UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

Similar documents
UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

320A Single Phase URD Meter Loop Installations

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

OVERHEAD SERVICE. Items to consider


D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SINGLE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS

AMENDMENT ELECTRIC SERVICE MANUAL 2014

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Service Requirements

WPS SERVICE MANUAL. Section Amp and Smaller - Common

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

UNDERGROUND SERVICES - SECONDARY

7 Single Family Service

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

Transmission & Distribution Glossary of Electrical Terms

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017

Installing or Rebuilding Your Electric Service

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

SECTION 300 OVERHEAD SERVICE

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

7. Residential Single-Family and Duplex Buildings (Dwellings)

2016 METER SERVICES SPECIFICATION GUIDE

COMMERCIAL QUICK REFERENCE

Service Requirements

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

U-18. Company furnishes and installs: 10. Service lateral and connectors. 11. Conduit package, Amperes.

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

CHAPTER V RESIDENTIAL WIRING

10 Commercial, Industrial, Agricultural Services

For Conduit Inspections

Meter Installation. -and- Padmount Transformer Guide

Contents. Obtaining Electric Service from Your Cooperative...1. Bonding Frames of Major Appliances...4. Voltage Drop...8. Drawings...

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

Pretest Module 24 Three-phase Service Entrance

Section 6 Electric Metering: Residential

Commercial Electric Policy

NEW SERVICE HANDBOOK COMMERCIAL & IRRIGATION SUPPLEMENT

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Three-Phase Pole Mounted Recloser

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

Engineering Rules and Regulations for Electric Service Platte-Clay Electric Cooperative, Inc.

INSTALL SERVICE- ENTRANCE SYSTEMS

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

Approved Contractor Construction e-guide Residential Commercial

Commercial & Industrial

Metering and Service Installation:

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

ELECTRIC SERVICE MANUAL

Marshfield Utilities Rules for Electric Service Installations. Table of Contents

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

RESIDENTIAL ELECTRIC PERMIT (REP) Village of Montpelier 211 N. Jonesville Street, PO Box 148 Montpelier, OH P:

TEMPORARY ELECTRICAL SERVICE

Residential Application for New Electric Service

METERING REQUIREMENTS

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

Table of Contents. Electrical Service Requirements. 1. General Requirements

Consider The Possibilities...

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

SECTION VII METERING INSTALLATIONS

Electric Service Rules

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house

Index Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles

1007 Elwell Court Palo Alto, CA 94303

CONTENTS BY CHAPTER. Chapter 2: COMPANY EQUIPMENT ON CUSTOMER PREMISES

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

Australian Wiring Instructions:

Electrical Maintenance and Repair: Introduction to Basic Electricity

Approved Meter Sockets and Cabinets

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

TEMPORARY SERVICE TABLE OF CONTENTS PUD SERVICE TERRITORY AND CONTACTS CHAPTER ONE - INTRODUCTION CHAPTER TWO - TEMPORARY OVERHEAD SERVICE

Customer Metering and Services Guide Revised: May 2017

SPECIAL SPECIFICATION 6894 Communication Cabinet

PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.

Air-Cooled Fluid Cooler

UV DISINFECTION UNIT MODEL 3G

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

Customer Requirements Clearance Requirements for Overhead Joint Utility Construction

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Electric Vehicle Pricing Plan Contractor Set-Up Guide

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

3.1 Overview of ATCO Electric s URD System Design

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ADDENDUM #2 TO BID # BID NUMBER: ISSUE DATE: Friday, January 18, 2019

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS TRAFFIC CONTROL STANDARDS

Electric Service Guide. Commercial & Industrial

Published 2018 RULES AND REGULATIONS FOR ELECTRIC SERVICE

Transcription:

UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement. Any other location requires conduit and a waterproof-dead front disconnect at meter. Meter base (furnished by Kosciusko REMC) by member s electrician. S.E. cable or conductors in conduit to member s service equipment size to be #2 aluminum or #2 copper for 100 amps., or #3/O copper or #4/O aluminum for 200 amps. Disconnect Switch Box (Type RH insulation required if aluminum conductors are used.) Two 5/8 x 8 copper ground rods spaced 6 apart. Attached to disconnect. Grade Level 18 6 conduit or Schedule 80 plastic conduit from meter base to 18 below grade. Locknuts and insulated bushings are needed at top and bottom if galvanized. Leave a 14 width from the center of conduit to allow for digging. Customer should supply conduit if underground service goes under a drive. A minimum of 2½ Schedule 40 conduit is required for 4/0 underground or wire, 350 MCM underground wire and 3 Schedule 40 conduit for 500 MCM underground wire. 200 AMP. to be in this conduit as Kosciusko REMC will install them when running the underground service. GROUNDING Two 5/8 x 8 ground rods are required. METER HEIGHT 14 GENERAL INFORMATION FOR UNDERGROUND SERVICES No meter base or entrance should be installed before a Kosciusko REMC engineer has checked the proposed location. Kosciusko REMC - Revised 2014

WIRING DIAGRAM IF DISCONNECT SWITCH IS IN THE BASEMENT Customer s Conduit KREMC Conduit WIRING DIAGRAM IF DISCONNECT SWITCH IS ON THE OPPOSITE SIDE OF THE WALL KREMC Conduit To disconnect switch box. KREMC Hot Legs Consumer Conductors Neutral

WIRING PROCEDURE IN LIEU OF USING METER PEDESTAL FOR UNDERGROUND ON 6X6 No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Kosciusko REMC will furnish the Underground Meter Base. The customer will furnish and install a structure (described below) for mounting the meter base and the weatherproof main disconnect panel. 8 x 6 x 6 treated posts with 2 x 6 treated cross members. Meter base furnished by Kosciusko REMC installed 3 minimum 100 or 200 amp weather proof main disconnect. 3-#2 aluminum for 100 amp, 3-#3/O copper or 3-#4/O aluminum for 200 amp. ground by customers electrician. Customer to install conduit or Schedule 80 plastic conduit from meter base to 18 below grade with locknuts and insulated bushing at top and bottom if galvanized. Leave a 14 width from the center of conduit to allow for digging. 2 ground rods 5/8 x 8 copper weld 5 3 Grade level No. 6 (minimum) copper ground wire from disconnect switch to ground rod. 14 6 200 AMP. GENERAL INFORMATION FOR UNDERGROUND SERVICES level. No wires to be in this conduit as Kosciusko REMC will install them when running the underground service. GROUNDING Two 5/8 x 8 ground rods are required. METER HEIGHT No meter base or entrance should be installed before a Kosciusko REMC engineer has checked the proposed location. Kosciusko REMC - Revised 2014

WIRING DIAGRAM FOR 6X6 UNDERGROUND To customer s disconnect KREMC Conduit KREMC Hot Legs Consumer Conductors Neutral

SERVICE WHERE BUILDING IS OVER 12 HIGH TO THE EAVES No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Insulator and wire by KREMC. Service cables or conduit 3-#4 aluminum for 60 amp 3-#2 aluminum for 100 amp 3-#3/O copper or 3-#4/O aluminum for 200 amp Weatherhead 12 high or higher if 18 Drip Loop (mark neutral with tape or strip 1 at end) Disconnect switch box must be directly through the wall or directly under meter in basement. Any other location requires conduit and a waterproof dead front disconnect at meter. Disconnect Switch Box Conduit or service cable straps as required. Busings and locknuts at all connections. Weatherproof bushing for cable #6 (minimum) copper ground wire from disconnect switch box to ground rod. (may be run inside of wall if desired) by Kosciusko REMC installed approximately Ground Clamps Two ground rods 6 apart. 5/8 x 8 copper weld Kosciusko REMC - Revised 2014

OVERHEAD SERVICE WHERE BUILDING IS OVER 12 HIGH TO THE EAVES Used for 100 AMP OVERHEAD SERVICE. #2 copper or aluminum service entrance cable from weatherhead to meter base, and from base to breaker or fuse panel. Weatherproof connector must be used in top of base. 200 Amp 2 Hub For 200 AMP OVERHEAD SERVICE with 2 conduit. #3/O copper or #4/O aluminum single conductors to be used from weatherhead to meter base and from meter base to breaker panel. Height or Weatherhead (Entrance Head) For all overhead installations, the weatherhead must be a minimum of 12 above the grade level, and higher if service drop crosses over a driveway. Driveways and roads require 16½ clearance. Overhead Services For all overhead services, a minimum of 18 of all conductors must extend out of the weatherhead. If all conductors are the same To Weatherhead WIRING DIAGRAMS To Weatherhead Conduit must be 1¼ or 2 Schedule 40 or steel. Ground from the disconnect switch. To Disconnect When disconnect switch box is under the meter base. When disconnect switch box is on the inside wall. KREMC Hot Legs Consumer Conductors Neutral

SERVICE WHERE BUILDING IS OVER 12 HIGH TO THE EAVES No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Insulator and wire by KREMC. Service cables or conduit 3-#4 aluminum for 60 amp 3-#2 aluminum for 100 amp 3-#3/O copper or 3-#4/O aluminum for 200 amp Weatherhead 12 high or higher if 18 Drip Loop (mark neutral with tape or strip 1 at end) Disconnect switch box must be directly through the wall or directly under meter in basement. Any other location requires conduit and a waterproof dead front disconnect at meter. Disconnect Switch Box Conduit or service cable straps as required. Busings and locknuts at all connections. Weatherproof bushing for cable #6 (minimum) copper ground wire from disconnect switch box to ground rod. (may be run inside of wall if desired) by Kosciusko REMC installed approximately Ground Clamps Two ground rods 6 apart. 5/8 x 8 copper weld Kosciusko REMC - Revised 2014

OVERHEAD SERVICE WHERE BUILDING IS UNDER 12 HIGH TO THE EAVES 100 Amp 2 Hub Used for 100 AMP OVERHEAD SERVICE. Where riser is used through the roof. Riser is 2 rigid conduit. #2 single conductors to be used from weatherhead to meter base and from base to fuse or breaker panel. 200 Amp 2 Hub For 200 AMP OVERHEAD SERVICE with 2 conduit. #3/O copper or #4/O aluminum single conductors to be used from weatherhead to meter base and from meter base to breaker panel. Height or Weatherhead (Entrance Head) For all overhead installations, the weatherhead must be a minimum of 12 above the grade level, and higher if service drop crosses over a driveway. Driveways and roads require 16½ clearance. Overhead Services For all overhead services, a minimum of 18 of all conductors must extend out of the weatherhead. If all conductors are the same Riser Height and 4 maximum. minimum Entrance Location Entrance should be installed before a Kosciusko REMC engineer has checked the proposed location. To Weatherhead WIRING DIAGRAMS To Weatherhead Conduit must be 2 steel. Ground from the disconnect switch box. To Disconnect When disconnect switch box is under the meter base. When disconnect switch box is on the inside wall. KREMC Hot Legs Consumer Conductors Neutral

OVERHEAD SERVICE ON METER POLE No meter base or entrance should be installed before a KREMC engineer has checked the proposed location. Mobile homes require an electrician to install four wires from pole to home. 30 treated pole (5 diameter at top). To be paid for by member. Weatherhead 18 Drip loop Service entrance cable, galvanized steel or Schedule 40 conduit may be used from meter base up to entrance head. Conduit or service cable straps as required. 3-#2 aluminum for 100 amp. 3-#3/O copper or 3-#4/O aluminum for 200 amp. Weatherproof busings and locknuts at all connections. above grade by customers electrician. Weatherproof 100, or 200 amp main disconnect. Number 6 (minimum) copper ground wire from disconnect switch to ground rod stapled to pole. Grade Level Ground Clamps Pole set 6 in ground. Two ground rods 6 apart. 5/8 x 8 copper weld Kosciusko REMC - Revised 2015

OVERHEAD SERVICE Used for 100 AMP OVERHEAD SERVICE. #2 copper or aluminum service entrance cable from weatherhead to meter base, and from base to breaker or fuse panel. Weatherproof connector must be used in top of base. 200 Amp 2 Hub For 200 AMP OVERHEAD SERVICE with 2 conduit. #3/O copper or #4/O aluminum single conductors to be used from weatherhead to meter base and from meter base to breaker panel. Overhead Services For all overhead services, a minimum of 18 of all conductors must extend out of the weatherhead. If all conductors are the same WIRING DIAGRAM To Weatherhead Conduit must be 1¼ or 2 Schedule 40 or steel. To Disconnect KREMC Hot Legs Consumer Conductors Neutral