Callisto 100. Cold Filter Plugging Point Tester

Similar documents
ADU 5. Automatic Distillation Unit

Stabinger Viscometer SVM 3001

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Stabinger Viscometer Series. SVM Series

Innovation in cold behavior

Instruments for Chemical and Petroleum Products. Flash Point

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Innovation in cold behavior

CFPP Process Analyzer

Low cost EDXRF elemental analyzer

Sulfur in Oil Analyzer

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

SVM Stabinger Viscometer. ::: Viscometry at its best

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Refrigerated incubator with Peltier technology

STABILITY TESTING CLIMATIC CHAMBER

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

SWISS MADE EXECUTIVE. Series 360 ES

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels 1

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

MODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

IROX 2000 IROX DIESEL

Battery-Powered Flow Transmitter

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

Infinite F50 family Reliable. Validated. Compact.

R-SERIES MULTI-AXIS INDUSTRIAL ROBOTS

Laboratory High Precision (0.001 g) Balances

Cooled incubators (ST), laboratory refrigerators

AVL Particle Measurement System Aviation

Flow VA 550 / 570. DVGW tested. Flow.

Vertical Tensile Machine

TechPress 3. Product Brochure MOUNTING PRESS. Quality Products for Metallographic Sample Preparation & Analysis

Thermo Scientific Sorvall MTX and MX Plus Micro-Ultracentrifuge Series. powerful separation technology. quiet, compact design

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

FORCE TENSIOMETER K20 THE STAND-ALONE TENSIOMETER FOR QUALITY CONTROL

6332A / 7342A Temperature Calibration Baths. Fast, 0.01 C stability baths backed by Fluke metrology

DUCOM HIGH FREQUENCY RECIPROCATING RIG

Vehicle Weighing. Vehicle Weighing Solutions. That help drive your business. Vehicle Weighing Solutions

Phase Technology CPA-70Xi Cloud Point Analyzer

Optidew Vision Optical Dew-Point Meter

Picus Electronic Pipette

MAGNA T SERVO. 500 to 5,500 kn

The New Entris. Monolithic weigh cell for long-term high accuracy. Built-in applications and function keys for convenient operation

Elemental Analysis Advanced

Ton-Tel Multi-Deck Weighbridge

SHOCK ABSORBER/DAMPER TESTING MACHINE

LABORATORY. Fuel additives technology.

Cetane ID 510. Customer Presentation. Refining. Petrochemical

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Rotor No.3, No.4, No.5 No.1, No.2, No.3 Cup A, B No.3 Cup Extension Rod - 1 PC Batteries 4pcs, IEC R6 4pcs, IEC R6

Penetration. Test Methods

Installation And Programming Manual of OPTIMA Eco Tec and OPTIMA Pro Tec OBD/CAN

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

BLU SERIES Battery Load Units

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

BLU SERIES Battery Load Units

Phase Technology PPA-70Xi Pour Point Analyzer

Accessories for the measurement of tightening torque. Digital and electronics dynamometric wrenches

Sartorius Cubis Series

Agilent 7693A Automated Liquid Sampler

Flow meters. Flow meters. Flow meters - Continuous and precise measurement of flow rates

B/R Vacuum Distillation ASTM D1160. Fully Automatic Vacuum Distillation According to D1160

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Belt Scales Table of Contents

Closed Cup Flash Point Tester

SANKI is a leading refueling equipment manufacturer in China and leads the industrial technical progress with science and technology.

BRAKE TESTER DECELEROMETER

Precisa Gravimetrics AG

Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Product Information. Mflow extrusion plastometer

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Metal Detector Secus. Benefits

Combustion Calorimeter System

Safety drying oven with expended temperature range

TSHR 7000 series TN-TS-TX analyzer

A Tradition of Competence

Agilent 7693A Automated Liquid Sampler

Don't just Perform Service - Sell It!

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

For commissioning, maintenance and function checks of solar thermal systems Part no

Flash Point Process Analyzer

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

Active Interface Module Active Line Module chassis format, air-cooled

TQC s production facility is located in The Netherlands TQC has distributors in more than 60 countries TQC, DEVELOPERS AND MANUFACTURERS OF PAINT TEST

As diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

BLU SERIES Battery Load Units

Thermo-hygrometer-anemometer VT 210

Thermo-hygrometer-anemometer VT 210

InfraCal 2 Biodiesel Blend Analyzer

Humidity Cabinet HYGROTHERM

FLUID CONTROL SYSTEM. No. 506-FCS EVERYTHING UNDER YOUR CONTROL FCS FULL OPTIONAL FCS BASIC ADVANCED FLUID MANAGEMENT SOLUTIONS

Transcription:

Callisto 100 Cold Filter Plugging Point Tester

Cold Filter Plugging Point The Cold Filter Plugging Point (CFPP) method is used to determine the low-temperature operability of diesel fuel, biodiesel, blends and gas oils. The CFPP is a critical property used to forecast the lowest temperature at which a fuel will freely flow through filters in a diesel engine system. All diesel fuels contain wax. When the temperature of the fuel decreases, wax crystals will begin to precipitate at some point. If a certain amount of wax precipitates, the crystals can block fuel flow through filters and other restricted passages in the fuel system. Low-temperature operability Callisto 100 is a fully automated and compact CFPP tester operated by a touchscreen. It contains all required components according to the standard method. Testing and results are in full compliance with ASTM D6371, EN 116, EN 16329, JIS K 2288 and IP 309. Pump Filter Additionally, Callisto 100 can be used for manual cloud and pour point measurements. With the optional kit measurements can be performed according to the standard methods ASTM D2500, ISO 3015, EN 23015, JIS K 2601, IP 219 (cloud point) and ASTM D97, ASTM D5853, ISO 3016, JIS K 2269, IP 15, IP 441 (pour point). To cool the sample in the cooling jacket an external cooling system is required. Based on more than 30 years of Anton Paar s experience in Peltier element technology, Callisto 100 comes with a newly developed state-of-the-art Peltier element technology which allows the connection of a methanol-free cooling system. Low-temperature operability is an issue with diesel fuels because they contain paraffin waxes that become solid at ambient winter temperatures. Climate requirements for diesel fuel -20 C Diesel fuel for moderate climates -44 C Diesel fuel for extreme arctic climates

Test principle Wax crystals may block the diesel fuel flow through the filter According to the strict guidelines described in the applicable standards, a given portion of a fuel is cooled under the specified conditions and is drawn into a pipette under a controlled vacuum through a standardized wire mesh filter. The test is repeated when the sample has cooled by an additional 1 C. At the temperature at which the sample can no longer be filled into the pipette within 60 seconds the test is finished, and the temperature is displayed as the CFPP test result. Benefits at a glance ``Error-free detection ``Easy and intuitive operation ``High sample throughput ``Convenient cleaning routines Tank ``Peltier elements for high homogeneity of the cooling jacket supported by an external methanol-free cooling system These wax crystals may plug the fuel filter, making it impossible for the fuel system to deliver fuel to the engine. There are a number of procedures in refineries to improve a fuel s low-temperature operability, e.g. by treating a fuel with additives or manufacturing it from crude oils with lower wax content. Callisto 100 is the first choice for evaluating the quality and drivability of diesel fuels at low temperatures or even under extreme arctic climate conditions.

Callisto 100 Easy and Precise CFPP Testing Error-free detection Thanks to contact-free infrared detection technology the complete filtration unit is easily accessible and has the same detection position in each test. This ensures high accuracy and repeatability. Easy and intuitive operation Start your tests immediately: Callisto 100 comes with pre-programmed standard test methods to select from the menu. If you want to customize your test routines, you can create and store up to 90 individual user programs. Testing accuracy is enhanced by user-friendly calibration procedures for the temperature and vacuum a standard delivery feature of Callisto 100. The large color display indicates the sample and jacket temperature in real time and provides additional graphical information about the aspiration and flow back times to observe the temperature behavior of the sample during the test. For statistics, Callisto 100 offers a result history for 1000 tests as well as the statistical evaluation of test results according to the test method. Callisto 100 provides versatile connectivity via USB and LAN, e.g. to export test results as Excel or PDF files, or to connect a bar code reader for sample identification.

High sample throughput Callisto 100 has minimum downtime. Once you have prepared a second complete test assembly and put it into the storage place at the rear of the instrument, you are ready to go for the next test run within seconds. Convenient cleaning routines To make the cleaning of the pipette as easy as possible, a programmable automated cleaning routine can be initiated at the push of a button. Excellent homogeneity of the cooling jacket State-of-the-art Peltier element technology ensures outstanding homogeneity of the cooling jacket which is the most critical and decisive parameter for a correct CFPP value determination. You can also use Callisto 100 for manual cloud and pour point measurements.

Explore in Detail Accurate detection Thanks to contact-free infrared detection technology, the complete filtration unit is easily mounted into and removed from the cooling jacket. This results in the same accurate detection position for each test and guarantees excellent repeatability of test results. The pipette is not shielded and has no thermal insulation. In addition, Callisto 100 delivers excellent detection, even when the pipette is frosted. There is no interference from daylight. Extended cooling profiles In addition to the well-established stepped cooling method, Callisto 100 meets the requirements of the alternative standard method EN 16329 with linear cooling of the sample. The EN 16329 is now part of the EN 590 European Diesel specification as an alternative test method to EN 116. Callisto 100 requires an external cooling device: An inexpensive and methanol-free counter-cooling system with antifreeze is already sufficient. The cooling system is only used to support the Peltier elements to reach a minimum jacket temperature of -70 C and to measure samples with a CFPP value below -35 C. High flexibility and efficiency For more flexibility and fast handling, the complete filtration unit is easily disassembled for cleaning and re-assembled for the next CFPP test. This cleaning procedure is required by the standard methods to verify the cleanliness and dryness of all elements in order to obtain precise test results. An additional complete test assembly can be prepared while a test is in progress and stored at the rear of the instrument. This allows you to start the next test run within seconds, minimizing the downtime between subsequent tests and maximizing the throughput for optimized lab efficiency.

Technical Specifications Standard methods ASTM D6371, EN 116, EN 16329, JIS K 2288, IP 309 With optional kit for manual cloud and pour point measurement: ASTM D2500, ISO 3015, EN 23015, JIS K 2601, IP 219 (cloud point) ASTM D97, ASTM D5853, ISO 3016, JIS K 2269, IP 15, IP 441 (pour point) Operation Detection Temperature range of measuring chamber 2 infrared contactless detection barriers -70 C to 48 C (accuracy according to applied standard test method) Measuring range -60 C to 45 C Vacuum Cooling profiles Temperature measurement Cleaning Password security Calibration Languages Electronically controlled Programmable stepped or linear (from 6 C/h to 100 C/h) C or F, Pt100 Programmable cleaning cycles Multi-level password protection ``Automatic calibration routine for sample and jacket temperature and vacuum measurement ``Temperature probe correction table English, German, Spanish, French, Portuguese, Chinese Documentation Data memory Data export Interfaces Data input options Display ``1000 results ``90 user-defined programs ``Export of measurement results to memory stick (PDF, XLS) ``Printout of data on a ticket printer or all supported Anton Paar printers 3x USB (back), 1x USB (front), 1x RS232, 1x LAN, 1x VGA Bar code reader, keyboard, mouse Color touchscreen Requirements and dimensions Power supply AC 100 V to 240 V, 50/60 Hz, 290 VA Ambient temperature 10 C to 35 C Air humidity External cooling unit Cooling liquid connections Max. 80 % relative humidity ``User-supplied or available from Anton Paar as an accessory ``Cooling power: 280 W at -20 C Hose nozzles with inner diameter 8 mm (0.3 inches) Cooling liquid volume Water or water-glycol mixture (ratio 3:2) Flow volume of cooling liquid Temperature of the coolant Coolant 3 L/min (at counter-cooling temperature) -23 C to 10 C working range ``-20 C to -23 C: jacket temperature down to -70 C ``-10 C or lower: jacket temperature down to -51 C ``10 C or lower: jacket temperature down to -34 C Dimensions 340 mm x 580 mm x 310 mm (W x D x H) Weight net 14 kg

2016 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. H26IP002EN-E