Valve Portfolio Slide 0
Valve Portfolio by Function Valves for Isolation 1) IsoPlug Lift Plug Valve 2) Y-Globe Valve 3) HP Angle Isolation Valve 4) Special Gate Valve Choke Valves 5) Choke valves Control Valves 6) Angle Control Valves 7) Multistage Control valve 8) Cage Style Control Valve 9) Y Globe Control Valve 10) Gasification Control Valves 11) Automatic Recirculation Valve Switching Valves 12) Diverter Valves 13) SwitchPlug Valve Safety Related Valves 14) Line Blind System Cam-Set 15) Changeover Valve 16) Emergency Tank Safety Valves Drain & Injection Valves 17) Ram Bottom Outlet Valve 18) Disk Bottom Outlet Valve 19) Injection Valves Sampling and Rinsing Valves 20) Sampling Systems 21) Spray Rinse Valve Slide 1
Valves for Isolation Slide 2
1) IsoPlug (Special Design Lift Plug Valve) Application: Isolation valve for high temperature processes Process: Delayed coking, ethylene cracking and FCC Key Features: 1 (DN25) to 40 (DN 1000) Integral Double Block & Bleed Design Protected Valve Seat (PVS) Unique 3 line Coking Defence System (3 CDS) Dual motor actuation no plug sticking Flushing only required for short periods Slide 3
30 inch ASME 300 Lift Plug Valve with integral drain valve Slide 4
2) Y-Globe Valve Application: Isolation valve for non-clogging applications Process: Refinery, chemical, & petrochemical processes Key Features: 1 (DN25) to 36 (DN 900) ASME 150# to 2500# pressure rating Optimised flow body design low pressure drop Zero leakage to atmosphere Class VI leakage tight shut off to process Dead space free back seating option Disc grinding option to clean seat Booster pump Y Globe isolation valve in Hydrocracking unit Control type Y-Globe also available Slide 5
Y globe Valve with back seating Y globe Valve piston design Y globe Valve with disc grinding Slide 6
3) High Pressure Angle Valve Application: Process: To isolate high pressure media flow or act as an emergency shutdown valve Most chemical, refinery, polymer, urea and petrochemical processes Key Features: 1 (DN25) to 20 (DN 500) Forged, cast or weld construction Pressure class to ASME 2500# standard Positive sealing with stuffing box Back seating enhances seal to atmosphere Top side entry for easier maintenance Locking device for safety Slide 7
4) Y-Globe Valve Application: Process: Isolation valve for non-clogging applications Refinery, chemical, & petrochemical processes Key Features: 1 (DN25) to 36 (DN 900) ASME 150# to 2500# pressure rating Optimised flow body design low pressure drop Zero leakage to atmosphere Class VI leakage tight shut off to process Dead space free back seating option Disc grinding option to clean seat Control type Y-Globe also available Slide 8
5) Special Gate Valves Slide gate valve 40 standard gate Slide 9
Choke Valves Slide 10
6) Choke Valves Application: Throttling and control of high pressure drops Process: Key Features: Refinery, urea and petrochemical DN 25 (1 ) to DN 250 (10 ) Pressure rating PN 160 (ASME 1500#) to PN 400 (ASME 2500#) as standard Guaranteed fixed Cv value (0.29 to 1000) Zero leakage across the seat Linear or equal % control characteristics available Piston/Ram design or disc with a back seating option Customised choke design Available in most materials, special coatings, full stelliting, and solid Tungsten Carbide option Slide 11
Choke Valves High pressure choke valve 71KS Actuated choke valve 71ES Start up choke valve 71KS Slide 12
Control Valves Slide 13
7) Angle Control Valves Application: For pressure let down, flow and level control Process: Refinery, chemical, polymer, petrochemical & mineral processing Key Features: DN 25 (1 ) to DN 900 (36 ) Inlet angle 45, 60 or 90 Accelerating body geometry design X-Flash (Model 74BS) & Tough Flash (74CS) designs Linear, equal % and SchuF bell X 3 curve Integral plug and stem Available in most materials, special coatings and trim Slide 14
SchuF Severe Service Experience SchuF has provided valves for all of the processes listed below. Theses severe services typically combine high temperature, high pressure drops (Delta P) and have a relatively high media solids content. Severe Service Variables for Control Valves Liquefaction Gasification Hydrocracking Mineral Processing PTA 0 50 100 150 200 250 300 350 400 450 500 Solids content (%) Temperture ( C) Pressure drop (bar) Slide 15
X-Flash Angle Control Valve Model 74BS Angle Control Valves X-Flash design (Model 74 BS) Flow to open Slide 16
ToughFlash Angle Control Valve Model 74CS Model 74CS for HHPS level control application - with solid Tungsten Carbide trim Model 74CS for Autoclave letdown applications - with ceramic choke tube Slide 17
8) Multi-S Control Valve- Model 74MS Application: High Pressure Letdown Valve model 74MS Multistage valve design features: Cast or single block forged body available 2, 3 or 4 staged pressure reduction disc design self cleaning True Equal % characteristics Higher SchuF Cv values (1 to 350) allows for greater plant capacity and better pump protection Large outlet chamber to reduce velocities Disk opening direction eliminates plugging by catalyst fines Easy to replace severe service trim Slide 18
9) Cage Release Control Valve Model 74KS Applications: Flow, Letdown, & Surge Control Valve design features: Multi hole cage disk design variety of hole placement designs to achieve accurate flow characteristics and noise attenuation Class VI (API 598) shut off is achieved, eliminating unacceptable leakage Stainless steel or special hard metal materials can be used Linear or Equal % control contour Available with fast opening actuators, and smart positioners Easy to replace trim parts Cage trim design Slide 19
10) Y- Globe Control Valve Model 50SK Application: In line flow control and letdown applications Valve design features: High throughput and good controllability Suitable for high pressure (ASME 2500# plus) and high temperature (700 C) applications Disc or piston variant Equal %, or linear characteristics Normal choke or custom control Zero leakage sealing performance Slide 20
11) Gasification Control Valves Black Water let down (under liquid level) Dry Coal feed control Black Water let down ( from above) Black Gas let down (lock hopper) Slide 21
12) Automatic Recirculation (ARC) Valve Application: Process: To protect centrifugal pumps by assuring minimum flow through the pump at all times All major processes using centrifugal pumps Key Features: Up to 16 (DN 400) standard and ASME 2500# Modular design Automatic bypass operation Non return function Pressure modulation in bypass Self cleaning bore High pressure (to 4500#) and Offshore designs Slide 22
Automatic recirculation valve (ARC) Recirculation flow control valve Outlet Bypass Inlet (Pump side) Slide 23
Switching Valves Slide 24
13) Diverter Valves Application: To split, combine, switch or isolate media Process: Polymer and refinery processes Key Features: 1 (DN25) to 20 (DN 500) 3, 4, 5 and multiport designs Ideal to replace multiple ball valves and T-pieces Dead-space free design eliminates the need for back flushing Positive sealing in enclosed body Can be used to combine multiple valve functions and save plant space Weld end, flanged or hub connections Slide 25
3 Way R Type Combination Diverter Model 45RK One inlet and two outlets R(right angle) design, Ram type Metal to metal sealing Dead space free Full bore unimpeded flow Stuffing box seal to atmosphere Fully jacketed Slide 26
Replacing T pieces & Ball valves with Diverters Dead space area The clean alternative o Diverter valves seal at the take-off point, eliminating dead space o Continuous back flushing is not required. o Design more compact T-piece o Very advantageous, especially when 3 or more parallel outlets are required. Standby Valve Closed Ball Valve 2 Open The old solution Normally T pieces and ball or plug valves are used to isolate the standby valve, resulting in dead space from the takeoff point If the liquid is a solid containing slurry, the solids can settle in the ball valve and in the pipe. One solution is the use back flushing, i.e. to continuously flush the dead lag back into the main line. However this adds cost and can considerably reduce plant throughput. Slide 27
Four Way Diverter Valve Model 42 Five Way Diverter Valve Model 47 Slide 28
4 Way Diverter (Star design) Patented tangential star design Model 47DK One inlet and three outlets Outlets in one plane to inlet at right angles Star design, Ram type Metal to metal sealing Replaceable seats Dead space and slow space free Contoured, non rotating pistons unimpeded flow Stuffing box seal to atmosphere Completely jacketed Slide 29
Pump Switching Diverter Valves 2-6 Way Feed Pump Diverter Valve o In many plants several pumps are used in parallel. Of these one is always in standby allowing for repair or maintenance without affecting plant performance. o Normally T pieces and ball or plug valves are used to isolate the standby valve, resulting in dead space from the takeoff point to the isolation valve. Diverter valves eliminate this dead space o Flushing / Cleaning / Draining valves can be included in the body of the diverter to optimise cleaning Slide 30
14) SwitchPlug Valve Application: To switch and isolate media between two or more outlets Process: Refinery and petrochemical processes Key Features: 1 (DN25) to 24 (DN 600) 2/3 outlets (A, B and By-pass) & one inlet L configuration with 3 outlets @ 120, or a T with two 90 and one 180 angle outlet Integral double block and bleed Diverse flushing & draining options Dual motor actuation no sticking Feature rich actuators for flow regulation Slide 31
SwitchPlug outlets cross section from above, inlet from below Bypass Outlet Slide 32
Safety Related Valves Slide 33
15) Cam-Set (Line Blind System) Application: Absolute positive isolation Process: Industry wide, offshore and maritime Key Features: DN 10-15 (1/2 ) to DN 1200 (48 ) Cam-Set in Hydrotreating unit ASME 150# to 600# standard & up to 1500# No flange or line spreading One man, one side operation Fast Change Material - Carbon steel, stainless steel and all alloys Special designs for Offshore and Maritime Slide 34
Nr Description 1 Body Flange 2 Body Pipe 3 Body Bolts 4 Body Bolt Spacer 5 CAMS 6 Sealing Actuator 7 Actuator Lever 8 Actuator Screw Assembly 9,1 Seal Ring 9,2 Seal Ring 9,3 Seal Ring 10 Seal Carrier 11 Spectacle Plate Assembly 12 Grease Fitting 13 Flange 150 ASME Standard Slide 35
48 inch ASME 150 line blind system Offshore ASME 600# line blind system Slide 36
16) Changeover Valve (Tandem Variant) Application: In order to switch between two SRVs or rupture discs Process: Refinery, chemical & petrochemical processes Key Features: 1 (DN25) to 14 (DN 350) ASME 150# and 300# standard Rising / non rising stem designs Multiple packing configurations Reduced pressure drop Class VI sealing Tandem construction with chain or rod Slide 37
Changeover valve Tandem Changeover valve offshore design 14 inch ASME 300 line tandem changeover valve for FPSO Slide 38
17) Tank Emergency Shut-Off (TESO) Valve Application: Tank Emergency Shut-Off (TESO) valves are typically used on storage vessels containing hazardous gas or fluids Process: Tank farms and storage vessels in refineries, or petrochemical plants Key Features: Several designs for side mounting or tank top installation Intrinsically safe fail safe closure Segmented spindle In-lying spring or weight closure mechanism on air failure Emergency handwheel and numerous control accessories Valve material to suit any media or operating condition Suitable for cryogenic operations Slide 39
Emergency Tank Shut Off (TESO) Valve KOTC TESO valve for LNG in Kuwait Slide 40
Drain and Injection Valves Slide 41
18) Ram Bottom Outlet Valve (Drain Valve) Application: For quick vessel or tank draining or feeding Process: Industry and process wide Key Features: 1 (DN25) to 36 (DN 900) Full nominal bore piston Drainage is absolutely dead space free Metal to metal or radial process sealing options Zero leakage to atmosphere Self cleaning piston and integral flushing Fire safe according to BS 6755 Pt. 2 Slide 42
Ram drain valve Model 28KR Ram drain valve Model 26KR Slide 43
19) Disc Bottom Outlet Valve (Drain Valve) Application: For vessel or tank draining or feeding Process: Industry and process wide Key Features: 1 (DN25) to 18 (DN 450) Disc lowering or rising variants Outlet angle 45, 60 or 90 Dead space free design Flushing connection for in service cleaning Automatic crust breaking with disc rising model Can be combined with sampling valves Fire safe according to BS 6755 Pt. 2 Slide 44
Disc rising drain valve with metal bellows Disc lowering drain valve Model 24BS Slide 45
20) Injection Valves Injection Valve - Model 27SE Inject additives into vessels, tanks or pipelines The valve flanges directly on to the vessel in order to avoid vessel inlet clogging Optimised size, angles and distribution of the holes in the steam injection head Linear control and positioner Leak path to prevent product back flow The valve is self cleaning Available as ½ inch to 6 inches as standard Slide 46
Sampling and Rinsing Valves Slide 47
21) Sampling Systems Application: Process: To enable trouble free sample extraction from reactors, tanks and pipelines Chemical, pharmaceutical & petrochemical Key Features: Up to 10 (DN 250) and ASME 2500# Suitable for vessel, reactor or pipeline installation Robust construction for longer valve life Dead space free, non clogging design Leakage class V or VI shut-off Standard designs from stock, customised on demand Fire safe designs according to BS 6755 Pt. 2 Slide 48
Sampling Valves Sampling valves are used in many chemical processes to test contents of pipelines, discharge and storage vessels during processing without loss of valuable or contaminated contents Screw in - 32PT Wafer 31PF Line Sampling - Models 30CH Slide 49
22) Spray Rinse Valve Application: Process: Eliminates the need to open or close the vessel for cleaning Plastics & polymers and chemical industries Key Features: Directs, controls and uses cleaning agents, and anti fouling media efficiently Customised spray pattern, pressure and volume Positive metal to metal and radial shut-off Rotating spray head option Exchangeable seat and spray head Non clogging design Slide 50
Slide 51
General Information Slide 52
Materials Carbon Steels, high Cr 347H (1.4550) Stainless Steel 317 / 317L (not used much any more) 316 Urea grade, 904L etc. Duplex & Super Duplex e.g. 1.4462/3, CD4MCu Hastelloy B2, B3 or C276 Titanium Grade 2, 3, 5, 7, 11 & 12 Tungsten Carbide Ceramics Inconel, Monel and many more Cast, forged and welded Slide 53
Surface Treatments Titanium Nitriding (Stainless steel and Ti Grade 2) Canadizing (Ti Grade 5) Colmonoy / Stellite Flame spraying (Chrome, Molybdenum, TC) Tungsten Carbides Solid stellite with/out TC coating Slide 54
Slide 55 Sample Customer List
Thank You! Web: www.schuf.com E-mail: valves@schuf.com Tel.: +49 6198 571110 Slide 56