Pulsar EXtreme 2200C / 3200C

Similar documents
Pulsar EXtreme CLA 1500C

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Pulsar Evolution 2200/3000/3000 XL

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1

5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R. User's guide

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual. Tower models 5P 750 5P P P 850G 5P 1550G

5P 1500 RT 5P 2200 RT 5P P 3000 RT 5P Installation and user manual ENGLISH. Copyright 2012 EATON All rights reserved.

3000VA 120/208/230VAC

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Eclipse Plus VA UPS and Surge Suppressor User s Manual

HPE T750 G5 UPS, T1000 G5 UPS, and T1500 G5 UPS User Guide

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Liebert GXT MT+ User Manual VA Installer/User Guide

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

HP R/T3000 G4 and HP R/T2200 G4 UPS User Guide

3 Uninterruptible Power Systems

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Foreword

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

Back-UPS CS Back-UPS CS 350

Installation and Operation Smart-UPS SUA500PDR

3 Uninterruptible Power Systems

HP 1U UPS User Guide. Abstract. Part Number: November 17, 2014 Edition: 1

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

User manual Digital Energy Uninterruptible Power Supply GT Series UPS 6-10 kva

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL DN / DN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Foreword. Manual instruction

Uninterruptible Power System

User Manual V1.0 MaxiFlex 3000

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Mission 1K Single Phase UPS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

MGE TM Galaxy TM 7000

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

User Manual. PF0.9 6K/10K Online UPS

MGE TM Galaxy TM 7000 GFC

BRAVER UPS. (Uninterruptible Power System) User s Manual

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

MGE Galaxy PW kva 480 V. Operation

User Manual Uninterruptible Power Supply

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

1. Important Safety Warning

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PR1000ELCD / PR1500ELCD User s Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

Installation and Operation Manual Back-UPS BX1100CI-CN

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

POWERWARE User s Guide VA.

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specification SENTINEL PRO

Uninterruptible Power Supply

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

USER MANUAL ONLINE UPS

Uninterruptible Power System

SUA1000I-IN / SUA1500I-IN 230 VAC

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

XPRT 6kVA & 10kVA Online UPS

MGE TM Galaxy TM 6000 : Specification guide. Single UPS, three-phase, 250 to 600 kva

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

MKN-DSP SERIES - THREE PHASE

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Installation and Operation Back-UPS BX550CI-CN

Technical Data Sheets

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Sola 3000 Guide Specifications

Liebert PowerSure PSI UPS

UPS2000-G-(1 kva-3 kva) Quick Guide. Issue: 05 Date: HUAWEI TECHNOLOGIES CO., LTD.

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Solar Hybrid Inverter SP Brilliant Series

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

User Manual Rittal PMC UPS 6kVA

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Transcription:

www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 00C / 300C Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 3400753EN/AA - Page

Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EXtreme C range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar EXtreme C a reference in environmental protection include: the eco-design approach used in product developmen, recycling of Pulsar EXtreme C at the end of its service life. To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar EXtreme C range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. Page - 3400753EN/AA

Foreword Using this document Information may be found primarily by consulting: the contents, the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. 3400753EN/AA - Page 3

Page 4-3400753EN/AA

Contents. Presentation. Standard positions... 7 Rack position... 7 Tower position... 7. Back... 8 Pulsar EXtreme 00C... 8 Pulsar EXtreme 300C... 8 Pulsar EXB 00 / 300... 8.3 Control panel... 9. Installation. Unpacking and checks... 0. Installation in rack position....3 Installation in tower position....4 Connection to the RS3 or USB communications port (optional)... 3.5 Installation of the communications-card option... 3.6 Connections... 4 3. operation 3. Start-up... 5 3. Bargraph indications... 5 3.3 Operation on battery power (following failure of AC input power)... 6 Transfer to battery power... 6 Threshold for the low-battery warning... 6 End of backup time... 6 3.4 Personalisation (optional)... 7 Function... 7 "ON / OFF conditions" tab... 7 "Battery" tab... 7 "Output" tab... 8 "Bypass" tab... 8 3.5 UPS Shutdown... 8 3.6 UPS remote power off... 9 3400753EN/AA - Page 5

Contents 4. Maintenance 4. Troubleshooting... 0 4. Replacement of the battery module... 5. Environment... 4 6. Appendices 6. Technical characteristics... 5 6. Glossary... 6 6.3 Index... 7 Page 6-3400753EN/AA

BYPASS 0% 50% 80% 00% % BYPASS test % 0% 50% 80% 00% %. Presentation. Standard positions Rack position 438 mm (9") 654 mm P U L S A R EXtreme 86.5 mm (U) www.mgeups.com Pulsar EXtreme 00C: 35.3 Kg Pulsar EXtreme 300C: 35.7 Kg Tower position test % P U L S A R EXtreme www.mgeups.com 3400753EN/AA - Page 7

. Presentation. Back Pulsar EXtreme 00C Slot for communications-card option. 3 8 9 0 RS3 communications port. 3 USB communications port. 4 Four outlets for direct connection of protected equipment. 5 4 7 5 Two programmable outlets (outlet and ). Pulsar EXtreme 300C 3 8 6 9 0 6 7 Output circuit breakers. Socket for connection to AC-power source. 8 Connector for an additional battery module. 9 Connector for automatic detection of an additional battery module. 5 4 7 0 Pushbutton to test phase/neutral inversion of AC-power source. Pulsar EXB 00 / 300 4 5 LED indicating phase/neutral inversion of AC-power source. Connector for remote power off. 3 Battery module connectors (to the UPS or to other battery modules). 3 3 4 5 Connectors for automatic detection of additional battery modules. Circuit breaker for battery ON/OFF and protection. Page 8-3400753EN/AA

. Presentation.3 Control panel BYPASS test % 0% 50% 80% 00% % 6 7 8 9 0 3 4 5 6 7 6 ON / OFF. 7 Operation on battery power. 8 9 Operation in ON-LINE mode (backup power available). Operation on bypass (no backup power available). Alarms % battery remaining % load 0 3 Status of programmable outlet : Status of programmable outlet : Lamp test or buzzer OFF. Forced transfer to bypass and back by pressing button 3 times in less than 5 seconds. Hold down to display percent load: Supplied with power. Status change in progress. Press simultaneously at least 3 seconds to reset the End of battery life alarm. 7 6 5 4 UPS overload Electronics fault Battery fault * 00% 80% 50% 0% 00% 80% 50% 0% (*) : flashing LED + buzzer: battery fault (battery must be replaced). flashing LED + long buzzer (once per hour): theoretical end of battery life (replacement recommended). 3400753EN/AA - Page 9

BYPASS 0% 50% 80% 00% %. Installation. Unpacking and parts check 8 30 9 3 3 33 test % 34 P U L S A R EXtreme 35 www.mgeups.com 36 8 Cord for connection to the AC-power source for Pulsar EXtreme 300C versions only (for the Pulsar EXtreme 00C version, use the power cord of the protected equipment). 9 30 3 3 33 34 35 36 Two cords for connection of the protected equipment. RS3 communications cable. USB communications cable. Telescopic rails for mounting in 9" bay with mounting hardware. Securing system for equipment power cords. CD-ROM with the Solution-Pac and UPS Driver software. Product documentation. Two supports for the upright position. Page 0-3400753EN/AA

BYPASS 0% 50% 80% 00% %. Installation. Installation in rack position Follow steps to 6 for rack mounting of the UPS on the rails. 4 6 3 test % 3 5 The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. Note for step 3: It is possible to adjust the positions of the front brackets. 3400753EN/AA - Page

BYPASS 0% 50% 80% 00% %. Installation.3 Installation in tower position Connect the two supports for the upright position. test % P U L S A R EXtreme www.mgeups.com P U L S A R EXtreme www.mgeups.com Page - 3400753EN/AA

. Installation.4 Connection to the RS3 or USB communications port (optional) 30 3 - Connect the RS3 30 or USB 3 communications cable to the serial port or the USB port on the computer. - Connect the other end of the communications cable 30 or 3 to the RS3 or USB 3 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. 3 The RS3 and USB communications ports cannot operate simultaneously..5 Installation of the communications-card option Slot for the communicationscard option. It is not necessary to shut down the UPS to install the communications card: - Remove the slot cover secured by two screws. - Insert the card in the slot. 3 - Secure the card with the two screws. 3400753EN/AA - Page 3

. Installation.6 Connections Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. 7 8 9 4 5 33 - Remove the power cord supplying the equipment to be protected. - Pulsar EXtreme 00C: connect the power cord () just removed from the equipment to the AC-power socket 7 and then to the AC-power wall outlet. - Pulsar EXtreme 300C: connect the supplied power cord 8 (50 V, 6 A) to the AC-power socket 7 and then to the ACpower wall outlet. 3 - Connect the protected equipment to the UPS using the two cords 9. It is advised to connect priority loads to the four outlets 4 and any non-priority loads to the two programmable outlets 5 (If the UPS is connected to a computer running MGE UPS SYSTEMS communications software, it is possible to program the interruption of power to the two programmable outlets 5 during operation on battery power, thus reserving backup power for the priority loads). 4 - Lock the connections using the securing system 33. As soon as the UPS is energised, the battery begins charging. Eight hours are required to charge to the full rated backup time. () Make sure the cord has the following characteristics: 50 V, 0 A, cross-sectional area mm, type HO5. Page 4-3400753EN/AA

BYPASS 0% 50% 80% 00% % 3. Operation 3. Start-up The protected equipment connected to the UPS can be energised, whether AC input power is available or not. test % Caution: the AC input power source must be present when energising for the first time. Press the ON / OFF button 6. The buzzer beeps and all the LEDs go ON. The buzzer beeps twice, then: If AC input power is available, LED 8 goes ON, indicating operation in ON-LINE mode. If AC input power is not available and the UPS is configured for automatic restart mode, the buzzer beeps three times and LED 7 goes ON, signalling operation on battery power. 6 7 8 5 6 7 All connected equipment is energised. If LEDs 7 or 8 do not go ON or if LEDs 5 to 7 flash, there is a fault (see section 4.). 3. Bargraph indications BYPASS test % 0% 50% 80% 00% 6 7 8 9 0 3 4 5 6 7 % LEDs 4 to 7 provide three different indications: - Remaining backup time in percent (during normal operation). - Percent load drawn by the protected equipment, when button 3 is pressed. 3 - Operating faults (flashing LED and beeps): 7 Overload. 6 UPS fault. 5 Battery fault or end-of-life warning. Status LEDs 0 and for programmable outlets and : LEDs OFF: the outlets are not supplied with power. LEDs flashing: status change in progress. LEDs ON: the outlets are supplied with power. Outlets and can be remotely programmed and controlled. They may be used for sequential start-up of the protected applications, shedding of non-priority applications during operation on battery power, and priority management at the end of battery backup time to reserve the longest possible backup time for the most sensitive applications. These outlets are programmed using Solution Pac software. 3400753EN/AA - Page 5

3. Operation 3.3 Operation on battery power (following failure of AC input power) Transfer to battery power BYPASS The AC-power source is outside tolerances, LED 7 is ON, the buzzer beeps three times. The equipment connected to the UPS is supplied by the battery. test 7 Threshold for the low-battery warning BYPASS The low-battery warning threshold can be set by the user, with the UPS Driver software (see section 3.4). LED 7 flashes. The buzzer beeps every three seconds. 7 test % There is very little remaining battery backup time. Close all applications because UPS automatic shutdown is imminent. End of backup time BYPASS The buzzer sounds continuously. Press button to turn the buzzer OFF. The equipment is no longer supplied with power. test % The UPS goes to sleep mode at the end of the battery backup time until complete shutdown due to tripping of the batteryprotection function against deep discharge. Return of AC input power: If, in spite of the return of AC input power, the UPS does not restart, check that the automatic-restart function (activated by return of AC input power) has not been disabled (see section 3.4). Page 6-3400753EN/AA

3. Operation 3.4 Personalisation (optional) Function Personalisation parameters can be set and modified using the UPS Driver software installed on a computer that is connected to the UPS (see section.4 Connection to the RS3 communications port). Check that the RS3 30 cable is properly connected. UPS Driver installation: - Insert the Solution-Pac CD-ROM containing the UPS Driver software in the computer drive. - Open the Windows file manager or explorer and select the CD drive. 3 - Run "\Emb\Config\UPSDRVxx.exe", where xx is the software version. It is also possible to download the UPS Driver software from the www.mgeups.com site. Once the UPS Driver software has been installed, the parameters listed below can be modified. "ON / OFF conditions" tab Personalisable function Automatic start Cold start (battery power) Forced shutdown Sleep mode UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Options Disabled Disabled Disabled Enabled Disabled "Battery" tab Personalisable function Automatic "Battery test" intervals "Low-battery warning" threshold Protection against deep discharges Default setting Every weeks 0% remaining battery backup time Enabled Options Once a day Once a month No test From 0% to 00% of the remaining battery backup time Disabled 3400753EN/AA - Page 7

3. Operation "Output" tab Personalisable function Rated UPS voltage Frequency mode Rated UPS frequency UPS tolerance for AC-power source frequency Overload alarm threshold UPS restart following short-circuit Default setting 30 V Autoselect F = 50 Hz F ± 5% 0% Disabled Options 00 V - 08 V - 0 V - 40 V - 50 V Converter 60 Hz F ± % to ± 0%, in % steps 0 to 0%, in 0% steps Enabled (click to add check) "Bypass" tab Personalisable function Transfer to bypass if overload Transfer to bypass following a fault, whatever the conditions on the AC-power source Default setting Enabled Disabled Options Disabled (click to remove check) Enabled (click to add check) 3.5 UPS shutdown BYPASS Press button 6 (return to the OFF position). The connected equipment is no longer supplied with power. test 6 Page 8-3400753EN/AA

3. Operation 3.6 UPS remote power off Pulsar EXtreme C is equipped with a remote power off function (RPO) that can cut power to all the devices connected to the UPS using a remote user-operated contact. The function is implemented by opening a contact connected to the two terminals of connector on the back of the UPS. 37 38 Installation and test of the remote power off function - Check that the UPS is shut off and disconnected to the AC-power source. - Remove the RPO connector by undoing the screws 37. 3 - Connect an insulated dry contact (NC, 60 V DC, 30 V AC max., 0 ma max., cable size 0.75 mm ) to the two terminals of the RPO connector 38. 4 - Put the RPO connector back in place on the back of the UPS. 5 - Connect the UPS to the AC-power source and restart it as indicated previously. 6 - Activate the RPO external contact to test the function. 7 - To return to normal operation, deactivate the RPO external contact and restart the UPS using button 6 (press OFF, then ON). 3400753EN/AA - Page 9

4. Maintenance 4. Troubleshooting If any of LEDs 5, 6 or 7 flash, there is a operating anomaly or an alarm. If a LED flashes, the bargraph data is no longer displayed. Indication LED 7 flashes and the buzzer beeps. LED 5 flashes and the buzzer beeps. LED 5 flashes and the buzzer emits a long beep once per hour. The yellow LED 4 flashes, the red indicator light behind the UPS comes on and the buzzer sounds continuously. Diagnostic UPS overload. Overload is too long or too high. If AC power is present and within tolerances, the UPS goes to bypass mode (supply directly by the AC-power source). LED 9 flashes. The buzzer beeps every seconds. If AC power is not present or not within tolerances, the connected applications are no longer supplied. The buzzer sounds continuously. A battery fault was detected during the automatic battery test. The battery has reached the theoretical end of its service life. The function for monitoring the phase and neutral position of your electrical network has detected a reversal. Correction Check the power drawn by the equipment and disconnect any nonpriority devices. Check that the battery connector is fully pushed in. Replace battery module (see the Maintenance section). Reset the alarm by pressing buttons and 3 simultaneously for 3 seconds. It is advised to replace the battery. See the section on maintenance. Directly earthed neutral type networks: to correct cabling, unplug and turn the network socket, of the DIN-SCHUKO type, by 80 degrees or contact an electrician to modify your electrical network. For all other network types, deactivate the detection function (this function is only operational for directly earthed neutral electrical networks): Press for at least 5 seconds the pushbutton 0 behind the UPS (UPS stopped and connected to the network for less than 30 minutes). Page 0-3400753EN/AA

4. Maintenance Indication The outlets are not supplied with power, even though button 6 is ON (version 300C only). LED 6 flashes and the buzzer sounds continuously. Signification One of the protection circuit breakers 6 for the outlets on the back of the UPS is open. UPS electronics have detected a UPS fault. Depending on the UPS personalisation parameters (see section 3.4), there are two possibilities: the equipment connected to the UPS continues to be supplied, but directly from the AC-power source (via the automatic bypass (LED 9 ON); the connected equipment is no longer supplied. Correction Check that there is not a shortcircuit on the outlets. Eliminate any overloads on the outlets by modifying the distribution of devices on the outlets. Restart the UPS. Call the after-sales support department. The equipment connected to the UPS is no longer protected. 3400753EN/AA - Page

BYPASS BYPASS 0% 50% 80% 00% % 0% 50% 80% 00% % 4. Maintenance 4. Replacement of the battery module Safety rules: Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions must be taken for all handling: remove all watches, rings, bracelets and any other metal objects; use tools with insulated handles. Removal of battery module A - Slide a finger in the slot to remove the MGE UPS SYSTEMS logo from the front of the UPS. B - Remove the two screws. P U L S A R EXtrem e test % A B www.mgeups.com C - Remove the left side of the front panel. D - Remove the connector. test % D P U L S A R EXtreme C Page - 3400753EN/AA

BYPASS BYPASS 0% 0% 50% 50% 80% 80% 00% 00% % % 4. Maintenance E - Remove the screws for the battery cover. F - Remove the cover. test % E F G - Remove the battery units and replace them. test % G G Reinstallation of the battery module Carry out the above operation in reverse order. To maintain an identical level of performance and safety, use a battery module identical to that previously mounted in the UPS. Press the two parts of the battery connector tightly together to ensure proper connection. 3400753EN/AA - Page 3

5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (contact your MGE UPS SYSTEMS branch office). Packing: UPS packing materials must be recycled in compliance with all applicable regulations. Warning: This product contains lead-acid batteries. Lead is a dangerous substance for the environment if it is not properly recycled by specialised companies. Web site: www.mgeups.com Page 4-3400753EN/AA

6. Appendices 6. Technical characteristics Rating AC input Voltage Frequency Power factor Output Voltage Frequency Harmonic distortion Overload capacity Battery Environment Noise level Operating temperature Relative humidity Standards and certification Safety Performance EMC Marking Pulsar EXtreme 00C 00 VA / 540 W Pulsar EXtreme 300C 300 VA / 080 W Single phase, 0 V / 40 V / 60 V to 84 V () 50/60 Hz (auto-selection) 0.95 Single phase, 30 V ± 3% () 50/60 Hz ± 5% (3) < 4% for linear loads, < 6% for non-linear loads 0% continuous, 30% for seconds, > 30% for.5 seconds 6 x V - 7 Ah, sealed lead-acid, maintenance free < 50 dba 0 to 40 C 0 to 90% (without condensation) 6 x V - 9 Ah, sealed lead-acid, maintenance free IEC/EN 6040--, EN 60950- (RD) IEC/EN 6040-3 EN 5009-/IEC 6040- class B IEC 6000-4-/-3/-4/-6-8/-, IEC 6000-3-/-3 CE, TÜV/GS, UL, cul, CB report () Values indicated for 33%, 66% and 00% of UPS rated output. () Adjustable from 00 V to 50 V using UPS Driver software. (3) Frequency-converter mode can be set using the UPS Driver software. 3400753EN/AA - Page 5

6. Appendices 6. Glossary Authorised voltage range for transfer to bypass if fault or overload Automatic bypass Automatic start following return of AC input power Backup time Bargraph Battery test Dialog box Double conversion Equipment Forced shutdown Percent load Personalisation Programmable outlets Remote Power Off Start on battery power UPS UPS ON / OFF via software Upper and lower voltage thresholds within which the UPS can operate on the automatic bypass in the event of a UPS fault or overload. Automatic switch controlled by the UPS, used to connect the equipment directly to the AC-power source in the event of a UPS failure or an overload. This function automatically starts the UPS when AC input power returns following shutdown at the end of the battery backup time. It can be enabled or disabled. Time that the connected equipment can operate on battery power. Device on the front panel indicating the percent remaining backup time or the percent load. Internal UPS test on battery status. A window in a computer program displayed for selection by the user of various options and parameter settings. The power supplied to the connected equipment is completely regenerated by continuous double conversion, i.e. the AC power from the AC-power source is rectified (AC - DC), then converted back (DC - AC) to AC power. Devices or systems connected to the UPS output. Ten-second interruption in the supply of power to the connected equipment following a system shutdown, even if AC input power returns during the interruption period. Ratio between the power drawn by the connected equipment and the total power that the UPS can supply. A number of UPS functions can be modified using the UPS Driver software to better meet the user s needs. Outlets that can be automatically shed during operation on battery power (a shedding time delay may be programmed using Solution-Pac software. External dry contact can be used to stop the unit, during an emergency situation for example. All power is removed from the load. This function makes it possible to energise the connected equipment even when AC input power is not available (operation exclusively on battery power). Uninterruptible Power Supply. It is possible to enable or disable use of UPS ON / OFF controls by the computersystem protection software. Page 6-3400753EN/AA

6. Appendices 6.3 Index A Remote power off... 9 Automatic bypass... 9-8-0 Automatic start... 7 B Bargraph... 9-5 Battery End of backup time... 6 Fault... 9-5 Low-battery warning... 7 Recycling... 4 Replacement... -3 Transfer to battery power... 6 Buttons... 8-9 Buzzer... 5-6 Buzzer shutdown... 9 C Connection Additional battery module... 8 Communications card... 3 RS3 communications port... 3 USB communications port... 3 Communication... 8-3 D Dimensions... 7 E Environment... -4 Excessive ambient temperature... 5 F Forced shutdown... 7 L Lamp test... 9 LEDs... 8-9 O ON LINE mode... 9 Overload... 9-8-0 P Personnalisation... 7 Battery... 7 By-pass... 8 On/Off conditions... 7 Output... 8 Programmable outlets... 8-9-5 S Sleep mode... 7 Automatic restart... 7-8 Start-up... 5 T Technical characteristics... 5 Transfer (forced)... 9 U UPS Driver... 7 UPS fault... 9-5-0- UPS ON / OFF via software... 7 UPS shutdown...8 W Web site... Weight... 7 3400753EN/AA - Page 7

Page 8-3400753EN/AA