L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Similar documents
L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

BISON 20 OM BISON 25 OTI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

BULL 424 ESA BULL 624 ESA

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

Installation Manual. Swing Gate System. Leading the way...

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

FORCE SPD 800/1500/2000

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

FITTING AND CONNECTION INSTRUCTIONS

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

INSTRUCTIONS FOR INSTALLATION

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Ditec LUXO Swing gates automation (Original instruction)

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Automation Swing Gate Opener

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec PWR50H/HV/HR Automation for swing gates

Typical Installation Schematic

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Ditec CUBIC Swing gates automation

TECHNICAL DATA HYDRAULIC UNIT

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Ditec PWR25H/35H Automation for hinged gates

BIG Series. D_MNL0BIG Rev.18. IT - Istruzioni originali

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

E R A I GATE AUTOMATION DIVISION

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Automatic concealed bollards 275 H600 and 275 H800 with pit

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

INSPECTIONS AND MAINTENANCE

TITANO 400V SLIDING GATE OPENER

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

EC DECLARATION OF CONFORMITY

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Ditec BOX Balanced up and over doors

IMPORTANT NOTICE FOR THE INSTALLER

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

IGEA LB INSTALLATION AND USER'S MANUAL. MONTAGE- und BEDIENUNGSANLEITUNG INSTRUÇÕES DE USO E DE INSTALAÇÃO

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

CE DECLARATION OF MACHINE CONFORMITY

SWING GATE OPENERS 24V DC GEAR MOTOR

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

GB Instructions Manual

Electromechanical gear motor for sliding gates ACHILLES

Cross14, Cross14E, Cross14VE, Cross15V

Ditec DOD Industrial sectional door automations

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

Mod: KLD6-12/35XLAS-N

INSTALLATION MANUAL (cod )

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

Automatic concealed bollards 275 H600 and 275 H800 Control station

MOOVY AUTOMATIONS FOR SLIDING GATES (230/110/24V)

SLIDING GATE OPENER USER MANUAL

AUTOMATIC BOLLARD ASSEMBLY AND OPERATING MANUAL

Ditec VALOR Sliding doors automation (Original instructions)

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

GENERAL SAFETY... 3 PARTS LIST...

Oil-hydraulic operator for swinging gates

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

E R A I Gate Openers Department

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

TURBO 40 TURBO 80 TURBO 120 TURBO 160

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

D ver ACTUATOR FOR RACK SLIDING GATES ICARO UL INSTALLATION AND USER'S MANUAL.

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

INSTALLATION MANUAL GB

ECONOMISER SERIES E2T USER MANUAL

AEL5 Series Electric Linear Actuators

Operating Instructions

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

SWING GATE OPENERS 24V DC GEAR MOTOR

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

L /2010 rev 5 MATRIX MATRIX-RE CP.BULL CP.BULL-RI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

IP2160EN. Ditec NeoS / NeoS+ Sliding Gates. Technical Manual. (Original instructions)

Transcription:

L8542965 03/2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

1 470 327 F A 500 825 B 243.5 2 C 445 210 15 ±5 205 92 50 2

3 4 I D2 D2 D1 5 T 6 D A R I D G R 3

7 G MIN = 210mm MAX = 220mm MIN = 10mm MAX = 20mm 8 P S M 9 2 mm 4

10 1 3 cm G F A S ø 5,5 mm 11 1 2 3 4 5

2 x 1,5 12 FILTER GND CARTER-GND 400 Vac - 3PH 13 8 7 5 RG 58 4 3 4 x 0,35 6 1 2 4 3 x 1,5 min 230V 2 x 0,35 3 H 3 x 0,35 5 6

EC Declaration of Conformity Directive 2004/108/EC(EMC); 2006/95/EC (LVD) Manufacturer: Automatismi Benincà SpA. Address: Via Capitello, 45-36066 Sandrigo (VI) Italy It is hereby stated that the product automatic system 230 Vac for sliding gates BISON 45 OTI is compliant with provisions set forth in the following EC Directives: - DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004, on the harmonisation of the laws of Member States relating to electromagnetic compatibility and which cancels Directive 89/336/EEC, according to the following harmonised regulations: EN 61000-6-2:2005, EN 61000-6-3:2007. - DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006, on the harmonisation of the laws of Member States relating to electrical equipment designed for use with certain voltage limits, according to the following harmonised regulations: EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008; EN 60335-2-103:2003. - DIRECTIVE 2006/42/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 May 2006, on machinery, which amends Directive 95/16/EC, and complies with the requisites for the partly completed machinery (almost machinery) set forth in the EN13241-1:2003 regulation. Moreover, Automatismi Benincà SpA declares that the pertaining technical documentation has been drawn up in compliance with Attachment VII B of the 2006/42/ EC Directive and that the following requirements have been complied with: 1.1.1-1.1.2-1.1.3-1.1.5-1.2.1-1.2.3-1.2.6-1.3.1-1.3.2-1.3.3-1.3.4-1.3.7-1.3.9-1.5.1-1.5.2-1.5.4-1.5.5-1.5.6-1.5.7-1.5.8-1.5.10-1.5.11-1.5.13-1.6.1-1.6.2-1.6.4-1.7.2-1.7.4-1.7.4.1-1.7.4.2-1.7.4.3. The manufacturer undertakes that information on the partly completed machinery will be sent to domestic authorities. Transmission ways are also included in the undertaking, and the Manufacturer s intellectual property rights of the almost machinery are respected. It is highlighted that commissioning of the partly completed machinery shall not be provided until the final machinery, in which it should be incorporated, is declared compliant, if applicable, with provisions set forth in the Directive 2006/42/EC on Machinery. Moreover, the product, as applicable, is compliant with the following regulations: EN 12445:2002, EN 12453:2002, EN 12978:2003. Benincà Luigi, Legal Officer. Sandrigo, 02/11/2011.. WARNING The product shall not be used for purposes or in ways other than those for which the product is intended for and as described in this manual. Incorrect uses can damage the product and cause injuries and damages. The company shall not be deemed responsible for the non-compliance with a good manufacture technique of gates as well as for any deformation, which might occur during use. Keep this manual for further use. Qualified personnel, in compliance with regulations in force, shall install the system. Packaging must be kept out of reach of children, as it can be hazardous. For disposal, packaging must be divided the various types of waste (e.g. carton board, polystyrene) in compliance with regulations in force. The installer must supply all information on the automatic, manual and emergency operation of the automatic system and supply the end user with instructions for use. An omnipolar switch/section switch with remote contact opening equal to, or higher than 3mm must be provided on the power supply mains.. Make sure that before wiring an adequate differential switch and an overcurrent protection is provided. Pursuant to safety regulations in force, some types of installation require that the gate connection be earthed. During installation, maintenance and repair, cut off power supply before accessing to live parts. Descriptions and figures in this manual are not binding. While leaving the essential characteristics of the product unchanged, the manufacturer reserves the right to modify the same under the technical, design or commercial point of view without necessarily update this manual. 10

IntroduCTION Congratulations on your choice of a BISON gear motor. All items included in Benincà s wide product range stem from twenty year of our experience in the sector of automatic systems, always striving to find new materials and advanced technologies. For this reason, nowadays we are able to offer you extremely reliable products that, thanks to their power, efficiency and long-lasting features, entirely meet the end user s requirements. All our products are covered by a guarantee. Furthermore, an R.C. insurance policy signed with a primary insurance company, covers any injuries or damages caused by manufacturing faults. GENERAL INFORMATION Automatic system with 400VAC, three-phase power supply for sliding gates with 4500kg max weight, for industrial use, equipped with anti-crash device (encoder) and three-phase inverter. Mains power supply Motor power supply Consumption Thrust Operating jogging Protection level Operating temperature Gate max. weight SPECIFICATIONS BISON 45 OTI 400Vac three-phase 50/60Hz 400Vac three-phase 2.85 A 4600 N Heavy duty IP44-20 C / +50 C 4500 kg Rack module M6 Z 18 Opening speed Noise level 10,2 m/min <70 db Lubrication MOBIL SHC 629 Weight 75 kg PRELIMINARY CHECKS For a good operation of the automatic system for sliding gates, the gate/door to be automated shall feature the following characteristics: - the guide track and related carriers should be adequately sized and subject to maintenance (in order to avert excessive friction during the gate sliding). - during operation, no excessive oscillations should be reported to the gate/door. - the opening and closing stroke should be limited to a mechanical stop (according to the current safety regulation). These preliminary checks are MANDATORY. It is expressly FORBIDDEN to use the BISON automatic system on doors and gates not in good conditions or that have not undergone a correct maintenance. INSTALLATION OVERALL DIMENSIONS Figure 1 shows the overall dimensions of the gear motor, expressed in mm. Given the remarkable weight of the actuator, the device should be handled by at least 2 persons. Loosen the 4 B screws (Fig. 1) and entirely remove the front side of the system. Now all elements of the systems can be accessed. If only the control unit is to be reached, it is sufficient to remove the 4 A screws by lifting the upper cover. The niches for the photocell mounting (F) are provided on the motor removable side. CAUTION! The geared motor is equipped with a safety micro-switch which cuts off the mains power supply to the motor when the lower removable front side is removed or a power failure occurs. FOUNDATION PLATE - DIMENSIONS Fig.2 shows the installation dimensions of the foundation plate, expressed in millimetres. A hole has been drilled on the plate for the passage of cable. When the corrugated pipe is introduced, keep in mind that the hole to be used should be positioned as shown in Figure 2 (ref. C). The plate should be positioned at 15mm from the floor (with possible adjustment +/- 5mm), 15 mm above floor-level usually avert any water stagnation. At this height, the lower edge of the rack tooth should be at 215 mm. If the rack is already installed, a fitting base, raised with respect to the floor, should be required. However, it is not advisable to lower the fitting surface. If a different rack is used, find the correct distance by temporarily fitting it to the door/gate leaf, then place the gear motor and check that the pinion and the rack are geared together. INSTALLATION OF THE FOUNDATION PLATE Provide for an adequate hole for the foundation. Prepare the plate by fitting the foundation bolts, as shown in Fig. 3: Tighten the 4 D1 nuts to the foundation bolt T, then insert the plate and fix it with 4 D2 nuts. Pour cement on the plate (Fig. 4), taking care that the plate level should lie perfectly flat. Check that the threaded inserts (I) for the fitting screws are clean and cement free. Wait that the cement hardens. Note: It is also possible to use highly resistant special dowels to fix the foundation plate onto the floor. In this case, make sure that there is no water stagnation. In any case, the foundation plate should be adequate to the stress exercised on the automatic system. HOW TO FIT THE GEAR MOTOR Place to gear motor on the foundation plate, as shown in Figure 6, by inserting the slots F on the threaded inserts I. Fix the gear motor to the base, by using the washers R, the threaded washers Z and nuts D. The threaded holes allow for the horizontal movement of the gear motor, which is required to gear/ungear the pinion to the rack. HOW TO ADJUST THE HEIGHT OF THE GEAR MOTOR By acting on G grains, which lay against the foundation plate (Fig. 7), the height of the geared motor can be adjusted by keeping to dimensions shown in figure 2. HOW TO FIT THE RACK Temporarily fit the rack by using clamps, for example. Check that the system is perfectly flat, then fit the rack to the gate with various welding points of by using adequate screws. Keep to the tooth pitch P, even from the rack spaces. To this purpose, it might be useful to match another piece of rack (Fig. 8 - Detail C). Lastly fix the rack with screws V, making sure that, once the actuator is installed, around 2 mm backlash is left between 11

the rack and the drive wheel (see Fig. 9). HOW TO POSITION THE LIMIT SWITCH BRACKETS Manually open the gate, leaving 1 3 cm space, according to the weight of the gate, between the gate/door and the mechanical stopper A (Fig. 10). Then fix the bracket of the limit switch S in order that the micro-switch F of the limit switch is kept pressed. After drilling two holes of ø 5.5mm, use the two screws G supplied. Repeat this operation with closed gate/door. NOTE: The limit switch bracket should be positioned in order to allow that the gate/door stops its movement without hitting the mechanical stopper. MANUAL OPERATION In the event of power failure or faults, the gate can be manually operated as follows (Fig.10): - Open the protective cap from the lock, introduce the customized key supplied and turn it by 90 anti-clockwise. - Remove the lock group, introduce the hexagonal key supplied, and loosen the screws anticlockwise until the gate leaves are released. - The gear motor is released and the gate can be manually opened or closed. - To reset the normal operation, introduce the hexagonal key one again and turn firmly clockwise until it is locked. With an automatic operation check that no slipping occurs when the gate leaf is moving. - Apply the lock group again, making sure that the antirotation pin be introduced in the hole on the gear group. - Turn the key clockwise, then remove it and close the protection cap again. CONNECTION TO GROUND (EARTH) As regards the COMPULSORY earthing, a special Faston 4-pin connector fitted onto the central support (Fig. 12 CARTER-GND) is supplied. Ground connections of the upper removable side and the lower side can be connected to this Faston. To allow an easy removal of the sides, they are not supplied pre-cabled to the connector. The installer shall provide for their connection, by using the already equipped with Faston terminal. As shown in Figure 12, mains power supply should be connected to the mains filter (Fig. 12-FILTER), while for grounding the special terminal should be in use (Fig. 12-GND). WIRE DIAGRAM Figure 13 shows the cables to the preset for the installation of the gear motor and the main accessories. As regards the wire connection of the automatic system and the adjustment of the operating modes, see the instruction manual of the control unit. Before introducing the cables, check the type of cabling required for the accessories actually used. Key of components: 1 Gear motor with BISON built-in control unit. 2 Rack 3 Limit switch brackets 4 Photocells 5 Mechanical stoppers 6 Key selector or digital keypad 7 Flashing light 8 Antenna Note: The removable side of the BISON gear motor comes already preset for the mounting of the FTC.S photocells. WARNING The RC product insurance policy, which covers any injuries or damages to objects caused by manufacturing defects, requires the use of Benincà s original accessories. 12

1 2 13 14 12 10 9 15 11 5 6 10 16 3 4 13 7 8 BISON 45 OTI Ref. Code Note Ref. Code Note 1 9686530 11 9686538 2 9686549 12 9686551 3 9686531 13 9686777 4 9686532 14 9760021 MAG.E 5 9686533 15 9686536 6 9686541 16 9686698 7 9686540 8 9686548 9 9686776 10 9686537 31

AUTOMATISMI BENINCÀ SpA - Via Capitello, 45-36066 Sandrigo (VI) - Tel. 0444 751030 r.a. - Fax 0444 759728