Digital Flow Switch (Sensor Part) Operation Manual

Similar documents
10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

2-Color Display High-Precision Digital Pressure Switch

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display High-Precision Digital Pressure Switch

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Digital Flow Switch for Deionized Water and Chemicals

Series 10-ZSE40A(F)/10-ISE40A

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Low Differential Pressure Sensor ±1% F.S.

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Differential Pressure Transmitter

3-colour / 2-screen display

Pressure Transmitter

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-Color Display Digital Flow Switch

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Model Pressure range ON/OFF output Linear output

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Digital Flow Switch (Integrated display type)

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

2-Color Display Digital Pressure Switch

Digital Flow Switch (Remote type sensor unit)

2-Color Display Digital Pressure Switch

Digital display Pressure range ON/OFF output Linear output Model

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Remote Type Pressure Sensors Pressure Sensor Controllers

Digital Flow Switch (Integrated display type)

Model Pressure range ON/OFF output Linear output


WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Vacuum Equipment. Application. Series

3 -color/2-screen display

The Multivariable Air Flow Meter

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

2-Color Display Digital Pressure Switch

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Pressure & Flow Switches Sensors

The Multivariable Air Flow Meter

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Series ITV1000/2000/3000

PFA Eddysonic flowmeter

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series PSE560 Pressure Sensor For General Fluids... 90

DPS280 / DVS280 Series

Compact Proportional Solenoid Valve

HN B G1/US B G2/US B G3

Pressure Sensor for General Fluids PSE570/573/574

Digital display Pressure range ON/OFF output Linear output Model

Electro-Pneumatic Regulator Electronic Vacuum Regulator

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

3 -color/2-screen display

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

For material handling and clamping of small workpieces

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Compact Vacuum Ejector

Series ISA. Air Catch Sensor. For Detection of Work Presence

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Analog Input Terminal

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Digital Flow Switch (Remote type monitor unit)

2-colour Display High Precision Digital Pressure Switch

25% reduction in volume * PB1013A/Air-operated type without foot

LCD Readout Digital Pressure Switch

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Related vacuum products

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Flow sensor for compressed air

Differential Pressure Sensor

Non-Contact Sensor for Workpiece Placement Verification

Transcription:

Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series PF2A 5 PF2W 5 URL http://www.smcworld.com

Thank you for purchasing the SMC PF2 5 Series Digital Flow Switch. Please read this manual carefully before operating digital flow switch and understand digital flow switch, its capabilities and limitations. Please keep this manual handy for future reference. CONTENTS OPERATOR This operation manual has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment. Please read this operation manual carefully and understand it before assembling, operating or providing maintenance service to the flow switch. About display part The type of the display part combined with a sensor part is indicated to be PF2 3 with this manual. Refer to the following correspondence table for the display part type combined with each sensor part. Sensor Part PF2A 50/5 PF2A 5/52/55 PF2W /520/50 PF2W T/520T/50T PF2W 5 Display Part PF2A 300 or PF2A 30 PF2A 30 or PF2A 3 PF2W 300 or PF2W 30 PF2W 300 or PF2W 30 PF2W 330 or PF2W 33 SAFETY 2 Name and Functions of Individual Parts 5 Model Indication Method 6 Installation 7 Example of Internal Circuit and Wiring 0 Outline with Dimensions 3 Specification 6 To facilitate recycling, this manual is printed using biodegradable soy ink, which can easily be de-inked. This manual is printed in the "non-water system", which does not output toxic liquid waste.

SAFETY The Digital Flow Switch and this manual contain essential information for the protection of users and others from possible injury and property damage and to ensure correct handling. Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions. Please read the operation manuals of related apparatus and understand it before operating the flow switch. IMPORTANT MESSAGES Read this manual and follow its instructions. Signal words such as WARNING, CAUTION and NOTE, will be followed by important safety information that must be carefully reviewed. Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions. Indicates a potentially hazardous situation which if not avoided, may result in minor injury or moderate injury. Do not disassemble, remodel (including change of printed circuit board) or repair. An injury or failure can result. Do not operate beyond specification range. Fire, malfunction or switch damage can result. Please use it after confirming the specification. Do not operate in atmosphere of an inflammable, an explosive and corrosive gas. Fire or an explosion can result. This flow switch is not an explosion proof type. Prepare the double interlock by another system (Mechanical interlock etc.) and check operating normally, when using this flow switch for an interlock circuit. An accident by a malfunction may potentially result. Do not use with an inflammable, an explosive and combustible fluid. Otherwise, a fire or an explosion or damage may potentially result. (The detector of the flow switch for air is heated by C) 2 Gives you helpful information. Check fluid leak after installing the flow switch. Neglecting fluid leak may cause a damage to the machines and equipment. A burn may potentially be inflicted for high temperature model for water. Do not touch the pipe joining parts. (High temperature model for water) Otherwise, a burn may potentially be inflicted. Touch it after confirming that the part is sufficiently cool. 3

SAFETY (continue) NOTE Follow the instructions given below when handling your flow switch. Otherwise, the switch may be damaged or may fail, thereby resulting in malfunction. Do not drop it, bring it into collision with other objects or apply excessive shock (90m/s 2 or more). Do not pull the lead wire with force nor lift the main unit by holding the lead wire. (Pulling strength less than 9N) Wiring correctly. Do not wiring while power is on. Although the flow switch complies with the CE Marking, since it does not have the thunder serge protection, please carry out protection to thunder serge by the equipment side. Although the flow switch complies with the CE Marking, since the equipment and apparatus which are made to generate the serge (Electro-magnetic lifter, High frequency induction furnace, Motor etc.) around the flow switch should perform measure against serge come out. Do not use with power cable or high-voltage cable in the same wire route. Do not use in a place in which oil or a chemical splashes. Turn on the power supply of a flow switch for Air, when flow is zero. Some initial drift occurs during ten minutes after turning the power on. Start measurement by the flow switch three seconds after turning on the power. (Also in momentary interception of the power supply by reset etc.) Please take a measure by the program of equipment etc. Install a filter on the primary side (inlet side) if foreign matter is feared to mix in a fluid. Use this flow switch under the specified operating pressure range. Design the pipe and set the switch for water so that the pressure beyond the specified pressure range by the water hammer may not be impressed. Do not attach the flow switch for air the bottom of a body upward. Names and Functions of Individual Parts Body Flow switch sensor body The arrow on the side of the body indicates the direction of flow. Piping port This port connects with pipeline. Use a pipe fitting to connect with external pipeline. Accessories (When no symbol is specified for optional wiring in the type specification.) Lead wire with connector on one end (3m in length). connector Piping port(out) Lead wire with connector Piping port(in) Body Bracket PF2W 5 5

Model Indication Method Sensor Part PF2 5 Fluid A:Air W: Water Specification No Symbol: Pulse output (Direct Sensor output) : Pulse output + ( to 5V) 2: Pulse output + ( to 20mA) Lead Wire Specification No Symbol: Lead wire with connector N : None Lead wire with connector Pipe Port Size (Refer to table below) 0: Port Size /8 02: Port Size / 03: Port Size 3/8 0: Port Size /2 06: Port Size 3/ 0: Port Size Port Screw Type No Symbol: Rc N: NPT F: G Installation Before you mount a flow switch, read "SAFETY " and "Installation" described in this chapter carefully to obtain safe and correct measurement. Mounting Use this flow switch under the specified operating pressure range. Use this flow switch under the specified operating temperature range. Withstand pressure are.0mpa for air and.5mpa for water. Do not install a flow switch at a foothold position. Bubbles may be generated depending on the piping design. Refer to an example of recommended piping system. (For water) Flow Flow Zero or more Flow Temperature Range (Indicated for high temperature type) T: 0 to 90 C Flow Zero or more Bubbles (for water) Flow 6 Type PF2A 5 PF2W 5 Flow Rate 0: to 0r/min : 5 to r/min : 0 to 00r/min 2: 20 to 200r/min 5: to 0r/min 0: 0.5 to r/min 20: 2 to 6r/min 0: 5 to 0r/min : 0 to 00r/min Pipe Port Size 0, 02 0, 02 03 03 0 03 03, 0 0, 06 06, 0 PF2W 5 Install a flow switch so that the flow direction agrees with the arrow direction on the side of the body. Provide a straight pipe length of more than eight times the pipe diameter to the primary side (inlet side) of the flow switch. To start designing piping system, check the pressure loss at the operating flow rate using the flow rate characteristic (pressure loss) curve. 7

Installation (continue) Pipe Connection Use a pipe fitting to connect pipeline with the flow switch. Observe the specified tightening torque when connecting pipes. Refer to the following table for the appropriate torque values. Nominal size of screws Rc /8 Rc / Rc 3/8 Rc /2 Rc 3/ Rc Appropriate tightening torque N m 7 to 9 2 to 22 to 2 28 to 30 28 to 30 36 to 38 When connecting pipeline to the switch, apply a spanner to the metal part of the piping section for the switch. Press Loss (kpa) Flow rate characteristic (Pressure Loss) 3 2 0 a Flow rate (r/min) Type PF2A 50 PF2A 5 PF2A 5 PF2A 52 PF2A 55 b B A Press Loss (kpa) Graph A B C D E 0 30 20 0 0 a Flow rate (r/min) a (r/min) 5 0 20 b (r/min) 0 00 200 0 b E D C 8 spanner spanner PF2W 5 Make sure that sealing tapes will not enter inside the pipe when connecting pipes. Connect pipes securely so that fluid will not leak from loose connections. Press Loss (MPa) 0.07 0.06 C 0.05 0.0 B 0.03 D 0.02 A 0.0 0 a Flow rate (r/min) b Type Graph a (r/min) b (r/min) PF2W /T A 0.5 PF2W 520/520T B 2 6 PF2W 50/50T C 5 0 PF2W 5 D 0 00 9

Example of Internal Circuit and Wiring The pulse output is output for flow rate display. Be sure to combine the display part with the PF2 3 0/3 series manufactured by SMC. When the Lead wire with connector provided by SMC corporation is used the color of wire(brown, White, Black, Blue) shown on circuit diagram will be applied. Specification No Symbol Pulse Nch Open Drain Sensor Part NC 2 3 Display Part PF2 3 0/3 Brown 2 6 Black Blue (For PF2 3 0/3 Series) 8 3 7 5 Switch output (Note ) + 2 to 2V DC 2 Pulse Nch Open Drain (For PF2 3 0/3 Series) Analog : to 20mA Load Impedance:300Ω or less (@2VDC), 0Ω or less (@2VDC) Display Part Sensor Part PF2 3 0/3 Brown 2 6 Analog White 2 Load 8 Switch + output 3 7 (Note ) Black 3 5 Blue (Note ) See the operation manual of PF2 3 0/3 series for complete information. 20 5 2 to 2V DC 20 5 Pulse Nch Open Drain Analog : to 5V 0 Display Part Sensor Part PF2 3 0/3 Brown 2 6 Analog White 2 Load 8 Switch + output 3 7 (Note ) Black 3 5 Blue (For PF2 3 0/3 Series) Load Impedance: 00kΩ or more 2 to 2V DC Current (ma) 0 a Flow rate (r/min) b Type a b PF2A 50 0 PF2A 5 5 PF2A 5 0 00 PF2A 52 20 200 PF2A 55 0 Voltage(V) Current (ma) 0 a Flow rate (r/min) Type a b PF2W 0.5 PF2W 520 2 PF2W 50 5 b 6 0 PF2W 5 0 00 PF2W 2T 0.5 PF2W 520T 2 6 PF2W 50T 5 0 Voltage(V)

Example of Internal Circuit and Wiring (continue) How to connect connectors: Turn off power before connecting or disconnecting the connector. To insert the connector, push the connector socket of the lead wire to the key part of the switch connector after aligning them to each other and secure the connector with the lock nut. To disconnect the connector, unlock the connector lock nut and pull out the connector straight. Install the lead wire separately from the route for power cable or high-voltage cable. Otherwise, malfunction may potentially result due to noise. Connector pin number 3 2 Key Pin No. (No Symbol) DC (+) 2 NC 3 DC ( ) Pulse output Pin name With analog output (- or -2) DC (+) DC ( ) Pulse output Outline with Dimensions (in mm) PF2A 50 / 5 5 (3.5) -ø.5 98 82 8.2 0 3 2-ø3. PF2A 5 / 52 / 55 6 76.2 3 2-Piping port 2 23 23.6 6.6 2mm 52mm 62mm 72mm 5 30 -ø.5 0 2-Piping port 30 (3.5) 8mm 58mm 62mm 72mm 2 3

Outline with Dimensions (in mm) (continue) PF2W / 520 PF2W 5 L 8.2 23.6 8 80 32 (3.5) 5 -ø.5 0 3 2-ø3. 3 2-Piping port 6 Type PF2W PF2W 520 2mm 52mm L 00mm 06mm 62mm 72mm (3.5) 70 58 6 -ø5 36 5 2-Piping port 5 2 63mm 73mm 77mm 87mm PF2W 50 PF2W T / 520T / 50T 20 8.2 23.6 20 23.6 (3.5) -ø.5 3 55 0 2-Piping port 6 2mm 62mm (3.5) -ø.5 0 2-Piping port 3 3 52mm 72mm 52mm 72mm 62mm 82mm 5

Specification Model PF2A 50 PF2A 5 PF2A 5 PF2A 52 PF2A 55 Rated Flow Range to 0r/min 5 to r/min 0 to 00r/min 20 to 200r/min to 0r/min Operating Pressure Range kpa to 0.5MPa kpa to 0.75MPa Linearity (*) Repeatability (*) Temperature Characteristic Current Consumption (No load) ±5%F.S. or less ±%F.S. or less ±2%F.S. or less (5 to 35 C, 25 C standard) ±3%F.S. or less (0 to C, 25 C standard) 00mA or less Mass (Weight) (*2) 200g 20g 0mA or less Piping Specification /8, / 3/8 /2 Material of Wet Part Attachment: ADC Packing: NBR Mesh: SUS Internal Body: PBT Sensor-housing: PBT Sensor: Lead-glass/ PtIr/ FeNi/ OFC Attachment: ADC Packing: NBR Spacer: PBT Mesh: SUS Internal Body: PBT Sensor-housing: PBT Sensor: Lead-glass/ PtIr/ FeNi/ OFC Common Specification Fluid to be Measured Detecting Method Withstand Pressure Operating Fluid Temperature Ambient Temperature Range Specification (*3) Sensor Analog Power Supply Voltage Withstand Voltage Insulation Resistance Resistance to Noise Air, Nitrogen Calorimetry.0MPa 0 to C Operation: 0 to C, Storage: 25 to 85 C (No condensation or Freezing) impedance kω, (for Display Part PF2A 3 ) Voltage to 5V (Within rated flow rate range) Linearity: ±5%F.S. or less, Permissible load impedance: 00kΩ or more Current to 20mA (Within rated flow rate range) Linearity: ±5%F.S. or less, Permissible load impedance: 300Ω or less (@2VDC), 0Ω or less (@2VDC) 2 to 2VDC, ripple ±0% or less 000VAC minute. Between group of external terminals and case MΩ or more (@ 0VDC M). Between group of external terminals and case 000Vp-p pulse width µs, rise ns Vibration proof Impact proof Enclosure 0 to 0Hz and amplitude.5mm or acceleration 98m/s 2 whichever is smaller 90m/s 2, (3times each directions of X, Y and Z respectively) IP65 6 *: This is an overall accuracy combined with PF2A 3. *2: Lead wire not included. (The one with analog output (either voltage or current output) is 20g heavier.) *3: Select the output option by the Model indication Method. *: The flow unit is based on 0 C/ 0.3kPa. *5: The sensor part conforms entirely to the CE standard. 7

Specification (continue) Model PF2W PF2W 520 PF2W 50 PF2W 5 Fluid to be Measured Water Rated Flow Range 0.5 to r/min 2 to 6r/min 5 to 0r/min 0 to 00r/min Operating Fluid Temperature Linearity (*) Repeatability Temperature Characteristic ±5%F.S. or less ±2%F.S. or less 0 to C ±2%F.S. or less (5 to 35 C, 25 C standard) ±3%F.S. or less (0 to C, 25 C standard) ±3%F.S. or less ±%F.S. or less Mass (Weight) (*2) 0g 70g 6g,00g 0 to 0Hz and amplitude.5mm or Vibration proof.9m/s 2 acceleration 98m/s 2 whichever is smaller Piping Specification 3/8 3/8, /2 /2, 3/ 3/, Attachment: SUS, Packing: NBR, Material of Wet Part Internal Body: PPS, Sensor: PPS Model PF2W T PF2W 520T PF2W 50T Water, Fluid to be Measured % of water and an ethylene glycol % fluid Rated Flow Range 0.5 to r/min 2 to 6r/min 5 to 0r/min Operating Fluid Temperature Linearity (*) Repeatability Temperature Characteristic Mass (Weight) (*2) Vibration proof Piping Specification Material of Wet Part 0 to 90 C (No cavitation) ±5%F.S. or less ±2%F.S. or less ±5%F.S. or less (0 to 90 C, 25 C standard) 6g 0 to 0Hz and amplitude.5mm or acceleration 98m/s 2 whichever is smaller 3/8 3/8, /2 /2, 3/ Attachment: SUS, Packing: FKM, Internal Body: PPS, Sensor: PPS Common Specification Detecting Method Operating Pressure Range Withstand Pressure Ambient Temperature Range Specification (*3) Power Supply Voltage Current Consumption Withstand Voltage Insulation Resistance Resistance to Noise Vibration proof Impact proof Enclosure Pulse Analog Karman Vortex Method 0 to MPa.5MPa Operation: 0 to C, Storage: 25 to 85 C (No condensation or Freezing) Nch Open Drain for Display Part PF2W 3 0/3 (Reference : Maximum load current 0mA, maximum applied voltage 30V) Voltage to 5V (Within rated flow rate range) Linearity: ±5%F.S. or less, permissible load impedance: 00kΩ or more Current to 20mA (Within rated flow rate range) Linearity: ±5%F.S. or less, Permissible load impedance: 300Ω or less (@2VDC), 0Ω or less (@2VDC) 2 to 2V DC, ripple ±0% or less 20mA or less (No load) 000VAC minute. Between group of external terminals and case MΩ or more (@ 0VDC M). Between group of external terminals and case 000Vp-p pulse width µs, rise ns 0 to 0Hz and amplitude.5mm or acceleration 98m/s 2 whichever is smaller 90m/s 2, (3times each directions of X, Y and Z respectively) IP65 *: This is an overall accuracy combined with PF2W 3. *2: Lead wire not included. (The one with analog output (either voltage or current output) is 20g heavier.) *3: Select the output option by the Model indication Method. *: The sensor part conforms entirely to the CE standard. 8 9