush volume of fixture. USE: Relief valve in diaphragm is not seated properly or bypass hole in diaphragm is clogged. SOLUTION: isassemble inside iaphragm component parts and wash parts thoroughly. Replace worn parts if necessary. 5. PROLEM: Water splashes from fixture. USE: Supply flow rate is more than necessary. SOLUTION: djust control stop to meet flow rate required for proper cleansing of the fixture. When further assistance is required, please contact Sloan Technical Support at: 1-888-SLON-14 (1-888-756-2614) or visit us online at: www.sloanvalve.com!!! IMPORTNT!!! LWS N REGULTIONS PROHIIT THE USE OF HIGHER FLUSHING VOLUMES THN LISTE ON OR FLUSHOMETER. O NOT USE abrasive or chemical cleaners to clean flushometers or sensor window that may dull the luster and attack the chrome or special decorative finishes of flushometer components. Use ONLY soap and water, then wipe dry with clean cloth or towel. While cleaning the fixture, protect the exposed flushometer from any splattering of cleaner. cids and cleaning fluids can discolor or remove chrome plating.

PRTS LIST 4 10/10 13 4 2 3 9/9 8 7 1 5 5 5 11 (See part breakdown below) Solenoid reakdown 11 11 11F 11E 12 11G 11H 11J 11K 6 6 6 11 11 Item Part No. No. escription 1 Solenoid Operated Valve ssembly 2 H-700- ak-hek ontrol Stop 3 H-1010- Vandal Resistant Stop ap 4 H-633-1 (25 mm) Sweat Solder Kit 4 H-532 dapter, 1 NPT to 1 Tube (oncealed) H-535 dapter, ¾ NPT to ¾ Tube (oncealed) 5 V-600-1½ (38 mm) P Vacuum reaker ssembly (Models 110/111, 113, 115, and 116) 5 V-600-1¼ (32 mm) x 9 (229 mm) P Vacuum reaker ssembly (Model 180 ES-S) 5 V-600- ¾ (19 mm) x 9 (229 mm) P Vacuum reaker ssembly (Model 186 ES-S) 6 F-5-T 1½ (38 mm) Spud oupling ssembly P (Models 110/111, 113, 115, and 116) 6 F-5-U 1¼ (32 mm) Spud oupling ssembly P (Model 180) 6 F-5-W ¾ (19 mm) Spud oupling ssembly P (Model 186) 7 F-15 Tail ssembly 8-110- Flange ssembly 9 EL-635- P over Plate with Sensor (Mounting Plate and Screws included) (Models 110/111, 113, 115, and 116) 9 EL-645- P over Plate with Sensor (Mounting Plate and Screws included) (Models 180 and 186) 10 EL-1500-L Sensor (Models 110/111, 113, 115, and 116) 10 EL-1500 Sensor (Models 180 and 186) Item Part escription No. No. 11 EL-124-2 P 24V Solenoid ssembly 11 EL-101 P Nut for Solenoid 11 EL-102-2 Face Plate for 24V Solenoid 11 EL-162-2 P 24V Solenoid Housing 11 EL-165-2 24V oil 11E EL-164 Solenoid Flux Plate 11F -6 P Handle oupling 11G EL-163- Solenoid Shaft ssembly Includes Gasket, Plunger, Plunger Spring, and Solenoid Shaft 11H EL-104 dapter for Solenoid 11J O-22 O-Ring 11K EL-128- ctuator artridge ssembly Repair Kit Includes Spring, Plunger Guide, Solenoid Valve Seat, Valve Piston ssembly, and O-Ring 12-2- True Mechanical Override utton 13 EV-1017- P Valve Handle ap ssembly Part number varies with valve model variation; consult factory. 3 Height varies with valve model variation; consult factory. The information contained in this document is subject to change without notice. HEQURTERS 10500 SEYMOUR VENUE FRNKLIN PRK, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com 2014 SLON VLVE OMPNY ode No. 0816434 Rev. 8 (08/14)