ConceptpowerTM Modular kVA

Similar documents
TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS

PowerScale kva Technical Specifications

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

EFFEKTA Power Supplies

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical data sheets

PowerValue 11/31 T kva

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

PowerWave 33 Efficient power protection for today s IT and process-related work environments

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical data sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

D Series: UPS UPTO - 300KVA - Three / Three Phase

1.1 GENERAL CHARACTERISTICS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

POWERTRONIX QUASAR 5-40 KVA

TLE Series UPS 400/500 kw With eboost Technology

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TLE Series UPS 160/200/225/250 kw with eboost Technology

Master DIALOG INDUSTRY RANGE

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Power+ CLASSIC. 20/30 kva, 3x208 Vac

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Industrial PFC UPS System

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Three Phase UPS Systems Range: 10 to 500kVA

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Master Plus kva

Liebert. FP 50Z kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Master Plus kva

MKN-DSP SERIES - THREE PHASE

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

un I Jet ИБП ABB DPA Upscale ST S2 ( квт) - руководство по эксплуатации. Юниджет

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

TLE Series UPS 750/1000 kw With eboost Technology

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Est FlexiPower Mini UPS FPX Mini kVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

MGE TM Galaxy TM 7000 GFC

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

UPS Multi Sentry 10-20kVA

Marketing Management Team of Europe

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Green Power 2.0 MASTERYS GP

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

MASTERYS IP+ 10 to 80 kva

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Master MPS kva kva 3:1 3:3 VFI TYPE

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

MGE TM Galaxy TM 7000

Technical Specification SENTINEL PRO

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Transcription:

TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA Upgrade-Line 10-40kVA Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 1

TECHNICAL SPECIFICATIONS 10, 15, 20, 30 and 40 kva (three phase input and output) GENERAL DATA Output Rated kva 10 15 20 30 40 Output Factor 0.8 Topology Technology Construction Parallel Configuration Double Conversion AC-AC efficiency with batt. fully charged On-Line, Double Conversion, VFI Second Generation, Tansformerless Modular, Parallelable For redundancy and/or capacity: - Standard up to 10 modules - Without limitation on request 100%/75%/50%25% Linear Load (cos =0.8ind) % 95/95/94/89 95/95/94/90 95/95/94/90 96/96/94/91 96/96/94/91 100%/75%/50%/25% Linear Load (Resistive cos=1) % 94/94/92/89 94/94/92/89 94/94/92/89 94/94/93/90 95/95/93/90 100%/75%/50%/25% Non-linear Load (EN50091-1) % 93/93/91/88 93/93/91/88 93/93/91/88 93/93/92/89 93/93/92/89 Eco-Mode efficiency (load on by-pass) at 100% load % 98 98 98 98 98 Heat Dissipation With 100% Load (cos =0.8ind) W 380 500 670 870 1200 Heat Dissipation With 100% Load (Resistive cos =1) W 500 700 950 1250 1900 Heat Dissipation With 100% Non-linear Load (EN50091-1) W 650 900 1150 1650 2200 Airflow (25-30 C) with Non-linear Load (EN50091-1) m 3 /h 110 150 200 300 400 Audible Noise with 100% / 50% Load dba 55/49 57/49 57/49 59/51 59/51 Ambient Temperature for UPS C 0 40 Ambient Temperature for Batteries (recommended) C 20-25 Storage Temperature C -25 - +50 Storage Time at Ambient Temperature Cooling Relative Air-humidity Standards - Safety - Electromagnetic Compatibility - Performance Transportation Palette Accessibility Positioning Input and Output Cabling Dry Port (Volt-free contacts) Smart Port (RS 232) Max. 6 months Fan-assisted Max. 95% (non-condensing) EN 50091 - Part 1 (IEC 62040-1, IEC 60950) EN 50091 - Part 2 (IEC 62040 2) EN 50091 - Part 3 (IEC 62040 3) Provided with UPS Totally front accessibility for service and maintenance (no need for side, top or rear access) Min. 10cm rear space (required for fan) From front and bottom For remote signalling and automatic computer shutdown For monitoring and integration in network management EMERGENCY OFF (Normally closed) Input Terminals GEN-ON (Normally open) BATTERY TEMP. SENSOR UPS Module kg 10 20kVA = 40kg, 30kVA = 55kg ; 40kVA = 58kg UPS Module Size (WxHxD) mm 483 x 400 x 675 Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 2

RECTIFIER DATA Input Voltage V 3x380/220V+N, 3x400V/230V+N, 3x415/240V+N For Loads: <100%(-23%,+15%) Input Voltage Tolerance (ref to 3x400/230V) V (%) <80%(-30%,+15%) <60%(-40%,+15%) Input Frequency Hz 35 65 Input Factor 0.98 Input Current Form Sinewave (THDI 7 9% input voltage dependent) Inrush Current Limited by soft start Model kva 10 15 20 30 40 Input with rated output power and charged battery kw 8.5 12.7 17 25.3 34 Max. Input with rated output power and discharged battery kw 12 19 25 37 48 BATTERY DATA Charger Current (standard) 15 A Charging Curve IU (DIN 41773) Temperature Controlled Charger Yes Charger Ripple Ripple-free battery charging Test Automatic and periodic (adjustable) Lead-acid, Maintenance-free and NiCd Variable Number of 12V Blocks 30-50 blocks for 10-20kVA, 40-50 blocks for 30kVA and 50blocks for 40kVA INVERTER DATA Output Rated KVA 10 15 20 30 40 Output Rated Voltage V 3x380/220V, 3x400/230V, 3x415/240V Output Factor 0.8 Output Voltage Tolerance - Static % + / - 1 - Load Jump (0-100%, 100-0%) % + / - 4 - Distortion With Linear Load % + / - 1 - Distortion With Non-linear Load % + / - 3 (according to EN 50091-1) Recovery Time After Load Jump (0-100%, 100-0%) msec 20 Permissible Unbalanced Load % 100% (all 3 phases regulated independently) Output waveform sinewave Output Frequency Hz 50 or 60 Output Frequency Tolerance - Free-running, Quartz Oscillator % + / - 0.1 - Synchronized with mains (adjustable) % + / - 4 Overload Capability % 125 for 10min. and 150 for 1min. Crest - Factor 3 : 1 Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 3

POWER MANAGEMENT DISPLAY (PMD) The user-friendly PMD consists of three parts the MIMIC DIAGRAM, CONTROL KEYS and LCD that provides the necessary monitoring information about the UPS. MIMIC DIAGRAM The mimic diagram serves to give the general status of the UPS. The LED-indicators show the power flow status and in the event of mains failure or load transfer from inverter to bypass and vice-versa the corresponding LED-indicators will change colour from green (normal) to red (warning). The LED s LINE 1 (rectifier) and LINE 2 (bypass) indicate the availability of the mains power supply. The LED s INVERTER and BYPASS if green indicate which of the two are supplying power to the critical load. When the LED-indicator BATTERY is lit it means that the battery due to mains failure is supplying the load. The LED-indicator ALARM is a visual indication of any internal or external alarm condition. At the same time the audible alarm will be activated. PUSHBUTTONS The pushbuttons serve to manage the UPS by performing commands. The 2xON/OFF pushbuttons serve to start-up or shutdown the UPS if pressed simultaneously. The pushbuttons UP and DOWN allow working through the PMD-menu. The RESET pushbutton serves to cancel the audible alarm in the event of a disturbance. If the alarm condition was only transient the LED-indicator ALARM would also extinguish otherwise it will remain on (red). DISPLAY The 2 x 20 character LCD simplifies the communication with the UPS. The menu driven LCD enables the access to the EVENT REGISTER, or to monitor the input and output U, I, f, P, Time and other Measurement s, to perform commands like start-up and shut-down of INVERTER or load transfer from INVERTER to BYPASS and vice-versa and finally it serves for the DIAGNOSIS (SERVICE MODE) for adjustments and testing (for more details see the USER MANUAL of conceptpower TM ). concept power TM ON/OFF LINE 2 BY PASS BATTERY ALARM ON/OFF LINE 1 INV RESET ENTER Management Display (PMD) of conceptpower OPTIONALS Extended Autonomies Optional Charger Remote Signalling Panel (RSP) Parallel Configuration (standard) Wavemon Software SNMP - Adapter Input or Output Isolation Transformer Customized UPS- and s In matching battery frames CBAT-30C, CBAT-M, and CBAT- 30GU For longer autonomies For UPS-Status indication A number of units may be paralleled for redundancy or capacity upgrade For automatic shut-down and monitoring For network management and remote monitoring For special voltages or for galvanic isolation On request (for OEM-Projects only) Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 4

MECHANICAL CHARACTERISTICS Classic Line MODEL kva 10 15 20 30 40 Dimensions (WxHxD) mm 550 x 1400 x 750 550 x 1800 x 750 Protection Degree IP 20 Ventilation Fan assisted Colour RAL 9002 Foot Print m 2 0.41 Output of one Classic Line UPS 40 kva Dimensions of Concept (Depth 750mm) Classic : CUPS-30C 10 0 CUPS-30C 200 10 10 40 x 7Ah CUPS-30C 300 10 16 (2x30) x 7Ah CUPS-30C 350 10 24 (2x40) x 7Ah CUPS-30C 400 10 40 (3x40) x 7Ah CUPS-30C 500 1400mm 15 0 CUPS-30C 205 15 10 (2x30) x 7Ah CUPS-30C 355 15 14 (2x40) x 7Ah CUPS-30C 405 15 24 (3x40) x 7Ah CUPS-30C 505 20 0 CUPS-30C 205 20 10 (2x40) x 7Ah CUPS-30C 405 20 16 (3x40) x 7Ah CUPS-30C 505 550 mm 30 0 CUPS-30C 210 30 10 (3x40) x 7Ah CUPS-30C 510 CBAT-30C In the CBAT-30C to 90 x 24Ah / 28Ah may be fitted. The maximum achievable autonomy with one additional CBAT-30C are: 1400mm UPS + 10 132 90x24Ah CBAT-30C 1160 15 78 90x24Ah CBAT-30C 1160 20 53 90x24Ah CBAT-30C 1160 30 32 90x24Ah CBAT-30C 1160 550 mm 580 mm Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 5

Dimensions of Concept Classic-Line (Depth 750mm) for 40kVA Classic-Line : CUPS-40C 40 0 CUPS-40C 280 40 8 (3x50) x 7Ah CUPS-40C 660 40 12 (4x50) x 7Ah CUPS-40C 790 1800 mm 550 mm CBAT-M In the CBAT-M up to 100 x 24Ah / 28Ah may be fitted. The maximum achievable autonomy with one additional CBAT-M are: 1800 mm UPS+ 40 25 (2x50)x24Ah CBAT-M 1370 40 42 (3x50)x24Ah 2xCBAT-M 2010 550 mm 580 mm Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 6

Block Diagram Classic Line STANDARD VERSION (SINGLE INPUT FEED) VERSION ON REQUEST (DUAL INPUT FEED) Fuse A Cable A MAINS (3x380V/220V, 3x400/230V,3x415/240 V) Fuse B Cable B Fuse C Cable C MAINS (3x380V/220V, 3x400/230V,3x415/240V) Fuse E F4 UPS module 1 Fuse E F4 UPS module 1 IA2 IA2 Classic Mainten. Bypass Classic Mainten. Bypass Load Load Cable Sections and Fuse Ratings recommended by European standards. Alternatively, local standards to be respected STANDARD VERSION (SINGLE FEED INPUT) Fuse A (Agl/CB) Cable A Fuse E (IEC 60950-1:2001) (IEC 60950-1:2001) +/N/- +/N/- 10 3x20 5x2.5 5x2.5 3x32A 3x4 15 3x25 5x4 5x4 3x63A 3x10 20 3x40 5x6 5x6 3x63A 3x10 30 3x63 5x10 5x10 3x80A 3x16 40 3x80 5x25 5x25 3x100A 3x25 VERSION ON REQUEST (DUAL FEED INPUT) Fuse B (Agl/CB) Cable B (IEC 60950-1:2001) Fuse C (Agl/CB) Cable C (IEC 60950-1:2001) (IEC 60950-1:2001) Fuse E +/N/- +/N/- 10 3x20 5x2.5 3x20 4x2.5 5x2.5 3x32A 3x4 15 3x25 5x4 3x25 4x4 5x4 3x63A 3x10 20 3x40 5x6 3x40 4x6 5x6 3x63A 3x10 30 3x63 5x10 3x63 4x10 5x10 3x80A 3x16 40 3x80 5x25 3x80 4x25 5x25 3x100A 3x25 The Classic Line UPS s may be paralleled for power capacity upgrade or redundancy. Every standard conceptpower TM UPS is provided with the parallel option and therefore no upgrading on site is necessary. UPS 1 UPS 2 UPS n Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 7

MECHANICAL CHARACTERISTICS Gemini Line (not available for 40kVA module) MODEL KVA 2x10 2x15 2x20 2x30 Dimensions (WxHxD) mm 550 x 1800 x 750 Protection Degree IP 20 Ventilation Fan assisted Colour RAL 9002 Foot Print m2 0.41 Output of one Gemini Line UPS 60 kva Dimensions of Concept (depth 750mm) CUPS-30G CBAT-30GU 10 + 10 0 CUPS-30G 265 10 + 10 7 + 7 (2x30)x7Ah CUPS-30G 415 10 + 10 10 + 10 (2x40)x7Ah CUPS-30G 465 10 + 10 16 + 16 2x(2x30)x7Ah CUPS-30G 575 15 + 15 0 CUPS-30G 280 1800 15 + 15 5 + 5 (2x30)x7Ah CUPS-30G 430 15 + 15 7 + 7 (2x40)x7Ah CUPS-30G 480 15 + 15 10 + 10 2x(2x30)x7Ah CUPS-30G 580 20 + 20 0 CUPS-30G 280 20 + 20 5 + 5 (2x40)x7Ah CUPS-30G 480 20 + 20 7 + 7 2x(2x30)x7Ah CUPS-30G 580 30 + 30 0 CUPS-30G 290 30 + 30 10 (3x40)x7Ah *) CUPS-30G 590 550 mm 580 mm *) This battery is common for the 2 modules of 30kVA, Two separate batteries (5+5)min. are available on request. In the battery frame CBAT-30GU up to 120 x 24Ah/28Ah batteries respectively may be fitted allowing the maximum autonomies as shown in the table on the right. 10 + 10 90 + 90 120x24Ah CBAT- 30GU 15 + 15 55 + 55 120x24Ah CBAT- 30GU UPS + 1535 1550 20 + 20 38 + 38 120x24Ah CBAT- 30GU 1550 30 + 30 46 120x24Ah*) CBAT- 30GU 1560 *) This battery is common for the 2 modules of 30kVA, Two separate batteries (23+23)min. are available on request. Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 8

Block Diagram Gemini Line STANDARD VERSION (SINGLE INPUT FEED) VERSION ON REQUEST (DOUBLE INPUT FEED) Fuse A Cable A MAINS (3x380V/220V, 3x400/230V,3x415/240V Fuse B Cable B Fuse C Cable C MAINS (3x380V/220V, 3x400/230V,3x415/240 F1 F2 F1 F2 Fuse E F4 UPS module 1 F5 UPS module 2 Fuse E F4 UPS module 1 F5 UPS module 2 IA2-1 IA2-2 IA2-1 IA2-2 Gemini Main.Bypass IA1 Gemini Main.Bypass IA1 Load Load Cable Sections and Fuse Ratings recommended by European standards. Alternatively, local standards to be respected STANDARD VERSION (SINGLE FEED INPUT) Fuse A (Agl/CB) Cable A Fuse E (IEC 60950-1:2001) (IEC 60950-1:2001) +/N/- +/N/- 10 3x40 5x6 5x6 3x32A 3x4 10+10 3x40 5x6 5x6 3x63A 3x10* 15 3x63 5x10 5x10 3x63A 3x10 15+15 3x63 5x10 5x10 3x100A* 3x25* 20 3x80 5x16 5x16 3x63A 3x10 20+20 3x80 5x16 5x16 3x125A* 3x35* 30 3x100 5x25 5x25 3x80A 3x16 30+30 3x100 5x25 5x25 3x125A* 3x35* VERSION ON REQUEST (DUAL FEED INPUT) Fuse B (Agl/CB) Cable B Cable C Fuse E Fuse C (Agl/CB) (IEC 60950-1:2001) (IEC 60950-1:2001) (IEC 60950-1:2001) +/N/- +/N/- 10 3x40 5x6 3x40 4x6 5x6 3x32A 3x4 10+10 3x40 5x6 3x40 4x6 5x6 3x63A* 3x10* 15 3x63 5x10 3x63 4x10 5x10 3x63A 3x10 15+15 3x63 5x10 3x63 4x10 5x10 3x100A* 3x25* 20 3x80 5x16 3x80 4x16 5x16 3x63A 3x10 20+20 3x80 5x16 3x80 4x16 5x16 3x125A* 3x35* 30 3x100 5x25 3x100 4x25 5x25 3x80A 3x16 30+30 3x100 5x25 3x100 4x25 5x25 3x125A* 3x35* *only valid for common battery use Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 9

MECHANICAL CHARACTERISTICS Upgrade Line MODEL KVA 3x10 3x15 3x20 3x30 3x40 Dimensions (WxHxD) mm 550 x 1800 x 750 Protection Degree IP 20 Ventilation Fan assisted Colour RAL 9002 Foot Print m 2 0.41 Output of one Upgrade Line UPS 90kVA or 120 kva Dimensions of Concept (depth 750mm) CUPS-30U CBAT-30GU 10 0 CUPS-30U 170 10 + 10 0 CUPS-30U 215 10 + 10 + 10 0 CUPS-30U 260 15 0 CUPS-30U 175 1800 15 + 15 0 CUPS-30U 225 15 + 15 + 15 0 CUPS-30U 275 20 0 CUPS-30U 175 20 + 20 0 CUPS-30U 225 20 + 20 + 20 0 CUPS-30U 275 30 0 CUPS-30U 180 30 + 30 0 CUPS-30U 235 30 + 30 + 30 0 CUPS-30U 290 550 mm 580 mm UPS + 10+10+10 46+46+46 120x24Ah CBAT-30GU 1530 15+15+15 28+28+28 120x24Ah CBAT-30GU 1545 20+20+20 20+20+20 120x24Ah CBAT-30GU 1545 30+30+30 11+11+11 120x24Ah CBAT-30GU 1560 In the battery frame CBAT-30GU up to 120 x 24Ah/28Ah batteries respectively may be fitted allowing the maximum autonomies as shown in the table on the right. Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 10

Dimensions of Concept (depth 750mm) for 40kVA UPS-40U CBAT-30GU (for separate battery) CBAT-M (for common battery) 40 0 CUPS-40U 190 40 + 40 0 CUPS-40U 248 40 + 40 + 40 0 CUPS-40U 306 1800 550 mm 580 mm UPS + 40+40+40 11+11+11 (3x50)x24Ah 2x CBAT-GU 2032 In the battery frame CBAT-GU up to 120 x 24Ah/28Ah batteries respectively may be fitted allowing the maximum autonomies as shown in the above table. Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 11

Block Diagram Upgrade Line STANDARD VERSION (SINGLE INPUT FEED) VERSION ON REQUEST (DUAL INPUT FEED) Fuse A Cable A MAINS (3x380V/220V, 3x400/230V,3x415/240V Fuse B Cable B Fuse C Cable C MAINS (3x380V/220V, 3x400/230V,3x415/240V Fuse E UPS module 1 UPS module 2 UPS module 3 Fuse E UPS module 1 UPS module 2 UPS module 3 IA2-1 IA2-2 IA2-3 IA2-1 IA2-2 IA2-3 Upgrade Maintenance Bypass IA1 Upgrade Maintenance Bypass IA1 Load Load Cable Sections and Fuse Ratings recommended by European standards. Alternatively, local standards to be respected STANDARD VERSION (SINGLE FEED INPUT) Cable A Fuse E Fuse A (Agl/CB) (IEC 60950-1:2001) (IEC 60950-1:2001) +/N/- +/N/- 10 3x63 5x10 5x10 3x32A 3x4 10+10 3x63 5x10 5x10 3x63A* 3x10* 10+10+10 3x63 5x10 5x10 3x100A* 3x25* 15 3x100 5x25 5x25 3x63A 3x10 15+15 3x100 5x25 5x25 3x100A* 3x25* 15+15+15 3x100 5x25 5x25 3x125A* 3x35* 20 3x100 5x25 5x25 3x63A 3x10 20+20 3x100 5x25 5x25 3x125A* 3x35* 20+20+20 3x100 5x25 5x25 3x160A* 3x50* 30 3x125 5x35 5x35 3x80A 3x16 30+30 3x125 5x35 5x35 3x125A* 3x35* 30+30+30 3x125 5x35 5x35 3x200A* 3x70* 40 3x200 5x70 5x70 3x100A 3x25 40+40 3x200 5x70 5x70 3x160A* 3x50* 40+40+40 3x200 5x70 5x70 3x250A* 3x120* * only valid for common battery use Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 12

VERSION ON REQUEST (DUAL FEED INPUT) Fuse B Cable B Fuse C Cable C Fuse E (Agl/CB) (IEC 60950-1:2001) (Agl/CB) (IEC 60950-1:2001) (IEC 60950-1:2001) +/N/- +/N/- 10 3x63 5x10 3x63 4x10 5x10 3x32A 3x4 10+10 3x63 5x10 3x63 4x10 5x10 3x63A* 3x10* 10+10+10 3x63 5x10 3x63 4x10 5x10 3x100A* 3x25* 15 3x100 5x25 3x100 4x25 5x25 3x63A 3x10 15+15 3x100 5x25 3x100 4x25 5x25 3x100A* 3x25* 15+15+15 3x100 5x25 3x100 4x25 5x25 3x125A* 3x35* 20 3x100 5x25 3x100 4x25 5x25 3x63A 3x10 20+20 3x100 5x25 3x100 4x25 5x25 3x125A* 3x35* 20+20+20 3x100 5x25 3x100 4x25 5x25 3x160A* 3x50* 30 3x125 5x35 3x125 4x35 5x35 3x80A 3x16 30+30 3x125 5x35 3x125 4x35 5x35 3x125A* 3x35* 30+30+30 3x125 5x35 3x125 4x35 5x35 3x200A* 3x70* 40 3x200 5x70 3x200 4x70 5x70 3x100A 3x25 40+40 3x200 5x70 3x200 4x70 5x70 3x160A* 3x50* 40+40+40 3x200 5x70 3x200 4x70 5x70 3x250A* 3x120* *only valid for common battery use Newave_TDS_CPC-CPG-CPU_10K_40K_GB_V1.0.DOC Page 13