Meter Mounting Equipment Wisconsin Area

Similar documents
Wisconsin Area Catalog

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Meter Mounting Equipment DTE Energy Area

Meter Mounting Equipment. Northern Indiana Public Service Co.

MEG Approval Meter Equipment Group

Indiana Meter Mounting Equipment

REC Municipal Meter Mounting Equipment

Duke/MEG Approval Meter Equipment Group

ComEd Service Area Meter Mounting Equipment

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment Florida Area Catalog

Ohio Meter Mounting Equipment

Meter Mounting Equipment Commonwealth Edison

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Louisiana/Mississippi. Area Catalog

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

Meter Mounting Equipment

Louisiana & Mississippi Area Catalog

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Tennessee Area Meter Mounting Equipment

Ameren Service Area Product Catalog

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

Recreational Vehicle Park Electrical Products & Accessories

Ameren Service Area Product Catalog

Instrument Rated Metering Equipment

PSE&G Long Island Meter Mounting Equipment

Upstate New York Meter Mounting Equipment

New York City Apartment Metering Meter Sockets / Load Centers

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

Consolidated Edison Orange & Rockland Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment

5.2. Power Pedestals. Contents Description

6.2. Power Pedestals. Contents

Multiple Metering, Horizontal Gang - Non Lever Bypass

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Contents. Volume 1 Residential and Light Commercial CA E December

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Equipment. Metering. Metering Equipment 1. Contents

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

(CT, NH, ME, RI, VT, MA)

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Selection and Application Guide For use in New England EQUIPMENT

Equipment. Metering. Metering Equipment 1. Contents

AMENDMENT ELECTRIC SERVICE MANUAL 2014

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Modular Metering Application Guide

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

Multiple Metering, Vertical Gang

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units

Design Standard. Purpose: Design Standard:

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

MP Meter-Pak Meter Centers

10 Commercial, Industrial, Agricultural Services

Group Meter Main - Without Bypass

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT

Lighting and Power Distribution Panelboards

Customer Requirements Meter Socket Configurations

Section 6 Electric Metering: Residential

WPS SERVICE MANUAL. Section Amp and Smaller - Common

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

6.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

SPEEDFAX TM 2011 Meter Centers Contents

Meter Centers Meter Mounting Devices

Indianapolis Power & Light Company

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Quik-Spec Electrical Gear

Service Entrance Methods

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

CT Metering. CT Metering. Meter Mounting Equipment

Contents. 4 Loadcentres

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

10. METERING General Requirements

Volume 1 Residential and Light Commercial CA E December

Modular Metering. Canadian Version

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Selection and application guide

CON EDISON EQUIPMENT

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

2017 PNM Approved Meter Equipment

Bussmann series Quik-Spec Coordination Panelboard

Approved Contractor Construction e-guide Residential Commercial

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Modular Metering Construction Details

Transcription:

Meter Mounting Equipment Wisconsin Area

MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank: Quality Metering Products for 80 Years Milbank Manufacturing Company was established in 97 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 9 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank s employee base of over,000 workers, along with our five manufacturing facilities comprising almost 0,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 0,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for more than 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE!

TABLE OF CONTENTS LOGIC......................................................................... DISCONNECTS AIR CONDITIONER DISCONNECTS................................................................... AIR CONDITIONER DISCONNECT WITH GFCI RECEPTACLE.............................................. HOT TUB DISCONNECT............................................................................. SINGLE POSITION AMP, & TERMINAL, RINGLESS................................................................. 7 AMP, 7 TERMINAL, RINGLESS, LEVER BYPASS..................................................... 8 00 AMP, & TERMINAL, RINGLESS................................................................. 9 00 AMP, & 7 TERMINAL, RINGLESS, HEAVY LEVER BYPASS.......................................... 0 00 AMP, 7 TERMINAL, RINGLESS, LEVER BYPASS.................................................... 0 AMP,, & 7 TERMINAL, RINGLESS, LEVER BYPASS............................................... TABLE OF CONTENTS MULTIPLE POSITION 00 AMP / POSITION, HORIZONTAL GANG SOCKETS, & TERMINAL................................. - 00 AMP / POSITION, VERTICAL GANG SOCKETS, TERMINAL.......................................... 00 AMP / POSITION, HORIZONTAL GANG SOCKETS, & TERMINAL.................................... 00 AMP / POSITION, HORIZONTAL GANG SOCKETS, TERMINAL, LEVER BYPASS......................... 7 00 AMP / POSITION, HORIZONTAL GANG SOCKETS, 7 TERMINAL, LEVER BYPASS........................ 8 CONDOMINIUM METERING BANKS (MULTIPLE POSITION) AMP / POSITION.............................................................................. 9 00 AMP / POSITION.............................................................................. 9 DIMENSIONAL INFORMATION...................................................................... 0 METER MAINS 00 AMP, & TERMINAL, RINGLESS................................................................ 00 AMP, & TERMINAL, RINGLESS................................................................ 00 AMP, & TERMINAL WITH LOAD CENTER, RINGLESS............................................. SERVICE PEDESTALS 0 AMP, TERMINAL WITH BREAKER PROVISION, RINGLESS.......................................... 0 AMP, & TERMINAL, WITHOUT BREAKER PROVISION, RINGLESS................................... 00 / 00 AMP, TERMINAL, METER MAIN PEDESTAL.................................................. TEMP-TO-FINAL SERVICE PEDESTAL AND UNIVERSAL ALL-IN-ONE PEDESTAL............................ 00/00 AMP, & TERMINAL, RINGLESS............................................................ JOINT USE TERMINATION CABINET................................................................. 00/00 AMP, RINGLESS METERED PEDESTAL........................................................ 7 00 AMP, & 7 TERMINAL, RINGLESS, HEAVY DUTY LEVER BYPASS..................................... 8 00 AMP, TERMINAL RINGLESS MOBILE HOME PEDESTAL............................................ 9 C.T. RATED (WITH TEST SWITCH PROVISION) 0 AMP, SINGLE POSITION, RINGLESS............................................................... 0 0 AMP, DOUBLE POSITION, RING TYPE............................................................. 0 MISCELLANEOUS POLYPHASE ENCLOSURES, SINGLE & MULTIPLE POSITIONS........................................... K-TYPE, & 7 TERMINAL METER SOCKETS........................................................ - COMMERCIAL METER PEDESTALS............................................................... -7 ACCESSORIES................................................................................ 8-9 CONDUIT AND AMPACITY INFORMATION............................................................. 0 SHORT CIRCUIT CURRENT RATING CHART.......................................................... ENERGIZATION OF ELECTRICAL EQUIPMENT......................................................... MATERIALS & FINISHES........................................................................... METER FORMS (WIRING DIAGRAMS)................................................................ APPROVING UTILITIES.......................................................................... -7 INDEX.......................................................................................... 8 OTHER MILBANK PRODUCTS....................................................................... 9

LOGIC LOGIC

0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS DISCONNECTS AMP U80 U80 Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article 0- in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TYPE MAX H.P. WT. @ # 0 NON FUSIBLE U80 0. 0 FUSIBLE U8. 0 FUSIBLE U80 0. TECHNICAL INFORMATION LINE & LOAD WIRE RANGE CU AL CU/AL #-# AWG #-# AWG #-# AWG U8 PROFILE GROUND WIRE RANGE WIRE RATING D" W" H" CU C AL C #-# AWG #- AWG -/ 7-/ 0 /7 0 /7 #-# AWG #- AWG -/8 7 0 /7 0 #-# AWG #- AWG 9-/ 0 /7 0 /7 0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS UL Listed as Enclosed Pullout Switch, 0 VAC Type R Rainproof One-inch concentric knockouts Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

AC DISCONNECT / SPA BOX DISCONNECTS AC DISCONNECT / SPA BOX Combination AC Disconnect / 0 Amp GFCI Receptacle Together in Box U8-0GWR 0 amp, Non-Fused AC Disconnect Duplex 0 amp GFCI Receptacle WR-TR Type R Enclosure with In-Use Cover Meets NEC #0. Requirements* UL Listed as Power Outlet Type R Enclosure In-Use Cover** Duplex Ground Connector Concentric Knockouts AC DISCONNECT, 0 Volt 0 amp, Non-Fused GFCI RECEPTACLE 0 amp Reset/Test Button Weather Resistant/Tamper Resistant Meets NEC #0.8 Requirements* * NEC #0. Heating, Air-Conditioning and Refrigeration Equipment Outlet....The receptacle shall be located on the same level and within 7. m ( ft.) of the heating, air-conditioning and refrigeration equipment. * NEC #0.8 Ground- Fault Circuit Interruptor protection for personnel. * NEC #0.8 receptacles in damp or wet locations. AMP TYPE MAX H.P. WT. @ # 0 NONFUSIBLE U8-0GWR 0 LINE & LOAD CONNECTOR WIRE RANGE CU AL CU/AL #-# AWG #-# AWG GROUND CONNECTOR WIRE RANGE WIRE RATING #- AWG D W H CU C AL C.8. 7. 0 /7 0 /7 To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U8-0GWR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). Units supplied with WRTR receptacle. *Reprinted with permission from NFPA 70-00, National Electrical Code, Copyright 00, National Fire Protection Association, Quincy, MA 09. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R U88-O-0GB Spa Box with GFCI Protection 0 Volt ground fault protection UL listed, Type R rainproof Milbank reliability Easy installation pole, 0 amp GFCI breaker protection Compact size: 8-/ H x 7-/ W x -/ D or wire installation, 0 / 0 VAC Standard package of extra one-pole breaker spaces 00 amp overall rating Sub Panel Breaker Enclosure Use as a 00 amp, circuit sub pane enclosure U88-O has provision for () -pole or () -pole small frame breakers AMP 0 0 TYPE WT. @ # BREAKER PROVISION U88-O 7 BREAKER BREAKER U88-O-0GB U88-O-0GB 8 8 LINE & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE CU AL CU/AL #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 D W H 7 8 7 8 7 8

AMP & TERMINAL RINGLESS 00 VAC 7 TERMS. SERVICE AMP U787-RL-TG-KK CONNECTORS CU / AL BY- PASS AMP & TERMINAL* RINGLESS W D W H OH U787-RL-TG-KK* H.O. #-/0 HORN 8 SINGLE POSITION AMP & TERMINAL RINGLESS 00 VAC S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The -KK, horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. *FIFTH TERMINAL: For field mounted fifth terminal, order catalog number T8K (must be bolted in). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 AMP 7 TERMINAL LEVER BYPASS NON JAW CLAMPING RINGLESS 00 VAC SINGLE POSITION AMP 7 TERMINAL LEVER BYPASS NON JAW CLAMPING RINGLESS 00 VAC 77 U77-RL 90 U90-RXL AMP 7 TERMINAL RINGLESS W SERVICE AMP CONNECTORS CU/AL BY- PASS D W H OH OH/UG U77-RL H.O. #-/0 LEVER 7 8 0 8, U90-RXL C.P. #-/0 LEVER 7 8 9, S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever operates bypass only; does not provide clamping action on meter spades. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8

00 AMP & TERMINAL RINGLESS 00 VAC 9 U-RXL 77 U77-XL-TG-KK SINGLE POSITION TERMS. AMP SERVICE 00 00 00 00 00 UG OH/UG OH/UG UG UG U80-XL U80-O-TG-KK* U80-XL** U80-XL-T9 ** U80-O** U80-O-T9 ** 80 CONNECTORS CU/AL LINE LOAD BY- PASS BLANK #-0 #-0 HORN C.P. #-0 #-0 LEVER C.P. #-0 #-0 LEVER BLANK #-0 #-0 LEVER BLANK #-0 #-0 LEVER U80-O-TG-KK 00 AMP & TERMINAL RINGLESS W D W H 7 8 7 8 7 8 7 8 9 9 9 9 00 OH U77-XL-TG-KK** C.P. #-0 #-0 HORN 8 00 OH U-RXL** C.P. #-0 #-0 LEVER 7 8 9,, 80,,,,, 00 AMP & TERMINAL RINGLESS 00 VAC S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: U: Lever operates bypass device only; does not provide clamping action on meter spades. On the U77 & U80, the -KK, horn type bypass permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. The U80 is a heavy duty lever bypass and the lever supplies clamping action on jaws. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K8 for the U, U80-XL & U80-O. For field mounted fifth terminal for the U77 & U80, order catalog number KT to fit into square opening at the 9 oʼclock position. FACTORY-INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 oʼclock position for use on Alliant Energy lines when a fifth terminal is required. * SHORT CIRCUIT CURRENT RATING: 0,000 RMS sym amps 00 VAC ** SHORT CIRCUIT CURRENT RATING: See chart on page Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9

0 00 AMP & 7 TERMINAL LEVER BYPASS HEAVY DUTY RINGLESS 00 VAC 00 AMP & 7 TERMINAL LEVER BYPASS HEAVY DUTY RINGLESS 00 VAC SINGLE POSITION SERVICE OH UG # OF TERMS U90-RL (Shown w/o Hub) U90-DL ** 00 AMP TERMINAL RINGLESS or W 00 AMP 7 TERMINAL RINGLESS W CONNECTORS CU/AL BY- PASS #-0 LEVER D W H 7 8 0 8, U9-O ** BLANK #-0 LEVER 7 8 9 OH/UG U8-RXL** C.P. #-0 LEVER 7 8 9 OH 7 U9700-RRL** H.O. #-0 LEVER 7 8 0 8, OH/UG 7 U970-RXL** C.P. #-0 LEVER 7 8 9 Supplied with sliding link neutral disconnect. Grounded B Phase (may be field isolated). WARNING LABEL: A warning label is placed on the upper center of the shield to indicate proper use of the link for various circuits. ISOLATED NEUTRAL: For field installed insulated neutral in the U970 wide units, order as extra catalog number K07. S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever operates bypass device and provides clamping action on meter spades. CONNECTORS: Supplied with internal hex connectors. Extruded aluminum connectors are tin plated. ** SHORT CIRCUIT CURRENT RATING: See chart on page 90 9700 9 8 970 U970-RXL,,, Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 0

00 AMP 7 TERMINAL LEVER BYPASS RINGLESS 00 VAC 7 SINGLE POSITION SERV- ICE OH OH/UG AMP 00 U7-RL U7-RL* H.O. CONNECTORS LINE LOAD 7 70 BY- PASS #-0 #-0 LEVER D W H 7 8 0 8 U7-XL, 00 U7-XL * C.P. #-0 #-0 LEVER 7 8 9 OH/UG 00 U70-XL ** C.P. #-0 00 AMP 7 TERMINAL RINGLESS W #-0 LEVER 7 8 9 S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: For units U7 and U7 the lever operates bypass only; does not provide clamping action on meter spades. For the U70-XL the lever operates bypass, and provides clamping action on meter spades. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. U70 is supplied with external hex connectors. U7 and U7 are supplied with internal hex connectors. ISOLATED NEUTRAL: For field installed isolated neutral order as extra catalog number K07. * SHORT CIRCUIT CURRENT RATING: 0,000 RMS sym amps 00 VAC ** SHORT CIRCUIT CURRENT RATING: See chart on page,, 00 AMP 7 TERMINAL LEVER BYPASS RINGLESS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

0 AMP, & 7 TERMINAL LEVER BYPASS HEAVY DUTY RINGLESS 00 VAC 0 AMP, & 7 TERMINAL LEVER BYPASS HEAVY DUTY RINGLESS 00 VAC SINGLE POSITION U-X-QG TERMS. AMPS 7 7 0 0 0 0 0 0 0 0 U000-O-KL-KL SERVICE 0 AMP CONTINUOUS*, & 7 TERMINAL HEAVY DUTY RINGLESS 00 VAC CONNECTORS CU/AL U-X-QG** U000-O-KL** U000-O-KL-KL** U000-O-T9-KL-KL ** U779-RRL-K** U779-RRL-T9-K ** U9-X-K7** U0-X-K7** OH/UG UG UG UG OH OH OH/UG UG C.P. BLANK BLANK BLANK H.O. H.O. C.P. C.P. LINE 779 8 x STUD #-00 () /0-0 () #-00 () /0-0 () #-00 () /0-0 () #-00 () /0-0 () #-00 () /0-0 () #-00 () /0-0 () #-00 () /0-0 () LOAD BY- PASS 8 x STUD LEVER 8 x STUD LEVER ()#-0 LEVER ()#-0 LEVER 8 x STUD LEVER 8 x STUD LEVER 8 x STUD LEVER 8 x STUD LEVER D W H S: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action and also operates bypass device. CONNECTORS: Stud type units supplied with /8 - hex head nuts with Belleville washers. For connector kits, order as extra K0 (00 ). For twin lug connectors order as extra: K0 (0 ). (NOTE: U is UL Listed based on Parallel 0 conductors only. Use K0 with () 0 conductors.) FIFTH TERMINAL: For field installed fifth terminal, order as extra K8. FACTORY-INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 oʼclock position for use on Alliant Energy lines when a fifth terminal is required. 00 amp continuous when used on Alliant Energy lines. ** SHORT CIRCUIT CURRENT RATING: See chart on page 000 7 8 7 8 7 8 7 8 7 8 7 8 9 7 8 0 0 0 8 8 8 U779-RRL-K (Shown w/o K connectors) 0 9,,,,,, Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP / POSITION & TERMINAL HORIZONTAL GANGS RINGLESS 00 VAC CENTER WIREWAY U80-XL-KK 7 7 7 7 80- SIDE WIREWAY # OF POS SERVICE OH/UG U80-XL-KK C.P. OH/UG U80-XL-KK C.P. OH/UG U80-XL-KK C.P. # OF POS OH/UG U80-XL-KK C.P. OH/UG U80-XL-KK C.P. SERVICE OH OH L7-XL-KK C.P. L7-XL-KK CONNECTOR CU/AL LINE LOAD CONNECTORS CU/AL LINE BY- PASS LOAD BY- PASS #-0 #-/0 HORN D W H 0 00 AMP/POSITION & TERMINAL CENTER WIREWAY RINGLESS W #-0 #-/0 #-0 #-/0 #-0 #-/0 #-0 #-/0 #-0 #-/0 00 AMP/POSITION & TERMINAL SIDE WIREWAY RINGLESS W CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Supplied with / x aluminum bussing. FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number T8K for the oʼclock position, and Kit #K999 for the 9 oʼclock position. EXTRA WIRE SPACE: Extra wire space of provided on the left end of and position gangs. Furnished on both ends of,, and position gangs. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. L7- L7-XL-KK C.P. #-0 #-/0 HORN 8 OH L7-XL-KK C.P. #-0 #-/0 HORN 0 OH L7-XL-KK C.P. #-0 #-/0 HORN 8 7 8 OH L7-XL-KK C.P. #-0 #-/0 HORN 7 HORN D W H HORN HORN 0 7 8 HORN 9 HORN 7,,,,,,,,,, 7 MULTIPLE POSITION 00 AMP / POSITION & TERMINAL HORIZONTAL GANGS RINGLESS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP / POSITION & TERMINAL HORIZONTAL GANG RINGLESS 00 VAC 7- MULTIPLE POSITION 00 AMP / POSITION & TERMINAL HORIZONTAL GANG RINGLESS 00 VAC # OF POS SERVICE U7-RL-KK (shown without -KK bypass) 00 AMP & TERMINAL RINGLESS W CONNECTORS CU/AL LINE LOAD BY- PASS OH U7-RL-KK H.O. #-0 #-/0 HORN D W H, OH U7-RL-KK H.O. #-0 #-/0 HORN, OH U7-RL-KK H.O. #-0 #-/0 HORN, OH U7-RL-KK H.O. #-0 #-/0 HORN 0 7 8, OH U7-RL-KK H.O. #-0 #-/0 HORN 9, CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Supplied with / x aluminum bussing. FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number T8K for the oʼclock position, and kit #K999 for the 9 oʼclock position. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP / POSITION TERMINAL VERTICAL GANG RINGLESS 00 VAC MULTIPLE POSITION SERVICE OH U9-XL-KK 00 AMP TERMINAL RINGLESS W C.P. CONNECTORS CU/AL LINE LOAD BY- PASS #-0 #-/0 HORN D W H 8 8 U9-XL (shown without -KK bypass) CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Supplied with / x aluminum bussing. FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number T8K for the 9 oʼclock position. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. 00 AMP / POSITION TERMINAL VERTICAL GANG RINGLESS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP / POSITION & TERMINAL HORIZONTAL GANGS RINGLESS 00 VAC U-X-KK 7 MULTIPLE POSITION 00 AMP / POSITION & TERMINAL HORIZONTAL GANGS RINGLESS 00 VAC SERVICE 7 NO. OF POS. 00 AMP / POSITION & TERMINAL RINGLESS W OH/UG - CONNECTOR CU/AL LINE LOAD BY- PASS D W H 7 /8 - #-0 OH **U-X-KK C.P. STUD HORN 8 /8 - #-0 OH **U-X-KK C.P. STUD HORN 8 /8 - #-0 OH **U-X-KK C.P. STUD HORN 8 7 8 #-0 #-0 UG U-X-KK-K-PED* C.P. HORN 8 PED #-00 #-0 UG U-X-KK-K-PED* C.P. HORN 8 A PED UG ()#-00 #-0 U-X-KK-K-PED* C.P. HORN 8 7 8 PED ()#-00 #-0 UG U-X-KK-K-PED* C.P. HORN 8 7 8 PED /8 - /8 - UG **U-X-KK-PED* C.P. STUD STUD HORN 8 8 PED : For proper hub selection refer to the hub suffix chart on the accessory page. Two hub openings are supplied ( & position only) and the extra opening is closed with a closing plate as standard. To use hub less than, the S8 adaptor is required. FIFTH TERMINAL: For field mounted fifth terminal, order catalog number KT for the 9 oʼclock position. *PEDESTAL: Units may be used with a S9-TO pedestal raceway, see page 0. Order separately. A pedestal extension kit is also available. Order catalog number S7. **CONNECTORS: Units supplied with /8 - hex head nuts with Belleville washers on line side. Order connector kits as extra: K9 (0 ), K0 (00 ) or K (() 00 ). BUSSING: Supplied with / x aluminum bussing on the U- units. Supplied with /8" x aluminum bussing on the U- units. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. - Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP / POSITION TERMINAL LEVER BYPASS HORIZONTAL GANGS 00 VAC 7 87- NO. OF POS. U87-XT 00 AMP / POSITION TERMINAL RINGLESS W OH CONNECTOR CU/AL LINE /8 - LOAD #-0 BY- PASS D W H U87-XT ()C.P. LEVER, STUD 8 U87-XT-K #-00 #-0 ()C.P. LEVER 8, U87-XT-T9-K #-00 #-0 ()C.P. LEVER 8, /8 - STUD #-00 /8 - STUD #-00 #-0 #-0 #-0 #-0 U87-XT ()C.P. LEVER, U87-XT-K ()C.P. LEVER, U87-XT ()C.P. LEVER, U87-XT-K ()C.P. LEVER, CONNECTORS: Units supplied with /8 - hex head nuts with Belleville washers on line side. For single lug connector kits, order as extra: K9 (0 ) or K0 (00 ). For twin lug connectors order: K0 (0 ) or K (00 ). LINE SIDE CONNECTORS: Includes #-00 connectors factory installed on line side.bypass: Lever supplies clamping action on meter spades and also operates bypass device. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. MULTIPLE POSITION 00 AMP / POSITION TERMINAL LEVER BYPASS HORIZONTAL GANGS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 00 AMP / POSITION 7 TERMINAL HORIZONTAL GANG LEVER BYPASS RINGLESS 00 VAC CENTER WIREWAY 7- MULTIPLE POSITION 00 AMP / POSITION 7 TERMINAL HORIZONTAL GANG LEVER BYPASS RINGLESS 00 VAC AMPS 00 00 00 00 00 00 00 00 00 00 NO. SERVICE OF POS. OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG U7-XT-PED (shown without pedestal or line connectors) 00 AMP 7 TERMINAL RINGLESS W OVERHEAD / UNDERGROUND* U7-XT-PED ()C.P. CONNECTOR CU/AL LINE LOAD /8 - STUD #-00 /8 - STUD #-00 /8 - STUD #-00 /8 - STUD #-00 /8 - STUD #-00 #-0 #-0 #-0 #-0 #-0 #-0 #-0 #-0 #-0 #-0 BY- PASS LEVER D W 8 H PED, U7-XT-PED-K7 ()C.P. LEVER PED 8, U7-XT-PED ()C.P. LEVER PED, U7-XT-PED-K7 ()C.P. LEVER PED, U7-XT-PED ()C.P. LEVER PED, U7-XT-PED-K7 ()C.P. LEVER PED, U7-XT-PED ()C.P. LEVER PED, U7-XT-PED-K7 ()C.P. LEVER PED, U7-XT-PED ()C.P. LEVER 7 PED 8, U7-XT-PED-K7 ()C.P. LEVER 7 PED 8, S: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTOR KITS: Line wire sections supplied with studs. For connector kits order K08 (single-0 ), K (single-00 ). For twin connectors order K (twin-0 ) or K08 (twin-00 ). Line connectors can be reversed to change from OH to UG service. LINE SIDE CONNECTORS: Includes #-00 connectors factory installed on line side. UNDERGROUND PEDESTALS: For underground service order S9-TO pedestal raceway, see page 0. A pedestal extension kit is also available. Order catalog number S7. BUSSING: Bussing is /8 x aluminum. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8

00A/00A 0VAC TERMINAL METERING BANKS 9 U88 CONDOMINIUM METERING BANKS A / POSITION U88 AMP POSITIONS TERM SERVICE LINE LOAD WIDTH WT (#) U90-X-KK-K-PED 00 OH/UG /0-0 #-0 8 -/ U90-X-KK-K* 00 OH/UG /0-0 #-0 -/ 8 U90-X-KK-K-PED 00 OH/UG /0-0 #-0-9/ 88 U90-X-KK-K* 00 OH/UG /0-0 #-0-9/ 88 U90-X-KK-K-PED 00 OH/UG /0-0 #-0 -/ 07 U90-X-KK-K* 00 OH/UG /0-0 #-0 -/ 07 00A/00A 0VAC TERMINAL METERING BANKS U90-X-KK-K-PED 00 OH/UG /0-0 #-0 -/ 8 U90-X-KK-K* 00 OH/UG /0-0 #-0 -/ 8 U90-X-KK-K-PED 00 OH/UG /0-0 #-0 9-/ U90-X-KK-K* 00 OH/UG /0-0 #-0 9-/ 00A / POSITION AMP POSITIONS TERM SERVICE LINE LOAD WIDTH WT (#) U88-X-KK-K-PED 00 OH/UG /0-0 #-0 -/ 8 CONDOMINIUM U88-X-KK-K* 00 OH/UG /0-0 #-0 -/ 8 U88-X-KK-K-PED 00 OH/UG /0-0 #-0-9/ 88 U88-X-KK-K* 00 OH/UG /0-0 #-0-9/ 88 U88-X-KK-K-PED 00 OH/UG /0-0 #-0 -/ 07 U88-X-KK-K* 00 OH/UG /0-0 #-0 -/ 07 U88-X-KK-K-PED 00 OH/UG /0-0 #-0 -/ 8 U88-X-KK-K* 00 OH/UG /0-0 #-0 -/ 8 U88-X-KK-K-PED 00 OH/UG /0-0 #-0 9-/ U88-X-KK-K* 00 OH/UG /0-0 #-0 9-/ * For Alliant Energy. UNDERGROUND PEDESTALS: For underground service order S9-TO pedestal raceway, see page 0. A pedestal extension kit is also available. Order catalog number S7. AIC RATING: All models are rated K AIC with Siemens breakers. : Units supplied with one () closing plate. Order hubs separately, see accesory page. FIFTH TERMINAL: For field installed fifth terminal, order KT. Installs in the 9 oʼclock position. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information on page 0 of this catalog. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9

0 CONDOMINIUM METERING BANK DIMENSIONAL INFORMATION CONDOMINIUM METERING BANKS U88 U88 0" CONDOMINIUM METERING BANK DIMENSIONAL INFORMATION 0" /8" I.D. /8" I.D. 9 /" O.D. /" U88-X-KK-K-/00-PED. CONC K.O. CONC K.O. CONC K.O. 7/8 SOLID K.O. / SOLID K.O. PED PED U88-X-KK-K-/00 U88-X-KK-K-/00-PED PED PED. CONC LARGE K.O. OPENING W/CP. CONC K.O. CONC K.O. CONC CONCK.O. K.O. U88-X-KK-K-/00 CONC K.O. CONDOMINIUM PEDESTAL OPTION Pedestal Raceway S9-TO PED PEDESTAL OPTION Pedestal Extension Unit S7 00 amp FIFTH TERMINAL KT (Block with square hole) BRANCH CIRCUIT BREAKER CHART Manufacturer 0K Models K Models QP, QN QPH, QNH Cutler-Hammer BR, HPQ, QPGF Square D G.E. (0 Amp Max.) Homeline THQL, THQL-GF Siemens 0

00 / 00 AMP & TERMINAL METER MAIN - 0 / 0 VAC 00 AMP & TERMINAL LOAD CENTER U8-XL-00-KK AMP 00 / 00 AMP & TERMINAL RINGLESS W HORN BYPASS LINE CONNECTORS CU/AL BY- PASS D W H 00 OH U8-RL-00-KK H.O. #-/0 HORN. 8 0, 00 00 SERVICE OH OH U8-RL-00-KK U8-XTL-00-KK 8 7 7 H.O. C.P. 0 UAP0-XL-KK #-0 #-0 HORN HORN. 8 8 U8 0,,,, 00 / 00 AMP & TERMINAL METER MAIN - 0 / 0 VAC 00 AMP & TERMINAL LOAD CENTER BREAKERS: Rated K AIC with Siemens main installed. S: Meter mains supplied with hub opening only. For proper hub selection, refer to the accessory page. FIFTH TERMINAL: For field mounted fifth terminal, order catalog number KT for U8 & U8 in 9 oʼclock position only. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. NOTE: U8 has provisions for 8 single pole breakers and sub-feed lugs. METER MAIN TERMINAL RINGLESS METER SOCKET / CB COMBO ALUMINUM CONSTRUCTION AMPS 00 CONNECTORS CU/AL SERVICE BY- LINE PASS D W H 7 OH UAP0-XL-KK C.P. #-0 HORN 8,,,, S: Supplied with standard hub opening in top with closing plate. BUSSING: Load side bus bars and circuit breaker interior are made from plated copper. WIREWAY: Provided with underground pull section wireway with removable cover. BREAKERS: Breaker section has provision for six double pole plug-in type circuit breakers. All circuit breakers will be parallel. To comply with NEC wire bending space requirements, the maximum single breaker amperage is 00 amps restricted to /0 copper conductor. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

M I L B A N K 0 AMP & TERMINAL METER MAIN RINGLESS 00 AMP MAX 0 AMP CONTINUOUS DUTY PEDESTAL OPTION Extension Unit S88 " 7/" Grade Line Grade Line " 7/8" 8" Grade Line 89 8" 0 AMP & TERMINAL METER MAIN RINGLESS SERVICE PEDESTALS U89-O-/00 0/0 VAC U78-O-WI (Shown w/o line side connectors) 00 VAC 0 AMP TERMINAL METER MAIN WITH BREAKER RINGLESS W 0 / 0V # OF SERVICE TERM CONNECTOR CU/AL LINE /8 - STUDS /8 - STUDS /8 - STUDS LOAD /0-00 /0-00 /0-00 BY- PASS D W H UG U89-O-00/00 ** BLANK LEVER 7 8 UG U89-O-/0 ** BLANK LEVER 7 8 UG U89-O-/00 ** BLANK LEVER 7 8 BREAKERS: Supplied from factory with double-pole, Milbank UQFB or UQFBH (,000 AIC) bolt-on circuit breakers. CONNECTORS: The line wire section is supplied with /8 - studs with hex nuts and captive Bellville washers. For line side connectors, order as extra catalog numbers K9 (single-0 ), or K0 (single-00 ), or for twin K0 (twin-0 ). Order one kit per unit. EXTENSION KIT: For extension kit order as extra catalog number S88. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. # OF TERM 0 AMP & TERMINAL WITHOUT BREAKER PROVISION RINGLESS W SERVICE UG UG U78-O-WI** U78-O-T9-WI ** BLANK BLANK CONNECTOR CU/AL LINE #-0 #-0 LOAD ()#-0 ()#-0 BY- PASS BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. EXTENSION KIT: For extension kit order as extra catalog number S88. HANGING HOOK: Units supplied with hanger hooks for easy mounting. CONNECTORS: On the U78-O-WI and U78-O-T9-WI, the connectors K9 (single-0 ) are factory installed on the line side. Load side is furnished with K0 (twin-0 ). FACTORY-INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 oʼclock position for use on Alliant Energy lines when a fifth terminal is required. ** SHORT CIRCUIT CURRENT RATING: See chart on page LEVER LEVER 78 D W H 7 8 7 8 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 / 00 AMP TERMINAL METER PEDESTAL PARALLEL MAIN 0 / 0 VAC MILBANK NU8980-O-KK STD = 79" -LP = 70" STD = " -LP = " Grade Line 00 / 00 AMP W RINGLESS UNDERGROUND FEED CONNECTOR CU/AL LINE LOAD BY- PASS MAIN BREAKER D W H BLANK #-0 NU8980-O-KK KCMIL CB HORN * 9 79 NU8980-O-KK-LP BLANK #-0 KCMIL CB HORN * 9 79 BLANK #-0 NU8980-O-SF00-KK KCMIL #-/0 HORN Q00H 9 70 NU8980-O-SF00-KK-LP BLANK #-0 KCMIL #-/0 HORN Q00H 9 70 NU8980-O-00-KK BLANK #-0 KCMIL /0-00 HORN UQFPH 9 79 NU8980-O-00-KK-LP BLANK #-0 KCMIL /0-00 HORN UQFPH 9 70 * FIELD INSTALLED CIRCUIT BREAKER REQUIRED. MAIN CIRCUIT BREAKERS: All main breakers are parallel connected. For series wired main order wire kit #K7 and UQFPH-M type circuit breaker. See Milbank circuit breaker chart on accessory page. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers small frame plug-in type circuit breakers (GE, Siemens, Cutler-Hammer, Murray). SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of circuit interior. Only two single pole spaces available. FIFTH TERMINAL: For field installed th terminal order KT. Mounts in 9 o'clock position only. BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service. EXTENSION KIT: Available for low profile (-LP) units only. Order kit # K9. See accessory page. 00 / 00 AMP TERMINAL METER PEDESTAL PARALLEL MAIN 0 / 0 VAC SERVICE PEDESTALS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

U9 AND U70 PEDESTALS 0/0V GRADE LINE U9-O-00-KK U70-O-00S-KK U9 AND U70 PEDESTALS 0/0V SERVICE PEDESTALS AMP 00 00 BYPASS HORN 00/00 AMP TERMINAL RINGLESS HORN BYPASS U9-O-00-KK TERM LINE CONNECTORS CU/AL LBS. #-0 7 D W H 7 78 HORN U9-O-00-KK #-0 7 7 78,,,, FIFTH TERMINAL: For field installed th terminal, order KT. Installs in the 9 oʼclock position. INTERLOCK KIT: For generator auxiliary circuit breaker interlock for large frame QN with small frame Q order K8; for larger frame QN with larger frame QN order K80; for small frame Q with small frame Q order K80. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers small frame plug-in type circuit breakers (GE, Siemens, Cutler-Hammer, Murray). NOTE: Ten additional single pole spaces for 00A version and eight additional single pole spaces for 00A version. AMP BYPASS 00 HORN 00 AMP TERMINAL RINGLESS HORN BYPASS MAIN WIRED U70-O-00S-KK SERIES LINE CONNECTORS CU/AL LBS. #-0 79 D W H 80 Up to two receptacle/circuit breaker kits can be factory installed. Contact factory for factory installed kits. To increase pedestal height, order field-installed post extension kit K708. For field installed fifth terminal in the 9 oʼclock position, order kit KT. For field converting from parallel to series wired, order kit K9. For field converting from series to parallel wired, order kit K9. Units are parallel wired from the factory. NOTE: Four additional single pole spaces., SOLID Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 / 00 AMP & TERMINAL 00V PEDESTAL RINGLESS NO. OF POS. U78-O-KK 00/00 AMP / POSITION & TERMINAL 00V RINGLESS W UG CONNECTOR CU/AL LINE GRADE LINE LOAD BY- PASS D" W" H" U8-O-KK U8-O-KK BLANK #-0 #-0 HORN 8 9 U78-O-KK BLANK #-0 #-0 HORN 8 8 7 EXTENSION UNIT: For " burial applications, order extension unit K800; for 0" burial applications, order () catalog # K800 for the U8. Order catalog number S8988 for the U78. CONNECTORS: Extruded aluminum connectors are tin plated. FIFTH TERMINAL: For a field mounted fifth terminal, order as extra catalog number KT in the 9 oʼclock position. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. UTILITY APPROVAL: Wisconsin utility approved..0 8.00 00 / 00 AMP & TERMINAL 00V PEDESTAL RINGLESS SERVICE PEDESTALS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

JOINT USE TERMINATION CABINET 8" Grade Line U9 " JOINT USE TERMINATION CABINET SERVICE PEDESTALS JOINT USE TERMINATION CABINET CONNECTOR CU/AL LINE LOAD BY- PASS D" W" H" U9-O BLANK NONE NONE NONE 8 " / " 7, TELEPHONE AND CABLE CONDUCTORS: This unit will accommodate both telephone and cable conductors, eliminating the use of multiple, unsightly network interface devices on the outer structure of the home, while providing tamper resistance to the communication modules. SINGLE LOCATION POINT OF SERVICE: The U9-O combined with the Milbank meter pedestal provides a single location point of service making access for utility service personel convenient and efficient. APPROVED: The U9-O is recommended by all major WISCONSIN UTILITIES. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 AMP SERIES U & U7 RINGLESS METERED PEDESTAL 7 U-O-00S UL Listed File E909. 00 amp maximum, 0/0 V, W. Ringless type meter socket with horn bypass and stainless steel latch. Short circuit withstand rating 0K AIC, for K AIC, order with suffix. Type R construction for durable outdoor use. Milbank grey polyester powder coat finish. Wire terminations accept copper or aluminum conductors. Line & Neutral: () #-0 per phase. Line Ground: () #-/0. Load (CB): /0 to 00 per pole. Load Neutral: () #-0. Load Ground: () #-/0, () #/. Commercial grade, plug-in main circuit breaker. Available in 00,, 0 & 00 amp. Type UQFP-M. circuit plated copper interior accepts () -pole or () -pole standard plug-in type circuit breakers. Branch circuit rated to amps max. Acceptable manufacturers: Milbank, Cutler-Hammer, GE or Siemens. Factory installed receptacle bridge and receptacle / circuit breaker available. See below or consult factory for more options. SINGLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) RECEPTACLE U-O-00S UQFP-M-00 00 Circuit 8 NONE U-O-00S-0GR UQFP-M-00 00 Circuit 8 () 0GR U-O-00S UQFP-M-00 00 Circuit 8 NONE U-O-00S-GR UQFP-M-00 00 Circuit 8 () 0GR DOUBLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) RECEPTACLE U7-O-00S () UQFP-M-00 Series 00 Circuit NONE U7-O-00S-0GR () UQFP-M-00 Series 00 Circuit () 0GR U7-O-00S () UQFP-M-00 Series 00 Circuit NONE U7-O-00S-GR () UQFP-M-00 Series 00 Circuit () 0GR A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available. Consult factory for factory-installed receptacle kits. Pedestals are stocked with series wired main circuit breakers. Order K9 kit to field convert to parallel main lug circuit breaker. For parallel wired main circuit breakers, change S suffix to P (Ex.: U-O-00P). K Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals available. Order U8 (single meter) or U9 (double meter) prefix. K0 pad mount kit required. Order separately. 00 AMP SERIES U & U7 RINGLESS METERED PEDESTAL SERVICE PEDESTALS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 00 AMP & 7 TERMINAL HEAVY DUTY RINGLESS 00 VAC PEDESTAL OPTION Extension Unit S88 " " MILBANK 00 AMP & 7 TERMINAL HEAVY DUTY RINGLESS 00 VAC SERVICE PEDESTALS # OF TERM SERVICE 00 AMP TERMINAL RINGLESS W UG CONNECTOR CU/AL LINE LOAD #-0 BY- PASS D W H UG U908-O** BLANK /0-/0 LEVER 8 # OF TERM 7 7 SERVICE UG UG U907-O 00 / 00 AMP 7 TERMINAL RINGLESS W UG U907-O U907-O-K* /" BLANK BLANK CONNECTOR CU/AL LINE /0-/0 #-0 LOAD #-0 #-0 BY- PASS LEVER LEVER D W H EXTENSION UNIT: For a field mounted, extension unit, order catalog number S88. GROUND: U908-O is supplied with a bonded ground which may be isolated when desired. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. *INCLUDES: #-0 connectors on line side for Alliant Energy. **NEUTRAL: The U908-O is supplied with a center disconnect neutral. " 8 8 907 908 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8

00 AMP TERMINAL MOBILE HOME METER PEDESTALS RINGLESS 0/0 VAC 9 /8" " /" U-O AMPS STABILIZER FOOT 0" " " U & U PLUG-IN BREAKER COMPATIBILITY CHART MILBANK CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D -00 Q / QN HQP / BR / WBJ Q / QN MD Q LINE 00 Q QUICKLAG P / BR / HQP QP MP Q LINE HOMELINE U-O 00 AMP TERMINAL MOBILE HOME METER PEDESTALS RINGLESS 0/0 VAC U-O-T9 U-O-T9 METER POSITIONS SINGLE BY- MOUNTING PASS TYPE LEVER 00 AMP TERMINAL RINGLESS TWIN LINE CONNECTORS CU/AL DOUBLE LEVER POST # AWG-0 CIRCUIT PROV. POST # AWG-0 DESCRIPTION Provisions for Main with Branch or Parallel Breakers LEVER BYPASS: Lever provides clamping action on meter spades and also operates bypass device. APPLICATION: The U & U pedestals are suitable for use as service equipment or mobile home service equipment. K08 / K88 for direct burial application is included with unit. K for pad mount application must be ordered as extra. BREAKERS: These units are wired as parallel mains and have provisions for six circuits: six single-pole or three double-pole breakers. FIFTH TERMINAL: For field installed fifth terminal order catalog number K8 (with neutral wire). May be installed in oʼclock or 9 oʼclock position. SERVICE PEDESTALS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9

0 0 AMP TRANSFORMER RATED,, 8 & TERMINAL SINGLE & DOUBLE POSITION RINGLESS / RING TYPE 00 VAC CT-- RATED 90 99 7 9 78 79 887 889 0 AMP TRANSFORMER RATED,, 8 & TERMINAL SINGLE & DOUBLE POSITION RINGLESS / RING TYPE 00 VAC NO. OF TERMS NO. OF TERMS METER FORM 0 AMP TRF RATED & PIECE COVER RINGLESS OH/UG CONNECTORS CU S UC7-XL* C.P. # - #MAX D W H 8 0 8 S UC9-XL C.P. # - #MAX 8 0 8 S UC78-XL C.P. # - #MAX 8 0, 8, 9 & (ALT) 0S UC79-XL C.P. # - #MAX 8 0 8 S UC887-XL* C.P. # - #MAX 9 UC79-XL METER FORM, 8, 9 & (ALT) 0S 0 AMP RINGLESS PLUNGER BYPASS CONNECTORS CU UC889-XL* C.P. # - #MAX 9 * Approved for use with Wisconsin Electric Power Company only. UC887-XL and UC889-XL have -piece cover. D W H UC8-XL S UC90-RL H.O. # - # 8, 8, 9 & (ALT) 0S 7 8 UC99-RL H.O. # - # 8,,,,,, NO. OF TERMS 0 AMP TRF RATED DOUBLE POSITION PIECE COVER RING TYPE OH/UG METER FORM CONNECTORS CU D W H 8 S UC7-XL** C.P. # - #MAX 8 0, 8, 9 & (ALT) 0S UC8-XL** C.P. # - #MAX 8 0,, S: For proper hub selection see the hub suffix chart on the accessory page. ** SEALING RINGS: Ring type units are supplied with one MR-, screw type, sealing ring. PREWIRING: If standard factory pre-wiring is required, refer to wiring diagrams in the general engineering section of this catalog. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. SERVICE: Units are rated for overhead or underground feed. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 0

POLYPHASE ENCLOSURES FOR A BASE METERS NEW S999-B-XL S999-B-XL S9997-B-XL S9997-B-XL POLE MOUNTING BRACKETS Order #80 for one pair ( pcs.) with keyhole bracket and mounting hardware. Order #80 for two pair ( pcs.) with mounting hardware. OF POSITIONS S999-B-XL POLYPHASE ENCLOSURE ORDERING INFORMATION D W H C.P. C.P. 0 C.P. 7 0 BRIDGE AND MOUNTING BOARD: Units are supplied with board and bridge. WINDOWS AND COVERS: Units supplied with one x glass window per meter position. If glass demand reset window is desired, add suffix -CW to the catalog number. If metal demand reset cover is desired, add suffix -C to the catalog number. If window shield is desired, add suffix -WS to the catalog number. S: Above units supplied with closing plate. Order hub as extra. Refer to accessory page. MISC POLYPHASE ENCLOSURES FOR A BASE METERS FIELD INSTALLED ACCESSORIES GLASS WINDOW DEMAND RESET COVER ( x ) Catalog No. SDRCW ALL METAL DEMAND RESET COVER ( x ) Catalog No. SDRC WINDOW SHIELD Catalog No. WS

TERMINAL TYPE K METER MOUNTING DEVICE 80 AMPERES CONTINUOUS 00 VAC MISC. TERMINAL TYPE K METER MOUNTING DEVICE 80 AMPERES CONTINUOUS 00 VAC UTILITY WPS WPS WPS SVC. OH/UG OH/UG OH/UG U-X-(*) 00 AMP TERMINAL RINGLESS W OVERHEAD / UNDERGROUND U-X-80* U-X-807* U-XT-907* L&G LUG KIT 980-80 Installed () Large C.P. (-X) 980-807 NONE () Large C.P. (-X) 980-907 NONE () Large C.P. (-X) CONNECTOR CU/AL LINE TWIN -0 KCMIL /"-0 STUD /"-0 STUD LOAD TWIN -0 KCMIL /"-0 STUD /"-0 STUD D W 7 7 7 H (INCHES),,,,,,,,,,,,,,,,,,,,, APPLICATION: For use with W self-contained Type MS-K watthour meters. CAPACITY: 80 amperes continuous / 00 amperes maximum. CONNECTORS: /"-0 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs for conductors from # to 800 CU or AL. Use /" insulated wrench to fasten connectors to block. Phase and neutral connectors included if lug kit number is shown in table as installed. For lugs refer to page of this catalog. ENCLOSURE: Constructed of -gauge galvanized steel suitable for indoor or outdoor installations. BYPASS: Rated 0%, separate manual type, order Milbank kit #K87 (kit includes bypasses). METER MOUNTING: Two position stud type. One set of studs provides out-of-service storage. The in-service studs are positioned so the meter cannot be installed upside-down. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the IN or OUT OF SERVICE position. BLOCKS: Glass fiber reinforced polyester plastic. High arc withstand strength and track resistant. Provisions for lightning arresters. * SHORT CIRCUIT CURRENT RATING: 0,000 RMS sym amps 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

7 TERMINAL TYPE K7 METER MOUNTING DEVICE W 80 AMPERES CONTINUOUS 00 VAC MISC. UTILITY WPS WPS WPS WPS SVC. OH/UG OH/UG OH/UG OH/UG U7-X-8* U7-XT-90* U7-XT-90* U7-X-80* L&G LUG KIT 987-8 Installed 987-90 NONE 987-90 Installed 987-80 Installed Large C.P Large C.P. Large C.P. (x) Large C.P. CONNECTOR CU/AL (INCHES) APPLICATION: For use with self-contained Type MT-K watthour meters on W Wye or -wire delta services. CAPACITY: 80 amperes continuous / 00 amperes maximum. CONNECTORS: /"-0 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs for conductors from # to 800 CU or AL. Use /" insulated wrench to fasten connectors to block. Phase and neutral connectors included if lug kit number is shown in table as installed. For lugs refer to page of this catalog. ENCLOSURE: Constructed of -gauge galvanized steel suitable for indoor or outdoor installations. BYPASS: Rated 0%, separate manual type, order Milbank kit #K88 (kit includes bypasses). METER MOUNTING: The meter is mounted on studs using /"- studs with nuts with captive Belleville washers. The upper studs are positioned so that the meter cannot be installed upside down. Use /" insulated wrench. Another set of studs provides on site OUT OF SERVICE storage. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the IN or OUT OF SERVICE position. * SHORT CIRCUIT CURRENT RATING: 0,000 RMS sym amps 00 VAC LINE LOAD TWIN TWIN -00 KCMIL -00 KCMIL /"-0 /"-0 STUD STUD TWIN TWIN -00 KCMIL -00 KCMIL TWIN TWIN -00 KCMIL -00 KCMIL U7-X-80 80 AMP 7 TERMINAL RINGLESS W OVERHEAD / UNDERGROUND D W 0 0 0 0 H,,,,,,,,,,,,,,,,,,,,,,,,,,,, 7 TERMINAL TYPE K7 METER MOUNTING DEVICE W 80 AMPERES CONTINUOUS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

K / K7 SERIES SCHEMATICS K Lug Kit K Lug Kit K7 Lug Kit K / K7 SERIES SCHEMATICS MISC. OVERHEAD UNDERGROUND UNDERGROUND K7 Lug Kit UNDERGROUND K K7 K K 7 K 7 MILBANK CONN. Z7097-AC Z70-AC Z700-AC Z709-AC Z709-AC Z7099-AC Z7098-AC LINE / LOAD FEED OH/UG Parallel Line/Load OH/UG Parallel Line/Load UG Parallel Line/Load UG DESCRIPTION () Twin #-0 connector (Phase) () Twin #-0 connector (Phase) () Quad #-0 connector (Neutral) () Twin #-00 connector (Phase) () Twin #-00 connector (Phase) () Twin #-0 connector (Phase) () Twin #-0 connector (Phase) MILBANK BYPASS L&G BYPASS DESCRIPTION K87 9 Manual By-pass for K- Series (U) Kit includes K88 8888 Manual By-pass for K-7 Series (U7) Kit inlcudes

LUGS FOR K-SERIES L & G CROSS-REFERENCE #Z709-AC #88 #Z7098-AC #7 #Z709-AC #7-M #Z7099-AC #88 #Z709-AC #7-M MISC. #Z709-AC #7 #Z700-AC # #Z70-AC # Bolt-on type lugs for Milbank stud type meter mounting devices are made of 0-T aluminum to provide high strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug. W L H LUGS FOR K-SERIES L & G CROSS-REFERENCE #Z708-AC MILBANK CONN. # L&G CONN NO. NO. OF CONDUCTORS & SIZE STUD OPENING PRESSURE SCREW HEAD L" W" H" Z709-AC 88 /0-800 9/" /" Allen Z7097-AC 7 Two #-0 9/" /" Allen 8 Z7098-AC 7 Two #-0 9/" /" Allen 7 8 9 Z7099-AC 88 Two #-0 9/" /" Allen 8 Z709-AC 7 /0-800 9/" /" Allen Z709-AC 7-M Two #-00 9/" /8" Allen 8 Z709-AC 7-M Two #-00 9/" /8" Allen Z700-AC Four #-0 7/" /" Allen 7 8 9 Z70-AC Two #-0 9/" /" Allen 7 8 7 Z708-AC 87- Three #-0 9/" /" Allen 7 8

COMMERCIAL METER PEDESTALS OVERVIEW Commercial Pedestals Attractive Easy to install Secure Cost effective COMMERCIAL METER PEDESTALS OVERVIEW MISC. Un-Strut Your Stuff... Ringless Socket ilbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and costeffective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Ring-type Socket Strut and backboard design STANDARD FEATURES COMMERCIAL PEDESTALS Type R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) UL listed Isolated, lockable & sealable utility metering & lug landing sections Lockable customer section for distribution & control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions Most load centers are UL listed for use with various manufacturers circuit breakers All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Commercial Pedestal Utility Lug Landing Customer Interior

APPLICATIONS & ACCESSORIES 7 APPLICATIONS These units are ideal for controlling and metering: Traffic signals Street lighting Irrigation / sprinkler systems Cell towers / telephone vaults Pump stations Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. AVAILABLE FACTORY-INSTALLED OPTIONS MISC. Meter sockets ring type or ringless, to 00 amp (unmetered and dual-metered pedestals also available) Main and branch breakers or T fuses Distribution copper load centers & panel boards Clocks / timers / relays Photoelectric cells and controls Power receptacles pin & sleeve, twist lock or straight blade Contactors definite purpose, electrical or mechanically held, IEC and mercury types Surge protection & lightning arrestors Reserve inlet generator receptacle with interlocked circuit breakers ACCESSORIES K8 Fifth terminal kit for use with ringless meter sockets 0J Fifth terminal kit for use with ring-type meter sockets Motor starters, relays Push button controls Thermostat controls, fans and heating strips Power blocks and terminal blocks Steel, aluminum and plywood back boards Transformers Interlock devices for circuit breakers Available in steel, aluminum (raw painted or anodized) or stainless steel construction with powder-coated finish available in 8 standard colors or special ordered RAL colors consult factory. Available for applications up to 00 amp, 0V, 08V, 0V, 77V, 80V Ø or Ø. CP-TC7D 7-day time clock kit CP-TCH -hour time clock kit CP-TCWIRE Male four-pin connector and wiring harness for use with time clocks other than shown CP-FPAD Fiberglass pedestal mounting base for " pedestal (direct buried) APPLICATIONS & ACCESSORIES CP-ABK/8 Anchor bolt kit (includes four /8 - x 8" anchor bolts) CP-PDMNT-CALT Pedestal mounting base for " pedestal CP-PDMNT-CALT Pedestal mounting base for " pedestal (includes mounting hardware) CP-PDMNT Pedestal mounting base for " pedestal (includes mounting hardware) CP-PE-HOA-POS HOA switch for field installation 7

8 MILBANK ACCESSORIES INTERCHANGEABLE UNIT S MILBANK ACCESSORIES MISC. ADAPTER PLATE (Converts opening to opening.) S8 METAL CLOSING PLATE (for ringless sockets) CP- CLOSING COVERS SMALL RL"OPENING (STANDARD) SUFFIX WL YL ZL DL EL SIZE MILBANK NO. A7 A7 A7 A77 A78 METER CLOSING PLATE (Grey Plastic) 00 LARGE R OPENING (HEAVY DUTY) SUFFIX F G H SIZE MILBANK NO. A80 A8 A8 SUFFIX CHART REMOVABLE CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) LARGE (for -R opening) -XL A7 -X A90 O Plain Top WL For -RL Opening RL Small Hub Opening YL For -RL Opening R Large Hub Opening ZL For -RL Opening XL Small Closing Plate DL For -RL Opening X Large Closing Plate EL For -RL Opening Large Hub Opening F For -R Opening RXL adapted to small Closing Plate G For -R Opening Large Hub Opening RRL adapted to small Hub Opening H For -R Opening FIFTH TERMINALS PEDESTAL EXTENSION UNITS S8988 S88 S7 S88 K9 K800 D W H 8 8 7 8 8 0 9 9 00 amp PLUG-IN FIFTH TERMINAL T8K (Round hole 9 oʼclock position) 00-00 amp FIFTH TERMINAL KT (New style block with square hole in 9 oʼclock position) HEAVY DUTY JAW CLAMPING K8 #K STAKE KIT Suitable for use with pedestals for extra support ANTI-INVERSION CLIP FOR CONDO METERING BANKS (-00 amp) K8 K80 8

MILBANK ACCESSORIES 9 SINGLE CONNECTOR KITS For use with /8 - stud type units only TWIN DISCONNECT SLEEVE M- SUFFIX K K KL SUFFIX K K7 # ( per set) K9-0 K0-00 or () /0-0 -00 or K0L () /0-0 Non-rotating # K08 K ( per set) -0-00 or () /0-0 SUFFIX K KL K SUFFIX Replaces the load or line side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #-0 load-side connector. K0 Includes Safety Barrier Extensions for applications over 00 VAC. Three lugs per kit. K977-INT INTERNAL HEX K0-INT INTERNAL HEX K K8 # K0 K0L K # K K08 ( per set) -0-0 Non-rotating -00 ( per set) -0-00 TAP CONNECTORS ( per set) BYPASS LINK K880 (Bypass links are sold in pairs) MISC. MILBANK ACCESSORIES TRIPLEX GROUND K90 (For factory installed triplex ground add suffix -TG to the catalog number.) TOUCH-UP PAINT A-GP Light Gray AMPS PLUG-IN BREAKER COMPATIBILITY CHART MILBANK CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D -00 Q / QN HQP / BR / WBJ Q / QN MD Q LINE 00 Q QUICKLAG P / BR / HQP QP MP Q LINE HOMELINE MILBANK -POLE 00 AMP LARGE FRAME 0,000 AIC &,000 AIC AMP S 0,000 AIC PLUG-IN,000 AIC PLUG-IN 0,000 AIC PLUG-IN,000 AIC PLUG-IN 0,000 AIC BOLT-ON,000 AIC BOLT-ON 0,000 AIC BOLT-ON 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X UQFP- UQFPH- UQFP-M- UQFPH-M- UQFB- UQFBH- UQFB--X 0 UQFP-0 UQFPH-0 UQFP-M-0 UQFPH-M-0 UQFP-0 UQFBH-0 UQFP-0-X 7 UQFP-7 UQFPH-7 UQFP-M-7 UQFPH-M-7 UQFB-7 UQFBH-7 UQFB-7-X 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X 9

0 CONDUIT AND AMPACITY INFORMATION MAXIMUM OF CONDUCTORS IN CONDUIT u Table from 008 NEC Code Reference: Rigid Metal Conduit TYPE CONDUCTOR SIZE (AWG / ) CONDUIT TRADE SIZES (INCHES) CONDUIT AND AMPACITY INFORMATION MISC. A 8 0 8 /0 /0 /0 /0 0 00 0 00 00 00 700 70 *CU B 0 0 8 00 0 0 7 00 0 8 0 80 0 0 7 THHN, THWN, THWN- XHH, XHHW, XHHW- 0 8 /0 /0 /0 /0 /0 /0 /0 0 0 00 70 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 9 7 0 0 9 7 7 0 9 0 8 7 0 7 0 7 7 8 7 7 9 8 0 7 0 8 7 7 0 9 8 9 9 9 7 9 7 u This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ** ALUMINUM CONDUCTORS (W IN CONDUIT) 7 C (7 F) AL or **Cu-Clad AL A 0 8 /0 /0 /0 /0 0 00 0 00 00 00 700 70 C 0 0 0 0 7 90 00 0 80 0 0 0 70 0 0 7 8 A = Size: AWG/MCM *B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, W. **C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 0-) AMBIENT TEMP.C CORRECTION FACTOR 0 89 09 79 8 8 9 8 0 7 87 0 0 7 9 8 0 7 AMPACITY CORRECTION FACTORS AMBIENT TEMP.F -.0 70-77 - 0.00 78-8 -.9 87-9 - 0.88 9-0 -.8 0 - - 0.7 - -.7 - - 0.8-0 -. - 8 Overall ampere ratings of U/L listed Milbank multiple position meter sockets are based on 008 N.E.C. Handbook Article 0-8 and ANSI / UL- (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank U/L listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for U/L listed and non U/L listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 7 C insulated wire conductor, sized in accordance with Table 0- of the National Electric Code. NO. OF METER POSITIONS GANG SOCKET OVERALL AMPACITIES 00A / POS. AMPACITY 00A 00A 00A A 70A A / POS. AMPACITY 00A A 0A 8A 0A 0A / POS. AMPACITY 00A A 70A 8A 9A 00A / POS. AMPACITY 00A 70A 0A 0A 8A Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed amps for AWG, 0 amps for AWG, and 0 amps for 0 AWG copper: or amps for AWG and amps for 0 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. 0

SHORT CIRCUIT CURRENT RATING CHART SHORT CIRCUIT CURRENT RATING CHART PAGE RATING LABEL SCCR SWITCHES 9 U77 00007 K 9 U80 00007 0K 9 U 008 K 9 U80 008 K 0 U90 K 0 U9 K 0 U8 K 0 U9700 7 K 0 U970 7 K U7 887 0K U7 887 0K U70 7 K U 0 K SHORT CIRCUIT CURRENT RATING CHART U000 009 K U779 009 K U9 0 K U0 0 K U89 00 K U78 077 K U-X-80 007 0K U-X-807 0070 0K U-X-907 0998 0K U7-X-8 00 0K U7-X-90 000 0K U7-X-90 09 0K U7-X-80 8 0K

ENERGIZATION OF ELECTRICAL EQUIPMENT IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING ENERGIZATION OF ELECTRICAL EQUIPMENT MISC. A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. ) Equipment is clean and dry. B. Make a thorough examination to verify: ) Tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. ) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING A. Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. ) Take action to prevent/decrease damage to property in the event of failure of the installation. ) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. NOMINAL SIZE 0 0 0 / / / RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* SCREW BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL JOINT DESCRIPTION NUT Brass Nut or Extruded Hole CU or AL Busbar </8 Steel Nut or EH; CU or AL Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole HEAD TYPE ALL ALL ALL ALL ALL ALL ALL HEX TORQUE ( INCH LBS. ) 0- in. lbs. -0 in. lbs 0- in. lbs 0- in. lbs 0-0 in. lbs. 0-0 in. lbs. 0-0 in. lbs. 0-70 in. lbs. / STEEL Steel Nut or EH; CU or AL Busbar HEX 00-0 in. lbs. /8 STEEL Steel Nut HEX 0-00 in. lbs. / STEEL Steel Nut HEX 00-0 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum

MATERIALS AND FINISHES MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET FINISH gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated. (AISI G90) gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 0-T, Tin-plated for CU/AL wire. Bus Bar: Alloy; 0-o & 0-O ALUMINUM SHEET 000 series aluminum sheet, H, or 0 series aluminum sheet, H. Where applicable thicknesses range from.0. COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. MISC. MATERIALS AND FINISHES RATING PROCESS Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. NEMA RATING All Milbank meter sockets, CT cans and meter socket / breaker units have a NEMA R rating.

METER FORMS DIAGRAM A W with P.T. & C.T. Single Stator Meter(W ) - Form S T Socket, Test Switch #TS0-00 DIAGRAM B W with C.T. Single Stator Meter(W ) - Form S T Socket, Test Switch #TS0-00 DIAGRAM C W with C.T.ʼs Single Stator Meter(W ) - Form S T Socket, Test Switch #TS07-00 DIAGRAM D W or W Network with C.T.ʼs Stator Meter - Form S 8T Socket, Test Switch #TS07-00 DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D METER FORMS SWITCHES P.T. I LINE N (BONDED) (ALT.LOC.) P PN C C C.T. DIAGRAM E LOAD DIAGRAM E W Δ with P.T.ʼs & C.T.ʼs Stator Meter - Form S 8T Socket, Test Switch #TS07-00 I LINE N (BONDED) (ALT.LOC.) P PN C C C.T. DIAGRAM F LOAD DIAGRAM F W Δ with C.T.ʼs Stator Meter - Form S 8T Socket, Test Switch #TS07-00 P P C C C C I C.T. LINE N LOAD (BONDED) C.T. DIAGRAM G W Y with C.T.ʼs Stator Meter - Form S T Socket, Test Switch #TS0-009 DIAGRAM G I LINE P P C PN C C C N (BONDED) C.T. DIAGRAM H C.T. LOAD DIAGRAM H W Y with P.T.ʼs & C.T.ʼs Stator Meter - Form S T Socket, Test Switch #TS0-009 P P PN C C C C C C P P PN C C C C C C P P P C C C C P P P C C C C LINE PT PT C.T. C.T. LOAD DIAGRAM I W Y or Δ with C.T.ʼs Y Stator Meter - Form 9S Δ Stator Meter - Form 8S T Socket, Test Switch #TS0-009 LINE C.T. C.T. LOAD DIAGRAM J W Y with P.T.ʼs & C.T.ʼs Stator Meter - Form 9S T Socket, Test Switch #TS0-009 LINE N (BONDED) C.T. C.T. LOAD C.T. PT PT LINE N (BONDED) C.T. C.T. LOAD C.T. DIAGRAM I DIAGRAM J P P P PN C C C C C C P P P PN C C C C C C PREWIRING: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. C.T. LOAD C.T. PT PT PT LINE N (BONDED) C.T. C.T. LOAD C.T.

APPROVING UTILITIES ALLIANT WI ELECTRIC PUBLIC SERVICE MADISON GAS & ELE. PG.NO. ENERGY ENERGY (WE) OF WI MGE L7-XK-KK X X X L7-XK-KK X X X L7-XK-KK X X X L7-XK-KK X X X L7-XK-KK X X X NU8980-O-00-KK X X X NU8980-O-00-KK-LP X X X NU8980-O-KK X X X NU8980-O-KK-LP X X X NU8980-O-SF00-KK X X X X NU8980-O-SF00-KK-LP X X X X S9-TO X X X X 0 S7 X X X X 0, 8 S999-B-XL X X X S999-B-XL X X X S9997-B-XL X X X SDRC X X X SDRCW X X X U-RXL X X X 9 U-X-KK X X X X U-X-KK-K-PED X X X X U-X-KK X X X X U-X-KK-K-PED X X X X U-X-KK X X X X U-X-KK-K-PED X X X X U-X-KK-K-PED X X X X U-X-KK-K-PED X X X X U78-O-T9-WI X U78-O-WI X X X X U77-XL-TG-KK X X X X 9 U779-RRL-T9-K X U779-RRL-K X U78-O-KK X X X X U0-X-K7 X U9-X-K7 X U9-XL-KK X X X U7-XT-PED X X X 8 U7-XT-PED-K7 X 8 U7-XT-PED X X X 8 U7-XT-PED-K7 X 8 U7-XT-PED X X X 8 U7-XT-PED-K7 X 8 U7-XT-PED X X X 8 U7-XT-PED-K7 X 8 U7-XT-PED X X X 8 U7-XT-PED-K7 X 8 U87-XT X X X 7 SWITCHES APPROVING UTILITIES

APPROVING UTILITIES ALLIANT WI ELECTRIC PUBLIC SERVICE MADISON GAS & ELE. PG.NO. ENERGY ENERGY (WE) OF WI MGE APPROVING UTILITIES MISC. U87-XT-K X 7 U87-XT X X X 7 U87-XT-K X 7 U87-XT X X X 7 U87-XT-K X 7 U000-O-T9-KL-KL X U000-O-KL X U8-O-KK X X X X U89-O-00/00 X X X X U89-O-/0 X X X X U89-O-/00 X X X X U80-O-TG-KK X 9 U-O-XXX X 9 U-O-XXX X 9 U9-O X X X X U-X-QG X X X U-X-80 X U-X-807 X U-XT-907 X U7-X-80 X U7-X-8 X U7-XT-90 X U7-XT-90 X U70-XL X X X U80-XL X 9 U80-XL-T9 X 9 U-O-00S X X X X 7 U-O-00S-0GR X X X X 7 U-O-00S X X X X 7 U-O-00S-GR X X X X 7 U7-O-00S X X X X 7 U7-O-00S-0GR X X X X 7 U7-O-00S X X X X 7 U7-O-00S-GR X X X X 7 U70-O-00S-KK X U8-RL-00-KK X X X X U8-RL-00-KK X X X X U88-X-KK-K-PED X 9 U88-X-KK-K X X X 9 U88-X-KK-K-PED X 9 U88-X-KK-K X X X 9 U88-X-KK-K-PED X 9 U88-X-KK-K X X X 9 U88-X-KK-K-PED X 9 U88-X-KK-K X X X 9 U88-X-KK-K-PED X 9 U88-X-KK-K X X X 9

APPROVING UTILITIES 7 ALLIANT WI ELECTRIC PUBLIC SERVICE MADISON GAS & ELE. PG.NO. ENERGY ENERGY (WE) OF WI MGE U90-X-KK-K-PED X 9 U90-X-KK-K X X X 9 U90-X-KK-K-PED X 9 U90-X-KK-K X X X 9 U90-X-KK-K-PED X 9 U90-X-KK-K X X X 9 U90-X-KK-K-PED X 9 U90-X-KK-K X X X 9 U90-X-KK-K-PED X 9 U90-X-KK-K X X X 9 U9-O-00-KK X U9-O-00-KK X U7-RL-KK X X X X U7-RL-KK X X X X U7-RL-KK X X X X U7-RL-KK X X X X U7-RL-KK X X X X U7-RL X X X U7-XL X X X U787-RL-TG-KK X X X X 7 U77-RL X X X 8 U80-XL-KK X X X X U80-XL-KK X X X U80-XL-KK X X X U80-XL-KK X X X X U80-XL-KK X X X X U8-RXL X X X 0 U907-O X X X 8 U907-O-K X 8 U908-O X X X 8 U90-RXL X X X 8 U90-DL X X X 0 U9-O X X X 0 U9700-RRL X X X X 0 U970-RXL X X X X 0 UC90-RL X 0 UC99-RL X 0 UC9-XL X X X 0 UC7-XL X X X 0 UC8-XL X X X 0 UC887-XL X X X 0 UC889-XL X X X 0 UC78-XL X X X 0 UC79-XL X X X X 0 UC7-XL X X X 0 WS X X X MISC. APPROVING UTILITIES 7

8 INDEX INDEX CAT NO. PG CAT NO. PG CAT NO. PG CAT NO. PG 00................... 8 T8K.................. 8 A7.................. 8 A7.................. 8 A7.................. 8 A77.................. 8 A78.................. 8 A7.................. 8 A80.................. 8 A8.................. 8 A8.................. 8 A90.................. 8 A-GP................... 9 CP-.................. 8 K90.................. 9 K0.................. 9 K0L................. 9 K9.................. 9 K0.................. 9 K0L................. 9 K.................. 9 K8.................. 8 K08.................. 9 K08.................. 9 K.................. 8 K.................. 9 K.................. 9 K8.................. 8 K87.................. K88.................. K9.................. 8 K977-INT.............. 9 K0-INT.............. 9 K0.................. 7 K9.................. 7 K00-0............. 7 K00-0.............. 7 K00-0GR............ 7 K00-BRIDGE-POS..... 7 K00-BRIDGE-POS..... 7 K00-TT0............. 7 K.................. 7 K800.................. 8 KT.................... 8 K880.................. 9 L7-XL-KK............. L7-XL-KK............. L7-XL-KK............. L7-XL-KK............. L7-XL-KK............. M-................. 9 NU8980-O-00-KK........ NU8980-O-00-KK-LP..... NU8980-O-00-KK........ NU8980-O-00-KK-LP..... NU8980-O-KK............ NU8980-O-KK-LP......... NU8980-O-SF00-KK...... NU8980-O-SF00-KK-LP... S88.................. 8 S9-TO............... 0 S7............... 0, 8 S88.................. 8 S8.................. 8 S8988.................. 8 S999-B-XL............. S999-B-XL............. S9997-B-XL............. SDRC.................. SDRCW................ U-RXL............... 9 U-X-KK............. U-X-KK-T-K-PED... U-X-KK-K-PED...... U-X-KK............. U-X-KK-T-K-PED... U-X-KK-K-PED...... U-X-KK............. U-X-KK-T-K-PED... U-X-KK-K-PED...... U-X-KK-T-K-PED... U-X-KK-K-PED...... U-X-KK-T-K-PED... U-X-KK-PED......... U78-O-T9-WI......... U78-O-WI............. U77-XL-TG-KK.......... 9 U779-RRL-T9-K....... U779-RRL-K........... U78-O-KK............. U0-X-K7............. U9-X-K7............. U9-XL-KK............ U7-XT-PED........... 8 U7-XT-PED-K7........ 8 U7-XT-PED........... 8 U7-XT-PED-K7........ 8 U7-XT-PED........... 8 U7-XT-PED-K7........ 8 U7-XT-PED........... 8 U7-XT-PED-K7........ 8 U7-XT-PED........... 8 U7-XT-PED-K7........ 8 U87-XT............... 7 U87-XT-T9-K........ 7 U87-XT-K............ 7 U87-XT............... 7 U87-XT-K............ 7 U87-XT............... 7 U87-XT-K............ 7 U000-O-T9-KL-KL..... U000-O-KL............ U000-O-KL-KL........ U8-O-KK............. U80................... U8-0GWRTR......... U8................... U89-O-00/00......... U89-O-/0........... U89-O-/00........... U80-O-TG-KK........... 9 U80................... U-O-T9............ 9 U-O-T9............ 9 U9-O................ U-X-QG............. U-X-80........... U-X-807........... U-XT-907.......... U7-X-80........... U7-X-8........... U7-XT-90.......... U7-XT-90.......... U70-XL............... U80-O................. 9 U80-O-T9............. 9 U80-XL................ 9 U80-XL-T9............ 9 U88-O................. U88-O-0GB............ U88-O-0GB............ U-O-00S........... 7 U-O-00S-0GR...... 7 U-O-00S........... 7 U-O-00S-GR...... 7 U7-O-00S........... 7 U7-O-00S-0GR...... 7 U7-O-00S........... 7 U7-O-00S-GR...... 7 U8-XTL-00-KK....... U70-O-00S-KK........ U8-RL-00-KK........ U8-RL-00-KK........ U88-X-KK-K-PED...... 9 U88-X-KK-K.......... 9 U88-X-KK-K-PED...... 9 U88-X-KK-K.......... 9 U88-X-KK-K-PED...... 9 U88-X-KK-K.......... 9 U88-X-KK-K-PED...... 9 U88-X-KK-K.......... 9 U88-X-KK-K-PED...... 9 U88-X-KK-K.......... 9 U90-X-KK-K-PED...... 9 U90-X-KK-K.......... 9 U90-X-KK-K-PED...... 9 U90-X-KK-K.......... 9 U90-X-KK-K-PED...... 9 U90-X-KK-K.......... 9 U90-X-KK-K-PED...... 9 U90-X-KK-K.......... 9 U90-X-KK-K-PED...... 9 U90-X-KK-K.......... 9 U9-O-00-KK......... U9-O-00-KK......... U7-RL-KK............ U7-RL-KK............ U7-RL-KK............ U7-RL-KK............ U7-RL-KK............ U7-RL............... U7-XL............... U787-RL-TG-KK.......... 7 U77-RL................ 8 U80-XL-KK............ U80-XL-KK............ U80-XL-KK............ U80-XL-KK............ U80-XL-KK............ U8-RXL.............. 0 U907-O................ 8 U907-O-K............. 8 U908-O................ 8 U90-RXL............... 8 U90-DL............... 0 U9-O................ 0 U9700-RRL.............. 0 U970-RXL.............. 0 UAP0-XL-KK.......... UC90-RL.............. 0 UC99-RL.............. 0 UC9-XL.............. 0 UC7-XL.............. 0 UC8-XL.............. 0 UC887-XL.............. 0 UC889-XL.............. 0 UC78-XL.............. 0 UC79-XL.............. 0 UC7-XL.............. 0 UQFB-00............... 9 UQFB-00-X............ 9 UQFB-............... 9 UQFB--X............ 9 UQFB-0............... 9 UQFB-0-X............ 9 UQFB-7............... 9 UQFB-7-X............ 9 UQFB-00............... 9 UQFB-00-X............ 9 UQFBH-00............. 9 UQFBH-............. 9 UQFBH-0............. 9 UQFBH-7............. 9 UQFBH-00............. 9 UQFP-00............... 9 UQFP-............... 9 UQFP-0............... 9 UQFP-7............... 9 UQFP-00............... 9 UQFPH-00............. 9 UQFPH-............. 9 UQFPH-0............. 9 UQFPH-7............. 9 UQFPH-00............. 9 UQFPH-M-00........... 9 UQFPH-M-........... 9 UQFPH-M-0........... 9 UQFPH-M-7........... 9 UQFPH-M-00........... 9 UQFP-M-00............ 9 UQFP-M-............ 9 UQFP-M-0............ 9 UQFP-M-7............ 9 UQFP-M-00............ 9 WS.................... Z709-AC............. Z7097-AC............. Z7098-AC............. Z7099-AC............. Z709-AC............. Z709-AC............. Z709-AC............. Z700-AC............. Z70-AC............. Z708-AC............. Z97799-AC............. 8

ADDITIONAL MILBANK PRODUCTS 9 Other quality products available from Milbank Commercial Pedestals Attractive Easy to install Secure Cost effective MISC. 8.8. phone 8.8.7 fax www.milbankmfg.com ComPed /09 (7.K) Un- Strut Your Stuff... In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... ADDITIONAL MILBANK PRODUCTS Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to www.milbankmfg.com to find additional product literature. 9

0 NOTES NOTES 0

NOTES NOTES

Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTATIVE MILBANK MFG. CO. PO Box 908 Kansas City, MO -008 Tel: 8-8- Fax: 8-8-7 Toll Free: 877-8- www.milbankmfg.com www.milbankmfg.com WAC / (.K)