Primary, Secondary, Post-Secondary Education Facilities

Similar documents
STABILOY BRAND FeeDeR SOLuTIONS

ATHLETIC STADIUMS AND SPORTS ARENAS

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

HOSPITAL AND HEALTHCARE

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

RENEWABLE ENERGY. Alcan cable solutions


Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

NEC 2014 Code Changes

The Reliable Choice. Field Pocket Guide

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

SECONDARY 600 VOLT CABLES

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-RHH/RHW-2 USE-2 Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

Variable Frequency Drive (VFD) Cable Solutions

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

MC, THHN/THWN-2 Copper

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MC or MV-105 Copper, TR-XLPE Insulated

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

Mecklenburg County Common Code Defects

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Variable Frequency Drive (VFD) Cable Solutions

CHAPTER V RESIDENTIAL WIRING

Easier! Faster! Safer!

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

PART A General Conductor Requirements

AMENDMENT ELECTRIC SERVICE MANUAL 2014

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Code Calculations. for an Off-Grid PV System

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Section 02: Pre-Installation Procedures

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

TUNNELING POWER CABLES

KALAS ENTERTAINMENT CABLE

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

PHOTOVOLTAIC SYSTEMS

C-L-X Aluminum Sheath Type IEC

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Introducing. Paralleled

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

2016 Photovoltaic Solar System Plan Review List

Wired for Power Generation

E R C. R E R C ; ; W T E C

320A Single Phase URD Meter Loop Installations

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

High Voltage Copper, Smooth Aluminum Shield/Sheath

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Category # 1 - Overhead, Primary, & Secondary Conductors

Spring Test 10 due 05/11/2013

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

MEDIUM VOLTAGE

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Electrical Design/Build Guide

IEEE 1580 TYPE T/N CABLE

Section 8. Portable Cordage & Power Cable

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Have You Been Grounded Lately

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

Medium Voltage Power Cables

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

EV Charging Station Submittal Requirements

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

SINGLE PHASE WIRING SPECIFICATIONS

A. Submit manufacturer's literature and technical data before starting work.

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

Outdoor Power Transmission & Distribution

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Temporarily Approved Solar Photovoltaic System Electrical Schematics

Type MMV-WP Medium Voltage Wind Power Cable

Battery Cables. Wire & Cable

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

THREE PHASE WIRING SPECIFICATIONS

Wire and Cable Division

Photovoltaic Solar Plan Review

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Residential Photovoltaic (PV) Packet

Transcription:

STABILOY Feeder Solutions Primary, Secondary, Post-Secondary Education Facilities

Introduction At Alcan Cable your children s safety is our top concern. That is why our STABILOY aluminum alloy feeder cables are installed with confidence in a variety of educational facilities in North America including: K-12 buildings and classrooms Secondary education facilities including classroom buildings, research centers, auditoriums, libraries and dormitories Athletic facilities including stadiums, practice field lighting, scoreboards and ancillary buildings Electrical retrofit in historic university buildings The STABILOY brand of products includes MC Cable, FeederPlex HS XHHW-2 cable, and single conductor WIDESTRIPE HS XHHW-2 cable, which are designed to distribute power throughout the building. Each of these cable solutions provides significant cost savings and reliable performance. STABILOY MC Cable offers a durable interlocked aluminum armor to protect the electrical conductors from damage, while allowing flexibility in construction and design. The all-in-one assembly of MC Cable makes it a cost-effective solution for electrical retrofits in historic buildings. STABILOY single conductor WIDESTRIPE HS XHHW-2 cable can be used in EMT, PVC or other types of conduit. Our FeederPlex HS XHHW-2 cable is a factory-plexed assembly of XHHW-2 conductors that allows for fast and easy cable pulls while eliminating the need to pull multiple conductors in parallel. So whether you are installing in conduit or not, STABILOY aluminum alloy feeder cables offer you a safe, reliable and cost-effective solution for distribution feeder applications. Quality is never a question with STABILOY cables. In fact, Alcan Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Each STABILOY single conductor and FeederPlex assembly is tested using the application of high voltage while immersed in water, ensuring that the insulation has zero defects. The superior performance of STABILOY aluminum alloy cables has been validated by independent research. The Georgia Power Research Laboratory conducted a study comparing STABILOY feeders to copper conductors. The results of the study show that connections installed on AA-8030 aluminum alloy performed as well as or better than connections installed on copper conductors of equivalent ampacity in the current cycle submersion test. STABILOY aluminum alloy is readily available, infinitely recyclable and is manufactured in an environmentally responsible manner. STABILOY feeders contain no heavy metals and are RoHS* compliant, and the cable jackets are free of lead and cadmium stabilizers. Alcan Cable XHHW-2 insulation provides a longer life than THHN/THWN-2, thereby extending the total life of the installation and reducing waste. There s no question: green construction is the building trend of the decade. However, in today s tough economy, it is crucial to cut costs while considering the environmental impact of our building material choices. By including STABILOY MC Cable in your project specifications, the savings you realize can be used to defray the cost of energy-saving devices and accelerate the payback of your green building. *Denotes compliance to RoHS, Directive 2002/95/EC. For more information on Alcan Cable, call 800-347-0571.

APPLICATION STABILOY feeder cables are UL listed and can be used for services and feeders. Service and feeder conductors to the main distribution center in a variety of buildings including: administration offices, classrooms, dorms, cafeterias, and gymnasiums. Feeder conductors for power distribution to the panel throughout a variety of building constructions including: wood stud, metal stud, concrete poured and cinder block. Feeder circuits for a variety of specialized equipment and HVAC services. Temporary services for power throughout the construction phase. Our Metal Clad cable with PVC jacket can be used in exterior locations including wet locations and those exposed to sunlight. PROJECTS LIST Hiawatha Elementary School Richland, Washington Hillside School District Hillside, New Jersey Jenks Public School Math & Science Facility Jenks, Oklahoma University of North Texas Denton, Texas Green County Technical High School Paragould, Arkansas Alcorn State University Jefferson, Mississippi Deloitte Conference & Learning Center Westlake, Texas SPECIFICATIONS Field Application Engineers are on staff to help you navigate the electrical specification process including takeoffs and voltage drop calculations. FAEs also serve as a resource for specification changes, value engineering proposals and technical questions. To gain the maximum value benefit on your project, specify 8000 Series aluminum alloy as an alternative in the Master Electrical Specification. A sample specification is included below for reference. 600-VOLT INSULATED CONDUCTORS A. All branch circuit conductors and feeder conductors 10 AWG and less shall be soft-drawn annealed copper with conductivity of not less than 98% IACS at 20 degrees C (68 degrees F). Feeder conductors greater than 10 AWG copper may be converted to aluminum at the contractor s option. Feeders shall be as defined in the NEC. The contractor shall be responsible for increasing the conductor and conduit sizing, if necessary, when aluminum conductors are substituted for copper. The ampacity of the aluminum conductor shall be adequate for the load served and sized appropriately for the overcurrent device. The conduit fill shall not exceed NEC requirements. B. Conductors 10 AWG and smaller shall be solid and conductors 8 AWG and larger shall be stranded. Minimum wire size shall be 12 AWG unless otherwise noted on the drawings. C. All wire and cable shall be permanently marked to indicate size, voltage and type temperature rating in accordance with NEC Article 310 and applicable product standards. D. Provide factory colored insulation for conductors for 10 AWG and smaller or color code larger insulated conductors with an approved field applied tape. E. Aluminum conductors shall be as follows: Type XHHW-2: For dry and wet locations, maximum operating temperature 90 C. The conductor shall be compact stranded AA-8000 series aluminum with black cross-linked polyethylene insulation. The cable shall meet the requirements of Federal Specification JC-30B. The conductor shall comply with ASTM Standards B800 and B801. ALUMINUM CONNECTORS AND TERMINATIONS A. All connectors and terminations shall be UL listed for use with aluminum conductors. All connectors and terminations shall comply with UL Standard 486A-B and be marked AL7CU for 75 C circuits or AL9CU for 90 C circuits. B. All connections and terminations shall be made in accordance with the connector or equipment manufacturer s recommendations. C. Tighten electrical connectors and equipment, including screws and bolts, in accordance with manufacturer s published torque tightening values. Where manufacturer s torquing requirements are not indicated, tighten connectors and equipment to comply with tightening torques specified in UL Standard 486A and B.

STABILOY aluminum alloy features a unique composition of metals that is specially engineered to give you the same performance as copper with less weight, lower cost and greater flexibility. Conductivity It s true. Aluminum conductors carry twice the current per pound as copper conductors. This is a significant performance advantage that utilities depend on for the national power grid. In feeder cable applications, the same performance advantage of aluminum can be realized by using STABILOY aluminum alloy instead of copper. Insulation No question about it. STABILOY aluminum alloy conductors feature superior insulation. In fact, the cross-linked polyethylene (XLPE) insulation on STABILOY conductors performs better in cold impact, wet electrical and long-term aging tests. This makes it a better insulation for every application. Termination Why mix metals? STABILOY aluminum alloy conductors terminate safely with industry standard dual-rated aluminum lugs. The similar metals connection eliminates thermal expansion mismatch, which translates into a safe and reliable termination. Quality It s a fact. Alcan Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Because STABILOY aluminum alloy feeder cable is 100% tested for quality its reliability, durability and safety are all guaranteed! Performance High-quality STABILOY aluminum alloy features a unique composition of metals that is specially engineered for superior performance in building feeder applications. Confidence You can rest assured. If aluminum is the utility companies preferred choice for carrying power all the way from the generator to the grid, it s the right choice for the last 100 feet of power delivery feeder cable. Ease-Of-Use STABILOY aluminum alloy feeder cable is much easier to install. Maintenance for STABILOY and copper is equal. This makes it more time-efficient and more cost-effective as well. Value At twice the ampacity per pound, not only is aluminum more cost-effective than copper, but the price of aluminum is much more stable than the price of copper. Sustainability Aluminum alloy is readily available and infinitely recyclable. In addition, STABILOY aluminum alloy conductors are manufactured in an environmentally responsible manner.

Products MC Cable An all-in-one XHHW-2 conductor assembly with phase-identified conductors and a bare equipment grounding conductor. The assembly is a no conduit solution that provides labor and material savings of up to 50% over copper in conduit. STABILOY MC Cable is available with and without a PVC jacket. FeederPlex HS XHHW-2 Factory-plexed assembly of aluminum alloy XHHW-2 conductors with specially designed XLPE insulation that allows for fast and easy pulling. Designed with phase identification for safer connections and delivered on one reel to the job site. STABILOY FeederPlex HS significantly reduces installation time and effort during the pull, and minimizes site management. WIDESTRIPE HS XHHW-2 A single conductor aluminum alloy feeder cable with a specially designed XLPE insulation that allows for fast and easy pulling. Phase identification on the conductor consists of three wide color stripes embedded within the surface of the insulation. The insulation on STABILOY WIDESTRIPE HS (High Speed) XHHW-2 conductors reduces pull force by 42% compared to the installation of regular XHHW-2 using pull lube. STABILOY XHHW-2 A single conductor feeder with cross-linked polyethylene (XLPE) insulation that provides better performance than THHN insulation in hot and cold weather conditions, wet electrical tests, higher short circuit temperatures and long-term aging tests. CASE STUDIES FPO Cedar Ridge High School Round Rock, Texas Building Construction: Concrete with stone, metal and glass facade Walker Engineering Austin Why STABILOY? Confidence in aluminum alloy feeders with a preference for STABILOY FPO Texas A&M Agriculture Headquarters Bryan, Texas Building Construction: Concrete with stone, stucco and glass exterior Britt Rice Electric College Station Why STABILOY? Reliability of STABILOY products on previous projects www.cable.alcan.com

Alcan Cable Division of Alcan Products Corporation Three Ravinia Drive, Suite 1600 I Atlanta, GA 30346-2133 770-394-9886 I Fax 770-677-2609 For more information on Alcan Cable, go to www.cable.alcan.com or call 800-347-0571. BW-0101 4/2011 2011 Alcan Cable. STABILOY is a registered trademark of Alcan Cable, a division of Alcan Products Corporation. All rights reserved.