Micro Diaphragm Pumps (air/gas)

Similar documents
Micro Diaphragm Pumps (air/gas)

BTC-IIS Series Miniature Diaphragm Pumps (air/gas)

Miniature Pumps Precision Fluidics. PNEUMATIK. HYDRAULIK. E-ACHSEN. BILDVERARBEITUNG Komponenten & Systemintegration

Product Specifications *

Product Specifications *

Miniature Pumps Precision Fluidics

Miniature Pneumatic Solenoid Valve

Miniature Pneumatic Solenoid Valve. Power: 0.5 Watt & 1.0 Watt. Not all power options are available in all models, see ordering info.

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve

Miniature Proportional Valves Precision Fluidics

Miniature Pneumatic Solenoid Valve

VSO Thermally Compensated Proportional Valve

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

Miniature Solenoid Valves

(Accessory, see ordering info) Wetted Materials

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve

Miniature Solenoid Valves Precision Fluidics. PNEUMATIK. HYDRAULIK. E-ACHSEN. BILDVERARBEITUNG Komponenten & Systemintegration

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

Miniature Solenoid Valves

Thermal Mass Flow Meter (Analog)

Miniature Multimedia Valves

VSO - MI thermally compensated proportional valve

SP 700 EC-TH / 730 EC-TH / 730 EC-EV

SP 700 EC-TH / 730 EC-TH / 730 EC-EV

Advancements in Noise Reduction Techniques for Medical Equipment Manufacturers

Miniature Solenoid Valves. Precision Fluidics

FEATURES AND BENEFITS

Max Series Venturi Vacuum Pump with Pneumatic Blow-off and Silencer

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

MINIATURE SOLENOID GENERAL SERVICE VALVES

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Series 2 Product Family Diaphragm Compressors & Vacuum Pumps Piston Compressors Revised September 2015

Proportional Control Valves

Digital and Proportional Miniature Solenoid Valves

Mechanical Specifications:

Design Considerations for Pressure Sensing Integration

Products. Engineering Design Services. Contract Manufacturing

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

Portable TOC Analyser for Stack Emissions

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003

MPD Series. Medium Pressure Duplex

Proportional Control Valves

Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Sporlan Gas Cooler/ Flash Gas Bypass Valves

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

MAX FLUID TEMPERATURE

PRESSURE BENCH OPERATING INSTRUCTIONS

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

ELECTRONIC MOUSE SERIES

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

EZ-View. Flow Meters ISO CERTIFIED 9001

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

M-100 Series. Adjustable flow switch with right-angle flow

Dimensions: 48 Wide x 96 Long x 88 Tall (with exhaust stack), 1,445 pounds

SSI Technologies Application Note PS-AN3 MediaGauge Digital Pressure Gauges Product Overview

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

MPD Series Medium Pressure Filters

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

AAA Series Micro Air Pump: Part No. 3A030CNSN (Pressure) Specifications

Haze Battery Company Ltd

Mini Pressure Transmitter HA7

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Models 415 & 425. Electronic Pressure Regulators. Customer Value Proposition: Contact Information:

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

PF Series Thermoplastic Non-Spill Couplings and Industrial Hose Products

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Pressure Transmitter

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

Industrial Pressure Transmitters

2100 Turbine Flow Sensor

Valve technology for the gas industry Date: 04/2013

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Packless Valves. Instrument / Analyzer Products. Catalog 4515/USA April 2006

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Vortex Eggs Delta Flowmeter

PS11 Ultra-Long Life OEM Pressure Switches

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

Transcription:

10 Up to 800 mlpm Free Flow Typical Markets Safety Patient Therapy Patient Monitoring Typical Applications Portable Gas Detection Gas Sampling Medical Instruments Trace Detection Sidestream CO 2 Negative Pressure Wound Therapy Product Specifications * Physical Properties Operating Environment 1 : -4 to 122 F (-20 to 50 C) Storage Environment: -4 to 122 F (-20 to 50 C) Media: Air, Argon, Helium, Nitrogen, Oxygen, and other non-reacting gases Humidity: Most non-condensing gases 5-95% Relative Humidity Noise Level 2 : As low as 45dB Pump Assembly Rated Life 3 : Coreless Motor-Pump (HE): Up to 10,000 hours Coreless Motor-Pump (LI): Up to 6,000 hours PMDC Iron Core-Pump (IC): Up to 1,500 hours Weight: 0.5 oz (14 g) HE and LI 0.4 oz (11 g) IC Parker s 13.5 mm wide micro diaphragm pump is designed to fit where other pumps cannot due to its small, compact package size. The flow path is optimized to deliver high flow with high efficiency resulting in extended battery life. The pump s low power, small size, and light weight play a critical role in portable gas detection and medical applications. The pump HE and LI pump models enable intrinsic safety capabilities for sampling of hazardous gases, typical of industrial and mining operations. The IC pump is designed for compact and wearable medical devices that require less than 1500 hours of pump life. The VBIC model is ideal for vacuum only medical applications that benefit from improved sound quality, such as wound therapy. Features The valve design has been optimized to provide the highest flow rates available with the lowest current draw, allowing for longer battery life and smaller instrument size. The model pump life ranges up to 10,000 rated hours depending on motor (HE, LI and IC) options The pump fits into the extremely tight spaces demanded of today s handheld instruments, such as portable gas detectors and portable negative pressure wound therapy devices for patient mobility. The lightweight design minimizes instrument weight. RoHS compliant. Electrical Motor Type (DC): High Efficiency Coreless Brush (HE) Low Inductance Coreless Brush (LI) PMDC Iron Core Brush (IC) Nominal Motor Voltages (DC) 4 : 3.3 VDC Max Power at Nominal Voltage: 0.36 Watts Electrical Termination: HE: Wire Leads LI: Wire Leads IC: Solder Tabs Current Range 5 : 34-105 ma Inductance 6 : HE: 0.28 mh maximum @ 1kHz/50mV LI: 0.05 mh maximum @ 1kHz/50mV IC: 4.07 mh maximum @ 1kHz/50 mv Pneumatic Head Configuration: Single Maximum Flow: HE, LI: 800 smlpm, IC: 700 smlpm Maximum Intermittent Pressure 7 : 6.2 psi (430 mbar) Maximum Continuous Pressure: 2.0 psi (138 mbar) Maximum Intermittent Vacuum 7 : 10.8 in Hg (274 mm Hg) Maximum Continuous Vacuum: 4.1 in Hg (104 mm Hg) Filtration: 40 micron recommended Efficiency at Free Flow 8 : LPM/Watt: 4.66 @ 1.9 VDC (P/N T5-1HE-03-1EEB) LPM/Watt: 4.08 @ 1.9 VDC (P/N T5-1LI-03-1EEB) LPM/Watt: 3.12 @1.9 VDC (P/N T5-1IC-03-1EEP) Wetted Materials Diaphragm: EPDM Valves: EPDM Pump Head: ABS (HE, LI), PBT (IC) * See Appendix A for details.

11 Performance Specifications Flow (ml/m) 900 800 700 600 500 400 300 200 100 0 Pump Coreless Brush Motor Vacuum (mm Hg) Pressure (bar) 254 203 152 102 51 0 0.07 0.14 0.21 0.28 0.35 intermittent duty intermittent duty continuous duty 10 8 6 4 2 0 1 2 3 4 5 Vacuum (in Hg) Pressure (psig) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 Power Usage (W) Max Flow 4.5V Min Flow 1.9V Max Power 4.5V Min Power 1.9V 800 T2 05 Pump PMDC PMDC Iron Iron Core Core Brush Motor Motor Vacuum (mm Hg) Pressure (bar) 400 300 200 100 0 0.13 0.27 0.40 0.35 0.60 FLOW (ml/m) 700 600 500 400 300 200 intermittent duty intermittent duty 0.10 100 continuous duty 0 0.00 500 400 16 300 12 200 8 100 4 0 100 2 200 4 300 6 400 8 500 Vacuum (In Hg) Prssure (psig) 0.50 0.40 0.30 0.20 POWER (W) Max Flow 4.5V Max Power 4.5V Min Flow 2.5V Min Power 2.5V The above graphs represent examples of performance for the pumps series handling air at 800 feet (244M) above sea level at 75 F (24 C). Performance will vary depending on barometric pressure and media temperature. Curves are representative of standard pump configurations. Pump configurations could be customized for higher or lower flows, depending on specific customer requirements. Please contact Parker Precision Fluidics Applications Engineering for other considerations

12 Sizing and Selection Series Inductance 6 Coreless Brush Motor (High Efficiency) HE Better Coreless Brush Motor (Low Inductance) LI PMDC Iron Core Motor (Iron Core) IC N/A Efficiency at Free Flow 8 Better Life 3 Better Good Cost Good Better Mounting Guidelines: Parker recommends using a nylon cable tie with a length of at least 4 (100 mm). Mechanical Integration Dimensions Port Connections: HE & LI: 3/32" ID tubing IC: 1/8" ID tubing 3/32" [2.4] HOSE BARB (DISCHARGE).53 [13.5] Coreless Brush/HE Version 3/32" [2.4] HOSE BARB (SUCTION) 1.26 [32.0].12 [3.0].53 [13.5].24 [6.1].62 [15.7].08 [2.0] Ø.47 [Ø12.0]

13 Mechanical Integration Dimensions 3/32" [2.4] HOSE BARB (DISCHARGE) Coreless Brush/LI Version.53 [13.5] 1.16 [29.5].53 [13.5] 3/32" [2.4] HOSE BARB (SUCTION).12 [3.0].24 [6.1].62 [15.7].08 [2.0] Ø.47 [Ø12.0] Pump/Iron Core Pump/Iron Core Units IN. (mm.) 1/8" HOSE BARB SUCTION 1/8" HOSE BARB SUCTION.53 [13.51 mm].53 [13.51 mm] 1/8" HOSE BARB DISCHARGE 1/8" HOSE BARB DISCHARGE 1.30 [33.11] 1.30 [33.11] PMDC Iron Core/IC Version.55 [13.89] 1.25 [31.76].55 [13.89] 1.25 [31.76].05 [1.35] MAX.05 [1.35] MAX.12 [3.05].12 [3.05].24 [6.10].24 [6.10] WHITE MARK ON MOTOR: INDICATES POSITIVE TERMINAL (+) WHITE MARK ON MOTOR: INDICATES POSITIVE TERMINAL (+).08 [1.91].62 [15.72].08 [1.91] Ø.16 [4.0].62 [15.72] Ø.47 [12.0] Ø.47 Ø.16 [12.0] [4.0] NEGATIVE TERMINAL (-) NEGATIVE TERMINAL (-).39 [10.0] ACROSS FLATS.39 [10.0] ACROSS FLATS Units IN. (mm.) INITS IN. [mm] INITS IN. [mm] PMDC Iron Core/IC Version Improved Sound Configuration*.25 [6.3].71 [18.1].65 [16.5].12 [3.1].11 [2.7].73 [18.5] 1.52 [38.7] WHITE MARK ON MOTOR INDICATES POSITIVE TERMINAL (+).05 [1.35] MAX Ø.47 [Ø12.0].37 [9.4] Ø.16 [Ø4.0] * Improved sound configuration released with IC configuration for vacuum applications. Contact factory for use with HE or LI configurations for either vacuum or pressure applications.69 [15.0].95 [24.1].14 [3.6] 1.42 [36.0] NEGATIVE TERMINAL (-).39 [10.0] ACROSS FLATS Units IN. (mm.)

14 Electrical Integration and Motor Control Coreless Brush Motor (HE, LI) 2 Wire Red (+), Black (-) Wire specification PMDC Iron Core Brush Motor (IC) Tabs Key Things to Remember 28 AWG 5.7 (145 mm) Wire Leads Standard solder tabs for electrical connection 5.7 (145 mm) flying Leads are the standard electrical connection method to the pump. Contact Parker Engineering for other connection requirements. Pump life is highly dependent on operating conditions. It is not recommended to run the pump continuously, 100% duty cycle, at higher than 2 psig. The pump flow and pressure can be controlled by adjusting the input voltage from zero to maximum rated voltage. The pump is not a pressure holding device. An external check valve is recommended, if there is a pressure holding requirement. Pump orientation does not affect performance or life. Typical Flow Diagram Negative Pressure Wound Therapy Diagram FILTER OUT TO ATMOSPHERE X-VALVE CHECK VALVE PUMP VENT TO ATMOSPHERE PNEUMATIC PUMP LOW LEAK CAPABILITY MAY ELIMINATE THE NEED FOR A CHECK VALVE LIQUID ISOLATION FILTER WOUND DRESSING WASTE CANISTER

15 Typical Flow Diagram Gas Detection Diagram T2-03 PUMP DIAGRAM DISPLAY / ALARM IN FROM ATMOSPHERE FILTER PUMP Side Stream Capnography Diagram SENSOR BOARD SIDE STREAM CAPNOGRAPHY DIAGRAM OUT TO ATMOSPHERE CO2 SENSOR X-VALVE IN FROM PATIENT FILTER APPLICATION SPECIFIC RESTRICTOR PUMP Chemical Compatibility Chart * Chemical Compatibility of Wetted Path Materials Chemical EPDM ABS PBT Air 1 1 1 Ozone (1000 ppm) 4 2 1 Oxygen 1 1 1 Ethylene (Ethene) 4 1 1 Acetylene 1 2 2 Propane 4 2 2 Methane 4 4 2 Nitrogen 1 1 1 Carbon Dioxide 2 2 1 Halothane (Up to 5%) 4 1 1 *The above is an Abbreviated Chemical Compatibility Chart. Please consult factory for details. Compatibility Legend 1. EXCELLENT Minimal or no effect 2. GOOD Possible swelling and/or loss of physical properties 3. DOUBTFUL Moderate or severe swelling and loss of physical properties 4. NOT RECOMMENDED Severe effect and should not be considered Note: Consult factory for other gases.

16 Ordering Information Configuration 12 in Hg 305 mm Hg Vacuum: LPM @ Load 8 in Hg 203 mm Hg 4 in Hg 102 mm Hg Free Flow 2 psig 134 mbar 4 psig 276 mbar 6 psig 414 mbar T5-1HE-03-1EEB 0.2 0.5 0.8 0.6 0.3 10.8 6.2 T5-1LI-03-1EEB-1 0.2 0.5 0.8 0.6 0.3 10.8 6.2 0 Pressure: LPM @ Load Coreless Brush Coreless Brush PCD* Wetted Materials 4.5 438 EPDM 4.5 438 EPDM T5-1IC-03-1EEP 0.2 0.5 0.7 0.5 0.3 10.0 6.2 PMDC 4.5 240 EPDM Vac in Hg Max Press psig Motor Type VDC ma Diaphragm, Valves, Gasket T5-VBIC-03-1EEP 0.2 0.5 0.7 10.0 PMDC 4.5 240 EPDM *PCD: Peak Current Draw The T5-VBIC-03-1EEP is a -IC Reduced Sound pump that uses a proprietary design to reduce noise and it is a recommended option in applications where sound quality is also a critical customer need. -LI and HE model Sound Improvement options are also available, contact applications for more details. Applications Engineering can assist with sound quality evaluations given the complex relationship between system components and operational requirements of the customer s specific application. Please refer to sizing and selection chart for identifying which one will fit your application Please click on the Order On-line button below (or go to www.parker.com/precisionfluidics/t5) to configure your Micro Diaphragm Pump. Serviceable PPF products are designed for use through the rated life and Parker does not sell replacement parts, nor is it recommended to service these in the field Note: In addition to Parker s innovative and flexible pump designs, we offer applications engineering expertise to our customers in order to configure and recommend the optimal pump for the application. Contact Parker Applications Engineering to discuss and configure alternate pump configurations to meet your specific application requirements. Providing information on the following requirements will assist us in developing an optimal solution for your application: Noise Operating Pressure / Vacuum Power Consumption Life Requirement Size Motor Control Media Voltage ORDER ON-LINE

17 Appendix A All performance data is typical based on standard conditions: 70 F and 14.7 psia (21 C and 1 bar). 1. Duty Dependent. For operation above 122 F (50 C) consult factory 2. Noise is dependent on the configuration and operation of the pump in the application. Parker has the ability to tailor the pump configuration when noise is a critical criterion in the effort to meet the performance requirements of the application. Noise level is tested to Parker protocol P-105. 3. Life rating can vary depending on application and operating conditions. 4. Custom motor options available. Custom motors may require a significant application potential. The standard motors can be configured with a special winding to meet a particular operation point at a specified voltage 5. Current range is dependent on motor type, voltage, pressure/vacuum and flow requirement. Lower levels possible depending on application. 6. Inductance is an indicator of induced voltage with change in current and it is a key parameter to enable customers low energy intrinsic safety systems 7. Maximum intermittent pressure/vacuum data is a pump capability guideline for applications that go beyond the maximum continuous levels for short periods of time. Please consult customer specific requirements with the factory or Applications Engineering. 8. Pump efficiency is a measure of the flow rate generated per unit of power consumed. Efficiency may change dependent on application and operating condition at free flow. 2015 Parker Hannifin Corporation PPF MDP - 002/US May 2015 Parker Hannifin Corporation Precision Fluidics Division 26 Clinton Dr., Unit 103 Hollis, NH 03049 phone: +1 603 595 1500 email: ppfinfo@parker.com www.parker.com/precisionfluidics