How to Order Manifold. Kit type L8 B4 B6 B8 LM

Similar documents
Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

VQ1000. How to Order Manifold. Kit type

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

5 Port Solenoid Valve

How to Order Manifold. Option Symbol

5 Port Solenoid Valve

5 Port Solenoid Valve

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Plug Lead Unit: Flip Type

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Base Mounted Plug-in/Plug Lead: Single Unit

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VQZ1000/2000/3000 Single Unit

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

5 Port Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve Plug Lead Type

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

Specifications. Fluid Ambient and fluid temperature ( C)

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

5 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

4 Port Solenoid Valve

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Pilot Operated 2 Port Solenoid Valve for Dry Air

4 Port Solenoid Valve

Series SY3000/5000/7000

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Example. U side. Stations SY5000

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Fieldbus System (Output device for driving 5 port solenoid valves)

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series SY3000/5000 How to Order Manifold

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series SV1000/2000/3000/4000

3 Port Solenoid Valve Direct Operated Poppet Type

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Series SY3000/5000/7000

4/5 Port Solenoid Valve

5 Port Solenoid Valve

Series VP3145/3165/3185

5 Port Solenoid Valve

0.35 W (Without light)

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

New Concept Connector Type Manifold

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

3 Port Air Operated Valve

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

3 Port Solenoid Valve

Series PCW. PC Wiring System

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Fieldbus System (Gateway Decentralized Type)

Vacuum / Release Unit

2.26 S OLENOID VALVES S ERIES VQ1000

3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Non-Contact Sensor for Workpiece Placement Verification

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

4/5 Port Solenoid Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Transcription:

0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port How to Order Manifold F U Kit type Symbol Port size Symbol Port size C C C8 CM L L With One-touch fitting for ø With One-touch fitting for ø With One-touch fitting for ø8 With mixed size/with port plug () W/ elbow One-touch fitting ø for top piping W/ elbow One-touch fitting ø for top piping L8 8 LM W/ elbow One-touch fitting ø8 for top piping W/ elbow One-touch fitting ø for bottom piping W/ elbow One-touch fitting ø for bottom piping W/ elbow One-touch fitting ø8 for bottom piping Mixed size for elbow piping Note ) Specify Mixed size/with port plug on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. For details, refer to page --79. Simple specials are available with SMC Simple Specials System. For details about applicable models, Contact SMC. For details about certified products conforming to international standards, visit us at www.smcworld.com. Symbol Nil D K N R S W ack pressure check valve () DIN rail mounting style Special wiring specifications (Except double wiring) () With name plate External pilot () uilt-in silencer, direct exhaust Enclosure: Dust tight/splashproof type (IP) [T, L, S and M s only] Note ) When two or more symbols are specified, indicate them alphabetically. Example) -DNR. Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold. If not all need this check valve, specify the where check valves are installed by manifold specification sheet. Note ) Specify the wiring specifications in the manifold specification sheet. (Except L ) Note ) Indicate R for the valve with external pilot. Kit/Electrical entry/cable length F (D-sub connector) Side entry P J G (Flat ribbon cable connector) (Flat ribbon cable connector (0P)) Side entry (Flat ribbon cable connector with power supply terminal block) Compatible only with VDC valves. Note ) P Top entry Note ) P Top entry Note ) P Top entry Connector entry direction Top entry Side entry Kit F U0 U U U Kit F S0 S S S P. --0 Connector entry direction Connector entry direction P. -- Top entry Side entry Top entry Side entry P. --8 P. -- Without cable U0 S0 Without cable U0 S0 Without cable U0 Without cable () () () () With cable (. m) to Kit U Kit S With cable (. m) to Kit U Kit S With cable (. m) to Kit U With cable (. m) to With cable ( m) With cable ( m) P U U P S S With cable ( m) With cable ( m) J U U J S S With cable ( m) With cable ( m) G U U With cable ( m) With cable ( m) --

Plug-in Unit ase Mounted Series VQ000 How to Order Valves VQ 0 0 Y Series VQ000 Type of actuation position single Metal Rubber position double position double position closed center position exhaust center position pressure center position dual port valve () N.C N.C position dual port valve () N.O N.O position dual port valve (C) C Seal N.C N.O Rubber seal type only. 0 Metal seal Rubber seal Note ) For sub-plate single unit type, refer to page --. Light/Surge voltage suppressor Nil Yes E Inapplicable to the S. Enclosure Nil Dust-protected W Dusttight/Low jetproof type (IP) Manual override Nil: Non-locking : Push-locking push type slotted type (tool required) Coil voltage Function Symbol Specifications DC C 00 VC (0/0 Hz) 00 VC (0/0 Hz) Nil H Standard (.0 W) 0 VC (0/0 Hz) type 0 VC (0/0 Hz) High (. W) VDC pressure type VDC Low wattage (0. W) 00/0 VC Y type models are applicable to F For power consumption and L s. of C type, refer to page --9. For external pilot and negative COM specifications, refer to on page --78 to --79. C: Locking type (Manual) How to Order Manifold ssembly Example Double solenoid ( VDC) VQ00- ( sets) Single solenoid ( VDC) VQ00- ( sets) Stations lanking plate VQ000-0- ( set) D-sub connector XT00-DS-00 F Cylinder ports (D-sub connector) C8: With One-touch fitting for ø8 Manifold base (8 ) VVQ-08C8FU VVQ-08C8FU set (F 8 station manifold base no.) VQ00- sets (Single solenoid part no.) VQ00- sets (Double solenoid part no.) VVQ000-0- set (lanking plate part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Specify the part numbers for valves and options together beneath the manifold base part number. esides, when the arrangement will be complicated, specify them by means of the manifold specification sheet. VQC SQ VQ0 VQ VQ VQZ VQD T Kit T (Terminal box) Dust tight/low jetproof type (IP) available O Terminal block box P. -- to 0 () L (Lead wire cable) Dust tight/low jetproof type (IP) available Kit L 0 P. --0 With cable (0. m) to 8 With cable (. m) With cable ( m) S M (Serial transmission unit) () (Multi-connector) The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is VDC. The dusttight SI unit is available. Refer to page -- for details. Dusttight/splashproof type (IP) is also available. (Except SE and SG.) Note ) esides the above, F and P s with different number of pins are available. Refer to page --77 for details. Note ) For details, refer to page --78. Note ) Refer to the pages on respective s for IP type. (T, L and S s) Note ) Kits with IP enclosure applicable to input/output are also available. Refer to page -- for details. Kit S O () Mitsubishi Electric Corp.: MELSECNET/MINI-S Data Link System( power supply lines) C D E F G H J J K Q R R V P. -- Without SI unit With general type SI unit (Series EX00) Mitsubishi Electric Corp.: MELSECNET/MINI-S Data Link System OMRON Corp.: SYSUS Wire System SHRP Corp.: Satellite I/O Link System Matsushita Electric Works: MEWNET-F System NKE Corp.: Uni-wire System ( output points) Rockwell utomation: llen radley Remote I/O (RIO) System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System ( output points) SUNX Corp.: S-LINK System (8 output points) Fuji Electric Co.: T-LINK Mini System DeviceNet, Compous/D (OMRON Corp.) OMRON Corp.: Compous/S System ( output points) OMRON Corp.: Compous/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System () Max. Dust tight/ Low jetproof type Max. (IP) only available () Max. Max. 8 Max. Kit Max. 8 M Max. 0 P. -- Without cable With cable (. m) With cable ( m) With cable ( m) () to --

ase Mounted Series VQ000 Manifold P. --0 lanking plate assembly VVQ000-0- SUP block plate VVQ000- DIN rail mounting bracket [-D] VVQ000-7 Port plug VVQ000-8 Individual SUP spacer VVQ000-P--C8 EXH block plate VVQ000-9 uilt-in silencer, direct exhaust [-S] lanking plug 0 0 KQP- 08 0 C8 (SUP port) One-touch fitting for ø8 Exhaust port Individual EXH spacer VVQ000-R--C8 C8 (EXH port) One-touch fitting for ø8 Name plate [-N] VVQ000-N-Station ( to Max. ) Silencer (For EXH port) N00-KM0 For cylinder port fittings part no., refer to page --7. For replacement parts, refer to page --7. ack pressure check valve assembly [-] VVQ000-8 Elbow fitting assembly VVQ000-F-L (C, C, C8) matching fitting assembly VVQ000--C0 Double check block VQ000-FPG- To CYL port --

Plug-in Unit ase Mounted Series VQ000/000 Metal Rubber position double position double position closed center position exhaust center position pressure center Manifold Specifications Series VQ000 JIS Symbol position single ase model VVQ- Type of connection Standard Specifications Solenoid Valve specifications Note ) Note ) Note ) Note ) Note ) F D-sub connector P Flat ribbon cable connector J Flat ribbon cable connector (0P) G Flat ribbon cable connector with terminal block T Terminal box L Lead wire cable S Serial transmission unit Valve construction Fluid Maximum operating pressure Minimum operating pressure Single Double position mbient and fluid temperature Lubrication Manual override () Impact/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Power consumption (Current) Port location Side VDC VDC 00 VC 0 VC 00 VC 0 VC Porting specifications () Port size (P), (R) (), () C8 (ø8) uilt-in silencer, direct exhaust Metal seal Rubber seal ir/inert gas ir/inert gas 0.7 MPa (High pressure type: 0.8 MPa) 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0 to 0 C () F, P, T s to J, G, S to L to 8 Not required Push type/locking type (Tool required, Manual type) 0/0 m/s Dust-protected, Dust tight/low jetproof type (IP) (), VDC, 00, 0, 00, 0 VC (0/0 Hz) ±0% of rated voltage Class or equivalent W DC ( m),. W DC ( m) (), 0. W DC ( m) () W DC (8 m),. W DC ( m) (), 0. W DC ( m) () Inrush. V ( m), Holding. V ( m) Inrush. V ( m), Holding. V ( m) Inrush. V ( m), Holding. V ( m) Inrush. V ( m), Holding. V ( m) Use dry air to prevent condensation when operating at low temperatures. Impact resistance No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Vibration resistance No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Value for high voltage type (. W) Value for low voltage type (0. W) Dusttight/Low jetproof type (IP) is available on T, L, S and M s of VQ000. C (ø.) C(ø) C (ø) M (M thread) () pplicable pplicable solenoid valve VQ 00 VQ 0 station weight (g) 8 (Single) 79 (Double, position) VQC SQ VQ0 VQ VQ VQZ VQD VQ000 VVQ- Note ) Note ) F D-sub connector P Flat ribbon cable connector J Flat ribbon cable connector (0P) G Flat ribbon cable connector with terminal block T Terminal box L Lead wire cable S Serial transmission unit M Multi-connector Side Inch-size One-touch fittings are also available. For details, refer to page --79. For details, refer to page --78. C0 (ø0) uilt-in silencer, direct exhaust C (ø) C (ø) C8 (ø8) F, P s to J, G, S to L to 8 T to 0 VQ 00 VQ 0 0 (Single) (Double, position) R port R port Type of connection, port P port, port P port Type of connection --9

M VQ000 Kit (Flat ribbon cable connector) MIL flat cable connector reduces installation labor for electrical connection. Manifold and connectors, both compliant with the IP rating (dusttight, low jetproof), provide a high degree of protection for the electrical parts. Maximum are. Circular Connector ( pins) Manifold Specifications VVQ Porting specifications Series Port Port size location (P), (R) (), () VQ000 Side C0 C, C, M8 VQ000 only pplicable Max. XT00-MC- 0 00 00 Circular connector assembly included in a specific manifold model no. specific manifold model no. Refer to How to Order Manifold. L 0 0 7 8 9 0 0 7 8 9 Multi-core vinyl cable 0. mm x C ~= ø0 Plug terminal no. Socket side Circular Connector Cable ssembly () Cable length (L). m m m ssembly part no. XT00-MC-0 XT00-MC-00 XT00-MC-00 Note Cable core x WG Electric Characteristics Item Characteristics Conductor resistance Ω/km, 0 C or less Voltage limit V, min, C 000 Insulation resistance or more MΩkm, 0 C The minimum bending radius of circular connector cable is 0 mm. Terminal no. Lead wire color Dot marking 7 8 9 0 7 8 9 0 Cable assembly Circular Connector Cable ssembly Terminal No. rown Yellow Pink lue Purple Gray Yellow Yellow Pink lue Purple Gray rown Pink Gray How to Order Manifold M VVQ 08 C N W Enclosure IP (Dust tight/low jetproof type) --8 Series VQ000 Manifold Plug-in unit Stations 0 For details, refer to page --78. 0 Cylinder port Symbol C C C8 CM Cable (Length) Without cable With cable (. m) With cable ( m) With cable ( m) Port size With One-touch fitting for ø With One-touch fitting for ø With One-touch fitting for ø8 With mixed size/with port plug Note ) Insert L (top piping) or (bottom piping) for elbow type. Example) (Elbow One-touch fittings for ø, bottom piping.) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Specify Mixed size/with port plug in the manifold specification sheet. Note ) Inch-size One-touch fittings are available. For details, refer to page - 7-79. Symbol Nil D K N R Note ) Note ) Note ) Note ) With back pressure check valve DIN rail mounting Special wiring specifications (Not double wiring) With name plate External pilot Note () () () When two or more symbols are specified, indicate them alphabetically. Example) -KR Models with a suffix - have check valves for prevention of back pressure at all manifold. If not all need this check valve, specify the where check valves are installed by using the manifold specification sheet. Specify the wiring by using of the manifold specification sheet. Indicate R for the valve with external pilot.

Plug-in Unit ase Mounted Series VQ000/000 Stations Stations VVQ The total number of is tabulated starting from station one on the D side. Electrical wiring specifications 7 8 9 0 0 9 8 7 s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL. ) is adopted for the internal wiring of each station for or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page -7-78. station { { { { { { 7 { 8 { 9 { 0 { { { (Max.) When using the negative common specifications, use valves for negative common. (Refer to page --78.) For details, refer to on page --78. Terminal no. Polarity Lead wire colordot marking SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. COM. 7 8 9 0 7 8 9 0 Positive common specifications Circular connector cable assembly 0 XT00-MC- 00 Wire Color 00 rown Yellow Pink lue Purple Gray Yellow Yellow Pink lue Purple Gray rown Pink Gray Negative common specifications VQC SQ VQ0 VQ VQ VQZ VQD How to Order Valves Type of actuation VQ 0 0 Y W Series VQ000 position single position double position closed center position exhaust center position pressure center 0 Seal Metal seal Rubber seal For external pilot and negative COM specifications, refer to on --78 to --79. Function Symbol Specifications Standard Nil type H Y High pressure type Low wattage type Manual override Non-locking push type Nil (Tool required) Locking type (Tool required) C Locking type (Manual) Light/Surge voltage suppressor Nil E DC (.0 W) (. W) (0. W) Yes C For power consumption of C type, refer to page -- 9. Enclosure IP (Dusttight/ Low jetproof type) Coil voltage 00 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC m How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Flat ribbon cable with m cable VVQ-09CM-W set Manifold base no. VQ00-w sets Valve part no. (Stations to ) VQ00-w sets Valve part no. (Stations to ) VQ00-w sets Valve part no. (Stations 7 to 8) VVQ000-0- set lanking plate part no. (Station 9) Prefix the asterisk to the part nos. of the solenoid valve, etc. Stations When ordering, specify the part nos. in order from the st station in the D side. When part nos. written collectively are complicated, specify by using the manifold specification sheet. --9

M VQ000 Kit (Flat ribbon cable connector) VQ000 The broken lines indicate the DIN rail mounting style [-D] and the side entry connection [-FS]. 9. <8> 7 CONINVERS HC-PNRWF00 (L) (L) (.) L L 9 Manual.. Indicator light override Mounting hole for -M <.> 7 (.) () 7. 0. 80 ~ =. () D side Stations 7 8 n U side -C0 R (EXH) port -C0 P (SUP) port DIN rail clamp screw () 9.. 9. < >: C 7 P = n-c, C, C8 C: One-touch fitting for ø C: One-touch fitting for ø C8: One-touch fitting for ø8 (7.) Dimensions L L L (L) (L) n Formula L = n + 77., L = n + 00. n: Station (Maximum ) 7 8 9 0.. 7. 7. 89. 0.. 7.. 8.. 80. 9.. 8.. 0. 7. 7 87. 00 7. 0 7 87. 00 8. 98 0.. 8 0. 8. 98 0. 09... 7 9. 9.. --0

ase Mounted Series VQ000 Manifold Parts for VQ000 lanking plate assembly VVQ000-0- It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. JIS Symbol Individual SUP spacer VVQ000-P--C8 When the same manifold is to be used for different pressures, individual SUP spacers are used as SUP ports for different pressures. (One station space is occupied.) lock both sides of the station, for which the supply pressure from the individual SUP spacer is used, with SUP block plates. (Refer to the application ex.) Specify the spacer mounting position and SUP block plate position on the manifold specification sheet. The block plate are used in two places for one set. (Two SUP block plates for blocking SUP station are attached to the individual SUP spacer.) Electric wiring is connected to the position of the manifold station where the individual SUP spacer is mounted. SUP block plate Individual SUP spacer C8 (SUP port) One-touch fitting for ø8 D side Shut off label (R) label indicating the SUP passage (P) blocking position is to be adhered. (R) SUP block plate SUP block plate Valve Individual Valve Valve SUP spacer U side Individual EXH spacer VVQ000-R--C8 When valve exhaust affects other due to the circuit configuration, this spacer is used for individual valve exhaust. (One station space is occupied.) lock both sides of the individual valve EXH station. (See example) Specify the mounting position, as well as the EXH block base or EXH block plate position on the manifold specification sheet. The block plates are used in two places for one set. (Two EXH block plates for blocking EXH station are attached to the individual EXH spacer.) Electric wiring is connected to the position of the manifold station where the individual EXH spacer is mounted. EXH block plate Individual EXH spacer C8 (EXH port) One-touch fitting for ø8 Shut off label label indicating the EXH passage blocking position is to be adhered. EXH block plate EXH block plate D side Valve Individual Valve Valve EXH spacer U side SUP block plate VVQ000- When different pressures, high and low, are supplied to one manifold, a SUP block plate is inserted between the under different pressures. Specify the number of on the manifold specification sheet. <locking indication label> When using block plates for SUP passage, indication label for confirmation of the blocking position from outside is attached. (One label of each) Shut off label SUP passage blocked SUP/EXH passage blocked When ordering a block plate incorporated with the manifold no., a block indication label is attached to the manifold. EXH block plate VVQ000-9 The EXH block plate is used between for which exhaust is desired to be divided when valve exhaust affects other due to the circuit configuration. It is also used in combination with an individual EXH spacer for individual exhaust. Specify the number of on the manifold specification sheet. <locking indication label> When blocking the EXH passage with an EXH block plate, an indication label for confirmation of the blocking position from outside is attached. (One label for each) pcs. in set Shut off label When ordering a block plate incorporated with the manifold no., a block indication label is attached to the manifold. EXH passage blocked SUP/EXH passage blocked --7

Plug-in Unit ase Mounted Series VQ000 ack pressure check valve assembly [-] VVQ000-8 pcs. in set When ordering assemblies incorporated with a manifold, add suffix - to the manifold no. It prevents cylinder malfunction caused by other valve exhaust. Insert it into R (EXH) port on the manifold side of a valve which is affected. It is effective when a single action cylinder is used or an exhaust center type solenoid valve is used. When a check valve for back pressure prevention is desired, and is to be installed only in certain manifold, write clearly the part no. and specify the number of by using the manifold specification sheet. (Precautions).The back pressure check valve assembly is assembly parts with a check valve structure. However, as slight air leakage is allowed for the back pressure, take care the exhaust air will not be throttled at the exhaust port..when a back pressure check valve is mounted, the effective area of the valve will decrease, by about 0%. VQC Name plate [-N] VVQ000-N-Station ( to Max. ) It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure. Suffix N to the manifold part no. P = When ordering assemblies incorporated with a manifold, add suffix -N to the manifold no. n Stations SQ VQ0 VQ VQ lanking plug (For One-touch fittings) 0 KQP-0 08 It is inserted into an unused cylinder port and SUP/EXH ports. Purchasing order is available in units of 0 pieces. Dimensions pplicable fittings size ød 8 Model KQP-0 KQP-0 KQP-08 L D 8 0. 9 8 0 VQZ VQD Port plug VVQ000-8 The plug is used to block the cylinder port when using a port valve as a port valve. When ordering a plug incorporated with a manifold, indicate CM for the port size in the manifold no., as well as, the mounting position and number of and cylinder port mounting positions, and, in the manifold specification sheet. DIN rail mounting bracket VVQ000-7 It is used for mounting a manifold on a DIN rail. The DIN rail mounted bracket is fixed to the manifold end plate. (The specification is the same as that for the option -D.) set of DIN rail mounting bracket is used for manifold ( DIN rail mounting brackets). When ordering assemblies incorporated with a manifold, add suffix -D to the manifold no. DIN rail clamp screwn uilt-in silencer, Direct exhaust [-S] This is a type with an exhaust port atop the manifold end plate. The built-in silencer exhibits an excellent noise suppression effect. (Silencing effect: 0 d) Exhaust port When ordering assemblies incorporated with a manifold, add suffix -S to the manifold no. large quantity of drainage generated in the air source results in exhaust of air together with drainage. For maintenance, refer to page --7. Silencer (For EXH port) This silencer is to be inserted into the EXH port (One-touch fittings) of the common exhaust type. Dimensions pplicable Effective area Noise Series fittings Model L D (mm ) reduction size ød (Cv factor) (d) VQ000 0 N00-KM0 9. 80.8 (.) 0 Elbow fitting assembly VVQ000-F-L (C, C, C8) It is used for piping that extends upward or downward from the manifold. When installing it in part of the manifold, specify the assembly no. and the mounting position and number of by using the manifold specification sheet. ~ = 8 ~ = matching fitting assembly VVQ000--C0 For driving a cylinder with a large bore, valves for two are operated to double the flow rate. This assembly for the cylinder port is used in that case. This assembly for the cylinder port is used in that case. The bore for the manifold no. is CM. Clearly indicate the station matching fitting assembly no., and specify the number of and positions in the manifold specification sheet. ~=.8 ~=. --7

ase Mounted Series VQ000 Manifold Double check block (Separated type) VQ000-FPG- - It is used on the outlet side piping to keep the cylinder in the intermediate position for a long time. Combining the double check block with a built-in pilot type double check valve and a position exhaust center solenoid valve will enable the cylinder to stop in the middle or maintain its position for a long time. The combination with a position single/double solenoid valve will prevent the dropping at the cylinder stroke end when the SUP residual pressure is released. Specifications Max. operating pressure Min. operating pressure mbient and fluid temp. Flow characteristics: C Max. operating frequency Dimensions Single unit (.) 0.8 MPa 0. MPa to 0 C.0 dm /(s bar) 80 c.p.m Note ) ased on JIS 87-98 (Supply pressure: 0. MPa) Manifold <Check valve operation principle> To CYL port Cylinder side (P) SUP side pressure (P) Dimensions How to Order Double check block VQ000-FPG 0 0 F IN side port size OUT side port size 0 0 C C8 80 ( ~ = 9.) 9. (For C, C8) ( ~ = 9.) (For C, C8) IN () (.) Rc /8 Rc / 7. 7. One-touch fitting for ø One-touch fitting for ø8 Manifold VVQ000-FPG 0 -Rc/8, /, C, C8 C: One-touch fitting assembly for ø C8: One-touch fitting assembly for ø8. -M mounting hole. (0) () 9. Residual pressure release manual override -Rc /8, /, C, C8 C: One-touch fitting assembly for ø C8: One-touch fitting assembly for ø8 7. (.) 7. Stations 0 0 0 C C8 station -M mounting hole <Ordering Example> VVQ000-FPG-0 manifold VQ000-FPG-CC-D: sets VQ000-FPG-C8C8-D: sets Double check block racket ssembly Part no. Tightening torque VQ000-FPG-F 0.8 to.0 N m --7 8 0. 0. 8 (9.) D side Stations n -Rc/8, /, C, C8 C: One-touch fitting assembly for ø C8: One-touch fitting assembly for ø8 Formula L = n + n: Station L n 7 8 9 0 L 8 90 78 00 88 0 7 L 7 87..7..7 00 0. 87.. 7.. 7 00 L 8. 98 8 7 8. 0.. 0. 7 98 8 7 8. 0. Rc /8 Rc / One-touch fitting for ø One-touch fitting for ø8 7 Nil D F N L L DIN rail clamp screw L P = Residual pressure release Manual override DIN rail mounting style (For manifold) With bracket Name plate When two or more symbols are specified, indicate them alphabetically. ir leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from stopping for a long time. Check the leakage using neutral household detergent, such as dish washing soap. lso check the cylinder s tube gasket, piston packing and rod packing for air leakage. Since One-touch fittings allow slight air leakage, screw piping (with M thread) is recommended when stopping the cylinder in the middle for a long time. Combining double check block with position closed center or pressure center solenoid valve will not work. IN IN <Example> Drop prevention IN Connection threads Rc /8 Rc / -Rc /8, /, C, C8 C: One-touch fitting assembly for ø C8: One-touch fitting assembly for ø8. 7. ( ~ = 9.) 80 ( ~ = 9.) (For C, C8) (For C, C8) U side 7.. Intermediate stops M fitting assembly is attached, not incorporated into the double check block. fter screwing in the M fittings, mount the assembly on the double check block. [Tightening torque: 0.8 to. N m] Proper tightening torque (N m) 7 to 9 to If the exhaust of the double check block is throttled too much, the cylinder may not operate properly and may not stop intermediately. Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.

Plug-in Unit ase Mounted Series VQ000/000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page -9-. Light/Surge Voltage Suppressor The lighting positions are concentrated on one side for both single solenoid type and double solenoid type. In the double solenoid type, side and side energization are indicated by two colors which match the colors of the manual overrides. (DWG shows a VQ000 case.) DC circuit diagram Single solenoid Light Surge absorption diode Stop diode side energization: light (orange) illuminates. side energization: light (green) illuminates. Warning Manual override: Green Manual override: Indicator light Single solenoid Double solenoid Indicator light : : Green Manual Override Double solenoid Stop diode Surge absorption diode Light With wrong wiring preventing ability (stop dieode). Equipped with a surge absorption (surge absorption diode) mechanism. Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Push type is standard. (Tool required) : Locking type (Tool required/manual) Push type (Tool required) ore ø. Push down on the manual override ore ø. button with a small screwdriver until it stops. Release the screwdriver and the manual override will return. How to Mount/Remove Solenoid Valve Clamp bracket Clamp bracket Removing. Loosen the clamp screw until it turns freely. (The screw is captive.). Lift the coil side of the valve body while pressing down slightly on the screw head and remove it from the clamp bracket. When the screw head cannot be pressed easily, gently press the area near the manual override of the valve. Mounting. Press down on the clamp screw. Clamp bracket opens. Diagonally insert the hook on the valve end plate side into clamp.. Press the valve body downward. (When the screw is released, it will be locked by clamp bracket.). Tighten the clamp screw. (Proper tightening torque: VQ000, 0. to 0. N m; VQ000, 0. to 0.7 N m.) Dust on the sealing surface of the gasket or solenoid valve can cause air leakage. The cylinder port fittings are a cassette for easy replacement. The fittings are blocked by a clip inserted from the top of manifold. Remove the clip with a screwdriver to remove fittings. For replacement, insert the fitting assembly until it strikes against the inside wall and then reinsert the clip to the specified position. Fittings assembly Clamp screw Replacement of Cylinder Port Fittings Clip VQC SQ VQ0 VQ VQ VQZ VQD Fittings assembly Locking type (Tool required) <> ore ø. Push down on the manual override ore ø. button with a small screwdriver or with your fingers until it stops. Turn clockwise by 90 to lock it. Turn it counterclockwise to release it. Locking type (Manual) <> Push down on the manual override button with a small screwdriver or with your fingers until it stops. Turn clockwise by 90 to lock it. Turn it counterclockwise to release it. Do not apply excessive torque when turning the locking type manual override. (0. N m or less) Clip pplicable tubing O.D. pplicable tubing ø. pplicable tubing ø pplicable tubing ø pplicable tubing ø8 M Fitting assembly part no. VQ000 VQ000 VVQ000-0-C VVQ000-0-C VVQ000-0-C VVQ000-0-M Refer to on pages --7 to --7 for other types of fittings. VVQ000--C VVQ000--C VVQ000--C8. Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result.. fter screwing in the fittings, mount the M fitting assembly on the manifold base. {Tightening torque: 0.8 to. N m}. Purchasing order is available in units of 0 pieces. --7

ase Mounted Series VQ000/000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page -9-. Mounting/Removing from the DIN Rail Removing. Loosen the clamp screw on side (a) of the end plate on both sides.. Lift side (a) of the manifold base and slide the end plate in the direction of () shown in the figure to remove. uilt-in Silencer Replacement Element silencer element is incorporated in the end plate on both sides of the dirty and choked element may reduce cylinder speed or cause malfunction. Clean or replace the dirty element. Element Part No. Type uilt-in silencer, direct exhaust The minimum order quantity is 0 pcs. Element part no. VQ000 VQ000 VVQ000-8- VVQ000-8- () Remove the cover from the top of the end plate and remove the old element with a screwdriver, etc. End plate Mounting. Hook side (b) of the manifold base on the DIN rail.. Press down side (a) and mount the end plate on the DIN rail. Tighten the clamp screw on side (a) of the end plate. The proper tightening torque for screws is 0. to 0. N m. (b) () Hook () (a) () (a) Enclosure IP Wires, cables, connectors, etc. used for models conforming to IP should also have enclosures equivalent to or of stricter than IP. How to Calculate the Flow Rate For obtaining the flow rate, refer to pages --8 to --. --7

ase Mounted Series VQ000/000 Special Wiring Specifications In the internal wiring of F, P, J, G, T and S, double wiring (connected to SOL. and SOL. ) is adopted for each station regardless of the valve and option types. Mixed single and double wiring is available as an option.. How to Order Indicate an option symbol -K, for the manifold no. and be sure to specify the mounting position and number of of the single and double wiring by means of the manifold specification sheet. Example) VVQ-08CFU-D K S Others, option symbols: to be indicated alphabetically.. Wiring specifications With the side solenoid of the st station as no. (meaning, to be connected to no. terminal), without making any terminals vacant. Negative Common Specifications Specify the valve model no. as shown below for negative COM specification. The manifold no. shown below is for the T and L s. For other s the standard manifold can be used. For negative COM S or G, please contact SMC. VQ00 N Negative common specifications How to order negative COM manifold T : VVQ 0 C T N N F D-sub connector (P). Max. number of The maximum number of depends upon the number of solenoids. ssuming one for a single and two for a double, determine the number of so that the total number is not more than the max. number given in the following table. Kit Type Max. points Kit Type Max. points F (D-sub connector) U F S P VQ000 VQ000 P Flat ribbon cable connector (P) U F S P P (Flat ribbon cable connector) U U U U U P S P S C P S P S J S P 0P P 0P 0P T (Terminal block) S (Serial transmission) S G (Flat ribbon cable with terminal block) 8 8 rows of rows of terminal blocks terminal blocks 0 J/G T Terminal block (VQ000, termials) J (Flat ribbon cable connector) T Terminal block (VQ000) 7 8 9 0 0 9 7 8 M G M (Circular connector) M COM L : VVQ Stations 0 Stations Cylinder port C L N Cylinder port Negative common specifications Electrical entry Cable length 0 With cable (0. m) With cable (. m) With cable ( m) Negative common specifications N --78

Plug-in Unit ase Mounted Series VQ000/000 External Pilot Specifications When the supply air pressure is lower than the required minimum operating pressure (0. to 0. MPa) for the solenoid valve (or when the valve is used for vacuum), specify an external pilot model. Order a manifold or valve by suffixing the external pilot specification, R. The X-port of the manifold base is equipped with One-touch fittings for external pilot. VQ000: C (One-touch fitting for ø) VQ000: C (One-touch fitting for ø) How to order manifold VVQ-08CFU-R S Others, option symbols: to be indicated alphabetically. How to order valves VQ00 R VQC SQ VQ0 VQ VQ VQZ VQD External pilot specifications Note ) When low wattage type is also desired, specify as RY. Note ) In this valve pilot exhaust is connected to the E passage of the manifold. Therefore, it is not possible to supply air from EXH port, nor vacuum from ports other than SUP port. Inch-size One-touch Fittings The valve with inch-size One-touch fittings is shown below. VVQ 0 N7 PS0 N Stations Cylinder port Symbol N N Kit/Electrical entry MT pplicable tubing O.D. (Inch) ø/8" ø/" ø/" ø/" (M 0-UNF thread) Mixed (), () VQ000 port VQ000 When inch-size fittings are selected for the cylinder port, use inch size fittings for both P and R port. N7 N9 NM (P), (R) port size VQ000 ø/" (N9) VQ000 ø/8" (N) --79

ase Mounted Series VQ000/000 DIN Rail Mounting Each manifold can be mounted on a DIN rail. Order it by indicating a DIN rail mounting option symbol, -D. In this case, a DIN rail which is approx. 0 mm longer than the manifold with the specified number of is attached. When DIN rail is unnecessary (DIN rail mounting brackets only are attached.) Indicate the option symbol, -DO, for the manifold no. Example) VVQ-08CFU-D0S Others, option symbols: to be indicated alphabetically. When using DIN rail longer than the manifold with specified number of Clearly indicate the necessary number of next to the option symbol -D for the manifold no. Example) VVQ-08CFU-D09S DIN rail for 9 Others, option symbols: to be indicated alphabetically. When changing the manifold style into a DIN rail mounting style. Order brackets for mounting a DIN rail. (Refer to on pages - -8 and --7.) No. VVQ000-7 (For VQ000) VVQ000-7 (For VQ000) pcs. per one set. When ordering DIN rail only DIN rail no.: XT00-DR- s for, specify the number from the DIN rail table. For L dimension, refer to the dimensions of each. (Pitch) L Dimension No. L dimension No. L dimension No. L dimension No. L dimension L =. x n + 0. 7 8 9 0. 8 0. 7 8. 98 0.. 7 8 9 0 8 0. 7 8. 98 0.. 8 0. 7 8 9 0 7 8. 98 0.. 8 0. 7 8. 7 8 9 0 98 0.. 8 0. 7 8. 98 0. --80