Rotating Vane Anemometer

Similar documents
Rotating Vane Anemometer

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

Indoor Air Quality Meter

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

VELOCICALC Air Velocity Meter

DP-CALC TM Micromanometer

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

IAQ-CALC TM Indoor Air Quality Meter

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Model 8026 Particle Generator

Thermo-Anenometer Model Owner s Manual

IAQ-CALC TM Indoor Air Quality Meter

PRIMARY CALIBRATORS MODEL 4046/4146

Model 8026 Particle Generator

ANALOG BALANCING TOOL MODELS ABT701, ABT703, ABT711, ABT713

Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters

EXHAUST FAN FLOW METER

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

Respirator Fit Testers

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

Table of Contents Up and Running... 1 Measurements... 2 Keypad Operation... 4 Displayed Items... 4 Placement for Monitoring/Testing...

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

AXD 530 MicroManometer

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

INSTALL GUIDE Dodge/RAM 5.7L HEMI

OPERATING INSTRUCTIONS AND PARTS LIST

Model FHS5 Slimline Display Interface for FHC50/FHM10 P/N Installation Instructions

INSTALL GUIDE Silverado/Sierra L/6.2L

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Fifth Wheel Power Hitch Operations Manual

ACCUBALANCE Air Capture Hood Model 8371

INSTALL GUIDE Jeep Wrangler JK 3.6L V6

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

INSTALL GUIDE Ford F L

INSTRUCTIONS PARTS LIST

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

SIDESLIDE SERIES C-CLAMP 940K-010FI BOLT 940K-010RSC PICATINNY 940K-010PIC PRODUCT MANUAL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

SERIES 7400 THREE PIECE BALL VALVES

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

SERIES 9000 Double Offset HP Butterfly Valves

Straight-Bore Clutch LSCC-32, 44, 54

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

SERIES LVB Universal Globe Valve Linkage

Charging with AC (wall) Charger

HR-20P Pneumatically Controlled Pressure Regulator

JD-2 TOLL FREE UG August /2011

This manual covers the following model:

AIR CHAMP PRODUCTS. User Manual. BW Clutch or Brake Sheave, Pilot and Coupling Mount FORM NO. L U-1209 FORM NO.

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Harley Davidson FL Touring Current Xtreme

AXD 510 MicroManometer

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

ASSEMBLY OF TROLLEY TO HOIST

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Web Volume Control Model WV220

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

FR1118- P10. User s Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

EASY CONNECT CRANE KIT Festoon Conductor Systems

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Firstmate Installation Manual and User's Guide May, 2003

Electronic Pulse Meters

Car Vacuum Cleaner #CarVac

HighLuxV2-Zenigata Series

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

OWNERS MANUAL JANUARY 2007 ISO

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

Morgan Aero Products. AP7108 PNEUMATIC POWERED FISHPOLE HOIST Operation, Maintenance & Part s Rev. O - 01/01/13

EM20 Digital Anemometer User Manual

HIGH PERFORMANCE FUEL DELIVERY KIT DUAL STOCK PUMP VERSION L & L

CRD610 Automatic Fitting Inserter

Stainless Steel Air Motor Conversion Kits

ADI-125/750 ADI-125/1500 ADI-125/2500

EAGL 1-Touch Laser Level

Guardian FBA Flywheel Coupling

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

User Manual SH Slag Removal Tool for use on laser cutting machines with minimum 1.25 between slats

Hand-Held Mechanical Tachometer Model HTM

SERIES 7100 STANDARD PORT BALL VALVES

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

WEB CONTROL PRODUCTS

Analog Durometer Model AD-100

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Transcription:

Ventilation Testing Rotating Vane Anemometer Alnor Model RVA801 AIRFLOW Model LCA301 Operation and Service Manual

Copyright TSI Incorporated / 2007-2012 / All rights reserved. Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA Fax No. (651) 490-3824 LIMITATION OF WARRANTY AND LIABILITY (effective June 2011) (For country-specific terms and conditions outside of the USA, please visit www.tsi.com.) Seller warrants the goods sold hereunder, under normal use and service as described in the operator's manual, shall be free from defects in workmanship and material for 24 months, or if less, the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions and exceptions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment; b. Pumps are warranted for hours of operation as set forth in product or operator s manuals; c. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment; d. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies; e. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER S OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE iii

GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS OR ANY SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call Customer Service department at +44 (0) 149 4 459200 (UK), (800) 874-2811 (USA), or (1) 651-490-2811 (International). iv

SECTION 1 General Description The RVA801/LCA301 is intended for measurement of air velocity and volume flow at return grilles, fume hoods, kitchen exhausts, etc. It features a 180-degree rotating head which functions satisfactorily in the 0 o and 180 o positions. This allows the LCD display to be viewed from the front of the instrument while the head is oriented with the flow direction. In addition, the instrument measures the temperature of the air flow. SECTION 2 Safety Observe common sense safety precautions when using the RVA801/LCA301. Exercise care to ensure that the instrument does not interfere with any moving equipment or electrical wiring. This instrument is not designed for gas mixtures other than air. Use with explosive and/or other dangerous gas mixtures is not recommended and is at the user s own risk. -5-

SECTION 3 About the RVA801/LCA301 Installing the Battery The RVA801/LCA301 requires a 9-volt battery. The battery is not installed when the instrument is shipped. Remove the battery cover by pressing on the two lines and sliding downwards. Connect the battery to the flying lead, insert the battery into the instrument and replace the battery cover. LCD display The instrument will display the velocity, volume or temperature reading as selected. Auto Shut Off The RVA801/LCA301 has an auto shut off feature to help preserve battery life. If no keys are pressed for 3 minutes (5 minutes in temperature mode), the instrument will automatically turn itself off. This function cannot be disabled by the user. -6-

SECTION 4 Detailed Operation Press the ON\OFF key to turn the RVA801/LCA301 on and off. When the instrument is turned on, it will power up in the mode last used. On/ Off key Mode key English/Metric Unit Selection RVA801/LCA301 instruments can display Metric or Imperial units. To select metric or imperial units, press the Mode key while turning on the -7-

unit. Then press the trigger to select the unit type and press the Mode key again to save your setting. Measuring Air Velocity Select velocity using the MODE key if required. In order to take a velocity reading, hold the rotating vane in the airstream noting the flow direction arrow on the instrument head. Keep the vane in the airstream for about five seconds before pressing the trigger key to take a reading. This enables the vane anemometer to reach steady speed and the average reading will be more accurate. To take a single reading, press the trigger key momentarily. The instrument will display the measured value. Press and hold the trigger key to take a sweep, or time-averaged, reading. The sweep reading will update approximately every second. Release the trigger key to stop the sweep measurement and display the average value. Measuring Air Volume The operation for air volume measuring is the same as air velocity. To calculate air volume, the air velocity and area (duct, grille size or Air Cone data) are required. The RVA801/LCA301 rotating vane anemometer allows the user to -8-

enter the area into the instrument and get direct volume flow readings. To measure air volume, determine the crosssectional area of the duct or grille for which the volume flow rate is required. If working in metric units, calculations must be in m 2. If working in Imperial units, calculations must be in ft 2. Switch the instrument to Area + mode and observe the area figure displayed from the memory. If the new area required is larger than the one displayed press the trigger to increase the displayed area to the calculated figure. If the area is less than the figure displayed push the Mode Button to change to Area - mode and press the trigger to reduce the displayed area to the calculated figure. When the correct area has been displayed use the Mode key to select the required Vol mode. Note: If the area is entered incorrectly, the volume flow rate reading will also be incorrect. The last area value will be retained in the memory even when the instrument is switched off. Low Battery Indication When the "BAT" icon appears, the RVA801/LCA301 has about 60 minutes of battery life remaining. If the battery is not replaced, measurement accuracy will decrease. -9-

Serial Number Display The instrument s serial number can be verified by holding both the trigger and mode key when switching the unit on. SECTION 5 Care, Maintenance and Service Please return the Product Registration Card immediately. This allows us to send service reminders, special offers, and important information about your product. Remove batteries from instrument if not used for an extended period of time. Do not bend or touch blades; accuracy will be affected. Do not immerse in liquids. Do not drop the instrument. Use carrying case for storage, transport, and protection from dust. Use a clean damp cloth to wipe the instrument case. Do not wipe the blades. Service Return Process Return the RVA801/LCA301 for service in case the instrument was dropped, blades were -10-

deformed, or liquid spilled on the instrument, particularly the blades. Before sending your instrument for calibration or repair, obtain a Return Material Authorization (RMA) number by visiting our website at http://rma.tsi.com or contacting customer service. When obtaining an RMA number, you will also learn the cost of service or calibration and receive shipping instructions. Appendix A Volume Flow Rate Measurements Using Air Cones If Air Cones are used to measure the volume flow rate, the area entered in the instrument needs to be related to the 100 mm vane diameter. The correct value to be entered can be found in the Air Cone manual that comes with the cones (see side pocket of the carrying case). -11-

The following sticker can be found on the latest Air Cone offerings: -12-

-13-

(This page intentionally left blank) -14-

MODEL RVA801/LCA301 SPECIFICATIONS (subject to change without notice) Measurement Range Velocity 50 to 6000 fpm 0.25 to 30 m/s Temperature 32 to 140 F 0 to 60 C Volumetric Flow Rate 1-9999000 cfm 1-999999 l/s 1-999999 m 3 /h 0.01 3000 m 3 /s Area Input 0.043-900 ft 2 0.00399-90 m 2 Actual range is a function of velocity and area input. Display Resolution Velocity 1 fpm 0.01 m/s Temperature 1 F 0.1 C Accuracy Velocity ±1% reading ±4 fpm ±1% reading ±0.02 m/s Temperature ±2 F ±1 C Storage 14 to 140 F -10 to 60 C Temperature Operating Temperature Power Source Battery Life Dimensions (LWD) 32 to 140 F 0 to 60 C 9-volt battery Approximately 40 hours continuous use 11 in. 4.5 in. 2.6 in. Weight 10 oz. 275 g (excluding battery) 280 mm 112 mm 65 mm

TSI Incorporated 500 Cardigan Road Shoreview, MN 55126 USA Toll Free: (800) 874-2811 Tel: (651) 490-2811 Fax: (651) 490-3824 E-mail: customerservice@alnor.com Web: www.alnor.com TSI Instruments Ltd. Stirling Road Cressex Business Park High Wycombe Bucks HP12 3ST United Kingdom Tel: +44 (0) 149 4 459200 Fax: +44 (0) 149 4 459700 E-mail: info@airflowinstruments.co.uk Web: www.airflowinstruments.co.uk France Tel: +33 491 95 21 90 E-mail: tsifrance@tsi.com Website: www.tsiinc.fr Germany Tel: +49 241 523030 E-mail: tsigmbh@tsi.com Website: www.tsiinc.de Part No. AFL9021485 Rev. B Copyright 2012 by TSI Incorporated Quality Assured to ISO 9001:2008