AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

Similar documents
AC centrifugal fan. forward-curved, single-intake with housing (flange)

AC centrifugal module - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. backward curved

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC centrifugal fan - RadiCal

AC axial fan. sickled blades (S series) with full square nozzle

AC centrifugal fan. backward curved

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC axial fan. straight blades (A series) with full round nozzle

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan with housing (small flange)

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC axial fan. sickled blades (S series)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial fan. sickled blades (S series)

Energy-saving motors (ESM)

Energy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch

RadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Product Data Sheet DV5214 NU

Product Data Sheet 624 NR. The engineer's choice

MB Series AC Centrifugal Blowers

Product Data Sheet ACi 4420 HHR

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 632 NU-006

The new fan generation S-Force

AC axial fans, AC diagonal fans

Product Data Sheet 8314 HR-197

Motors- Basic principles. Expertise, performance, innovation

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet ACi 4420 MLR

Product Data Sheet 4184 N/17X. The engineer's choice

IBExU Institut für Sicherheitstechnik GmbH

Product Data Sheet 4184 NXHH

Product Data Sheet 3214 JH3-195

Listen to the difference. The AxiTop diffuser.

Product Data Sheet 8412 NHU-519

Product Data Sheet 614 N/2HH-169 The engineer's choice

4314/17T. Product Data Sheet INDEX

Product Data Sheet 8412 N/ The engineer's choice

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

AC axial fans S series, Ø 500

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

Brushless internal rotor motors ECI series. Drive solutions Industrial drive engineering

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

Product Data Sheet 4184 NXHH

product specification


AXIAL FAN WITH EXTERNAL ROTOR MOTOR

Lexium integrated drives

Cross-flow Fans. TFD/FFD Series

Lexium integrated drives

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Cross-Flow Fans. TF/FF Series

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Inside Front cover White

Pressure Transmitter JUMO dtrans p30 Type

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

AXIAL FANS Axis / Tubo OPERATION MANUAL

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

Technical Sales Guide # 040 YDFC 0 1 Page 2

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Product Data Sheet 4184 NGX

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

MegaBox Product-specific information

Performance. Sound Levels. Impellers. Motors. Accessories

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data

IN-LINE CENTRIFUGAL DUCT FANS VT Series

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

AL-RED. Stainless steel centrifugal pumps

MVSI. Technical features

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Wall mounted fan

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Standard valves to ISO Product range overview

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

PSC Thermal Solutions. size 273 x 220 x202mm

The World Leading Air-conditioning Company

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

Product Data Sheet 4414/2H

BRIZA 22 HYBRID HEATING & COOLING

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Torque Motors 3 W, 6 W, 10 W, 20 W

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Unobox units with backward curved centrifugal impellers

2CP Twin-impeller pumps

Transcription:

DE-AM7-65 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRB 59 Nominal data Type Motor DE-AM7-65 ME68-DF Phase ~ ~ Nominal voltage VAC Frequency Hz 6 Method of obtaining data fa ml Valid for approval/standard CE CE Speed (rpm) min - 8 Power consumption W 9 Current draw A.8.88 Capacitor µf Capacitor voltage VDB Capacitor standard S S Min. back pressure Pa Min. back pressure inho. Min. ambient temperature C -5-5 Max. ambient temperature C 5 5 ml = Max. load me = Max. efficiency fa = Free air cs = Customer specification ce = Customer equipment Subject to change Item no. 5-5-998 ENU Change 8855 Approved 6-5- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

DE-AM7-65 Technical description Weight Fan size Rotor surface Impeller material Housing material Motor suspension Direction of rotation Degree of protection Insulation class Moisture (F) / Environmental (H) protection class Max. permitted ambient temp. for motor (transport/storage) Min. permitted ambient temp. for motor (transport/storage) Installation position Condensation drainage holes Mode Motor bearing Touch current according to IEC 699 (measuring circuit Fig., TN system) Motor protection With cable Protection class Conformity with standards.5 kg mm Unpainted Sheet steel, galvanized Sheet steel, galvanized Motor mounted with brackets on one side Clockwise, viewed toward rotor IP; installation- and position-dependent "B" H - dry environment + 8 C - C Any None S Ball bearing <.75 ma Thermal overload protector (TOP) internally connected Axial I (with customer connection of protective earth) EN 65-; CE Item no. 5-5-998 ENU Change 8855 Approved 6-5- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

DE-AM7-65 Product drawing Cable PVC G.5 mm², x crimped splices Connection diagram U blue Z brown U black PE green/yellow Item no. 5-5-998 ENU Change 8855 Approved 6-5- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

DE-AM7-65 Curves: Air performance Hz Druck p f s[pa]für Rho=,kg/m^ 8 7 6 9 8 7 6 9 8 7 6 9 8 7 6 [cfm] [m^/h] 5 6,5,5,,5,,5,,5,,5,95,9 6 7 7,85,8,75,7,65 pfs_e[in HO],6,55,5,5,,5,,5,,5,,5 Measurement: LU-56- Air performance measured according to ISO 58 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 7 / sound pressure level measured at m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V f Hz n min - 89 57 P e W 9 6 8 I A.8.7.6.5 m /h 7 6 6 95 Pa 75 CFM 75 7 75 inho...8. U = Power supply f = Frequency n = Speed (rpm) P e = Power consumption I = Current draw = Air flow = Pressure increase Item no. 5-5-998 ENU Change 8855 Approved 6-5- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

DE-AM7-65 Curves: Air performance 6 Hz Druck p f s[pa]für Rho=,kg/m^ [cfm] 6 8 6 8 6 8 6 8 6 [m^/h] 5 6 6,85,8,75,7,65,6,55,5,5,,5,,5,,5,,5,95,9,85,8,75,7,65,6,55,5,5,,5,,5,,5,,5 7 pfs_e[in HO] Measurement: LU-565- Air performance measured according to ISO 58 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 7 / sound pressure level measured at m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V f Hz 6 6 6 6 n min - 8 685 95 P e W 8 7 59 I A.88.78.7.7 m /h 565 5 8 Pa 75 CFM 5 75 5 inho..8..5 U = Power supply f = Frequency n = Speed (rpm) P e = Power consumption I = Current draw = Air flow = Pressure increase Item no. 5-5-998 ENU Change 8855 Approved 6-5- Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com