T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

Similar documents
ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

HS22 Bulletin # November 1992 Supersedes September 1990

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

T-Class Split System Units R-410A - 50 HZ

VERIFIED ENERGY PERFORMANCE

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

ELITE SERIES R-410A Ready - Multi-Position

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ELITE Series R-410A - Two-Stage Compressor

10AC DIPLOMAT SERIES RFC SYSTEMS

ELITE Series R-410A - Two-Stage Compressor

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

13 HP x

HP25 HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ

XC21. DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

13 GCS X A X Nominal SEER Minor Revision Number

DAVE LENNOX SIGNATURE COLLECTION

ZHA/ZHB SERIES WARNING

ELITE Series R-410A - Upflow / Horizontal

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 59,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

Typical Applications. Horizontal Installation

HP19 Bulletin No August 1994 Supersedes November 1993

VHIA High-Static Ducted Indoor Units - 60HZ

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

T A A 120 S 4 D - 1 M

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ

10ACC MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS 1.5 to 5 Tons SEER up to Cooling Capacity 17,400 to 59,500 Btuh

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Z-Series Rooftop Units 60 HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

Z-Series Rooftop Units 60 HZ

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

CHP

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

Landmark Rooftop Packaged Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

TECHNICAL SPECIFICATIONS

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

TECHNICAL SPECIFICATIONS

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

P7RE Series Single Packaged Air Conditioner

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

TSA6. Product Specifications. SmartComfort TXC 5600

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

P7RE Series Single Packaged Air Conditioner

N4A6. Product Specifications

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL SPECIFICATIONS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

Q7RE Series Single Packaged Heat Pump, Single Phase

PHB SERIES 7-1/2 and 10 TON

13 SEER Light Commercial 3 Phase

TECHNICAL SPECIFICATIONS WSH2BF

WCA4**4. Product Specifications

Transcription:

AIR CONDITIONERS ELS T-SERIES COMMERCIAL SPLIT SYSTEMS R-40A - 60 HZ Bulletin No. ELS-072-240 (2/208) P R O D U C T S P E C I F I C AT I O N S 072-090 Models 80-240 Models EER up to 2.0 6 to 20 Tons Cooling Capacity - 7,000 to 232,000 Btuh 20-50 Models MODEL NUMBER IDENTIFICATION EL S 20 S 4 S T Y Brand/Family EL = E-Series Product Line Unit Type S = Split System Air Conditioner Nominal Cooling Capacity Tons 072 = 6 Tons 090 = 7.5 Tons 20 = 0 Tons 50 = 2.5 Tons 80 = 5 Tons 240 = 20 Tons Cooling Efficiency S = Standard Efficiency Voltage Y = 208/230V-3 phase-60hz G = 460V-3 phase-60hz J = 575V-3 phase-60hz Minor Design Sequence = st Revision 2 = 2nd Revision 3 = 3rd Revision Part Load Capability S = Single StageCompressor T = Dual Stage Compressor Refrigerant Circuits S = Single Circuit D = Dual Circuits Refrigerant Type 4 = R 40A

FEATURES AND BENEFITS D B I F J 072-090 Models G C 80-240 Models K H E 20-50 Models CONTENTS AHRI System Matches... 9 Dimensions... Features And Benefits... 2 Model Number Identification... Options / Accessories... 8 Ratings... 4 Sound Data... 9 Specifications... 6 Unit Clearances... 0 Weight Data... 7 EQUIPMENT WARRANTY Compressor - Limited warranty for five years in nonresidential applications. All other covered components - One year in nonresidential applications. Refer to Allied Equipment Limited Warranty certificate for specific details. ELS 6 to 20 Ton Air Conditioners / Page 2 APPLICATIONS Air conditioners are available in 6, 7.5, 0 ton (one compressor) and 0, 2.5, 5 and 20 ton (two compressors) nominal sizes. Matching air handlers provide a wide range of cooling capacities and applications. See AHRI Ratings tables. See Air Handlers sections for air handler data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation. Installer must set air conditioner, connect refrigerant lines, add refrigerant charge and make electrical connections to complete job. APPROVALS All units tested in an ETL certified environmental testing facility. AHRI Certified to AHRI Standard 340/360-205. Sound tested in accordance with test conditions included in AHRI Standard 270 or 370. Units and components within are bonded for grounding to meet safety standards for servicing required by UL, ULC, NEC and CEC. All units are ETL listed. All units meet two-stage cooling requirements of ASHRAE 90., IECC 205, and California Code of Regulations, Title 24. ISO 900 Registered Manufacturing Quality System. REFRIGERATION SYSTEM

B C D E F FEATURES AND BENEFITS Refrigerant Units operate with chlorine-free,ozone friendly, R-40A (field furnished). Outdoor Coil Fan(s) ELS072 and ELS090 units have one outdoor fan. ELS20 and ELS50 units have two outdoor fans. ELS80 and ELS240 units have four outdoor fans. Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity. Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs, and walkways. Fan motors are totally enclosed, overload protected and equipped with a rain shield. Fan service access is accomplished by removal of fan guard(s) or removal of access panel. Copper Tube/Enhanced Fin Coil(s) Units are equipped with a wrap-around U shaped coil (072-090-20 models) or two L shaped coils (50-80- 240 models). Coils are constructed of precisely spaced ripple-edge aluminum fins machine fitted to seamless copper tubes. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fins equipped with collars that grip tubing for maximum contact area. Flared shoulder tubing connections and machine brazed silver soldering provide tight, leakproof joints. Long life copper tubing is corrosion-resistant and easy to field service. Thoroughly factory tested under high pressure to ensure leakproof construction. Completely accessible for cleaning. High Pressure Switch Shuts off unit if abnormal operating conditions cause discharge pressure to rise above setting. Protects the compressor from excessive condensing pressure. Manual reset. Loss of Charge Switch Shuts off unit if liquid line pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. Hi-Capacity Drier(s) Drier traps moisture or dirt that could contaminate the refrigerant system. G H Refrigerant Lines and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawings. Fully serviceable suction and liquid line service valves provide complete service access to refrigerant system. Suction valve can be fully shut off, while liquid valve can be front seated to manage refrigerant charge while servicing system. Accessible outside of unit cabinet. COMPRESSORS ELS072, ELS090 and ELS20S4S models feature one dual-stage scroll compressor. ELS20S4D, ELS50S4D, ELS80S4D and ELS240S4D models have two single-stage scroll compressors. Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. ELS 6 to 20 Ton Air Conditioners / Page 3

FEATURES AND BENEFITS I J K COMPRESSORS (continued) ELS072, ELS090 and ELS20S4S Dual-Stage Models A 24-volt DC solenoid valve inside the compressor controls staging. When the 3-way solenoid is energized it moves the lift ring assembly to block the ports and the compressor operates at full-load or 00% capacity. When the solenoid is deenergized the lift ring assembly moves to unblock the compressor ports and the compressor operates at part-load or approximately 67% of its full-load capacity. The loading and unloading of the two stage scroll is done on the fly without shutting off the single-speed compressor motor between stages. Crankcase Heater(s) (All Models) Crankcase heater(s) prevents migration of liquid refrigerant into compressor(s) and ensures proper compressor lubrication. CABINET Heavy-gauge, pre-painted steel cabinet provides superior rust and corrosion protection. Removable panels allow access for unit servicing. Heavy duty steel base channels raise the unit off of mounting surface away from damaging moisture. Unit lifting holes and forklift slots furnished in base rails. See dimension drawings. Control Box Control box located in separate compartment in unit cabinet. All controls are pre-wired at the factory. Control box is large enough for field installed DDC or other field supplied control modules. Options/Accessories CONTROLS Options/Accessories Field Installed Low Ambient Control Air conditioning units operate satisfactorily down to 45ºF outdoor air temperature without any additional controls. Low Ambient Control Kit can be field installed, allowing unit operation down to 0ºF using pressure-regulated fan speed control. Indoor Air Quality (CO 2 ) Sensors Monitors CO 2 levels, reports which adjusts economizer dampers as needed. Thermostat Thermostat is not furnished with unit and must be ordered extra. Aftermarket Unit Controller Options See Options/Accessories table for selection. ELECTRICAL Field Installed GFI Service Outlets (2) 5V ground fault circuit interrupter (GFCI) type, nonpowered, field wired. Factory Installed Corrosion Protection Polymeric epoxy coating that is deposited by electrical transport (electrophoresis), using a process known as electrocoat (e-coat). Available for enhanced coil corrosion protection. Factory installed on the condenser coil. Painted base pan is provided with this option. Field Installed Combination Coil/Hail Guards Heavy gauge steel frame with expanded metal mesh to protect the outdoor coil from damage. ELS 6 to 20 Ton Air Conditioners / Page 4

THIS PAGE INTENTIONALLY LEFT BLANK ELS 6 to 20 Ton Air Conditioners / Page 5

SPECIFICATIONS - 6-7.5 TON General Model No. ELS072S4S ELS090S4S Data Nominal Size - Tons 6 7.5 Connections Liquid line - in. (o.d) () 3/8 () 5/8 (sweat) Suction line - in. (o.d) () -/8 () -/8 Refrigerant Factory Charge R-40A holding charge (2 lbs. per stage) (R-40A) Field charge (25 ft. line set) 8 lbs. 0 oz. (includes holding charge) 20 lbs. 0 oz. (includes holding charge) Compressor () Dual-Stage Scroll () Dual-Sstage Scroll Condenser Net face area - sq. ft. Outer coil 29.3 29.3 Coil Inner coil 4.2 28.4 Tube diameter - in. & no. of rows 3/8 -.5 3/8-2 Fins per inch 20 20 Condenser Diameter - in. & no. of blades () 24-3 () 24-4 Fan(s) Motor hp () /3 () /2 air volume - cfm 4700 5600 Rpm 075 075 Watts 400 580 ELECTRICAL DATA Line voltage data - 60 hz - 3 phase 208/230V 460V 575V 208/230V 460V 575V 2 Maximum Overcurrent Protection (amps) 40 5 5 60 25 20 3 Minimum circuit ampacity 24 2 9 37 7 3 Compressor No. of Compressors Rated load amps 7.6 8.5 6.3 26.9 2 9 Locked rotor amps 36 66 55 65 94 65 Condenser Fan Motor ( phase) NOTE - Extremes of operating range are plus and minus 0% of line voltage. Field provided charge with 25 ft. line set. 2 HACR type circuit breaker or fuse. No. of motors Full load amps.7 0.8 3.5.2 Locked rotor amps 4.3 2.4.9 6 3 2.9 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. SPECIFICATIONS - 0 TON General Model No. ELS20S4S ELS20S4D Data Nominal Size - Tons 0 0 Connections Liquid line - in. (o.d) () 5/8 (2) 3/8 (sweat) Suction line - in. (o.d) () -3/8 (2) -/8 Refrigerant Factory Charge R-40A holding charge (2 lbs. per stage) (R-40A) Field charge Circuit 32 lbs. 0 oz. (includes holding charge) 2 lbs. 0 oz. (includes holding charge) (25 ft. line set) Circuit 2 - - - 2 lbs. 0 oz. (includes holding charge) Compressor () Dual-Stage Scroll (2) Single-Sstage Scroll Condenser Net face area - sq. ft. Outer coil 29.3 29.3 Coil Inner coil 28.4 28.4 Tube diameter - in. & no. of rows 3/8-2 3/8-2 Fins per inch 20 20 Condenser Diameter - in. & no. of blades (2) 24-3 (2) 24-3 Fan(s) Motor hp (2) /3 (2) /3 air volume - cfm 8300 8300 Rpm 075 075 Watts 830 830 ELECTRICAL DATA Line voltage data - 60 hz - 3 phase 208/230V 460V 575V 208/230V 460V 575V 2 Maximum Overcurrent Protection (amps) 80 30 25 40 20 5 3 Minimum circuit ampacity 47 2 6 30 6 3 Compressor No. of Compressors 2 2 2 Rated load amps (total) 34.6 4.8. 2 (24) 6.3 (2.6) 4.9 (9.8) Locked rotor amps (total) 240 30 94 90 (80) 60 (20) 4 (82) Condenser Fan Motor ( phase) No. of motors 2 2 2 2 2 2 Full load amps (total).7 (3.4) 0.8 (.6) (2).7 (3.4) 0.8 (.6) (2) Locked rotor amps (total) 4.3 (8.6) 2.4 (4.8).9 (3.8) 4.3 (8.6) 2.4 (4.8).9 (3.8) NOTE - Extremes of operating range are plus and minus 0% of line voltage. Field provided charge with 25 ft. line set. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. ELS 6 to 20 Ton Air Conditioners / Page 6

SPECIFICATIONS - 2.5-20 TON General Model No. ELS50S4D ELS80S4D ELS240S4D Data Nominal Size - Tons 2.5 5 20 Connections (sweat) Refrigerant (R-40A) Field charge (25 ft. line set) Liquid line - in. (o.d) (2) 5/8 (2) 5/8 (2) 5/8 Suction line - in. (o.d) (2) -/8 (2) -/8 (2) -3/8 Factory Charge Circuit Circuit 2 5 lbs. 0 oz. (includes holding charge) 5 lbs. 0 oz. (includes holding charge) R-40A holding charge (2 lbs. per stage) 24 lbs. 0 oz. (includes holding charge) 24 lbs. 0 oz. (includes holding charge) 22 lbs. 4 oz. (includes holding charge) 23 lbs. 3 oz. (includes holding charge) Compressor (2) Single-Stage Scroll (2) Single-Stage Scroll (2) Single-Stage Scroll Condenser Coil Condenser Fan(s) ELECTRICAL DATA Net face area - sq. ft. Outer coil 34.2 58.7 58.7 Inner coil 33.3 57.7 57.7 Tube diameter - in. & no. of rows 3/8-2 3/8-2 3/8-2 Fins per inch 20 20 20 Diameter - in. & no. of blades (2) 24-4 (4) 24-3 (4) 24-3 Motor hp (2) /2 (4) /3 (4) /3 air volume - cfm 0,300 6,600 6,600 Rpm 075 075 075 Watts 30 660 660 Line voltage data - 60 hz - 3 phase 208/230V 460V 575V 208/230V 460V 575V 208/230V 460V 575V 2 Maximum Overcurrent Protection (amps) 60 25 25 80 40 30 90 50 40 3 Minimum circuit ampacity 50 2 20 63 3 25 70 36 30 Compressor No. of Compressors 2 2 2 2 2 2 2 2 2 Condenser Fan Motor ( phase) Rated load amps (total) Locked rotor amps (total) 9.6 (39.2) 36 (272) 8.2 (6.4) 66 (32) 6.6 (3.2) 55 (0) 25 (50) 64 (328) 2.2 (24.4) 00 (200) 9 (8) 78 (56) 28.2 (56.4) 240 (480) 4.7 (29.4) 30 (260).3 (22.6) 93.7 (87.4) No. of motors 2 2 2 4 4 4 4 4 4 Full load amps (total) Locked rotor amps (total) 3 (6) 6 (2) NOTE - Extremes of operating range are plus and minus 0% of line voltage. Field provided charge with 25 ft. line set. 2 HACR type circuit breaker or fuse..5 (3) 3 (6).2 (2.4) 2.9 (5.8).7 (6.8) 4.3 (7.2) 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 0.8 (3.2) 2.4 (9.6) (4).9 (7.6).7 (6.8) 4.3 (7.2) 0.8 (3.2) 2.4 (9.6) (4).9 (7.6) WEIGHT DATA Model No. Net Shipping lbs. kg lbs. kg 072S4S 38 44 338 53 090S4S 345 57 365 66 20S4S 452 205 477 26 20S4D 480 28 505 229 50S4D 535 243 560 254 80S4D 775 352 800 363 240S4D 832 377 857 389 OPTIONS / ACCESSORIES COMBINED COIL/HAIL GUARDS T2GARD20L- 40 8 45 20 T2GARD20M- 45 20 50 23 T2GARD2M- 45 20 50 23 T2GARD20N-- 90 4 00 45 ELS 6 to 20 Ton Air Conditioners / Page 7

OPTIONS / ACCESSORIES Item Catalog No. ELS 072 S4S ELS 090 S4S ELS 20 S4S ELS 20 S4D ELS 50 S4D ELS 80 S4D ELS 240 S4D CABINET Combined Coil/Hail Guards T2GARD5L- 3T29 X X T2GARD5M 3T30 X X T2GARD5M2 3T32 X T2GARD5N- 3T37 X X Corrosion Protection Factory O O O O O O O CONTROLS BACnet Module A0CTRL3LS 7A08 X X X X X X X BACnet Sensor with Display K0SNSR0FF 97W23 X X X X X X X BACnet Sensor without Display K0SNSR00FF 97W24 X X X X X X X Low Ambient Control (0ºF) A2CWKT0LM- 6F8 X X A2CWKT04M-- 6F26 X A2CWKT02M-- 6F24 X X A2CWKT03N-- 6F25 X X ELECTRICAL GFI Service Outlets 5 amp non-powered, field-wired (208/230V, 460V only) LTAGFIK0/5/5 74M70 X X X X X X X 20 amp non-powered, field-wired (575V only) CGFCI20FF 67E0 X X X X X X X INDOOR AIR QUALITY Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N39 X X X X X X X Sensor - Wall-mount, off-white plastic cover, no display C0SNSR52AEL 87N53 X X X X X X X Sensor - Black plastic case with LCD display, rated for plenum mounting Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting C0SNSR5AEL 87N52 X X X X X X X C0SNSR53AEL 87N54 X X X X X X X CO 2 Sensor Duct Mounting Kit C0MISC9AE- 85L43 X X X X X X X Aspiration Box - for duct mounting non-plenum rated CO 2 sensor (77N39) C0MISC6AE- 90N43 X X X X X X X NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. O - Factory Installed with extended lead time. X - Field Installed ELS 6 to 20 Ton Air Conditioners / Page 8

AHRI SYSTEM MATCHES Model Cooling Btuh EER IEER Air Handler Expansion Device AHRI Reference ELS072S4S 7,000 2.0 6.0 ELA072S4S Factory TXV 20753420 ELS090S4S 89,000.2 4.4 ELA090S4D Factory TXV 2075342 ELS20S4S 5,000.2 4.4 ELA20S4D Factory TXV 20753423 ELS20S4D 5,000.2 2.9 ELA20S4D Factory TXV 20753422 ELS50S4D 36,000.0 2.4 ELA50S4D Factory TXV 20753424 ELS80S4D 78,000.0 2.4 ELA80S4D Factory TXV 20753975 ELS240S4D 232,000.0 2.4 ELA240S4D Factory TXV 20753426 NOTES - Units with capacity of 65,000 Btuh or greater are AHRI Certified to AHRI Standard 340/360: 95 F outdoor air temperature, 80 F db/67 F wb entering evaporator air (minimum external duct static pressure) with 25 ft. of connecting refrigerant lines. SOUND DATA Unit Model No. Octave Band Linear Sound Power Levels db, re 0-2 Watts Center Frequency - HZ 25 250 500 000 2000 4000 8000 Sound Rating Number (db) ELS072S4S 65 68 73 76 72 68 63 8 ELS090S4S 64 69 73 77 74 70 63 8 ELS20S4S 70 77 82 8 77 75 7 86 ELS20S4D 7 77 80 80 77 72 67 85 ELS50S4D 68 77 80 82 78 73 65 86 ELS80S4D 73 80 83 83 79 74 66 88 ELS240S4D 73 80 85 84 80 78 74 89 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270 test conditions. ELS 6 to 20 Ton Air Conditioners / Page 9

UNIT CLEARANCES - INCHES (MM) ELS072 and ELS090 30 (762) CONTROL BOX ACCESS See NOTES 36 (94) NOTES: Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). A clearance of 24 in. (60 mm) must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. See NOTES ELS20 and ELS50 See NOTES NOTES: Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). A clearance of 24 in. (60 mm) must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. See NOTES 30 (762) 36 (94) CONTROL BOX ACCESS ELS80 and ELS240 30 (762) CONTROL BOX ACCESS See NOTES 36 (94) NOTES: Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). A clearance of 24 in. (60 mm) must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. See NOTES ELS 6 to 20 Ton Air Conditioners / Page 0

DIMENSIONS - INCHES (MM) - ELS072 AND ELS090 CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm ELS072S4S 66 30 73 33 97 44 82 37 23-/4 59 9-/4 489 ELS090S4S 75 34 89 40 2 5 88 40 25 635 20-/4 54 9-/8 (232) AA INLET AIR BB OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) -/8 (29) LIQUID LINE CENTER OF GRAVITY 5 (27) 2-/8 (54) -/8 (29) OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) REFRIGERANT LINE CONNECTIONS DETAIL DISCHARGE AIR 37-5/8 (956) SUCTION LINE FF OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) DD ELECTRICAL INLETS (Above Refrigerant Lines) EE DISCHARGE AIR TOP VIEW OUTDOOR FAN GUARD INLET AIR 46-/8 (72) INLET AIR CC OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) -/4 (286) 2 (5) COMPRESSOR CONTROL BOX ACCESS COMPRESSOR 45-/4 (49) REFRIGERANT LINE CONNECTIONS SEE DETAIL 48-3/4 (238) ELECTRICAL INLETS (Above Refrigerant Lines) LIFTING HOLES (For Rigging) 39-7/8 (03) BASE FRONT VIEW FORKLIFT SLOTS (Both Sides) 48-3/8 (229) SIDE VIEW BASE 3-/2 (89) OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) ELS 6 to 20 Ton Air Conditioners / Page

DIMENSIONS - INCHES (MM) - ELS20 AND ELS50 CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm ELS20S4S 30 59 24 56 07 49 50 20-/2 52 33-/2 85 ELS20S4D 22 55 9 54 27 58 3 59 2 533 28-/2 724 ELS50S4D 44 66 32 60 33 60 45 66 9 483 30 762 OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) 5 (27) 3-3/4 (95) -/8 (29) -/8 (29) 9-/8 (232) 6-/2 (65) LIQUID LINES SUCTION LINES AA OUTDOOR FAN GUARDS (2) CENTER OF GRAVITY FF EE INLET AIR BB INLET AIR 2-/8 (54) SINGLE STAGE ELS20S4S OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) STAGE ELS20S4D ELS50S4D REFRIGERANT LINE CONNECTIONS DETAIL 57-7/8 (470) DISCHARGE AIR STAGE 2 ELS20S4D ELS50S4D OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) DD ELECTRICAL INLETS (Above Refrigerant Lines) DISCHARGE AIR TOP VIEW 4-3/8 (05) INLET AIR CC OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) -/4 (286) 2(5) COMPRESSOR CONTROL BOX ACCESS 48-3/4 (238) REFRIGERANT LINE CONNECTIONS SEE DETAIL 45-/4 (49) FORKLIFT SLOTS (Both Sides) 60-/8 (527) FRONT VIEW BASE ELECTRICAL INLETS (Above Refrigerant Lines) LIFTING HOLES (For Rigging) 43-5/8 BASE (08) SIDE VIEW 3-/2 (89) OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) ELS 6 to 20 Ton Air Conditioners / Page 2

DIMENSIONS - INCHES (MM) - ELS80 AND ELS240 CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm ELS80S4D 8 82 77 8 25 98 22 00 29 737 38 965 ELS240S4D 92 87 89 86 232 05 238 08 29 737 37-/2 953 9-/8 (232) 6-/2 (65) LIQUID LINE (2) SUCTION LINE (2) AA OUTDOOR FAN GUARDS (4) INLET AIR OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) BB 5 (27) 3-3/4 (95) -/8 (29) 2-/8 (54) -/8 (29) STAGE STAGE 2 REFRIGERANT LINE CONNECTIONS DETAIL OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) 57-7/8 (470) DISCHARGE AIR EE OPTIONAL HAIL GUARD (Field Installed All Coil Sides) (Not used with Coil Guard) CENTER OF GRAVITY FF DD ELECTRICAL INLETS (Above Refrigerant Lines) INLET AIR TOP VIEW 86-/2 (297) DISCHARGE AIR CC INLET AIR OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) 2(5) -/4 (286) COMPRESSOR CONTROL BOX ACCESS REFRIGERANT LINE CONNECTIONS SEE DETAIL 45-/4 (49) 48-3/4 (238) LIFTING HOLES (For Rigging) 60-/8 BASE (527) FRONT VIEW ELECTRICAL INLETS (Above Refrigerant Lines) FORKLIFT SLOTS (Both Sides) 88-3/4 (2254) SIDE VIEW BASE 3-/2 (89) OPTIONAL COIL GUARD (Field Installed All Coil Sides) (Not used with Hail Guard) ELS 6 to 20 Ton Air Conditioners / Page 3

RATINGS NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. ELS072S4S + ELA072S4S - PART LOAD Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 280 53.5 2.26 0.7 0.82 0.94 5.2 2.57 0.7 0.84 0.96 48.7 2.94 0.73 0.86 0.98 45.8 3.35 0.74 0.88 63 F 600 57. 2.26 0.74 0.87 0.99 54.6 2.57 0.75 0.89 5.6 2.93 0.77 0.92 48.5 3.35 0.79 0.95 920 59.6 2.25 0.78 0.93 56.9 2.57 0.79 0.95 53.9 2.93 0.8 0.98 50.8 3.35 0.84 280 57.2 2.25 0.56 0.67 0.78 54.9 2.57 0.57 0.68 0.8 52.3 2.93 0.57 0.7 0.82 49.3 3.34 0.58 0.7 0.84 67 F 600 6. 2.25 0.58 0.7 0.84 58.4 2.57 0.59 0.72 0.85 55.5 2.93 0.6 0.74 0.88 52.2 3.35 0.6 0.76 0.9 920 63.9 2.25 0.6 0.75 0.89 6 2.56 0.6 0.76 0.9 57.9 2.93 0.63 0.78 0.94 54.5 3.34 0.64 0.8 0.97 280 60.8 2.25 0.44 0.54 0.64 58.5 2.57 0.44 0.55 0.66 55.7 2.93 0.44 0.56 0.67 52.7 3.35 0.44 0.57 0.68 7 F 600 65 2.25 0.44 0.57 0.68 62.2 2.56 0.45 0.57 0.7 59.2 2.93 0.45 0.58 0.7 55.9 3.34 0.45 0.59 0.73 920 68. 2.24 0.45 0.59 0.72 65. 2.56 0.46 0.6 0.74 6.9 2.92 0.46 0.6 0.75 58.3 3.34 0.47 0.63 0.78 ELS072S4S + ELA072S4S - FULL LOAD Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 920 68.4 4.2 0.73 0.86 0.98 65.3 4.76 0.74 0.88 62 5.39 0.76 0.9 58.4 6.4 0.78 0.93 63 F 2400 7.7 4.24 0.77 0.93 68.3 4.79 0.79 0.95 64.9 5.43 0.8 0.97 6.3 6.7 0.83 0.99 2880 74.3 4.27 0.82 0.98 70.9 4.82 0.84 67.4 5.45 0.86 64. 6.9 0.89 920 72.5 4.25 0.58 0.7 0.83 69.2 4.8 0.59 0.72 0.84 65.9 5.44 0.59 0.73 0.87 62.2 6.7 0.6 0.75 0.89 67 F 2400 75.9 4.29 0.6 0.75 0.89 72.5 4.84 0.62 0.77 0.9 69 5.48 0.63 0.79 0.94 65 6.2 0.64 0.8 0.97 2880 78.7 4.33 0.63 0.8 0.95 75. 4.87 0.65 0.82 0.97 7. 5.5 0.66 0.84 0.99 67 6.23 0.68 0.87 920 76.4 4.3 0.44 0.56 0.68 73.3 4.85 0.44 0.57 0.69 69.8 5.48 0.45 0.58 0.7 65.9 6.22 0.45 0.59 0.73 7 F 2400 80.3 4.35 0.45 0.59 0.73 76.6 4.89 0.46 0.6 0.74 72.9 5.52 0.46 0.6 0.76 69 6.25 0.47 0.63 0.78 2880 83.2 4.38 0.47 0.62 0.77 79.4 4.93 0.47 0.63 0.79 75.5 5.56 0.48 0.65 0.82 7. 6.28 0.48 0.67 0.84 ELS090S4S + ELA090S4D - PART LOAD Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 600 65 2.76 0.7 0.84 0.96 62. 3.23 0.73 0.86 0.98 58.9 3.75 0.74 0.88 55.5 4.33 0.76 0.9 63 F 2000 68.9 2.76 0.76 0.9 65.7 3.23 0.77 0.92 62.2 3.75 0.79 0.95 58.6 4.33 0.82 0.98 2400 72 2.75 0.8 0.96 68.5 3.22 0.82 0.98 65 3.74 0.85 6.8 4.32 0.88 600 69.7 2.76 0.57 0.68 0.8 66.7 3.23 0.57 0.7 0.82 63.4 3.75 0.58 0.7 0.84 59.8 4.33 0.59 0.73 0.87 67 F 2000 73.8 2.75 0.59 0.73 0.86 70.6 3.22 0.6 0.74 0.89 66.8 3.74 0.6 0.76 0.9 63 4.32 0.63 0.79 0.94 2400 76.9 2.75 0.62 0.77 0.92 73.2 3.22 0.63 0.8 0.95 69.4 3.74 0.64 0.82 0.98 65.3 4.32 0.66 0.85 600 74.6 2.75 0.44 0.55 0.66 7.4 3.22 0.44 0.56 0.67 67.9 3.74 0.44 0.56 0.68 64. 4.32 0.44 0.57 0.7 7 F 2000 78.9 2.74 0.44 0.57 0.7 75.5 3.2 0.45 0.58 0.72 7.6 3.74 0.45 0.6 0.73 67.6 4.32 0.46 0.6 0.76 2400 82. 2.74 0.46 0.6 0.75 78.3 3.2 0.46 0.6 0.77 74.4 3.74 0.47 0.63 0.79 70.2 4.32 0.48 0.65 0.82 ELS090S4S + ELA090S4D - FULL LOAD Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 2400 89. 5.87 0.73 0.87 0.99 85.2 6.49 0.75 0.88 80.8 7.8 0.76 0.9 76.3 7.93 0.78 0.93 63 F 3000 93.9 5.98 0.78 0.93 89.5 6.59 0.8 0.95 84.9 7.28 0.82 0.98 80 8.04 0.84 3600 97.3 6.06 0.83 0.99 93. 6.69 0.85 88.9 7.38 0.87 84. 8.5 0.9 2400 95.2 6.0 0.58 0.7 0.83 90.9 6.63 0.59 0.72 0.85 86.3 7.32 0.6 0.74 0.87 8. 8.08 0.6 0.75 0.9 67 F 3000 99.5 6. 0.6 0.76 0.9 95. 6.73 0.62 0.77 0.92 89.9 7.4 0.63 0.79 0.95 84.7 8.7 0.65 0.82 0.98 3600 03. 6.9 0.64 0.8 0.96 98.2 6.8 0.65 0.82 0.98 93. 7.49 0.67 0.85 87.8 8.25 0.68 0.88 2400 0. 6.5 0.44 0.56 0.68 96.6 6.77 0.44 0.57 0.69 9.6 7.45 0.45 0.58 0.7 86.4 8.2 0.45 0.59 0.73 7 F 3000 05.9 6.26 0.45 0.59 0.73 00.9 6.87 0.46 0.6 0.75 95.7 7.56 0.46 0.62 0.77 90. 8.3 0.47 0.63 0.79 3600 09.2 6.34 0.47 0.63 0.78 03.8 6.95 0.48 0.64 0.8 98.5 7.64 0.48 0.66 0.82 92.7 8.39 0.49 0.67 0.85 ELS 6 to 20 Ton Air Conditioners / Page 4

RATINGS NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. ELS20S4S + ELA20S4D - PART LOAD Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 2240 88.8 3.53 0.72 0.84 0.97 84.9 4.6 0.73 0.86 0.99 80. 4.87 0.75 0.89 74.3 5.67 0.78 0.93 63 F 2800 93.5 3.49 0.77 0.9 89.7 4.2 0.78 0.93 84.5 4.83 0.8 0.96 78.5 5.63 0.83 0.99 3360 97 3.48 0.8 0.98 93.2 4. 0.83 0.99 88.6 4.79 0.85 83.3 5.58 0.88 2240 94.5 3.49 0.57 0.69 0.8 90.5 4. 0.58 0.7 0.83 85.7 4.8 0.59 0.72 0.85 80 5.6 0.6 0.75 0.88 67 F 2800 99. 3.46 0.6 0.74 0.88 95.5 4.08 0.6 0.76 0.9 90.5 4.79 0.6 0.78 0.92 84 5.58 0.64 0.8 0.96 3360 02.5 3.44 0.63 0.79 0.95 99. 4.06 0.64 0.8 0.96 93.7 4.76 0.65 0.82 0.99 87.2 5.54 0.67 0.85 2240 00.2 3.46 0.44 0.56 0.67 96.4 4.07 0.43 0.55 0.67 9.9 4.77 0.44 0.58 0.69 85.7 5.56 0.45 0.58 0.7 7 F 2800 04.8 3.43 0.45 0.59 0.7 0.2 4.04 0.45 0.59 0.73 96. 4.74 0.46 0.6 0.75 90 5.53 0.46 0.62 0.77 3360 07.9 3.42 0.46 0.62 0.77 04.6 4.02 0.46 0.63 0.78 99.4 4.72 0.47 0.64 0.8 93.2 5.5 0.48 0.66 0.83 ELS20S4S + ELA20S4D - FULL LOAD Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 3200 2.6 7.39 0.73 0.87 0.99 07. 8.9 0.74 0.88 0.5 9.5 0.76 0.9 94.6 0.2 0.78 0.94 63 F 4000 8. 7.46 0.78 0.93 2.4 8.27 0.8 0.96 06. 9.22 0.82 0.98 99.6 0.3 0.85 4800 22.5 7.53 0.83 0.99 6.9 8.35 0.85. 9.3 0.88 04.6 0.4 0.9 3200 9.5 7.48 0.58 0.7 0.83 4.2 8.3 0.59 0.72 0.85 07.9 9.25 0.59 0.73 0.87 00.9 0.34 0.6 0.76 0.9 67 F 4000 25.5 7.57 0.6 0.76 0.9 9.4 8.39 0.62 0.77 0.92 2.8 9.33 0.63 0.79 0.95 05.2 0.39 0.65 0.82 0.98 4800 29.6 7.64 0.64 0.8 0.96 23.2 8.46 0.65 0.83 0.98 6.3 9.39 0.67 0.85 08.8 0.46 0.68 0.88 3200 27 7.59 0.44 0.56 0.68 2.3 8.42 0.45 0.57 0.69 4.9 9.37 0.45 0.58 0.7 07.7 0.43 0.45 0.6 0.74 7 F 4000 33 7.69 0.45 0.59 0.73 26.9 8.52 0.46 0.6 0.75 9.8 9.45 0.46 0.62 0.77 2 0.52 0.47 0.64 0.8 4800 37. 7.75 0.47 0.63 0.79 30.8 8.57 0.47 0.64 0.8 23.6 9.5 0.48 0.66 0.83 5.3 0.58 0.49 0.68 0.86 ELS 6 to 20 Ton Air Conditioners / Page 5

RATINGS NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. ELS20S4D + ELA20S4D - PART LOAD ( Compressor Operating) Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 2240 53.4 2.79 0.64 0.75 0.87 5. 3.4 0.64 0.76 0.89 48.7 3.54 0.65 0.78 0.92 46. 3.99 0.67 0.8 0.95 63 F 2800 57 2.8 0.67 0.8 0.94 54.5 3.6 0.68 0.82 0.97 5.9 3.55 0.69 0.85 0.99 49. 4 0.7 0.88 3360 59.9 2.82 0.7 0.86 57. 3.8 0.72 0.88 54.2 3.57 0.74 0.9 5.3 4.02 0.76 0.94 2240 57.3 2.8 0.5 0.6 0.7 54.8 3.6 0.52 0.62 0.72 52.4 3.56 0.52 0.63 0.74 49.7 4 0.53 0.64 0.76 67 F 2800 6.3 2.83 0.53 0.64 0.76 58.5 3.9 0.54 0.65 0.78 55.7 3.58 0.54 0.66 0.8 52.9 4.03 0.55 0.68 0.83 3360 64.2 2.85 0.55 0.67 0.82 6.3 3.2 0.56 0.69 0.84 58.3 3.6 0.56 0.7 0.87 55. 4.05 0.58 0.73 0.9 2240 6.2 2.83 0.4 0.49 0.58 58.7 3.9 0.4 0.5 0.59 56 3.59 0.4 0.5 0.6 53.3 4.03 0.4 0.5 0.6 7 F 2800 65.5 2.86 0.4 0.5 0.6 62.5 3.22 0.4 0.52 0.62 59.7 3.62 0.4 0.53 0.64 56.6 4.06 0.42 0.53 0.65 3360 68.5 2.88 0.42 0.53 0.64 65.6 3.24 0.42 0.54 0.66 62.5 3.64 0.42 0.55 0.67 59. 4.09 0.43 0.56 0.69 ELS20S4D + ELA20S4D - FULL LOAD (2 Compressors Operating) Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 3200 4. 7.03 0.75 0.89 08.5 7.92 0.77 0.92 02.3 8.92 0.79 0.94 95.9 0.07 0.8 0.97 63 F 4000 20 7.07 0.8 0.96 4. 7.95 0.82 0.99 08 8.96 0.85 02.2 0.2 0.88 4800 25 7.2 0.86 9.7 8.0 0.88 4. 9.04 0.9 07.7 0.9 0.94 3200 22.2 7.09 0.59 0.72 0.85 6.3 7.98 0.6 0.74 0.88 09.9 8.97 0.6 0.76 0.9 03. 0.4 0.62 0.78 0.94 67 F 4000 28. 7.5 0.62 0.78 0.93 2.9 8.03 0.63 0.8 0.95 5 9.04 0.65 0.82 0.98 07.7 0.8 0.67 0.85 4800 32.5 7.9 0.65 0.83 0.99 25.7 8.07 0.67 0.86 8.7 9.08 0.69 0.88 0.9 0.22 0.7 0.92 3200 30.2 7.7 0.45 0.57 0.7 24. 8.05 0.45 0.58 0.7 7.7 9.06 0.45 0.59 0.73 0.5 0.22 0.46 0.6 0.75 7 F 4000 36.6 7.23 0.46 0.6 0.75 29.9 8.2 0.46 0.62 0.77 22.9 9.3 0.47 0.63 0.79 5.5 0.28 0.47 0.65 0.82 4800 4. 7.28 0.47 0.64 0.8 34.2 8.6 0.48 0.66 0.83 26.8 9.9 0.48 0.67 0.85 8.9 0.32 0.49 0.7 0.89 ELS50S4D + ELA50S4D - PART LOAD ( Compressor Operating) Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 2800 68.9 3.7 0.67 0.77 0.88 66.2 3.62 0.68 0.79 0.89 63.3 4. 0.69 0.8 0.9 60.3 4.67 0.7 0.82 0.93 63 F 3500 73.2 3.2 0.7 0.82 0.94 70.2 3.65 0.7 0.83 0.95 67 4.5 0.72 0.85 0.97 63.5 4.7 0.74 0.88 4200 76.3 3.23 0.73 0.87 0.99 73. 3.68 0.75 0.89 69.7 4.7 0.76 0.9 66 4.73 0.78 0.93 2800 73.2 3.2 0.54 0.64 0.74 70.3 3.65 0.55 0.65 0.75 67.3 4.4 0.55 0.66 0.76 64. 4.7 0.56 0.67 0.78 67 F 3500 77.7 3.25 0.56 0.68 0.79 74.5 3.69 0.57 0.69 0.8 7.2 4.9 0.57 0.7 0.82 67.6 4.74 0.58 0.7 0.84 4200 8 3.28 0.58 0.7 0.84 77.7 3.72 0.59 0.72 0.85 73.9 4.2 0.6 0.74 0.87 70 4.77 0.6 0.75 0.9 2800 77.5 3.25 0.43 0.53 0.62 74.5 3.69 0.43 0.53 0.63 7.4 4.9 0.43 0.53 0.63 67.9 4.74 0.43 0.54 0.65 7 F 3500 82.2 3.28 0.43 0.54 0.65 78.9 3.73 0.44 0.55 0.66 75.4 4.23 0.44 0.56 0.67 7.6 4.78 0.44 0.57 0.69 4200 85.6 3.32 0.44 0.56 0.68 82. 3.77 0.45 0.57 0.7 78.4 4.26 0.45 0.58 0.7 74.2 4.82 0.45 0.59 0.73 ELS50S4D + ELA50S4D - FULL LOAD (2 Compressors Operating) Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 4000 38 8.32 0.75 0.9 3. 9.44 0.77 0.92 23.5 0.75 0.79 0.95 5.4 2.26 0.82 0.98 63 F 5000 44.3 8.37 0.8 0.97 36.8 9.5 0.83 0.99 29.3 0.8 0.85 22 2.35 0.89 6000 49.6 8.43 0.86 42.9 9.57 0.89 35.6 0.87 0.9 27.7 2.38 0.95 4000 46.8 8.4 0.59 0.73 0.86 39.3 9.52 0.6 0.74 0.88 3.5 0.82 0.6 0.76 0.9 22.6 2.33 0.63 0.79 0.94 67 F 5000 52.7 8.46 0.63 0.78 0.94 45 9.59 0.64 0.8 0.96 36.7 0.88 0.66 0.83 0.99 27.4 2.38 0.67 0.86 6000 57.4 8.5 0.66 0.84 0.99 49. 9.63 0.67 0.87 40.2 0.92 0.69 0.89 30.6 2.42 0.72 0.93 4000 55.2 8.49 0.44 0.58 0.7 47.6 9.6 0.45 0.59 0.72 39.4 0.9 0.45 0.6 0.74 30.4 2.4 0.46 0.6 0.77 7 F 5000 6.7 8.56 0.46 0.6 0.76 53.4 9.68 0.46 0.62 0.78 44.8 0.97 0.47 0.64 0.8 35.2 2.47 0.48 0.66 0.84 6000 66.3 8.6 0.47 0.65 0.82 57.7 9.73 0.48 0.67 0.84 48.6.02 0.49 0.68 0.87 38.6 2.52 0.5 0.7 0.9 ELS 6 to 20 Ton Air Conditioners / Page 6

RATINGS NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. ELS80S4D + ELA80S4D - PART LOAD ( Compressor Operating) Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 3200 85.9 4.62 0.65 0.75 0.84 82.6 5.6 0.66 0.76 0.85 79 5.74 0.67 0.77 0.86 75.2 6.44 0.68 0.78 0.88 63 F 4000 92. 4.69 0.67 0.78 0.88 88.4 5.22 0.68 0.79 0.9 84.5 5.82 0.69 0.8 0.92 80. 6.48 0.7 0.83 0.94 4800 96.9 4.75 0.7 0.82 0.93 92.7 5.28 0.7 0.83 0.95 88.5 5.87 0.72 0.85 0.97 83.9 6.53 0.74 0.87 0.99 3200 9 4.68 0.54 0.63 0.7 87.5 5.2 0.54 0.63 0.72 83.7 5.8 0.54 0.64 0.73 79.8 6.47 0.55 0.65 0.75 67 F 4000 97.5 4.75 0.55 0.65 0.75 93.7 5.28 0.55 0.66 0.76 89.5 5.87 0.56 0.67 0.77 85. 6.55 0.56 0.68 0.79 4800 02.3 4.82 0.56 0.67 0.78 98.5 5.35 0.57 0.68 0.8 93.9 5.93 0.57 0.7 0.82 89 6.6 0.58 0.7 0.84 3200 96 4.75 0.43 0.5 0.6 92.3 5.27 0.43 0.52 0.6 88.5 5.87 0.43 0.52 0.6 84.3 6.54 0.43 0.53 0.62 7 F 4000 02.6 4.83 0.42 0.53 0.62 98.9 5.35 0.43 0.53 0.63 94.6 5.95 0.44 0.54 0.64 89.9 6.6 0.44 0.55 0.65 4800 07.8 4.9 0.44 0.55 0.65 03.8 5.42 0.44 0.55 0.66 99.3 6 0.44 0.56 0.67 94.2 6.67 0.44 0.57 0.68 ELS80S4D + ELA80S4D - FULL LOAD (2 Compressors Operating) Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 4800 8.4.62 0.72 0.85 0.97 72.2 2.96 0.74 0.87 0.99 62.2 4.52 0.75 0.9 5.3 6.32 0.78 0.93 63 F 6000 90.7.7 0.76 0.9 80.5 3.05 0.78 0.94 69.7 4.6 0.8 0.96 58.3 6.37 0.83 0.99 7200 97.4.79 0.8 0.97 86.8 3. 0.83 0.99 76 4.65 0.86 65.8 6.46 0.89 4800 92.5.74 0.57 0.7 0.8 82.8 3.08 0.58 0.7 0.84 72.6 4.62 0.59 0.73 0.86 6.4 6.39 0.6 0.75 0.89 67 F 6000 202.5.85 0.6 0.74 0.88 9.8 3.7 0.6 0.76 0.9 80.7 4.7 0.62 0.78 0.93 68.6 6.46 0.64 0.8 0.96 7200 209.3.92 0.62 0.78 0.94 98.4 3.25 0.64 0.8 0.96 86.7 4.79 0.65 0.83 0.99 73.9 6.55 0.67 0.86 4800 203.4.87 0.44 0.56 0.67 93.4 3.9 0.44 0.56 0.68 82.8 4.75 0.45 0.58 0.7 7.4 6.52 0.45 0.59 0.72 7 F 6000 23.8.97 0.45 0.58 0.7 202.9 3.3 0.45 0.6 0.73 9.8 4.84 0.46 0.6 0.75 79 6.59 0.47 0.63 0.78 7200 22 2.07 0.46 0.6 0.76 20 3.4 0.47 0.62 0.78 97.6 4.92 0.47 0.64 0.8 84.7 6.68 0.48 0.66 0.84 ELS240S4D + ELA240S4D - PART LOAD ( Compressor Operating) Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F 4500 5 5.74 0.68 0.77 0.87 0.8 6.38 0.68 0.78 0.87 06.7 7. 0.68 0.78 0.88 02.2 7.99 0.68 0.8 0.89 63 F 5500 20.6 5.78 0.68 0.79 0.89 6.4 6.4 0.68 0.79 0.9.9 7.6 0.69 0.8 0.9 06.7 8.02 0.69 0.8 0.89 6500 25.5 5.83 0.69 0.8 0.89 20.9 6.47 0.69 0.82 0.89 5.9 7.2 0.69 0.82 0.89 0.7 8.06 0.7 0.83 0.88 4500 22.7 5.8 0.56 0.65 0.74 8.3 6.44 0.55 0.65 0.74 3.9 7.6 0.55 0.65 0.75 09. 8.02 0.55 0.66 0.76 67 F 5500 28.7 5.86 0.54 0.65 0.75 24.7 6.49 0.53 0.66 0.76 9.6 7.23 0.55 0.66 0.77 4.3 8.09 0.55 0.66 0.77 6500 33.4 5.9 0.53 0.66 0.77 28.5 6.54 0.54 0.66 0.78 23. 7.25 0.54 0.65 0.78 7.7 8.09 0.54 0.66 0.79 4500 30.9 5.88 0.44 0.53 0.62 26.5 6.5 0.44 0.53 0.62 2.8 7.24 0.43 0.53 0.62 6.6 8.08 0.42 0.52 0.62 7 F 5500 36.3 5.93 0.42 0.5 0.6 32. 6.56 0.4 0.52 0.63 27.3 7.29 0.4 0.53 0.63 2.7 8.5 0.4 0.52 0.63 6500 40.9 5.97 0.39 0.5 0.62 36 6.6 0.39 0.5 0.63 30.6 7.3 0.39 0.5 0.62 25 8.5 0.37 0.5 0.63 ELS240S4D + ELA240S4D - FULL LOAD (2 Compressors Operating) Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F 6400 227.7 4.3 0.7 0.83 0.89 27.3 5.86 0.7 0.83 0.88 205.8 7.6 0.7 0.84 0.88 94.4 9.64 0.72 0.84 0.87 63 F 8000 238.6 4.48 0.7 0.84 0.87 228.2 6.04 0.7 0.83 0.86 27.9 7.84 0.73 0.82 0.86 206.4 9.86 0.73 0.8 0.85 9600 249.7 4.67 0.72 0.82 0.85 239 6.23 0.73 0.8 0.84 227.3 8 0.73 0.8 0.84 24.9 20.02 0.73 0.79 0.83 6400 243.5 4.56 0.54 0.67 0.79 23.8 6. 0.54 0.67 0.8 29.2 7.85 0.54 0.68 0.8 206. 9.86 0.53 0.68 0.82 67 F 8000 252.4 4.72 0.52 0.67 0.8 240.2 6.25 0.53 0.68 0.8 227.2 8 0.52 0.69 0.8 22.6 9.96 0.52 0.69 0.79 9600 259.4 4.83 0.5 0.69 0.79 245.9 6.35 0.5 0.69 0.78 23.9 8.09 0.5 0.69 0.77 27. 20.06 0.5 0.7 0.76 6400 257.8 4.8 0.39 0.52 0.63 245.8 6.35 0.39 0.5 0.64 232.8 8. 0.38 0.5 0.64 28.8 20.08 0.37 0.5 0.65 7 F 8000 267. 4.97 0.35 0.5 0.64 254.6 6.5 0.34 0.5 0.64 240.6 8.24 0.33 0.5 0.65 225.9 20.22 0.32 0.49 0.66 9600 274 5.08 0.3 0.49 0.65 260.6 6.6 0.3 0.49 0.65 246.2 8.35 0.29 0.48 0.66 23 20.33 0.28 0.48 0.66 ELS 6 to 20 Ton Air Conditioners / Page 7

Visit us at www.allied-commercial.com For the latest technical information, visit us at www.allied-commercial.com Contact us at -800-738-4000 NOTE - Due to Allied Commercial ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 208 Allied Air Enterprises LLC, a Lennox International Inc. Company