DATA CENTER SOLUTIONS

Similar documents
SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES AND TANKS EPA TIER COMPLIANT

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

MD300. Industrial Diesel Generator Set. 300 kw Diesel. primary codes and standards. Standby Power Rating 375kVA 300kW 60Hz

MD400. Industrial Diesel Generator Set. 400 kw Diesel. primary codes and standards. Standby Power Rating 500kVA 400kW 60Hz PARALLELING UNIT

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L 750kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

GENERAC GUARDIAN SERIES STANDBY GENERATORS

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

1P 120/240V, 3600 RPM,

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

D I E S E L G E N E R A T O R S E T S

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set QSK23 series engine

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set QSX15 series engine

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Diesel generator set QSK23 series engine

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

Diesel generator set QSX15 series engine

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

Siemens Liquid Cooled Standby Generators

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSB7 series engine

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

DIESEL GENERATOR SETS

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Transcription:

SG250 DATA CENTER SOUTIONS Industrial Gaseous Generator Set For More Information: (866) 787-3271 Sales@PTSdcs.com EPA Certified Stationary Emergency SG250 250k 1 of 5 Standby Power Rating 313kVA 250k 60 z Generator image used for illustration purposes only features benefits Generator Set = PROTOTYPE & TORSIONAY TESTED 4 PROVIDES A PROVEN UNIT = U2200 TESTED 4 ENSURES A QUAITY PRODUCT = RINOCOAT PAINT SYSTEM 4 IMPROVES RESISTANCE TO EEMENTS = IDE RANGE OF ENCOSURES 4 PROVIDES A SINGE SOURCE SOUTION Engine = EPA COMPIANT 4 ENVIRONMENTAY FRIENDY = INDUSTRIA TESTED, GENERAC APPROVED 4 ENSURES INDUSTRIA STANDARDS = POER-MATCED OUTPUT 4 ENGINEERED FOR PERFORMANCE = INDUSTRIA GRADE 4 IMPROVES ONGEVITY AND REIABIITY Alternator = TO-TIRDS PITC 4 EIMINATES ARMFU 3RD ARMONIC = AYER OUND ROTOR & STATOR 4 IMPROVES COOING = CASS MATERIAS 4 EAT TOERANT DESIGN = DIGITA 3-PASE VOTAGE CONTRO 4 FAST AND ACCURATE RESPONSE Controls = ENCAPSUATED BOARD / SEAED ARNESS 4 EASY, AFFORDABE REPACEMENT = 4-20mA VOTAGE-TO-CURRENT SENSORS 4 NOISE RESISTANT 24/7 MONITORING = SURFACE-MOUNT TECNOOGY 4 PROVIDES VIBRATION RESISTANCE = ADVANCED DIAGNOSTICS & COMMUNICATIONS 4 ARDENED REIABIITY primary codes and standards

SG250 250k 2 of 5 SG250 ENGINE SPECIFICATIONS application and engineering data General Cooling System Make Generac Cooling System Type Pressurized, Closed Recovery EPA Emissions Compliance Stationary Emergency ater Pump Flow 54 gal/min EPA Emissions Reference See Emissions Data Sheet Fan Type Pusher Cylinder # 6 Fan Speed (rpm) 1632 Type Inline Fan Diameter mm (in.) 990 (39) Displacement - 13.3 Coolant eater attage 2000 Bore - mm (in.) 136.91 (5.39) Coolant eater Standard Voltage 240VAC Stroke - mm (in.) 150.11 (5.91) Compression Ratio 10.5:1 Fuel System Intake Air Method Turbocharged/Aftercooled Fuel Type Natural Gas Number of Main Bearings 7 Carburetor Down Draft Connecting Rods Carbon Steel Secondary Fuel Regulator Standard Cylinder ead Cast Iron, Overhead Valve Fuel Shut Off Solenoid Standard Cylinder iners et, Replaceable Operating Fuel Pressure 11" - 15" 2 O Ignition Altronic CD1 Pistons eat Resistant Alloy Engine Electrical System Crankshaft Die-Forged Carbon Steel System Voltage 24VDC ifter Type Solid Battery Charging Alternator Std Intake Valve Material Special eat-resistant Steel Battery Size (at 0ºC) 1155 CCA Exhaust Valve Material Iconel Alloy, igh Temp Battery Group 8D ardened Valve Seats igh Temp Alloy Stellite Faced Battery Voltage 12VDC Ground Polarity Negative ubrication System Oil Pump Type Gear Oil Filter Type Full-Flow, Cartridge Crankcase Capacity - (qts) 27 (28.5) ATERNATOR SPECIFICATIONS Standard Model 520 Voltage Regulator Type Full Digital Poles 4 Number of Sensed Phases 3 Field Type Revolving Regulation Accuracy (Steady State) ± 0.25% Insulation Class - Rotor Insulation Class - Stator Engine Governing Total armonic Distortion < 5% Governor Electronic Telephone Interference Factor (TIF) < 50 Frequency Regulation (Steady State) ± 0.25% Standard Excitation Permanent Magnent Bearings Sealed Ball Coupling Gear Drive oad Capacity - Standby 100% Prototype Short Circuit Test Yes CODES AND STANDARDS COMPIANCE (ERE APPICABE) NFPA 99 BS5514 NFPA 110 SAE J1349 ISO 8528-5 DIN6271 ISO 1708A.5 IEEE C62.41 TESTING ISO 3046 NEMA ICS 1 Rating Definitions: Standby Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of every 12 hours.

SG250 operating data (60z) POER RATINGS (k) Natural Gas Three-Phase 120/208VAC @0.8pf 250 k Amps: 867 Three-Phase 120/240VAC @0.8pf 250 k Amps: 752 Three-Phase 277/480VAC @0.8pf 250 k Amps: 376 Three-Phase 346/600VAC @0.8pf 250 k Amps: 301 SG250 250k 3 of 5 STARTING CAPABIITIES (skva) skva vs. Voltage Dip 480VAC 208/240VAC Alternator k 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 250 263 395 527 658 790 922 197 296 395 494 593 692 Upsize 1 300 303 454 605 757 908 1059 227 341 454 568 681 794 FUE Fuel Consumption Rates* Natural Gas Percent oad ft 3 /hr m 3 /hr 25% 1495 42.3 50% 2145 60.7 75% 2751 77.9 100% 3446 97.6 * Refer to "Emissions Data Sheet" for maximum fuel flow for EPA and SCAQMD permitting purposes. COOING Air Flow (inlet air combustion and radiator) ft 3 /min (m 3 /min) 20,260 (574) System Coolant Capacity Gal (iters) 15 (56.8) eat Rejection to Coolant BTU/hr 895,960 Max. Operating Air Temp on Radiator ºF (ºC) 122 (50) Max. Ambient Temperature ºF (ºC) 104 (40) Maximum Radiator Backpressure " 2 O 1.50 COMBUSTION AIR REQUIREMENTS Flow at Rated Power cfm 1060 ENGINE Rated Engine Speed rpm 2300 orsepower at Rated k** hp 385 Piston Speed ft/min 2262 BMEP psi 169 ** Refer to Emissions Data Sheet for maximum bp for EPA and SCAQMD permitting purposes. EXAUST Exhaust Flow (Rated Output) cfm (m 3 /min) 3776 (107) Max. Backpressure (Post Silencer) ing 1.5 Exhaust Temp (Rated Output) ºF (ºC) 1460 (793) Exhaust Outlet Size (Open Set) in 5.0" Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.

SG250 250k 4 of 5 SG250 GENERATOR SET Genset Vibration Isolation Std IBC Seismic Certified/Seismic Rated Vibration Isolators Opt Extended warranty Opt Gen-ink Communications Software Opt Steel Enclosure Opt Aluminum Enclosure Opt Enclosure ighting Kits Opt ENGINE SYSTEM General Oil Drain Extension Std Oil Make-Up System Opt Oil eater Opt Critical Exhaust Silencer Std Stainless steel flexible exhaust connection Std Air cleaner Std Fan guard Std Radiator duct adapter Std Fuel System Fuel lockoff solenoid Std Secondary fuel regulator Std Flexible fuel lines Opt Cooling System 120VAC Coolant eater Opt 208VAC Coolant eater Opt 240VAC Coolant eater Std Other Coolant eater - Closed Coolant Recovery System Std UV/Ozone resistant hoses Std Factory-Installed Radiator Std Radiator Drain Extension Std Engine Electrical System Battery charging alternator Std Battery cables Std Battery tray Std Battery box Opt Battery heater Opt Solenoid activated starter motor Std 10A U float/equalize battery charger Opt Rubber-booted engine electrical connections Std ATERNATOR SYSTEM U2200 GENprotect Std Main ine Circuit Breaker Opt 2nd Circuit Breaker Opt 3rd Circuit Breaker - Alternator Upsizing Opt Anti-Condensation eater Opt Tropical coating Opt Permanent Magnet Generator Std CONTRO SYSTEM standard features and options Control Panel Digital Control Panel - Dual 4x20 Display Std Digital G-100 Control Panel - Touchscreen na Digital G-200 Paralleling Control Panel - Touchscreen na Programmable Crank imiter Std 21-ight Remote Annunciator Opt Remote Relay Panel (8 or 16) Opt 7-Day Programmable Exerciser Std Special Applications Programmable PC Std RS-232 Std RS-485 Std All-Phase Sensing DVR Std Full System Status Std Utility Monitoring (Req. -Transfer Switch) Std 2-ire Start Compatible Std Power Output (k) Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std Coolant evel Std Oil Temperature Opt Fuel Pressure Std Engine Speed Std Battery Voltage Std Frequency Std Date/Time Fault istory (Event og) Std ow-speed Exercise - Isochronous Governor Control Std -40deg C - 70deg C Operation Std aterproof Plug-In Connectors Std Audible Alarms and Shutdowns Std Not in Auto (Flashing ight) Std Auto/Off/Manual Switch Std E-Stop (Red Mushroom-Type) Std Remote E-Stop (Break Glass-Type, Surface Mount) Opt Remote E-Stop (Red Mushroom-Type, Surface Mount) Opt Remote E-Stop (Red Mushroom-Type, Flush Mount) Opt NFPA 110 evel I and II (Programmable) Std Remote Communication - RS232 Std Remote Communication - Modem Opt Remote Communication - Ethernet Opt 10A Run Relay Opt Alarms (Programmable Tolerances, Pre-Alarms and Shutdowns) ow Fuel Opt Oil Pressure (Pre-programmed ow Pressure Shutdown) Std Coolant Temperature (Pre-programmed igh Temp Shutdown) Std Coolant evel (Pre-programmed ow evel Shutdown) Std Oil Temperature Opt Engine Speed (Pre-programmed Overspeed Shutdown) Std Voltage (Pre-programmed Overvoltage Shutdown) Std Battery Voltage Std Other Options

dimensions, weights and sound levels SG250 250k OPEN SET T dba* 145 58 69 7278 90 5 of 5 STANDARD ENCOSURE T dba* 175 58 78 8578 90 EVE 1 ACOUSTIC ENCOSURE T dba* 200 58 77 8770 81 EVE 2 ACOUSTIC ENCOSURE T dba* 181 58 107 9728 72 *All measurements are approximate and for estimation purposes only. Sound levels measured at 23ft (7m) and does not account for ambient site conditions. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIA DEAER DATA CENTER SOUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. S45 29290 Y. 59, aukesha, I 53189 generac.com 2011 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0191260SBY-C / Printed in U.S.A. 10/19/11