Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage

Similar documents
PETROLEUM STORAGE & HANDLING Adam Speir, Public Service Representative Biological and Agricultural Engineering PRE-ASSESSMENT: Storage & Handling

Background. AEM Tier 2 Worksheet Petroleum and Oil Product Storage. Glossary. Agricultural Water Quality Principle:

HOW TO PROTECT YOUR WATER FROM SPILLED FUEL

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

Fuel Storage Dec 2016

PETROLEUM STORAGE & HANDLING Mark Risse, Public Service Assistant Biological & Agricultural Engineering

Underground Storage Tank Guidance for Commercial Building Inspectors

LEAKING UNDERGROUND STORAGE TANKS

CONTENTS. Foreword...iii. 1. Introduction...1

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

Petroleum Storage Tank Release Detection and Inventory Control

1) Activity Description: Management of Petroleum Storage Tanks and Containers

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

NYSDEC PBS REGULATIONS Heating Oil Tanks

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

UST Compliance Assistance Handbook

B2. Fueling Operations

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

NCDEQ Underground Storage Tank Section

Notification for Underground Storage Tanks

New UST Installation Inspection Checklist

Cathodic Protection for AST s. Why is Cathodic Protection Important?

Environment Canada (EC) Storage Tank System Identification Form

Arizona Tank Closure, Assessment and Response

Above Ground Oil Tanks

NYSDEC CBS Compliance Requirements

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

Overview of an Underground Storage Tank Inspection

Leak Detection for Petroleum UST and Piping

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

Management of Underground Storage Tanks

Fuel Systems GASOLINE FUEL SYSTEMS

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

Spill Prevention, Control, and Countermeasure. Training Module

ECM environmental compliance monitoring, inc. 1

Fire & Rescue District

(Please type or use black ink)

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

Guidelines For the MITIGATION OF ACCIDENTAL DISCHARGES OF MOTOR VEHICLE FLUIDS (NON-CARGO) APPROVED 6/25/04

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

Management of Underground Storage Tanks

7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section

Safe Operating Procedure

County of Fresno DEPARTMENT OF PUBLIC HEALTH

401 KAR 42:020. UST systems: design, construction, installation, and registration.

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

Florida State University Coastal & Marine Laboratory Fuel Spill Contingency Plan

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

5. What are other common issues with on farm fuel storage?

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

NYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION CLASS C OPERATOR TRAINING

Mark S. Morgan, Regulatory Counsel

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

Storage Tank Risk Management Solutions Leak

Removal of Underground Storage Tanks (UST) Encountered during Construction

PUBLIC WORKS AND SERVICES PETROLEUM PRODUCTS DIVISION STANDARD DETAILED DRAWINGS FOR NORTHERN FUEL STORAGE AND DISTRIBUTION FACILITIES

BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION

Syracuse University Petroleum Bulk Storage Tank Program Manual

UNDERGROUND STORAGE TANK (UST) INSTALLATION & MAINTENANCE

Safe Operating Procedure

How to Comply with Florida DEP AST Rules and Avoid Petroleum Discharges to the Environment

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

P.O. Box 435 Saratoga Springs, NY 12866

How to Stop Spill Buckets from Draining You Dry

TGL-28-R1-04. Gasoline Stations

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

OWS OPERATIONS & MAINTENANCE

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

Environmental Controls in ROWs and Available Cleanup Funding Programs

Vehicle and Equipment Fueling

ANNUAL UST SYSTEM INSPECTION CHECKLIST

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY STATISTICAL INVENTORY RECONCILIATION (SIR) GUIDANCE DOCUMENT

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

South Tacoma Groundwater Protection District Spill Prevention and Response Plan

Regulatory Changes: Chapter 245. AST s

Test Stations and Pipe-to-Soil Potential Measurements

Coordination with the Spill Prevention, Control, and Countermeasures Plan

NISTM 2015 New England UST and Shop-Fab Storage Tank Conference

LEAK DETECTION INTERSTITIAL MONITORING

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Ohio s Used Oil Regulations for Generators

THE CORPORATION OF THE DISTRICT OF SAANICH BYLAW NO OIL BURNING EQUIPMENT AND FLAMMABLE LIQUID AND COMBUSTIBLE LIQUID FUEL TANK BYLAW

Transcription:

Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage

N E W M E X I C O FARM A SYST Farmstead Assessment System Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage 1. Storage tank location The most important aspect of your liquid petroleum storage tank location is how close it is to your drinking water well. New Mexico Water Supply Regulations Section 110:C.2 requires that petroleum storage tanks be located at least 100 feet from a drinking water well. Minimum separation distances regulate only new well installation. Existing wells are required by law only to meet separation requirements in effect at the time of well construc- tion. Make every effort, however, to exceed old regulations, and strive to meet current regulations whenever possible. Even though diesel fuel and fuel oil are more dense than gasoline and move more slowly through the soil, they, too, will eventually reach groundwater. Every site has unique geologic and hydrologic conditions that can affect groundwater movement. How quickly the petroleum product reaches groundwater will also depend upon local soils. The more porous the soil (sands and gravel, for example), the faster the rate of downward movement to groundwater.you may choose to locate a new tank more than 100 feet away from your well, to provide reasonable assurance that subsurface flow or seepage of contaminated groundwater will not reach your well. If possible, the tank should also be located downslope from the well. Figure 1 illustrates petroleum product seepage into soils. If you have an above-ground tank, follow existing regulations for underground storage tanks as a guide. To protect against explosion and fire, do not locate tanks (especially aboveground tanks) closer than 25 feet to existing buildings. Previous practices for siting aboveground storage tanks were concerned more with the explosion potential of tanks than the groundwater pollution potential. Contemporary petroleum storage practices also protect groundwater. For glossary, see Worksheet Figure 1: Petroleum product seepage into soils. Source: Underground Tank Corrective Action #4. Technologies, EPA/625/6-87-015, January 1987. COOPERATIVE EXTENSION SERVICE NEW MEXICO STATE UNIVERSITY COLLEGE OF AGRICULTURE AND HOME ECONOMICS F4.1

New storage tank location Along with maintaining adequate distance from your drinking water well, choose a location for a new tank based on the following considerations: Soil characteristics. Highly corrosive clays, wet soils, cinders and acid (low ph) soils can significantly speed up the rate of corrosion of underground metal tanks and piping. Using clean backfill during installation can decrease the negative effects of surrounding soils. Soil stability. Assess the ability of the underlying soil to support both underground and above-ground tanks. For special tank locations, such as hillsides, be sure to properly anchor and hold tanks in place. Be sure that pipes cannot twist or break if the tank is bumped or disturbed. Regardless of soil conditions, it is good management to locate aboveground tanks over an impermeable liner made of concrete or one of the newer synthetic fabrics. Build a collection device for spills. 2. Tank design and installation Current and previous land use. Sites that contain abandoned pipes and tanks, agricultural drainage tiles or waste materials pose special installation problems. Any metal already in the ground at your chosen site will increase corrosion rates for the new tank. Traffic. Assess traffic patterns around the tank. Determine whether the location of the tank or dispenser will block movement of farm vehicles during refueling or cause special problems if any work needs to be done on the tank. Protect piping from collisions with farm and fuel vehicles. Depth to groundwater. Floodways or areas where the water table is close to the surface are poor locations for storage tanks. Tanks placed in such areas require special installation. To reduce pollution potential, an above-ground tank may be preferable to an underground tank. Whenever you install a fuel storage tank, carefully follow the manufacturer s recommended practices for installation. Proper installation is one sure way to minimize the leaking potential of the tank or the piping connected to it. Even scratches in a metal tank caused by careless installation can increase corrosion and tank deterioration. Farm tanks with more than 1100 gallons capacity must be registered with the New Mexico Environment Department Underground Storage Tank Bureau (NMED-USTB). It is not recommended to reuse an underground tank above ground. Underground tanks All new underground petroleum storage tanks and related piping must be constructed of non-metallic materials such as fiberglass, or have corrosion protection. Methods of corrosion protection include exterior coating, interior liners and sacrificial anodes. A sacrificial anode is a special material connected to the tank with a greater tendency to corrode than the tank material. The anode will typically protect the tank for up to 30 years. Interior liners are made of noncorrosive synthetic materials and can also be effective in protecting metal tanks. F4.2

New Mexico regulations require that all new farm underground tanks have spill and overfill protection. Spill protection typically consists of a catch basin for collecting spills when the tank is filled. Overfill protection is a warning or prevention of an overfill such as an automatic shutoff or buzzer. Spill and overfill protection are important; they can prevent a number of small releases over a long period of time from polluting the groundwater. Above-ground tanks For above-ground tank installation attempt to reduce the potential for both pollution and fire. Good management practices include 1) enclosing the tank within a secure 6-foot fence or well-ventilated building constructed of noncombustible material; and 2) constructing a fire wall between the fuel dispensing area and the tank. 3. Monitoring To decrease pollution potential, place farm tanks within a secondary containment structure consisting of a dike and a pad. All piping should be above ground within the dike or may go over the dike wall, but it must be placed below ground within 10 feet of the dike wall. Above-ground piping should be made of steel and coated to prohibit corrosion. Any below-ground piping may be either steel or fiberglass, but steel must be coated and cathodically protected. Regulations for new underground farm tanks require that all tanks, greater than 1100 gallons capacity, have a method of detecting leaks. Test procedures will depend upon the age and condition of the tank. Contact NMED for requirements. Since cleanup of gasoline leaks is always costly and often not totally effective, it is important to constantly monitor underground tanks containing petroleum products. If you already have a petroleum storage tank on your farm, be especially aware of the age of your tank as well as the need to establish a leak-detection program. Figure 2 shows how groundwater can be contaminated by underground tanks. Figure 2: Contamination of groundwater due to improper fuel storage and transfer. Source: Handling and Underground Storage of Fuels, Cooperative Extension Service, Michigan State University, Extension Publication WQ01. Reprinted February 1986. F4.3

4. Tank closure Since most tanks used on farmsteads are bare steel, tank corrosion or piping problems will cause leaks sooner or later. If your tank is more than 20 years old, or if you don t know its age, make a special effort immediately to determine whether leaks exist. You can test tank integrity by such methods as precision testing/tightness testing and volumetric analysis. State regulations allow some other testing methods. You can request a list of approved tank-testing methods and suppliers phone numbers from the NMED-USTB at (505) 827-0216. Even when a tank has been tested and proven tight, existing regulations and good practice require that you have a method for regularly detecting leaks. You should install such internal or external monitoring methods as groundwater monitoring wells, vapor monitoring, automatic tank gauging or other approved methods. Measuring tank inventories is an inexpensive and easy way to help detect leaks. Leakage is apparent when there is any decrease in level over time without any withdrawal of fuel or an increase in water in the tank. While inventory measurement will not detect very small leaks, it will at least provide a warning that further investigation may be necessary. If you use a measuring stick to measure tank liquid level, be sure that the stick does not puncture or damage the bottom of the tank. The closer the tank is to the farmstead s drinking water well, the more important it is to ensure that an adequate leak-detection system is in place. Leaks and spills If you find a leak or spill from any tank whether it be above or below ground, or even a vehicle-mounted tank notify the Remedial Action Staff at (505)827-0188. Take whatever actions are necessary to remedy the problem, according to recommendations you receive when you report the spill or leak. The New Mexico Environment Department administers the federal Leaking Underground Storage Tank Trust Fund, which may be used in cleaning up a problem for federally regulated tanks or home heating fuel tanks. For more information about the fund, call NMED- USTB at (505) 827-0079. Tanks no longer in use can cause problems for owners and operators many years later. They will continue to corrode and, if they still contain gas or oil, will likely contaminate groundwater. Try to determine the location of any unused tanks on your property. Also, try to find out whether the tanks still hold product or have holes. These tanks must be pulled from the ground and disposed of in a landfill or at a scrap dealer. State law does not require licensed contractors to pull a tank. However, precautions must be taken to prevent explosion or other problems. Deaths have occurred due to improper closure. Only experienced persons should attempt tank closure. F4.4

If you are concerned that your unused tank has been leaking, consult an environmental engineer or NMED-USTB investigator to determine if further investigation is warranted. If there is groundwater pollution in your area, your neighbors will be sure to suspect the tank as its cause. NMED-USTB also has regulatory authority to investigate potential pollution situations and recover costs from responsible parties. You should document steps you take to legally close your tank including that you notify the NMED-USTB that the tank has been closed so that you are protected from legal action in the event of groundwater problems. Written by Pat Walsh. Revised by Craig Runyan, Plant Sciences Department, New Mexico State University Cooperative Extension Service. F4.5