Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Similar documents
2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

C -5 to +55 (0.8 to 1.1Uc) Permissible o

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

LR9 F OVERLOAD RELAYS

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Pendant control stations 6

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

References 4 Fuse carriers

DATA SHEET LC-D CONTACTORS

3 - Protection components Motor circuit-breakers

TeSys D Overload Relays

CI-TI Contactors and motor starters Types CI 61 - CI 98

Motor control The essential guide

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Contactor Types CI 61-98

CI-TI Contactors and Motor Starters Type CI 6-50

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Protection Equipment

Modular contactors and relays

Protection components

ASL09..S 3-pole Contactors - Spring Terminals

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Micro Contactor MA Series

Short form catalogue. Motor protection & control

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

TAE pole Contactors

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Essential equipment for all your requirements

Protection Equipment. 5/2 Introduction

Characteristics TeSys contactors 0 Model d

4 - Miniature controls

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AE 9... AE 40 Contactors NE... Contactor Relays

Low Voltage. TeSys B contactors. Variable composition contactors, new design. Catalogue

Bulletin 100-D IEC Contactors

Industrial contactors CTX-1

Enclosed motor starters

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

Ktec Contactors and thermal overloads

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Quality Products, Prompt Service, Trustful Relationships.

Manual Motor Starters. Meta-MEC

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

AF series contactors (9 2650)

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Meta Solution. Contactors and Overload relays

ICG Switchgear Price List 2009

AF40... AF96 3-pole contactors Technical data

Meta Solution. Contactors and Overload relays

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Low voltage switch gear

Command and signalling E 250, E 259 selection table

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Accessories for Contactors and Contactor Relays

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Low voltage moulded case circuit breaker EB2

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

SIRIUS 3RU2 Thermal Overload Relays

KD LV Motor Protection Relay

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

AF series contactors (9 2650)

Mini Contactors CI 4-

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Pendant control stations

AF09... AF96 3-pole contactors Accessory fitting details

Thermal overload relays Type TA Class 10

References Contactors 0 Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled Controlcircuit:a.c.ord.c.

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

cor Long Run Experience

Partnership that you can trust. LV Switchgear Motor Control Products.

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Description. Positive safety relays

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Industrial Contactors CTX 3 3P 185A - 800A

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Safety Limit Switch

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Bimetal Overload Relays 3UA and 3UC

Transcription:

d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary Complete with code 50/60 Hz in category AC-3 current contacts indicating control (θ 55 C) in AC-3 circuit voltage (2) up to Fixing, 220V 380V 660V 0V cabling () 230V 400V 45V 0V 500V 690V kw kw kw kw kw kw A kg 2.2 4 4 4 5.5 5.5 9 LC-D0900ii (3) 0.320 LC-D090ii 0.320 LC-D090ii 0.320 3 5.5 5.5 5.5 7.5 7.5 2 LC-D200ii (3) 0.320 LC-D20ii 0.320 LC-D20ii 0.320 LC-D090ii 4 7.5 9 9 0 0 8 LC-D800ii (3) 0.320 LC-D80ii 0.350 LC-D80ii 0.350 5.5 5 5 25 LC-D2500ii (3) 0.320 LC-D250ii 0.505 LC-D250ii 0.505 7.5 5 5 5 8.5 8.5 32 LC-D3200ii (3) 0.320 LC-D320ii 0.525 LC-D250ii LC-D320ii 0.525 8.5 22 22 22 30 40 LC-D40ii.50 5 22 25 30 30 33 50 LC-D50ii.50 8.5 30 37 37 37 37 65 LC-D65ii.50 22 37 45 45 55 45 80 LC-D80ii.500 25 45 45 45 55 45 95 (4) LC-D95ii.500 Note : Add-on auxiliary contact blocks and modules : see pages /32 to /43. LC-D95ii () For LC-D09 to D32 : clip-on mounting onto 35 mm " rail AM-DP. For LC-D40 to D95 : clip-on mounting onto 35 mm or 75 mm " rail AM-DL. Power terminals : LC-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c 24 42 48 0 220/230 230 240 380/400 400 45 0 500 660 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 (3) 3-pole contactors without auxiliary contact (standard EN 5002). (4) 95 A rated operational current in AC-3 up to 400 V. Other versions Contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. Please consult your Regional customer centre.

d 3-pole contactors for motor control, 9 to 80 A Utilisation category AC-3 Control circuit : d.c. a Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary Complete with code 50/60 Hz in category AC-3 current contacts indicating control (θ 55 C) in AC-3 circuit voltage (2) up to Fixing, 220V 380V 660V 0V cabling () 230V 400V 45V 0V 500V 690V kw kw kw kw kw kw A kg 2.2 4 4 4 5.5 5.5 9 LP-D090ii 0.580 LP-D090ii 0.580 3 5.5 5.5 5.5 7.5 7.5 2 LP-D20ii 0.580 LP-D20ii 0.580 LP-D090ii 4 7.5 9 9 0 0 8 LP-D80ii 0.600 LP-D80ii 0.600 5.5 5 5 25 LP-D250ii 0.850 LP-D250ii 0.850 7.5 5 5 5 8.5 8.5 32 LP-D320ii 0.880 LP-D320ii 0.880 8.5 22 22 22 30 40 LP-D40ii 2.00 LP-D320ii 5 22 25 30 30 33 50 LP-D50ii 2.20 8.5 30 37 37 37 37 65 LP-D65ii 2.60 22 37 45 45 55 45 80 LP-D80ii 2.220 Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LP-D09 to D25 : clip-on mounting on 35 mm " rail AM-DP. For LP-D40 to D80 : clip-on mounting on 75 mm " rail AM-DL. Power terminals : LP-D09 to D80 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 36 48 60 72 0 25 220 250 0 U 0.8. Uc (3) JD BD CD ED ND SD FD GD MD UD RD U 0.7.25 Uc (4) JW BW CW EW SW FW MW (3) LP-D40 to D80 : 0.85. Uc. (4) LP-D40 to D80 : 0.75.2 Uc. Other versions Contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. Please consult your Regional customer centre.

d 3 and 4-pole contactors for heating, lighting, etc., 25 to 25 A Utilisation category AC- Control circuit : a.c. Non inductive loads Number Instantaneous Basic reference. Weight Maximum operational of poles auxiliary Complete with code current contacts indicating control Utilisation category AC- circuit voltage (2) (θ 55 C) Fixing, cabling () A N/O N/C kg 25 3 LC-D0900ii 0.320 or LC-D200ii (3) 0.320 LC-D090ii 0.320 or LC-D20ii (3) 0.320 LC-D090ii 0.320 or LC-D20ii (3) 0.320 LC-D090ii 4 LC-D2004ii 0.320 2 2 LC-D2008ii 0.320 32 3 LC-D800ii 0.320 LC-D80ii 0.350 LC-D80ii 0.350 40 3 LC-D2500ii 0.320 LC-D250ii 0.505 LC-D250ii 0.505 LC-D2004ii 4 LC-D25004ii 0.505 2 2 LC-D25008ii 0.505 50 3 LC-D3200ii 0.320 LC-D320ii 0.525 LC-D320ii 0.525 60 3 LC-D40ii.50 4 LC-D40004ii.50 2 2 LC-D40008ii.50 80 3 LC-D50ii.50 or LC-D65ii (3).50 LC-D65004ii 4 LC-D65004ii.50 2 2 LC-D65008ii.50 25 3 LC-D80ii.500 or LC-D95ii (3).500 4 LC-D80004ii.530 2 2 LC-D80008ii.530 Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LC-D09 to D32 : clip-on mounting on 35 mm " rail AM-DP. For LC-D40 to D95 : clip-on mounting on 35 mm or 75 mm " rail AM-DL. Power terminals : LC-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c 24 42 48 0 220/230 230 240 380/400 400 45 0 500 660 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 (3) Selection according to number of operating cycles.

d 3 and 4-pole contactors for heating, lighting, etc., 25 to 25 A Utilisation category AC- Control circuit : d.c. Non inductive loads Number Instantaneous Basic reference. Weight Maximum operational of poles auxiliary Complete with code current contacts indicating control Utilisation category AC- circuit voltage (2) (θ 55 C) Fixing, cabling () A N/O N/C kg 25 3 LP-D090ii 0.580 or LP-D20ii (5) 0.580 LP-D090ii 0.580 or LP-D20ii (5) 0.580 4 LP-D2004ii 0.580 2 2 LP-D2008ii 0.580 LP-D090ii 32 3 LP-D80ii 0.600 LP-D80ii 0.600 40 3 LP-D250ii 0.850 LP-D250ii 0.850 4 LP-D25004ii 0.850 2 2 LP-D25008ii 0.850 50 3 LP-D320ii 0.880 LP-D320ii 0.880 LP-D320ii 60 3 LP-D40ii 2.00 4 LP-D40004ii 2.00 2 2 LP-D40008ii 2.00 80 3 LP-D50ii 2.20 or LP-D65ii (5) 2.60 4 LP-D65004ii 2.80 2 2 LP-D65008ii 2.80 25 3 LP-D80ii 2.220 4 LP-D80004ii 2.250 2 2 LP-D80008ii 2.250 Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LP-D2 to D32 : clip-on mounting on 35 mm " rail AM-DP. For LP-D40 to D80 : clip-on mounting on 75 mm " rail AM-DL. Power terminals : LP-D2 to D80 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 36 48 60 72 0 25 220 250 0 U 0.8. Uc (3) JD BD CD ED ND SD FD GD MD UD RD U 0.7.25 Uc (4) JW BW CW EW SW FW MW (3) For LP-D40 to D80 : 0.85. Uc. (4) For LP-D40 to D80 : 0.75.2 Uc. (5) Selection according to number of operating cycles.

d 3 and 4-pole contactors Components for assembling reversing contactors and changeover contactor pairs (horizontally mounted), for customer assembly Combinations Contactors Mechanical interlocks Set of power connections Assembled Without With integral 3-pole reversing contactors 4-pole changeover using 2 identical electrical interlocking electrical interlocking contactor pairs contactors (2 N/C contacts) horizontally mounted, type : A A2 L 2 L2 3 4 L3 5 6 2 3 4 5 6 A A2 A2 A /L U V W 2 /L2 3 4 /L3 5 6 8 7 N 3 4 6 5 2/L3 8 7 2N L A A2 L2 L3 N 2 2/L 2/L2 LC-D09 LA9-D09978 LA9-D0902 LA9-D269 LA9-D270 LC-D2 LA9-D869 LA9-D2570 LC-D8 LA9-D2569 LC-D25 LA9-D3269 LC-D32 LP-D09 LP-D2 LP-D8 LP-D25 LP-D32 LC-D40 LA9-D50978 LA9-D4002 LA9-D6569 LA9-D6570 LC-D50 LC-D65 LP-D40 LP-D50 LP-D65 LC-D80 LA9-D8069 LA9-D8070 LC-D95 LP-D80 LA9-D80978 LA9-D8002 LA9-D8069 LA9-D8070

d 3 and 4-pole contactors Components for assembling reversing contactors and changeover contactor pairs (horizontally mounted), for customer assembly c or a Component parts (including mechanical interlock with integral electrical interlocking) With Set of power connections Mechanical interlock 2 identical Reference Weight Kit reference Weight contactors () kg kg For assembly of 3-pole reversing contactors for motor control LC/LP-D09iiii LA9-D269 0.05 LA9-D0902 0.060 LC/LP-D2iiii LC/LP-D8iiii LA9-D869 0.030 LA9-D0902 0.060 LC/LP-D25iiii LA9-D2569 0.030 LA9-D0902 0.060 LC/LP-D32iiii LA9-D3269 0.040 LA9-D0902 0.060 LC/LP-D40ii LA9-D6569 0.290 LA9-D4002 0.70 LC/LP-D50ii LC/LP-D65ii LC-D80ii LA9-D8069 0.490 LA9-D4002 0.70 LP-D80ii LA9-D8069 0.490 LA9-D8002 0.70 LC-D95ii LA9-D8069 0.490 LA9-D4002 0.70 For assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) LC/LP-D2004ii LA9-D270 0.00 LA9-D0902 0.060 LC/LP-D25004ii LA9-D2570 0.020 LA9-D0902 0.060 LC/LP-D40004ii LA9-D6570 0.50 LA9-D4002 0.70 LC/LP-D65004ii LC-D80004ii LA9-D8070 0.280 LA9-D4002 0.70 LP-D80004ii LA9-D8070 0.280 LA9-D8002 0.70 Component parts (including mechanical interlock, without electrical interlocking) For assembly of 3-pole reversing contactors for motor control LC/LP-D090ii LA9-D269 0.05 LA9-D09978 0.030 LC/LP-D20ii LC/LP-D80ii LA9-D869 0.030 LA9-D09978 0.030 LC/LP-D250ii LA9-D2569 0.030 LA9-D09978 0.030 LC/LP-D320ii LA9-D3269 0.040 LA9-D09978 0.030 LC/LP-D40ii LA9-D6569 0.290 LA9-D50978 0.55 LC/LP-D50ii LC/LP-D65ii LC-D80ii LA9-D8069 0.490 LA9-D50978 0.55 LP-D80ii LA9-D8069 0.490 LA9-D80978 0.80 LC-D95ii LA9-D8069 0.490 LA9-D50978 0.55 For assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) (2) LC/LP-D2004ii LA9-D270 0.00 LA9-D09978 0.030 LC/LP-D25004ii LA9-D2570 0.020 LA9-D09978 0.030 LC/LP-D40004ii LA9-D6570 0.50 LA9-D50978 0.55 LC/LP-D65004ii LC-D80004ii LA9-D8070 0.280 LA9-D50978 0.55 LP-D80004ii LA9-D8070 0.280 LA9-D80978 0.80

Thermal overload relays d 3-pole thermal overload relays (class 0 A) adjustable from 0. to 93 A, for motor protection Thermal overload relays to be used with fuses Thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. Relay Fuses to be used For direct Reference Weight setting with selected relay mounting range Type beneath contactor am gg (BS88) LC, LP A A A kg Class 0 A () LR2-D3ii LR2-D23ii 0.0 0.6 0.25 2 D09 D32 LR2-D30 0.65 0.6 0.25 0.5 2 D09 D32 LR2-D302 0.65 0.25 0.40 2 D09 D32 LR2-D303 0.65 0.40 0.63 4 D09 D32 LR2-D304 0.65 0.63 2 4 D09 D32 LR2-D305 0.65.6 2 6 D09 D32 LR2-D306 0.65.6 2.5 4 0 D09 D32 LR2-D307 0.65 2.5 4 6 6 D09 D32 LR2-D308 0.65 4 6 8 6 D09 D32 LR2-D30 0.65 5.5 8 2 20 D09 D32 LR2-D32 0.65 7 0 2 20 D09 D32 LR2-D34 0.65 9 3 6 25 D2 D32 LR2-D36 0.65 2 8 20 32 D8 D32 LR2-D32 0.65 7 25 25 50 D25 and D32 LR2-D322 0.65 23 32 40 63 D25 and D32 LR2-D2353 0.320 30...40 40 80 D32 LR2-D2355 0.320 7 25 25 50 D40 D95 LR2-D3322 0.50 23 32 40 63 D40 D95 LR2-D3353 0.50 30 40 40 80 D40 D95 LR2-D3355 0.50 37 50 63 00 D50 D95 LR2-D3357 0.50 48 65 63 00 D50 D95 LR2-D3359 0.50 55 70 80 25 D65 D95 LR2-D336 0.50 63 80 80 25 D80 and D95 LR2-D3363 0.50 80 93 00 60 D95 LR2-D3365 0.50 3-pole thermal overload relays for use with unbalanced loads Class 0 A : Change the prefix in the references above from LR2 to LR3. Example : LR3-D30. () Standard IEC 947-4 specifies a tripping time for 7.2 times the setting current I R : class 0 A : between 2 and 0 seconds. LR2-D33ii Other versions Thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors (except LR2-D3365). Please consult your Regional customer centre. LR2, LR3-D Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset or on rail AM-DP200 or DE200 46 98 LA7-D064 43,5 d 79 AM-DP200 AM-DE200 d 2 9.5 () Can be mounted on RH or LH () + 5 mm for LR2-D5ii side of relays LR2, LR3-D 4 2xØ4,5 45 35 8 7 50/60() 08 LA7-D064 25 DX-AP25 2xØ6,5 0 LA7-D03 () 96 34

Thermal overload relays d 3-pole thermal overload relays (class 20) adjustable from 0. to 93 A, for motor protection LR2-D5ii Thermal overload relays to be used with fuses Thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. Relay Fuses to be used For direct Reference Weight setting with selected relay mounting range Type beneath contactor am gg (BS88) LC, LP A A A kg Class 20 () LR2-D25ii 2.5 4 6 6 D09 D32 LR2-D508 0.90 4 6 8 6 D09 D32 LR2-D50 0.90 5.5 8 2 20 D09 D32 LR2-D52 0.90 7 0 6 25 D09 D32 LR2-D54 0.90 9 3 6 25 D2 D32 LR2-D56 0.90 2 8 25 40 D8 D32 LR2-D52 0.90 7 25 32 50 D25 and D32 LR2-D522 0.90 23 32 40 63 D25 and D32 LR2-D2553 0.345 7 25 32 50 D40 D95 LR2-D3522 0.535 23 32 40 63 D40 D95 LR2-D3553 0.535 30 40 50 80 D40 D95 LR2-D3555 0.535 37 50 63 00 D50 D95 LR2-D3557 0.535 48 65 80 00 D50 D95 LR2-D3559 0.535 55 70 00 25 D65 D95 LR2-D356 0.535 63 80 00 25 D80 and D95 LR2-D3563 0.535 () Standard IEC 947-4 specifies a tripping time for 7.2 times the setting current I R : class 20 : between 6 and 20 seconds. LR2-D35ii Other versions Thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors. Please consult your Regional customer centre. LR2, LR3-D2 Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset device or on rail AM-DP200 or DE200 57 LA7-D2064 98 43,5 d 90 3 55 2xØ4,5 40 3 22 50/60 08 LA7-D2064 DX-AP26 AM-DP200 AM-DE200 () Can be mounted on RH or LH d 2 9.5 side of relays LR2, LR3-D2 LR2, LR3-D3 Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset device or on rail AM-DP200 or DE200 LA7-D902 75 75 LA7-D3064 50 LA7-D3064 25 2xØ6,5 0 96 LA7-D03 () 29 LA7-D03 () 2 5,5 d 00 2 2xØ4,5 32 75/87 23,5 3 AM-DP200 AM-DE200 () Can be mounted on RH or LH side d 2 9.5 of relays LR2-D, LR3-D3 26 3xØ6,5 40 0 9 2

Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Accessories (to be ordered separately) Description For use on Sold in Unit Weight overload relays lots of reference kg rminal blocks () LR2-D LA7-D064 0.00 for clip-on mounting on LR3-D 35 mm rail (AM-DP200) LR2-D2 LA7-D2064 0.20 or screw fixing. LR3-D2 See pages /26 and /27 LR2-D3 LA7-D3064 (2) 0.205 for fixing centres LR3-D3 Power terminals adaptor LR2-D LA7-D058 0.080 for mounting an LRi-D3 LR3-D overload relay beneath an LC-D40, D50 or D65 contactor Mounting plates (3) LR2-D 0 DX-AP25 0.065 for screw fixing LR3-D on 0 mm centres LR2-D2 0 DX-AP26 0.082 LR3-D2 LR2-D3 LA7-D902 0.30 LR3-D3 Marker holder LR2-D 00 LA7-D903 0.00 snap-in LR3-D Bag of 400 labels LA9-D9 0.00 (blank, self-adhesive) 7 x 6 mm Locking device LR2-D 0 LA7-D90 0.005 for Stop button LR3-D Remote tripping and LR2-D LA7-D03i (5) 0.090 electrical reset device (4) LR3-D Remote control Reset function By flexible cable LR2-D LA7-D305 0.075 (length 0.5 m) LR3-D Stop and/or Reset function For fitting, remove the terminal protection shrouds and order the following 3 products : Adaptor LR2-D LA7-D020 0.005 for door mounted operator LR3-D Rod (snap-off end to obtain required LR2-D 0 ZA2-BZ3 0.00 length between 7 and 20 mm) LR3-D Operating head LR2-D ZA2-Biiii (6) 0.02 for spring return pushbutton LR3-D () rminal blocks are supplied with terminals protected against direct finger contact. Ready-to-tighten screws. (2) With terminals for ring type connectors, the reference becomes LA7-D30646. (3) Remember to order the terminal block corresponding to the overload relay size. (4) The time for which the coil of remote tripping and electrical resetting device LA7-D03 can remain energised depends on its rest time : s pulse duration with 9 s rest time ; 5 s pulse duration with 30 s rest time ; 0 s pulse duration with 90 s rest time ; maximum pulse duration of 20 s with a rest time of 300 s. Minimum impulse time : 200 ms. (5) Reference to be completed by adding the coil voltage code. Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c 2 24 48 96 0 220/230 380/400 45/0 50/60 Hz B E F M Q N Consumption, inrush and sealed : < 00 VA Volts a J B E DD F M Consumption, inrush and sealed : < 00 W. (6) Reference to be completed, please refer to chapter 5. LA7-D020 Adaptor for door mounted operator c 0 Stop Reset LA7-D305 Reset by flexible cable Mounting with cable straight LA7-D305 Mounting with cable bent LA7-D020 e c c : adjustable from 7 to 20 mm c : up to 550 mm e : up to 20 mm e : up to 20 mm e M0x

Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Scheme, setting-up Scheme LR2-D LR3-D 3 5 RESET{ Auto. Man. 2 4 6 TEST 96 95 97 98 STOP Setting-up the special functions of LR2-D and LR3-D thermal overload relays Setting the relay Manual-Automatic selection 4 7 2 6 3 6 7 5,5 TEST 8 A LR2 D 3 M STOP RESET A U T O 5 4 RESET A U T O RESET A U T O NO NC 98 97 95 96 Manual reset Automatic reset i Lift the transparent cover to gain access to the settings and controls. i Adjustment is achieved by turning dial 2 which is graduated directly in Amperes. i The setting can be locked by sealing 3 of the cover. i After having lifted the transparent cover, the type of reset operation can be selected by turning the blue RESET selector 4 : - turn to the left for manual reset, - push and turn to the right for automatic reset. The selector is then held in the automatic position and is released by turning the selector to the left (return to manual operation). i With the cover folded down, the selector is locked. i Manual resetting of the relay is achieved by pressing the blue RESET button. Stop function 5 st function 6 STOP ET A U T O RESET A U T O TEST Stop Locking st Trip indicator i The Stop function is obtained by pressing the red STOP button 5. i Pressing the STOP button : - actuates the N/C contact, - does not affect the N/O contact. i The STOP button can be locked by fitting a U clip (ref. LA7-D90). With the cover folded down, the device is locked. i The st function is obtained by pressing the red TEST button 6 with a screwdriver. i Operation of the TEST button simulates tripping of the relay and : - actuates both N/O and N/C contacts, - actuates the trip indicator 7.

Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Dimensions LR2, LR3-D Direct mounting beneath contactors LC-D09 to D32, LP-D09 to D32 and LP4-D2 e AM-DP200 AM-DE200 d 2 9.5 b 47() 92 c d 8 7 g b () c e g LC-D09, D2, D8 8 98 50 0 LC-D25 86 08 55 0.7 LC-D32 86 09 55 8. LP-D09, D2, D8 8 33 50 0 LP-D25 86 52 55 0.7 LP-D32 86 53 55 8. LP4-D2 8 98 50 0 () + 5 mm for LR2-D5ii LR2, LR3-D2 Direct mounting beneath contactors LC-D25 and D32, LP-D25 and D32 59 b e AM-DP200 AM-DE200 d 2 9.5 92 c d 3 22 54 g b c e g LC-D25 97.5 98 60.5 LC-D32 97.5 98 60 0.5 LP-D25 97.5 55 60.5 LP-D32 97.5 55 60 0.5 LR2, LR3-D3 Direct mounting beneath contactors LC-D40 to D95 and LP-D40 to D80 AM-DL20 AM-DL200 d 7 7 54 e 4 09 c b d 2 30 70 g b c e g (3P) g (4P) LC-D40 9 72.4 4.5 3 LC-D50 9 72.4 4.5 LC-D65 9 72.4 4.5 3 LC-D80 5.5 24 76.9 9.5 22 LC-D95 5.5 24 76.9 9.5 LP-D40 76 72.4 4.5 3 LP-D50 76 72.4 4.5 LP-D65 76 72.4 4.5 3 LP-D80 5.5 79.4 76.9 9.5 22

d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : a.c. Instantaneous auxiliary contact blocks () For use in normal operating environments Number Max. number of blocks per contactor Composition Reference Weight of Clip-on mounting contacts Front Side (D25 and D32) LA-DN0 0.020 or 2 (D40 D95) LA-DN0 0.020 2 (D09 D95) LA-DN 0.030 kg 2 LA-DN20 0.030 2 LA-DN02 0.030 2 (D09 D95) LA8-DN 0.030 2 LA8-DN20 0.030 4 (D09 D95) 2 2 LA-DN22 0.050 With terminal referencing conforming to standard EN 5002 3 LA-DN3 0.050 4 LA-DN40 0.050 4 LA-DN04 0.050 3 LA-DN3 0.050 2 2 (2) LA-DC22 0.050 2 (D090 D320) LA-DNM 0.030 (D0900 D3200) LA-DNP 0.030 (D40 D95) LA-DNG 0.030 4 (D090 D320) 2 2 LA-DN22M 0.050 (D0900 D3200) 2 2 LA-DN22P 0.050 (D40 D95) 2 2 LA-DN22G 0.050 Instantaneous auxiliary contact blocks with dust and damp protected contacts () For use in harsh industrial environments 2 (D09 D95) 2 LA-DX20 0.040 2 (3) LA-DY20 0.040 4 (D09 D95) 2 2 LA-DZ40 0.050 2 LA-DZ3 0.060 () Maximum mounting capacity, depending on type of coil. Device Coil Operation Maximum number of add-on blocks type type guaranteed Clip-on mounting from front side LC-D 50 or 60 Hz 0.8. Uc + 2 50/60 Hz 0.8. Uc or 2 0.85. Uc + 2 (2) Including N/O and N/C make before break. (3) Device fitted with 4 terminals for earth screen continuity.

d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : a.c. Time delay auxiliary contact blocks () Number Maximum number of Time delay Reference Weight of blocks per contactor Type Setting contacts Front clip-on mounting range kg N/O (D09 D95) On-delay 0. 3 s (2) LA2-DT0 0.060 + N/C 0. 30 s LA2-DT2 0.060 0 80 s LA2-DT4 0.060 30 s (3) LA2-DS2 0.060 Off-delay 0. 3 s (2) LA3-DR0 0.060 0. 30 s LA3-DR2 0.060 0 80 s LA3-DR4 0.060 Mechanical latch blocks () Unlatching Clip-on Basic reference. Weight control front mounting To be completed (4) kg Manual LC-D09 D65 LA6-DK0i 0.070 or electric LC-D80 D95 LA6-DK20i 0.090 () Maximum mounting capacity, depending on type of coil. Device Coil Operation Maximum number of add-on blocks type type guaranteed Clip-on mounting from front side LC-D 50 or 60 Hz 0.8. Uc + 2 50/60 Hz 0.8. Uc or 2 0.85. Uc + 2 (2) With extended scale from 0. to 0.6 s. (3) With switching time of 40 ms ± 5 ms between opening of the N/C contact and closing of the N/O contact. (4) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c or a 2 24 32/36 42/48 60/72 00 0/27 220/240 255/277 380/45 Code J B C E EN K F M U Q

d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : d.c. Instantaneous auxiliary contact blocks () For use in normal operating environments Number Max. number of blocks per contactor Composition Reference Weight of Clip-on mounting contacts Front Side (D25 and D32) LA-DN0 0.020 2 (D40 D80) LA-DN0 0.020 2 (D09 D80) LA-DN 0.030 2 LA-DN20 0.030 2 LA-DN02 0.030 2 (D09 D32) LA8-DN 0.030 2 LA8-DN20 0.030 4 (D09 D80) 2 2 LA-DN22 0.050 3 LA-DN3 0.050 4 LA-DN40 0.050 4 LA-DN04 0.050 3 LA-DN3 0.050 2 2 (2) LA-DC22 0.050 Instantaneous auxiliary contact blocks with dust and damp protected contacts () kg For use in harsh industrial environments 2 (D09 D80) 2 LA-DX20 0.040 2 2 (3) LA-DY20 0.040 4 (D09 D80) 2 2 LA-DZ40 0.050 2 LA-DZ3 0.060 Time delay auxiliary contact blocks () Number Max. number of blocks per contactor Time delay Reference Weight of Clip-on mounting Type Setting contacts Front Side range(s) kg N/O (D09 D80) On 0. 3 (4) LA2-DT0 0.060 + delay N/C 0. 30 LA2-DT2 0.060 Mechanical latch blocks (Manual or electric unlatching control) 0 80 LA2-DT4 0.060 30 (5) LA2-DS2 0.060 Off 0. 3 (4) LA3-DR0 0.060 delay 0. 30 LA3-DR2 0.060 0 80 LA3-DR4 0.060 Front clip-on Basic reference. Weight mounting To be completed (6) kg LP-D09 D65 LA6-DK0i 0.070 LP-D80 LA6-DK20i 0.090 () Either of the following may be fitted, as required: 2 side-mounting contact blocks or front mounting contact block. (2) Including N/O + N/C make before break. (3) Device fitted with 4 terminals for earth screen continuity. (4) With extended scale from 0. to 0.6 s. (5) With switching time of 40 ms ± 5 ms between opening of the N/C contact and closing of the N/O contact. (6) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c or a 2 24 32/36 42/48 60/72 00 0/27 220/240 255/277 380/45 Code J B C E EN K F M U Q

d 3 and 4-pole contactors, reversing and changeover contactors Accessories Electronic serial timer modules () Operational voltage (2) Time delay Reference Weight c LC- a LP- 24 250 V 00 250 V 24 250 V kg On-delay type D09 D32 D40 D95 D09 D32 0. 2 s -DT0U 0.040 Off-delay type.5 30 s -DT2U 0.040 25 500 s -DT4U 0.040 D09 D8 D25 D95 0. 2 s -DR0U 0.050 Interface modules ().5 30 s -DR2U 0.050 25 500 s -DR4U 0.050 Operational voltage Supply Reference Weight c LC- a LP- voltage 24 250 V 00 250 V 380 45 V 24 250 V E-E2 (a) kg Relay interface D09 D95 24 V -DFBQ 0.055 D09 D95 D09 D32 24 V -DFB 0.050 Relay interface with manual override switch (output forced ON ) 48 V -DFE 0.050 D09 D95 D09 D32 24 V -DLB 0.045 Solid state interface 48 V -DLE 0.045 D09 D32 D40 D95 24 V -DWB 0.045 Auto-Man-Stop control modules () For local override operation tests with 2-position Auto-Man switch and O-I switch Operational voltage Reference Weight c LC- a LP- 24 00 V 00 250 V 24 00 V 00 250 V kg D09 D95 D09 D32 -DMK 0.040 D09 D95 D09 D32 -DMU 0.040 Indicators (contactor state) Red LED For mounting on contactors Supply Sold in Unit Weight LC and LP voltage (c and a) lots of reference kg Clips into 2 72 V 5 -DVE 0.00 legend plate location on all contactor sizes 72 250 V 5 -DVM 0.00 250 0 V 5 -DVR 0.00 () Mounted at top on terminals A and A2 (screw fixing). (2) For 24 V operation, the contactor must be fitted with a 2 V coil (code Z). See pages /49 to /52.

d 3 and 4-pole contactors, type LC-D Dimensions LC-D09, D2 0 93 3(2)(LA) 36(LA6-DK) 45() (LA2,LA3,LA6-DK2) 74 2,5 77(Di) 90(Di2) 45 2,5 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) LC-D8 LC-D2500 0 85 8(2)(LA) 28(LA6-DK) 37() (LA2,LA3,LA6-DK2) 74 2,5 77(Di) 90(Di2) 45 2,5 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts (2) With 2 or 4 contacts (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DA, DE -DA, DE LC-D250, D250, D25004 LC-D32 84 87(Di) 00(Di2) 07(3)(DF,DT) (DM,DR,DW,DL) 84 87(Di) 00(Di2) 07(3)(DF,DT) (DM,DR,DW,DL) 0 93 26(2)(LA) 36(LA6-DK) 45() (LA2,LA3,LA6-DK2) 2,5 56 2,5 5(3) 0 98 3(2)(LA) 4(LA6-DK) 50() (LA2,LA3,LA6-DK2) 2,5 56 2,5 5(3) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact 20 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact 25 (LA-DN0 or DN0) (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DA, DE -DA, DE LC-D40, D50, D65 28 LC-D80, D95 32 27 35(Di2) 42(DF,DT) 50(DM,DR,DW,DL) 27 35(Di2) 42(DF,DT) 50(DM,DR,DW,DL) 2 4(4) 45(2)(LA) 64()(LA2,LA3,LA6-DK2) 2,5 (3) 2,5 2 25(4) 53(2)(LA) 72()(LA2,LA3,LA6-DK2) 2,5 (3) 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact 39 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact 47 (LA-DN0 or DN0) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 25 : LC-Dii008 (4) 40 : LC-Dii008

d 3 and 4-pole contactors, type LP-D Dimensions LP-D09, D2 LP-D8 74 77(Di) 90(Di2) 97(3)(DF,DT) 05(3)(DM,DL) 74 77(Di) 90(Di2) 97(3)(DF,DT) 05(3)(DM,DL) 0 5 48(2)(LA) 58(LA6-DK) 67()(LA2,LA3,LA6-DK2) 2,5 45 2,5 0 20 53(2)(LA) 63(LA6-DK) 72()(LA2,LA3,LA6-DK2) 2,5 45 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts (2) With 2 or 4 contacts (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DC, DE. -DC, DE. LP-D25 LP-D32 84 87(Di) 00(Di2) 07(3)(DF,DT) 5(3)(DM,DL) 84 87(Di) 00(Di2) 07(3)(DF,DT) 5(3)(DM,DL) 0 30 63(2)(LA) 73(LA6-DK) 82()(LA2,LA3,LA6-DK2) 2,5 56 2,5 0 35 68(2)(LA) 78(LA6-DK) 87()(LA2,LA3,LA6-DK2) 2,5 56 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact : 57 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact : 62 (LA-DN0 or DN0) (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DC, DE. -DC, DE. LP-D40, D50, D65 LP-D80 -Di3 -Di3 27 27 2 7(4) 202(2)(LA) 22()(LA2,LA3,LA6-DK2) (3) 2 8(4) 20(2)(LA) 229()(LA2,LA3,LA6-DK2) (3) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact : 96 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact : 204 (LA-DN0 or DN0) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 82 : LP-Dii008 (4) 96 : LP-Dii008