EAS822 (Contrac) Power Electronic Unit

Similar documents
RSD100 (Contrac) Electrical Linear Actuator

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Electrical Linear Actuator RSD10 / RSD20 (Contrac)

Contrac RSD 200. Electrical Linear Actuator for Continuous Control Rated Force 200 kn 10/ EN. Application. Positioning:

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

FICHA TÉCNICA DE PRODUTO

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Field IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator

Moving Coil Indicators with direct temperature sensor input

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Shut-off valves and accessories for pressure measuring instruments

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

FPD220 meter 2 di Dual-chamber orifice fitting with double isolation

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

RHD500, RHD800 (Contrac) Electrical Part-Turn Actuators. For continuous positioning, rated torque 500 / 800 Nm (400 / 600 lbf-ft)

Field instrumentation. Electropneumatic units. as I/P converters and positioners

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring

RSD10, RSD20 (Contrac) Electric Linear Actuators. For continuous positioning, rated force 10 / 20 kn (2250 / 4500 lbf)

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Thermal overload relay TF140DU and TF140DU-V1000

Service Fieldbus Engineering and Consulting

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Thermal overload relay TF65 and TF96

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Mini contactors B6, BC6 with 3 pole

ABB i-bus KNX DG/S x DALI-Gateway Basic

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Electrical Linear Actuators for Continuous Modulating Control LME620AI / LME620AN (Contrac)

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Manual motor starters Overview and benefits

Series AV1 / 2 / 4 Characterizable pneumatic positioners

Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Linear Actuators Contrac LME 620 AI / LME 620 AN. Rated Force 4 kn With Integrated Electronics or for Separate Field Housing.

ABB measurement & analytics data sheet. Model M26 Manifold line for 266 pressure transmitters

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Mini Contactors Applications and Segments

EC Gold Series Synchronous permanent magnet motor

Series AV1 / 2 / 3 / 4 Characterizable pneumatic positioners

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

Thermal Overload Relays

Surge arrester POLIM-H.. ND

EMPAC Metal enclosed capacitor bank for wind applications

Electrical Part Turn Actuators for Continuous Modulating Control PME120AI / PME120AN (Contrac)

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Intelligent electrical actuators for process automation applications System description

Where flows of liquid, vaporous or gaseous media have to be controlled or shut off

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

Manual motor starter magnetic only MO325

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

PQC - STATCON The ultra fast Power Quality Compensator

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

FICHA TÉCNICA DE PRODUTO

Navigator 550 Sodium wet-section

Unit C of the Scholven Power Plant Automated with System 800xA

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

Emergency stops Award winning design

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Surge arrester POLIM-H..SD

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Selective main circuit breakers S 750 series Technical Data

Control Valve From high-temperature/ high-pressure plant to process plant

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Additional Information. Measurement made easy

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Traction systems for Light Rail Vehicles Selected references

Operational Experience with Startup Optimization for Steam Boilers. E.ON s Staudinger, Heyden, Ingolstadt und Zolling Power Plants

ZX-Family Gas-insulated medium voltage switchgear

When grids get smart ABB your partner for developing Smart Grids solutions

TriLine PowerModules Overview with Planing Examples

Electrical Part Turn Actuators for Continuous Modulating Control RHD8000 / RHD16000 (Contrac) Rated Torque 8000 Nm / Nm

Manual motor starter MS132

Transcription:

Contents Data Sheet Rev. A EAS822 (Contrac) Power Electronic Unit For continuous control of Contrac actuators PME120 AN and LME620 AN Microprocessor-controlled power electronic unit with integrated frequency converter Voltage supply 115 V AC or 230 V AC Conventional signal interface (0 / 4 20 ma / 24 V) Digital communication via RS232 and HART Additional functions such as process controller, maintenance computer, programmable characteristics Torque and speed variation Continuous positioning Simple installation and commissioning Simple configuration and parameter setting via graphical user interface High response sensitivity Reliable for short positioning times Rack installation, protection class IP 20

Data Sheet Power Electronic Unit EAS822 (Contrac) For continuous control of Contrac actuators Power Electronic Unit EAS822 (Contrac) Contents 1 Concept...3 2 Technical data...3 2.1 General information...3 3 Electrical connection...4 4 Dimensions...5 4.1 Power Electronic Unit...5 5 Ordering information...7 2

Wechsel ein-auf zweispaltig Power Electronic Unit EAS822 (Contrac) 1 Concept Wechsel ein-auf zweispaltig Compact actuator for the operation of final control elements with preferably 90 rotary movement such as flaps, cocks, etc. The torque is transferred via a lever / linkage bar assembly or the actuator is directly coupled to the cock flange. A special power electronic unit controls the actuator. The electronic unit serves as the interface between actuator and control system. During continuous positioning the power electronic unit varies the motor torque steplessly until the actuator force and the restoring process forces are balanced. High response sensitivity and high positioning accuracy with short positioning time ensure an excellent control quality and a long actuator life. Important The ANSI information appears in parentheses after the SIinformation. 2 Technical data Supply voltage Power External fuse for power electronic unit External fuse Anti-condensation heater Analog input; setpoint Analog output; actual value 3 binary inputs BE 1 BE 3 (DI 1 DI 3) 3 binary outputs BA 1... BA 3 (DO 1 DO 3) 115 V AC (94 130 V) or 230 V AC (190 260 V); 47.5 63 Hz; 1 Ph 50 W / 160 W 16 A; time-lag 2... 6 A; medium time-lag 0 / 4 20 ma 0 / 4 20 ma, galvanically isolated Binary 0: -3 5 V or open, galvanically separated Binary 1: 12 35 V, galvanically separated Potential free relay contact, max. 60 V DC / 25 V AC, 150 ma Digital communication RS232 for commissioning and service, optionally FSK / HART Default settings Behavior in 0 / 100 % end position: set point function: set point input: function selection: actual value: digital input: Voltage output U V Transmitter (optional) Individual settings 2.1 General information Protection Class IP 20 Humidity Rack inlet temperature Mounting position digital output: Hold with rated torque / end positions linear, set point = position value 4 20 ma positioner, parameter: setpoint 4 20 ma BE 1 (DI 1) M / A selection; BE 2 / 3 (DI 2 / 3) manual intervention +/ - BA 1 (DO 1) ready for operation; BA 2 / 3 (DO 2 / 3) end position signal 0 / 100 % 24 V, 15 ma, galvanically isolated ; e.g., for scanning external contacts Supply for 2-wire transmitter with activated process controller in Contrac See data sheet 10/68-2.40 or upon request 75 % annual average (condensation not permitted) 0... 45 C (32... 110 F) Vertical, connections on right-hand side Vibration stress 2... 9 Hz: max. deflection: 3 mm (0.12 inch) 9... 200 Hz: acceleration: 1 g Coating Electrical connection Weight 2-layer component epoxy (RAL 9005, black) Power Electronic Unit EAS822 (Contrac) Mains supply via terminals; others via pluggable terminals Approx. 9 kg (20 lbs) 3

Power Electronic Unit EAS822 (Contrac) 3 Electrical connection Important The electrical connection is provided by a plug on the actuator and the terminals on the electronic unit. Fig. 1 4

Power Electronic Unit EAS822 (Contrac) 4 Dimensions 4.1 Power Electronic Unit 283 7 8 100,5 40 40 17 20 62 313 28 91 19,5 9 40 3 20 21 292 255 15 34 61 20 102 Fig. 2: Dimensions in mm 79 20 135 153 M00213 EAS822 Terminals For cable Ø Terminals for wire gauge Mains cable 13 mm max. 4 mm 2 Signal cable (DCS) 8 mm max. 1.5 mm 2 Transmitter 8 mm max. 1.5 mm 2 Motor cable 13 mm max. 4 mm 2 Sensor cable 8 mm max. 1.5 mm 2 5

Power Electronic Unit EAS822 (Contrac) 11.14 0.28 0.31 3.96 1.57 1.57 0.67 0.79 2.44 12.32 1.10 3.58 0.78 0.35 1.57 0.12 0.79 0.83 11.5 10.04 0.59 1.34 2.4 0.79 4.02 Fig. 3: Dimensions in inches 3.11 0.79 5.51 6.02 M00213 EAS822 Terminals For cable Ø Terminals for wire gauge Mains cable 0.51 inch max. 12 AWG Signal cable (DCS) 0.31 inch max. 16 AWG Transmitter 0.31 inch max. 16 AWG Motor cable 0.51 inch max. 12 AWG Sensor cable 0.31 inch max. 16 AWG 6

Power Electronic Unit EAS822 (Contrac) Order information 5 Ordering information Electronic Unit Variant digit No. 1-8 9 10 11 12 Code EAS822 Catalog No. V68822A- Suitable for Part-Turn Actuator PME120-AN 0 0 0 1 Linear Actuator LME620-AN 0 0 0 2 for PME120-AN adjusted to: Nm (ft-lbs) /s s/90 100 80 4.5 20 310 100 80 3.0 30 311 100 80 1.5 60 312 50 40 3.0 30 313 50 40 1.5 60 314 for LME620-AN adjusted to: kn (lbs) mm/s s/60 mm (s/in) 4 900 2.0 30 12.7 320 4 900 1.0 60 25.4 321 4 900 0.5 120 50.8 322 Special features of Electronic Unit Select at least one feature per group Supply voltage 230 V AC 1 Ph 380 115 V AC 1 Ph 381 Frequency 50 Hz 382 60 Hz 383 Digital communication RS 232 384 RS 232 + HART 385 Ambient temperature range -10... 65 C (15... 150 F) 344 of actuator -25... 55 C (-15... 130 F) 343-1... 85 C (30... 185 F) (only for PME120-AN, max. 2 /s) 349 Settings of electronic unit Standard settings (see techn. data) 390 Customer specific settings (see data sheet 10/68-2.40 EN) 391 Additional ordering information Code Anti-condensation heater in actuator "ON" 359 Identification on data label (alphanumeric, max. 32 characters) 295 Data label with US units 253 F. No. of associated actuator on data label of electronic unit 297 Factory certificate 2.1 acc. to EN 10204 291 Certificate B acc. to EN 10204 292 Operating instruction (specify total quantity required, 1 copy without extra charge) German (no specification for 1 copy) Z1D English (always state Code-No.) Z1E 7

Contact us ABB Ltd. Process Automation Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Phone: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. Process Automation 125 E. County Line Road Warminster, PA 18974 USA Phone: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2010 ABB All rights reserved Rev. A 12.2010 3KXE181004R1001 ABB Automation Products GmbH Process Automation Schillerstr. 72 32425 Minden Germany Phone: +49 551 905-534 Fax: +49 551 905-555 www.abb.com