Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Similar documents
Wind Power Inverter WINDY BOY 5000A/6000A

System Monitoring SCHOOLMETERBOX AU

PV inverter SUNNY MINI CENTRAL 7000HV

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Wind Power Inverter WINDY BOY 1100LV

Charge controller SUNNY ISLAND CHARGER

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

PV inverter SUNNY BOY 2100TL

Operating parameters WINDY BOY

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Multi-Function Interface MULTI-FUNCTION RELAY

Wind Power Inverter WINDY BOY 3600TL / 5000TL

Oil-free piston compressors KK and piston vacuum pumps KV

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

PV Inverter SUNNY BOY 3300/3800

Wind Power Inverter WINDY BOY 1200/1700

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

Accessories for power generation plants in Italy SMA GRID GATE

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Swing Piston Compressors and Vacuum Pumps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

PV Inverter SUNNY BOY 3300/3800

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Operating Manual NA-BOX 12

MICRO-INVERTER OMNIKSOL M-300

Type 6213 EV, 6281 EV

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

Wilo-Control SC-Fire Jockey

Operating manual. Custom made gearboxes

Installation manual wall-mounted distributor

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Assembly and Maintenance Manual Type ASNU

Battery Charger. Series EASY Charger. User s manual

362 Clamp Meter. Users Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Armon Edero. User manual

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

DeltaSol AX * *

Battery Charger Series EASY Charger

Aurora Wind Interface Box

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

HOYMILES MICRO-IVERTER MI-250

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Operating Parameters SUNNY BOY / SUNNY MINI CENTRAL

Operating instructions

Micro Diaphragm Gas Sampling Pumps

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

INSTRUCTION & INSTALLATION

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

System Monitoring SUNNY SENSORBOX

ILED Aquarius Illuminated Windsock. User Manual

Exchange of rollers from the XTS-Mover

DC Master 24/ A

Installation manual portable distributors

KeContact P20. User manual

INSTALLATION MANUAL. Automatic Transfer Switch Battery Backup Distribution. FLEXIBLE STORAGE within Battery Backup Function

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Assembly and Maintenance Manual Type AS

Mod: KLD6-12/35XLAS-N

INSTRUCTIONS FOR USE. Rx Only

English. Instruction and operation manual S 212. Dew point sensor

Operating Instructions CYR52

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

RESOL SBS 1000 * * Connection Operation

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Solar Inverter SUNNY BOY 5000US / 6000US / 7000US

Sunny Tripower. Can do everything that we can

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

HST -LS Interlocking device (Translation of Original Manual)

Operating Instructions

Appendix: Safety and application notes for... 15

SUNNY BOY 2000HF / 2500HF / 3000HF

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

User Manual SMA FUEL SAVE CONTROLLER 2.0

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

SCOPELITE TIMING LIGHT OPERATING MANUAL

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Application cup for OptiFlex 2 GM03 manual powder gun

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

233 True-rms Remote Display Digital Multimeter Safety Information

Guidance to Installers of Viridian EV Charging Stations

HST-BL-2830MS & HST-BL-2830MS-USA

ILED Dorado. User Manual

Transcription:

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN

SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide............................... 5 1.1 Validity............................................ 5 1.2 Target Group....................................... 5 1.3 Additional Information................................ 5 1.4 Symbols Used....................................... 6 2 Safety.......................................... 7 2.1 Appropriate Usage................................... 7 2.2 Safety Precautions.................................... 8 2.3 Symbols on the Type Label............................. 8 3 Scope of Delivery................................. 9 4 Mounting the Windy Boy Protection Box............ 10 5 Electrical Connection............................. 13 5.1 Overview of the Connection Area...................... 13 5.1.1 Interior View................................................. 13 5.1.2 View from Below.............................................. 14 5.2 Grounding the Windy Boy Protection Box................ 14 5.3 Connecting the Small Wind Turbine System............... 15 5.4 Connecting the Wind Power Inverter.................... 16 5.5 Connecting the Load Resistor.......................... 17 6 Commissioning the Windy Boy Protection Box........ 18 7 Cleaning the Cooling Fins of the Windy Boy Protection Box........................ 19 8 Troubleshooting................................. 20 Installation Guide WBP-Box-IEN103320 3

Table of Contents SMA Solar Technology AG 9 Decommissioning................................ 21 9.1 Removing the Windy Boy Protection Box................. 21 9.2 Packaging the Windy Boy Protection Box................ 21 9.3 Storing the Windy Boy Protection Box................... 21 9.4 Disposing of the Windy Boy Protection Box............... 21 10 Technical Data.................................. 22 10.1 Windy Boy Protection Box 400........................ 22 10.2 Windy Boy Protection Box 500........................ 23 10.3 Windy Boy Protection Box 600........................ 24 11 Contact........................................ 25 4 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 1 Notes on this Guide 1 Notes on this Guide 1.1 Validity This guide applies to the following device types: WBP-Box 400-11 WBP-Box 500-11 WBP-Box 600-11 1.2 Target Group This guide is for qualified personnel. The tasks described in this guide may only be performed by qualified personnel. 1.3 Additional Information You will find further information on the Windy Boy Protection Box in the download area of www.sma.de/en. Installation Guide WBP-Box-IEN103320 5

1 Notes on this Guide SMA Solar Technology AG 1.4 Symbols Used The following types of safety warnings and general information are used in this guide: "DANGER" indicates a hazardous situation which, if not avoided, will result in death or serious injury. "WARNING" indicates a hazardous situation which, if not avoided, could result in death or serious injury. "CAUTION" indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. "NOTICE" indicates a situation that can result in property damage if not avoided. Important "Important" indicates important information. 6 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 2 Safety 2 Safety 2.1 Appropriate Usage The Windy Boy Protection Box converts the variable AC voltage of a small wind turbine system into DC voltage. The Windy Boy Protection Box sends the DC voltage to the wind power inverter. At the same time, the Windy Boy Protection Box protects the wind power inverter against overvoltage. Depending on the device type, the Windy Boy Protection Box restricts the DC voltage to 400 V, 500 V or 600 V (see section 10 Technical Data, page 22). The Windy Boy Protection Box has been designed to allow up to 3 wind power inverters to be connected. Various combinations with SMA wind power inverters are possible (see the Technical Information "Windy Boy Protection Box" at www.sma.de/en). The output voltage and output current of the small wind turbine system, among other factors, determine the systems for which the Windy Boy Protection Box is suitable. Observe all restrictions imposed by the manufacturer. Ensure that the permitted operating range of all components is maintained at all times. The Windy Boy Protection Box is only suitable for use with original SMA accessories or with accessories recommended by SMA Solar Technology AG. Do not use the Windy Boy Protection Box for purposes other than those described here. Modifications and the installation of components void the warranty claims and operation permit. This guide forms part of the Windy Boy Protection Box. Follow all tasks in this guide. Keep this guide in a convenient place for future reference. Principle of a small wind turbine system with Windy Boy Protection Box Installation Guide WBP-Box-IEN103320 7

2 Safety SMA Solar Technology AG 2.2 Safety Precautions Danger to life due to high voltages. All work on the Windy Boy Protection Box must be carried out exclusively by qualified personnel. 2.3 Symbols on the Type Label Symbol Designation Beware of dangerous electrical voltage. The Windy Boy Protection Box operates at high voltages. All work on the Windy Boy Protection Box must be carried out exclusively by qualified personnel. Beware of hot surface. The Windy Boy Protection Box can become hot during operation. Avoid contact during operation. Observe all documentation included with the Windy Boy Protection Box. The Windy Boy Protection Box must not be disposed of together with the household waste. For more information on disposal, see section 9.4 Disposing of the Windy Boy Protection Box, page 21. CE mark. The Windy Boy Protection Box complies with the requirements of the applicable EC guidelines. Direct Current (DC). Alternating Current (AC). 8 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 3 Scope of Delivery 3 Scope of Delivery Figure 1: Components included in delivery Position Quantity Designation A 1 Windy Boy Protection Box B 1 M25 cable gland C 4 M20 cable gland D 1 M12 cable gland E 3 Multiple seal inserts for M20 cable gland F 2 Sealing plugs for enclosure opening G 1 EC Declaration of Conformity H 1 Installation Guide Installation Guide WBP-Box-IEN103320 9

4 Mounting the Windy Boy Protection Box SMA Solar Technology AG 4 Mounting the Windy Boy Protection Box Requirements for the mounting location: Mount on a solid surface. The mounting surface and surrounding area are non-flammable. The mounting surface is suitable for the weight and dimensions of the Windy Boy Protection Box. The mounting location is accessible at all times. The ambient temperature is between 25 C and 65 C. The mounting location is not at risk of explosion. Mounting position: Figure 2: Permitted and prohibited mounting positions Minimum clearances: Figure 3: Obligatory clearances 10 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 4 Mounting the Windy Boy Protection Box Fixing points: Figure 4: Fixing point distances Destruction of the Windy Boy Protection Box due to overheating. If you mount the load resistor directly in line with the Windy Boy Protection Box on the rear of the wall, this will adversely affect the functionality of the Windy Boy Protection Box. Mount the load resistor in an offset position to the Windy Boy Protection Box on the rear of the wall. Installation Guide WBP-Box-IEN103320 11

4 Mounting the Windy Boy Protection Box SMA Solar Technology AG 1. Mark the position of the drill holes. Observe the fixing point distances when doing so. 2. Drill the holes according to the markings and insert wall anchors. 3. Insert 2 screws into the 2 upper holes. Leave the screws protruding out by 3 mm. 4. Hang the Windy Boy Protection Box onto the upper screws using the mounting links. 5. Secure the Windy Boy Protection Box using the lower fixing points. 6. Tighten both upper screws. 12 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 5 Electrical Connection 5 Electrical Connection 5.1 Overview of the Connection Area 5.1.1 Interior View Figure 5: Connection terminals Position A B C D E Designation Alternator connection terminal for small wind turbine system DC+ connection terminal for wind power inverter DC connection terminal for wind power inverter LR+ and LR connection terminals for load resistor PE connection terminal for grounding the Windy Boy Protection Box, the load resistor and its cable shield Installation Guide WBP-Box-IEN103320 13

5 Electrical Connection SMA Solar Technology AG 5.1.2 View from Below Figure 6: Enclosure openings for connections Position A B C D Designation Enclosure opening for small wind turbine system Enclosure openings for wind power inverter Enclosure opening for load resistor Enclosure opening for grounding the Windy Boy Protection Box, the load resistor and its cable shield 5.2 Grounding the Windy Boy Protection Box 1. Stop the small wind turbine system and secure against restart. 2. Disconnect the wind power inverter from voltage sources (see the manual for the wind power inverter). 3. Ensure that no voltage is present in the system. 4. Loosen the screws of the enclosure lid and carefully remove the lid. Disconnect the enclosure lid PE from the Windy Boy Protection Box when doing so. 5. Attach the M12 cable gland to the enclosure opening for grounding. 6. Unscrew the cable gland's lock nut and pass it over the PE of the Windy Boy Protection Box. 7. Pass the PE through the cable gland and connect to the PE connection terminal. 8. Tighten the lock nut firmly to the cable gland. 14 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 5 Electrical Connection 5.3 Connecting the Small Wind Turbine System Grounding the small wind turbine system: The small wind turbine system is not grounded through the Windy Boy Protection Box. You must ground the small wind turbine system by other means than the Windy Boy Protection Box. Observe all manufacturer instructions when doing so. Destruction of the Windy Boy Protection Box due to excessive power from the small wind turbine system. Observe the maximum power that can be connected (see section 10 Technical Data, page 22). If the power of the small wind turbine system exceeds the maximum power that can be connected to the Windy Boy Protection Box, use several Windy Boy Protection Boxes in the system. 1. If there are rectifiers and overvoltage protection between the small wind turbine system and the wind power inverter, remove the rectifiers and overvoltage protection. 2. Attach the M25 cable gland to the enclosure opening for the small wind turbine system. 3. Unscrew the cable gland's lock nut and pass it over the cable. 4. Pass L1, L2, and L3 of the small wind turbine system through the cable gland and connect to the Alternator connection terminal. 5. Tighten the lock nut firmly to the cable gland. Installation Guide WBP-Box-IEN103320 15

5 Electrical Connection SMA Solar Technology AG 5.4 Connecting the Wind Power Inverter Cable sizing: The cable has been sized for the maximum power of the wind power inverter. A stranded lead of type Silivolt-E 4 mm² or a comparable lead is used. Maximum length is 2 m. Maximum cross section is 6 mm². Connect each wind power inverter as per the following procedure. 1. Attach the M20 cable gland to the enclosure opening for the wind power inverter. 2. Unscrew the cable gland's lock nut and pass it over the cable. 3. Remove the seal from the cable gland. 4. Pass the multiple seal insert over DC+ and DC and press into the cable gland. 5. Connect DC+ to the DC+ connection terminal. 6. Connect DC to the DC connection terminal. 7. Tighten the lock nut firmly to the cable gland. 8. Close all enclosure openings that are not required with sealing plugs. 16 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 5 Electrical Connection 5.5 Connecting the Load Resistor Requirements: Load resistor never exceeds 54 Ω at the operating temperature. Load resistor never drops below 30 Ω when switched off. Load resistor has been designed for the maximum voltage of the Windy Boy Protection Box. The heat from the load resistor is permanently conducted away. Cable sizing: Cable of type "RADOX GKW - LW/S 3x2.5 mm²" or a comparable cable used. Maximum length is 3 m. Maximum cross section is 6 mm². 1. Measure the resistance of the load resistor. The resistance is above 30 Ω. The resistance is below 30 Ω? The load resistor is not suitable for connection to the Windy Boy Protection Box. Select another load resistor. Observe the requirements when doing so. 2. Attach the M20 cable gland to the enclosure opening for the load resistor. 3. Unscrew the cable gland's lock nut and pass it over the cable. 4. Connect PE to the PE connection terminal. 5. Connect the cable shield to the PE connection terminal. 6. Connect LR+ to the LR+ connection terminal. 7. Connect LR to the LR connection terminal. 8. Tighten the lock nut firmly to the cable gland. Installation Guide WBP-Box-IEN103320 17

6 Commissioning the Windy Boy Protection Box SMA Solar Technology AG 6 Commissioning the Windy Boy Protection Box Requirements: The small wind turbine system is correctly connected. The wind power inverter and load resistor are correctly connected. The Windy Boy Protection Box, load resistor and load resistor cable shield are grounded. The small wind turbine system is grounded according to the manufacturer specifications. All unused enclosure openings are closed with sealing plugs. 1. Mount the enclosure lid onto the enclosure. Connect the PE of the enclosure lid to the Windy Boy Protection Box when doing so. 2. Secure the enclosure lid with screws. 3. Commission the small wind turbine system. Observe all manufacturer specifications when doing so. 4. Commission the wind power inverter (see the manual for the wind power inverter). Green LED is glowing. Green LED and red LED are glowing? The Windy Boy Protection Box restricts overvoltage. As soon as the wind power inverter feeds into the public distribution grid, the red LED will go out. All LEDs are off? There is probably a fault. Eliminate the fault (see section 8 Troubleshooting, page 20). 18 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 7 Cleaning the Cooling Fins of the Windy Boy Protection Box 7 Cleaning the Cooling Fins of the Windy Boy Protection Box If the cooling fins of the Windy Boy Protection Box are very dirty, clean them with a soft brush. Installation Guide WBP-Box-IEN103320 19

8 Troubleshooting SMA Solar Technology AG 8 Troubleshooting Symptom Cause Corrective measures All LEDs are off. The small wind turbine system Commission the small wind turbine is stopped; there is no system. Observe all manufacturer voltage. specifications when doing so. All LEDs are off. There is no voltage. Check the connection of the small wind turbine system. See section 5.3 Connecting the Small Wind Turbine System, page 15 for this. If the Windy Boy Protection Box is permanently in this state, contact the SMA Serviceline. 20 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 9 Decommissioning 9 Decommissioning 9.1 Removing the Windy Boy Protection Box 1. Stop the small wind turbine system (see the manufacturer manual). 2. Decommission the wind power inverter (see the manual for the wind power inverter). 3. Loosen the screws of the enclosure lid and carefully remove the lid. Disconnect the enclosure lid PE from the Windy Boy Protection Box when doing so. 4. Disconnect the small wind turbine system from the Windy Boy Protection Box. 5. Disconnect the wind power inverter from the small wind turbine system (see the manual for the wind power inverter). 6. Disconnect the load resistor and the load resistor cable shield from the Windy Boy Protection Box. 7. Disconnect PE from the Windy Boy Protection Box. 8. Place the enclosure lid onto the enclosure and secure with screws. 9. Loosen all fixing screws. 10. Lift the Windy Boy Protection Box from the upper fixing screws. 9.2 Packaging the Windy Boy Protection Box Package the Windy Boy Protection Box in the original packaging if available. If the original packaging is not available, use a box that is suited to the weight and dimensions of the Windy Boy Protection Box. 9.3 Storing the Windy Boy Protection Box Requirements for the storage location: The storage location is dry. The ambient temperature is between 25 C and 65 C. 9.4 Disposing of the Windy Boy Protection Box Dispose of the Windy Boy Protection Box in accordance with the applicable disposal regulations for electronic waste. or Return the Windy Boy Protection Box to SMA Solar Technology AG with shipping paid by the sender. When doing so, label the packaging "ZUR ENTSORGUNG" ("FOR DISPOSAL"). Installation Guide WBP-Box-IEN103320 21

10 Technical Data SMA Solar Technology AG 10 Technical Data 10.1 Windy Boy Protection Box 400 Small wind turbine system connection Quantity Voltage Current Frequency Nominal power 1 x 3-phase 3 x 0 V 500 V 3 x 0 A 11.5 A 0 Hz 400 Hz 1 kw 3 kw Wind power inverter connection Maximum number 3 Voltage limitation 400 V Total power 3 kw Load resistor connection Quantity 1 Nominal voltage 400 V Continuous power 3 kw General data Width x height x depth 280 mm x 220 mm x 130 mm Weight 5 kg Rectifier Integrated Peak efficiency 99.95 % Operating temperature range 25 C 65 C Protection rating * IP54 Load loss at continuous power 15 W * According to IEC 60529 22 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 10 Technical Data 10.2 Windy Boy Protection Box 500 Small wind turbine system connection Quantity Voltage Current Frequency Nominal power 1 x 3-phase 3 x 0 V 500 V 3 x 0 A 11.5 A 0 Hz 400 Hz 3 kw 5 kw Wind power inverter connection Maximum number 1 Voltage limitation 500 V Voltage limitation with connection to a 550 V Windy Boy 5000TL Total power 5 kw Load resistor connection Quantity 1 Nominal voltage 500 V Continuous power 5 kw General data Width x height x depth 280 mm x 220 mm x 130 mm Weight 5 kg Rectifier Integrated Peak efficiency 99.95 % Operating temperature range 25 C 65 C Protection rating * IP54 Load loss at continuous power 20 W * According to IEC 60529 Installation Guide WBP-Box-IEN103320 23

10 Technical Data SMA Solar Technology AG 10.3 Windy Boy Protection Box 600 Small wind turbine system connection Quantity Voltage Current Frequency Nominal power 1 x 3-phase 3 x 0 V 500 V 3 x 0 A 11.5 A 0 Hz 400 Hz 2 kw 7 kw Wind power inverter connection Maximum number 2 Voltage limitation 600 V Total power 7 kw Load resistor connection Quantity 1 Nominal voltage 600 V Continuous power 7 kw General data Width x height x depth 280 mm x 220 mm x 130 mm Weight 5 kg Rectifier Integrated Peak efficiency 99.95 % Operating temperature range 25 C 65 C Protection rating * IP54 Load loss at continuous power 30 W * According to IEC 60529 24 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG 11 Contact 11 Contact If you have technical problems concerning our products, contact the SMA Serviceline. We require the following information in order to provide you with the necessary assistance: Device type (see "Type/Model" on the type label) Serial number (see "SerialNo." on the type label) Type of connected small wind turbine system Type and number of connected wind power inverters Technical data of the connected load resistor SMA Solar Technology AG Sonnenallee 1 34266 Niestetal, Germany www.sma.de SMA Serviceline Inverters: +49 561 9522 1499 Communication: +49 561 9522 2499 Fax: +49 561 9522 4699 E-Mail: Serviceline@SMA.de Installation Guide WBP-Box-IEN103320 25

Notes SMA Solar Technology AG 26 WBP-Box-IEN103320 Installation Guide

SMA Solar Technology AG Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission. Exclusion of liability The general terms and conditions of delivery of SMA Solar Technology AG shall apply. The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.sma.de or from the usual sales channels. Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: Damages during transportation Improper or inappropriate use of the product Operating the product in an unintended environment Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location Ignoring safety warnings and instructions contained in all documents relevant to the product Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond statutory limit values In case of unforeseen calamity or force majeure The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions: SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Technology AG. This also applies to the provision or non-provision of support activities. Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements of the manufacturer. SMA Factory Warranty The current guarantee conditions come enclosed with your device. These are also available online at www.sma.de and can be downloaded or are available on paper from the usual sales channels if required. Trademarks All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under license. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de E-Mail: info@sma.de 2004 to 2010 SMA Solar Technology AG. All rights reserved Installation Guide WBP-Box-IEN103320 27