Prevents Unscheduled Truck Departures

Similar documents
KSUPS + Solenoid Controlled Switch

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Motion Sensing Interlock User Manual - Original Language Version

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Motion Sensing Interlock User Manual - Original Language Version

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Data Sheet. AmLok.

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Installation and Operating Instructions

THE ENCLOSURE HARDWARE SUPPLIER

Installation and Operating Instructions

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

Operating Instructions

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

XCS Safety Interlock Selection

K-SERIES PUBLIC USE LIFT OPERATING INSTRUCTIONS

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

Valve Position Monitors

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Reliant Series Floor Scale

When using electrical equipment, basic safety precautions should always be followed including the following:

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

INSTALLATION INSTRUCTIONS PART NUMBER: AUDI A4 L4-2.0L C.A.R.B. E.O. # D-670-2

KSS Solenoid Controlled Switch

Non-illuminated Push Buttons

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Solenoid Locking Safety Switches

Big Hermet Pressure Switches

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Multi Key Powersafe Electrical Switch User Manual - Original Language Version

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Compact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Multi Key Solenoid Controlled Switch User Manual - Original Language Version

HS5D Miniature Interlock Switches

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

HS1C Interlock Switches with Solenoid

Midi Traffic Light installation manual TRAFFIC CONTROL ACCESSORIES

BETA Switching Switches and Light Indicators

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

SG-B1 SERIES / SG-A1 SERIES

S-SERIES PUBLIC USE OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Junction boxes for control, monitoring and control panel Ex tb

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

stainless steel Cover hinge The cover hinge is simply screwed to the box protection channel and to the edge fold. Model No. KL

Valve Position Monitors

Installation Instructions: K-Safe-T-Drift

Bolt Interlock with Safety Switch User Manual - Original Language Version

Technical Installation Manual

Easytork Solenoid Valve IOM

INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

INSTALLATION INSTRUCTIONS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

BYV Series Butterfly Valve Product Guide FLOW CONTROL

HS1E Series Full Size Solenoid Locking Switches

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Access Interlock with Safety Switch User Manual - Original Language Version

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Sealed Enclosures. Contact Blocks. Multiple Actuators

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MKey9-series Safety Interlock Switch with Guard Locking

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm

EB SERIES INSTRUMENT ENCLOSURES

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Weather Protective Devices

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Datasheet. Electrical Switching / Locking

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Door Interlock Switches

The LED Driver Expert

The Powermatic User Guide Test Sieve Shaker

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

CAUTION -TABLE OF CONTENTS- II. OPERATING INSTRUCTIONS

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

Pneumatic Isolation Module

PIL0478 ISSUE 01/ 07/16

Transmitters: Relay Valve

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Kuhnke Technical Data. Contact Details

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

Transcription:

INSTALLATION INSTRUCTIONS

Salvo Product Data Sheet Index Prevents Unscheduled Door Interlocks Salvo Manual Door Lock with Salvo Door Mounted Bolt Manual lock that ensures a dock door is locked while conditions are unsafe Air Brake Couplings Salvo Susie(UK)/Palm(EUR)/Gladhand(US) Lock Device to lock onto emergency air brake coupling which prevents unauthorised\accidental movement of an articulated trailer Salvo Manual Door Lock with Salvo Door Mounted Chain\Bolt Manual lock that ensures a dock door is locked while conditions are unsafe. The chain allows for limited movement of dock doors. Salvo Manual Door Lock with Electrical Interlock and Salvo Door Mounted Bolt Manual lock that ensures a dock door is locked while conditions are unsafe. The switch contacts can be used to power the dock equipment and switch traffic lights. Salvo Manual Door Lock with Electrical Interlock and Salvo Door Mounted Chain\Bolt Manual lock that ensures a dock door is locked while conditions are unsafe. The switch contacts can be used to power the dock equipment and switch traffic lights. The chain allows for limited movement of dock doors. Control Panel Salvo Control Panel Controls the opening and closing of dock doors once conditions are safe to do so. The SCP also contains connections for additional salvo products Salvo Automatic Door Lock with Salvo Door Mounted Bolt Automatic keyless door lock that is released when the Salvo key is trapped in the SCP. Salvo Automatic Door Lock with Salvo Door Mounted Chain\Bolt Automatic keyless door lock that is released when the Salvo key is trapped in the SCP. The chain allows for limited movement of dock doors.

Salvo Product Data Sheet Index Prevents Unscheduled Salvo Internal Traffic Lights Traffic lights provide the dock attendant an indication of the door open or locked condition Salvo External Traffic Lights Traffic lights provide an indication to the driver and\or yard jockey as to when the loading\unloading is complete so that the air brake coupling Lock may be removed. Salvo Traffic Light Sign Sign to warn drivers not to pull away until green light is shown on the traffic light system. Traffic Light Range Salvo Barrier Chain Floor Mounted Floor mounted barrier system to accept all types of door access lock when locking the door is not practical. Salvo Barrier Chain Wall Mounted Wall mounted barrier system to accept all types of door access lock when locking the door is not practical. Barrier Systems Salvo air brake coupling Lock Enclosure Storage box to be mounted on the warehouse wall where the air brake coupling is housed when it is not in use. Salvo air brake coupling Lock Enclosure Multiple Unit Unit to house numerous air brake couplings when they are not in use. (Made to order) Enclosures

PICTORIAL REPRESENTATION: (for reference only) Salvo Susie (UK) Lock FITTING & OPERATING INSTRUCTIONS TECHNICAL SPECIFICATION IMPORTANT: Please retain this document & ensure that warehouse personnel, supervisors & drivers are trained on Salvo operation. GENERAL: The Castell Salvo-Susie is suitable for the UK emergency air brake couplings. Salvo prevents the unauthorised or accidental movement of an articulated trailer. Salvo for (UK) BS AU138b.C type coupling. OPERATION: Articulated lorry driver arrives at the specified loading bay and reverses the trailer into position, applies the brakes and switches off the engine. The Salvo-Susie is collected from the bay. The operator removes the Red emergency airline from the trailer bulkhead coupling, this action applies the air brakes and inhibits the movement of the trailer. The Salvo-Susie is fitted onto the now exposed emergency airline coupling. After successful fitment, a Castell coded key is released from the Salvo-Susie, locking the unit firmly onto the coupling. The fitting of Salvo-Susie prevents the airline being re-applied. From here the key is taken to the loading bay and used to open the bay door. Please refer to the system options shown within this document. Site working practices will also need to be taken into consideration. TECHNICAL SPECIFICATION Weight: Salvo-Susie (UK) 1.1 kg Working temperature: Min -25ºC (ice free) Max Q type +55 ºC Material:, brass & light alloy Housing material: Lock material: Brass Standards: Conforms with:- (UK) BS AU138b.C type coupling LOST / REPLACEMENT KEYS: Records of key & lock coding will be maintained at Castell. If you lose a key or require replacement keys then please contact the Castell sales team for advise. You may be asked to complete a disclaimer to take responsibility for lost / replacement keys.

Fitting Salvo-Susie onto a (UK) BS AU138b.C type coupling 1) Remove Red emergency brake line hose & offer Salvo-susie up to the coupling on the trailer bulkhead. 2) Salvo-susie is pushed over the coupling, ensuring that it is fully engaged. 3) Turn the trapped key anticlockwise and remove. 4) The salvo-susie interlock is securely fitted preventing any re-engagement of the emergency airline..

Salvo Gladhand (US) / Palm (Europe) Lock INSTALLATION & OPERATING INSTRUCTIONS. TECHNICAL SPECIFICATION IMPORTANT: Please retain this document & ensure that warehouse personnel, supervisors, yard jockeys & drivers are properly trained on Salvo operation. GENERAL: Salvo prevents the unauthorised or accidental movement of an articulated trailer. OPERATION: Salvo for ISO 1728-1980 and SAE J318 glad hand type coupling Salvo for (EU) ISO 1728-1980 Palm type coupling. Articulated truck driver arrives at the specified loading dock and reverses the trailer into position, applies the brakes and switches off the engine. The Salvo is located at the the dock or another place based on the application. The operator removes the emergency airline from the trailer bulkhead Gladhand/Palm coupling. This action applies the air brakes and inhibits the movement of the trailer. The Salvo Gladhand/Palm Lock is attached to the exposed emergency Gladhand/Palm airline coupling. When attached, a Castell coded key is released from the Salvo, locking the unit firmly onto the coupling. The attaching of Salvo prevents the airline being reconnected. The key is used the open the dock door lock. There are several system options available based on the application. TECHNICAL SPECIFICATION Weight: Working temperature: Material: Housing material: Lock material: Standards: Size: 3.5 lbs (1.6 kg) Min -20º F(-30ºC), Max +130 ºF (+55 ºC), brass & Aluminum alloy Conforms with:- ISO 1728-1980 and SAE J318 type coupling Manufactured to ISO 9001 2000 quality standards. 7 ¾ (95mm) long x 2 ¾ (68mm) diameter LOST / REPLACEMENT KEYS Records of key & lock coding will be maintained at Castell. If you lose a key or require replacement keys please contact the local Castell distributor for advice. You may be asked to complete a disclaimer to take responsibility for lost / replacement keys.

Fitting Salvo onto a Gladhand (ISO 1728-1980 and SAE J318) type coupling OR Salvo for (EU) ISO 1728-1980 Palm type coupling 1) Remove emergency air line brake hose (usually Red). 2) Attach Salvo to the emergency Gladhand coupling on the trailer bulkhead. 3) Rotate and lock Gladhand coupling into place 4) Push the Salvo sleeve towards the coupling. 4) Turn the key counter-clockwise and remove. 5) The Salvo is securely attached, preventing any re-connection of the airline.

Salvo Control Panel IMPORTANT: Installation should be carried out by a qualified electrician. Control Panel should be mounted using anti-tamper fasteners to prevent unauthorized removal. OPERATION: For Manual Doors When the dock door lock bolt is in the closed position, the key is free & the Green LED is ON. In order to unbolt the door lock, the Salvo key must be inserted into the control panel and rotated clockwise, this action closes the switch contacts and enables the unbolting of the dock door. The Key is trapped when the door is unbolted and the LED light on the control panel is RED. Releasing of the key will only be allowed when the door is in the closed position and the door bolt locked. For Power Doors When the dock door is in the closed position, the key is free & the Green LED is ON. In order to open the dock door, the Salvo key must be inserted into the control panel and rotated clockwise, this action closes the switch contacts and opens the dock door. The Key is trapped when the door is open and the LED light on the control panel is RED. Releasing of the key will only be allowed when the door is in the closed position and the door bolt locked. Boxes should be mounted with size 10 or 12 x 1 (25mm) screws or equivalent & ¼ washers. Wall plugs should be used for solid brick & a self tapping type can be used for metal cladding. 4 screws & raw plugs are required to mount the box. The box should be aligned using a spirit level. The box mounting holes should be sealed with silicone. Cables should be connected to the switch & solenoid in accordance with the applicable wiring schematics, see attached. Ensure that the unit is wired for ground continuity. Check all input supply voltages with component ratings prior to powering up. Cabling can be pre wired type or flexible conduit with wiring all conforming to wiring regulations. All wiring should be neat & conduit must be clipped to the wall. All wires to be terminated using appropriate crimps & numbered clearly with ferrules. Lock portion comes complete with protective flip cap. All installation screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Working temp. Min: -22 F (-30 ºC) Max: +130 F (+55 ºC) Weight 2.5 lbs (1.1Kg) Related standards IEC 947/3, VDE 0660 part 107/09.82 Manufactured to IS0 9001 2000 quality standards. Switch Approvals CSA & UL Enclosure Front panel mounting only. Nema 4x protection. Supply voltage 220 V AC UK & EUR & 110V AC - US Size 8 (200mm) wide x 12 (300mm) high x 6 (150mm) deep.

Salvo Control Panel 12 13 14 15 16 17 18 19 20 21 22 11 10 Prevents Unscheduled DOOR STOP RELAY TO BE WIRED ACROSS EXSISTING WIRING SCHEMATIC FOR SCP WITH POWERED DOOR USING THE EXISTING 24V AC DOOR STOP SIGNAL 5 KS20 KEY FREE 6 KEYED OVERIDE SWITCH (Available on request) DOOR OPERATOR INTERLOCK INTERUPTS DOOR SUPPLY 7 VEHICLE RESTRAINT SYSTEM INTERLOCK 8 9 VOLT FREE CONTACTS FOR TRAFFIC LIGHT EXTERNAL \ INTERNAL SPARE DOOR STOP RELAY TRAFFIC LIGHT CONTROL 220v 110V AC AC - EUR OR 110V AC - US EXSISTING 24V CONTACTS SIGNALLING DOOR CLOSED STATUS WITHIN MOTOR CONTROL PANEL DOCK LEVELER CONTROL INTERLOCK INTERUPTS DOCK SUPPLY 1 2 3 4 GND L N INPUT SUPPLY 220v AC - EUR OR 110V AC - US CONNECT TO MAIN SUPPLY

Salvo Control Panel 12 13 14 15 16 17 18 19 20 21 22 11 10 9 8 7 AUTO DOOR LOCK SIGNAL TO OPERATE AUTO DOOR LOCK KEYED OVERIDE KEYED SWITCH OVERIDE (Available SYSTEM on request) INPUT SUPPLY 110V AC CONNECT UP TO MAINS SUPPLY 6 3 RED 1 SIGNAL FROM AUTO DOOR LOCK TO INDICATE STATE OF DOOR VEHICLE RESTRAINT KS20 KEY FREE SYSTEM INTERLOCK 2 GND L N 5 4 Prevents Unscheduled YELLOW BLACK GREEN BLUE COMMON COMMON NC NO RED GREEN VOLT FREE CONTACTS FOR TRAFFIC LIGHT WIRING SCHEMATIC FOR SCP WITH MANUAL DOOR SPARE USING SALVO AUTOMATIC DOOR LOCK (SADL) EXTERNAL EXTERNAL \ INTERNAL TRAFFIC LIGHT CONTROL 220v 110V AC AC - EUR OR 110V AC - US DOCK LEVELER CONTROL CONTROL INTERLOCK 220v AC - EUR OR 110V AC - US INTERUPTS DOCK SUPPLY

Salvo Control Panel 12 13 14 15 16 17 18 19 20 21 22 11 10 9 Prevents Unscheduled COMMON KEYED OVERIDE SWITCH SYSTEM (Available on request) INPUT SUPPLY 110V AC CONNECT UP TO MAINS SUPPLY DOOR OPERATOR INTERLOCK DOOR 1 INTERUPTS DOOR SUPPLY VEHICLE RESTRAINT SYSTEM INTERLOCK LIMIT SWITCH CLOSES TO INDICATE DOOR CLOSED KS20 KEY FREE 2 GND L N 3 4 5 6 7 8 COMMON NC NO GREEN RED WIRING SCHEMATIC FOR SCP WITH POWERED DOOR USING AN AUXILIARY LIMIT SWITCH ON DOOR OR EXISTING SPARE DOOR SENSOR CONTACTS VOLT FREE CONTACTS FOR TRAFFIC LIGHT EXTERNAL EXTERNAL \ INTERNAL TRAFFIC LIGHT SPARE CONTROL 220v 110V AC AC - EUR OR 110V AC - US DOCK CONTROL LEVELER CONTROL INTERLOCK INTERLOCK 220v AC - EUR OR 110V AC - US INTERUPTS DOCK SUPPLY

SALVO MANUAL DOOR LOCK 118.38 [4 11/16"] 60.00 [2 3/8"] 81.00 [3 3/16"] 58.14 [2 5/16"] 48.13 [1 7/8"] 80.00 [3 1/8"] 20.00 [13/16"] 20.00 [13/16"] 120.00 [4 3/4"] 40.00 [1 9/16"] 74.04 [2 15/16"] 92.04 [3 5/8"] 212.00 [8 3/8"] 115.47 [4 9/16"] 115.47 [4 9/16"] 212.00 [8 3/8"] 92.04 [3 5/8"] 74.04 [2 15/16"] 120.00 [4 3/4"] 20.00 [13/16"] 20.00 [13/16"] 80.00 [3 1/8"] 60.00 [2 3/8"] 48.13 [1 7/8"] 40.00 [1 9/16"] 58.14 [2 5/16"] 81.00 [3 3/16"] 118.38 [4 11/16"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: This interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when the key is inserted into the lock and turned. The key becomes trapped in the lock when the bolt is removed and can only be removed after the door is closed and the bolt re-inserted again. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws\bolts. A clearance hole needs to be cut out in the door guide track ( 38mm) 1 1/2 for lock bolt, see installation pictures. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Bolt length 13 (330mm) x 5 (125mm) wide Lock 2 ¾ (68mm) wide x 3 ½ (90mm) long x 2 ½ (63mm) deep Weight 2.5 LBS (1.1 Kg) Working temperature Min: -40ºF (-40ºC) Max: + 280 ºF (+140 ºC) Bolt material Housing material Lock material

SALVO MANUAL DOOR LOCK 118.38 [4 11/16"] 60.00 [2 3/8"] 81.00 [3 3/16"] 58.14 [2 5/16"] 40.00 [1 9/16"] 48.13 [1 7/8"] 55.00 [2 3/16"] 127.00 [5"] 107.00 [4 3/16"] 75.00 [2 15/16"] 74.04 [2 15/16"] 92.04 [3 5/8"] 212.00 [8 3/8"] 115.47 [4 9/16"] 115.47 [4 9/16"] 212.00 [8 3/8"] 92.04 [3 5/8"] 74.04 [2 15/16"] 55.00 [2 3/16"] 127.00 [5"] 107.00 [4 3/16"] 75.00 [2 15/16"] 60.00 [2 3/8"] 48.13 [1 7/8"] 40.00 [1 9/16"] 58.14 [2 5/16"] 81.00 [3 3/16"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: This interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when the key is inserted into the lock and turned. The key becomes trapped in the lock when the bolt is removed and can only be removed after the door is closed and the bolt re-inserted again. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws\bolts. No hole is required in the guide track (as with the SDMB version) because the chain goes around the guide track rather than through it. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Weight Working. temperature Bolt material Housing material Lock material Lock 2 ¾ (68mm) wide x 3 ½ (90mm) long x 2 ½ (63mm) deep 2.5 LBS (1.1 Kg) Min: -40ºF (-40ºC) Max: + 280 ºF (+140 ºC)

SALVO MANUAL DOOR LOCK - ELECTRICAL INTERLOCK 123.83 [4 7/8"] Ø9.60 [Ø3/8"] 25.00 [1"] 58.14 [2 5/16"] 119.93 [4 3/4"] 40.00 [1 9/16"] 15.00 [9/16"] 33.18 [1 5/16"] 162.00 [6 3/8"] 212.00 [8 3/8"] 195.24 [7 11/16"] 20.00 [13/16"] 20.00 [13/16"] 80.00 [3 1/8"] 70.00 [2 3/4"] 20.00 [13/16"] 20.00 [13/16"] 119.93 [4 3/4"] 195.24 [7 11/16"] 212.00 [8 3/8"] 162.00 [6 3/8"] 36.55 [1 7/16"] 36.55 [1 7/16"] 33.18 [1 5/16"] 15.00 [9/16"] 40.00 [1 9/16"] 58.14 [2 5/16"] 60.00 [2 3/8"] 70.00 [2 3/4"] 80.00 [3 1/8"] 25.00 [1"] 60.00 [2 3/8"] 123.83 [4 7/8"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: This interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when the key is inserted and turned. Turning the key clockwise operates the electrical contacts within the interlock. With the bolt removed the key is trapped and can only be removed after the door is closed and the bolt re-inserted. The switch contacts can be used to power up the dock equipment & switch traffic lights. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws/bolts. A clearance hole needs to be cut out of the door guide track ( 38mm) 1 1/2 for lock bolt, see installation pictures. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Bolt length 13 (330mm) x 5 (125mm) wide Lock 2 ¾ (68mm) wide x 8 3/8 (218mm) long x 2 ½ (63mm) deep Weight 1.3 Kg Temperature range Min: -20 F (-30 C) Max: +175 F (+80 C). Bolt material Stainless Steel Housing material Aluminum Lock material SWITCH CONTACTS Ingress Protection Nema 4X Mechanical lifecycle 200,000 electrical operations Switch Standards IEC 947-5-1. Approvals VDE,UL, & CSA. Cable gland M20 (3/4 ) Current 10 A Max voltage 500V.

SALVO MANUAL DOOR LOCK - ELECTRICAL INTERLOCK 123.90 [4 7/8"] Ø9.60 [Ø3/8"] 127.00 [5"] 58.14 [2 5/16"] 33.18 [1 5/16"] 25.00 [1"] 55.00 [2 3/16"] 107.00 [4 3/16"] 75.00 [2 15/16"] 40.00 [1 9/16"] 195.24 [7 11/16"] 15.00 [9/16"] 212.00 [8 3/8"] 162.00 [6 3/8"] 36.55 [1 7/16"] 36.55 [1 7/16"] 33.18 [1 5/16"] 162.00 [6 3/8"] 212.00 [8 3/8"] 195.24 [7 11/16"] 15.00 [9/16"] 40.00 [1 9/16"] 58.14 [2 5/16"] 60.00 [2 3/8"] 55.00 [2 3/16"] 127.00 [5"] 107.00 [4 3/16"] 75.00 [2 15/16"] 25.00 [1"] 60.00 [2 3/8"] 123.90 [4 7/8"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: This interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when the key is inserted and turned. Turning the key clockwise operates the electrical contacts within the interlock. With the bolt removed the key is trapped and can only be removed after the door is closed and the bolt re-inserted. The switch contacts can be used to power up the dock equipment & switch traffic lights. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws/bolts. No hole is required in the guide track (as with the SDMB version) because the chain goes around the guide track rather than through it. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Bolt length 13 (330mm) x 5 (125mm) wide Lock 2 ¾ (68mm) wide x 8 3/8 (218mm) long x 2 ½ (63mm) deep Weight 1.3 Kg Temperature range Min: -20 F (-30 C) Max: +175 F (+80 C). Bolt material Stainless Steel Housing material Aluminum Lock material SWITCH CONTACTS Ingress Protection Nema 4X Mechanical lifecycle 200,000 electrical operations Switch Standards IEC 947-5-1. Approvals VDE,UL, & CSA. Cable gland M20 (3/4 ) Current 10 A Max voltage 500V.

SALVO AUTOMATIC DOOR LOCK 123.83 [4 7/8"] Ø9.60 [Ø3/8"] 25.00 [1"] 80.00 [3 1/8"] 70.00 [2 3/4"] 20.00 [13/16"] 20.00 [13/16"] 119.93 [4 3/4"] 58.14 [2 5/16"] 40.00 [1 9/16"] 195.24 [7 11/16"] 212.00 [8 3/8"] 162.00 [6 3/8"] 15.00 [9/16"] 33.18 [1 5/16"] 36.55 [1 7/16"] 36.55 [1 7/16"] 33.18 [1 5/16"] 162.00 [6 3/8"] 212.00 [8 3/8"] 195.24 [7 11/16"] 15.00 [9/16"] 40.00 [1 9/16"] 60.00 [2 3/8"] 119.93 [4 3/4"] 20.00 [13/16"] 20.00 [13/16"] 70.00 [2 3/4"] 80.00 [3 1/8"] 58.14 [2 5/16"] 25.00 [1"] 60.00 [2 3/8"] 123.83 [4 7/8"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: The interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when a signal has been received from the key being inserted and turned clockwise in the Salvo Control Panel. When the green light illuminates on the door lock, the operating handle can be pulled downwards and the lock bolt turned and released. The switch contacts can be used to power up the dock leveler & switch traffic lights. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws\bolts. A clearance hole needs to be cut out of the door guide track ( 38mm) 1 1/2 for lock bolt, see installation pictures. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Bolt length 13 (330mm) x 5 (125mm) wide Lock 2 ¾ (68mm) wide x 8 3/8 (218mm) long x 3 ½ (90mm) deep Weight 1.3 Kg Temperature range Min: 32 F (0 C), Max: +175 F (+80 C). Mechanical lifecycle 200,000 electrical operations Bolt material Stainless Steel Housing material Aluminum Lock material Ingress Protection Nema 4X Green Yellow Black Switch Standards IEC 947-5-1. Blue Red Approvals VDE,UL, & CSA. White -Unused Cable gland M20 Current 10 A Max voltage 500V. Actuator voltage 24V ac or DC NOTE: This product is fitted with 26 ft (8m) of pre-wired cable.

SALVO AUTOMATIC DOOR LOCK 123.90 [4 7/8"] 127.00 [5"] 107.00 [4 3/16"] 58.14 [2 5/16"] 40.00 [1 9/16"] 15.00 [9/16"] 33.18 [1 5/16"] 36.55 [1 7/16"] Ø9.60 [Ø3/8"] 25.00 [1"] 55.00 [2 3/16"] 75.00 [2 15/16"] 25.00 [1"] 60.00 [2 3/8"] 195.24 [7 11/16"] 212.00 [8 3/8"] 162.00 [6 3/8"] 36.55 [1 7/16"] 33.18 [1 5/16"] 162.00 [6 3/8"] 212.00 [8 3/8"] 195.24 [7 11/16"] 15.00 [9/16"] 40.00 [1 9/16"] 58.14 [2 5/16"] 60.00 [2 3/8"] 123.90 [4 7/8"] 55.00 [2 3/16"] 127.00 [5"] 107.00 [4 3/16"] 75.00 [2 15/16"] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: The interlock prevents the opening of the dock door by the means of a locked bolt which can be released only when a signal has been received from the key being inserted and turned clockwise in the Salvo Control Panel. When the green light illuminates on the door lock, the operating handle can be pulled downwards and the lock bolt turned and released. The switch contacts can be used to power up the dock leveler & switch traffic lights. The housing of the interlock should normally be mounted to the L shaped mounting bracket supplied using (M6) ¼ fasteners. The bracket should be mounted to the door frame using 2 - (M6) ¼ x (80mm) 3 long bolts, (M6) ¼ nuts & (M6) ¼ washers & spacers provided. Locking bolts should be mounted on the door using 8 - (4mm) 5/32 pop rivets or mounting screws\bolts. No hole is required in the guide track (as with the SDMB version) because the chain goes around the guide track rather than through it. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION Size Bolt length 13 (330mm) x 5 (125mm) wide Lock 2 ¾ (68mm) wide x 8 3/8 (218mm) long x 3 ½ (90mm) deep Weight 1.3 Kg Temperature range Min: 32 F (0 C), Max: +175 F (+80 C). Mechanical lifecycle 200,000 electrical operations Bolt material Stainless Steel Housing material Aluminum Lock material Ingress Protection Nema 4X Green Yellow Black Switch Standards IEC 947-5-1. Blue Red Approvals VDE,UL, & CSA. White -Unused Cable gland M20 Current 10 A Max voltage 500V. Actuator voltage 24V ac or DC NOTE: This product is fitted with 26 ft (8m) of pre-wired cable.

SALVO INTERNAL TRAFFIC LIGHTS 130.00 [5 1 8 "] LAMP MOUNTING 2 HOLES Ø22 65.00 [2 9 16 "] 115.00 [4 1 2 "] 4 OFF Ø5 BLIND MOUNTING HOLES Ø20 GLAND MOUNTING HOLES Ø20 65.00 [2 16 9 "] 28 [1 1 8 "] 28 [11 8 "] 115.00 [4 1 2 "] 130.00 [5 1 8 "] 30.00 [1 3 16 "] 65 [2 9 16 "] 99 [3 7 8 "] IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: These lights are mounted inside the warehouse to provide an indication to the dock attendant. A Red light means that the door cannot be opened. A Green light means that the door can be opened. Remove lid and mount to a flat surface using 4 suitable mounting screws. Place the back of the enclosure box in the desired position and use mounting holes as a drilling template. Cables should be connected to the switch via the cable gland in accordance with the applicable wiring schematics. Ensure that the unit is wired for ground continuity. 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Control Panel Common Green Light Red Light Internal Traffic Light Unit TECHNICAL SPECIFICATION: Operating voltage 220V AC UK AND EUR OR 120v AC -US Connections:- Refer to wiring schematic. Temperature range Min: -20 F (-30 C). Max: +175 F (+80 C). Housing material Polycarbonate Ingress Protection Nema 4X Size 5 1/4 (130mm) wide x 5 1/4 (130mm) high x 4 (100mm) deep.

SALVO EXTERNAL TRAFFIC LIGHTS IMPORTANT: Installation should be carried out by a qualified electrician. Please retain this document OPERATION: These lights are mounted outside the warehouse on the loading dock wall and are designed to provide an indication to the driver and/or yard jockey. A Red light means that the Salvo air brake coupling Lock cannot be removed and the truck driven away. A Green light means that the key can be retrieved, the Air Brake Coupling can be removed and the truck driven away. Choose location that can be accessed by your power source is clearly visible to the driver. The power source connection can be made either through the underside of the housing by removing the plug and using the ½ ETW fitting provided, or through steel back plate. An ETW fitting may be used on the back panel as well. Using the housing as a template, drill 4 holes. If you are mounting to a brick or masonry wall, we recommend sizing the holes to accept ¼ lag shields. For mounting to a surface with access to the rear you may mount with machine screws, washers and nuts or any fastener system you find convenient and size the holes accordingly. Mount unit to wall using the gasket provided and mounting hardware. Make the connections to the unit using suitable wire nuts or compression fittings, following the schematic diagrams provided. Do not make any changes to the wiring inside the unit. SCP Unit SETL Unit 22 21 20 19 18 15 16 17 14 13 12 11 10 9 8 7 Green White Black Red Black RED Red Red White (Ground) 4 56 3 2 1 Black (Labelled Green) GREEN Red TECHNICAL SPECIFICATION: Housing Safety Yellow Polypropylene Power Source 220V AC UK AND EUR OR 115V AC - US Lens diameter 41/4" Dimensions 113/8"H x 63/8"W x 33/4"D Shipping weight 2 lbs.

SALVO AIR BRAKE COUPLING LOCK ENCLOSURE The storage boxes should be mounted on the warehouse walls with size 10 or 12 x 1 (25mm) screws or equivalent & 1/4 washers. Wall plugs should be used for solid brick & a self tapping screws can be used for metal cladding. 4 screws & wall plugs are required to mount boxes. All boxes to be aligned using a spirit level. The box mounting holes should be sealed with silicone if mounted outside. All mounting screws to be plated mild steel as a minimum. TECHNICAL SPECIFICATION: Specify Lock type:- Temperature range Housing material Ingress Protection Size T bar handle lockable or not lockable Min: -20 F (-30 C). Max: +175 F (+80 C). Mild steel, powder coated. Nema 4X 8 (200mm) wide x 12 (300mm) high x 6 (150mm) deep. SALVO AIR BRAKE COUPLING LOCK ENCLOSURE (design and build to order) MULTIPLE UNIT Example:-

SALVO BARRIER CHAIN - FLOOR MOUNTED The barrier system is designed to accept all types of door access lock. Each post should be fitted securely to the floor with 4 - (M12) ½ x (50mm) 2 raw bolts. The post should be positioned in such a way to avoid being hit with the forklift trucks. The chain height can be adjusted to suit each application. The recommended height for the center of the chain is approx 3FT (1m). The released chain and bolt should be stored inside the post during loading & unloading. R10 [R 3 8 "] TYP. 140 [5 1 2 "] 100 [3 15 16 "] 100 [3 15 16 "] 140 [5 1 2 "] Ø75 x 5 TUBE BASE PLATE 4 HOLES Ø13 IN BASE PLATE MATERIAL: 6mm ST. STL. 303-316 TECHNICAL SPECIFICATION: Chain Temperature range Housing material Post sizes Mild steel, painted black & yellow 12 3 (3.75m) Min: -20 F (-30 C). Max: +175 F (+80 C). Mild steel, powder coated yellow. 3 (75mm) steel section by 4ft (1200mm) high.

SALVO BARRIER CHAIN - WALL MOUNTED Mounting Bracket for SMDL Mounting Bracket for SDMC (Mounting Bracket for SMDL EI and SADL Also available) 250.00 [9 13 16 "] 70.00 [2 3 4 "] 250.00 [9 13 16 "] 300.00 [11 13 16 "] 120.00 [4 3 4 "] 120.00 [4 3 4 "] 4 HOLES Ø13.00 [Ø 1 2 "] The barrier system is designed to accept all types of door access lock. Each bracket should be fitted securely to the wall with 4 - (M12) ½ x (50mm) 2 rawl bolts. The brackets should be positioned in such a way to avoid being hit with the forklift trucks. The chain height can be adjusted to suit each application. The recommended height for the center of the chain is approx 3FT (1m). TECHNICAL SPECIFICATION: Chain Temperature range Housing material Post sizes Mild steel, painted black & yellow 12 3 (3.75m) Min: -20 F (-30 C). Max: +175 F (+80 C). Mild steel, powder coated yellow. 3 (75mm) steel section by 4ft (1200mm) high.

SALVO TRAFFIC LIGHT SIGN 6 [ 1 4 "] 254 [10"] 6 FIXING HOLES Ø6.5 (1\4 ) 710.00 [2'-4"] 96 [3 3 4 "] 294.50 [11 5 8 "] 25 [1"] 204.00 [8 1 16 "] 294.50 [115 8 "] The Traffic Light Sign is designed to warn drivers not to pull away until the Green light is on. It should be located in a highly visible location, close to the Salvo External Traffic Lights. The sign should be fitted securely to the wall with 6 x 1\4 screws. TECHNICAL SPECIFICATION: Material Flexible Plastic Thickness 6mm (1\4 )