TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Similar documents
TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 12 PORTABLE PACK AND ASSOCIATED CONTROL MODULES USER GUIDE (Part # LIT A)

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

SAVE THESE INSTRUCTIONS

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

FD Conveyor for FD 260 Tabber

SAVE THESE INSTRUCTIONS

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

CTFRP Series Power Supplies

PSX-240 Enclosed Autotransformer Installation Manual

Portable Pack USER MANUAL

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Installation Instructions

GMT Fuse Panel Installation Guide

C3000 SIGNAL TRANSMITTER. Introduction

Florham Park, NJ USA Call (ASCO) for sales or service

Transformer Installation, Operation, and Maintenance Manual

Model 8144NC Fresh Air Ventilator

Wireless Dimmer Installation and User Guide

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Installation Instructions

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

10 Commercial, Industrial, Agricultural Services

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

Pump Installation and Service Manual HRS Hydromatic Retractable System

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

GP Dimming Panels 230 Volt (CE)

INSTALLATION INSTRUCTIONS

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Manual Transfer Switch

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

MODEL ELC-12/60-D BATTERY CHARGER

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

Patient Care Facility

Installation Instructions Electric Heaters 5 20 kw

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS

ELECTRO-MECH SCOREBOARD CO.

SAVE THESE INSTRUCTIONS

Florham Park, NJ USA Call (ASCO) for sales or service

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

BZ Products Inc. U.S.A.

Safety, Installation and Service Manual Models 1952, 1953 & 1972

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Wired Maestro Local Controls

Quick Start Guide TS 910 & TS 920

SAVE THESE INSTRUCTIONS

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

30A SMART ENERGY MANAGEMENT SYSTEM TM

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Operators Manual. Recirculating Chiller /06/08

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

User s Guide. Includes Mounting, Installation, and Product Registration

O & M Manual for the EATON Generator Ready Loadcenter

LP Dimming Panels. GRAFIK Systems

SPC-PANEL Simplex, Single Phase Pump Control Panel

Sensor3 Rack (SR3 and HSR3 Series) Installation Manual

Environmental Series Air Curtains

SIGNAL WORDS QUALIFIED PERSON

Model LA 4100 Time Delay OFF Controller

Installation Instructions

MaxLite LED UTILITY WRAP FIXTURES

A2P Single Phase Automatic Industrial Battery Charger

TPM/GMT Panel Installation Guide

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

GP Dimming Panels 230 Volt (CE)

INSTALLATION AND OPERATING INSTRUCTIONS

Model LA 4300 Time Delay OFF Controller

RK Standby Battery Operator s Manual

SCR Power Controllers

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

High Velocity Series Air Curtains

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

LED Light Bar. Series LLB. Installation Instructions

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Transcription:

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user for operation and maintenance instruction. Copyright March 2002 Leviton Manufacturing Co. Inc.

Table of Contents Unpack pack(s)... 1 Mount pack(s). 1 Terminate conduits. 3 Convert bussing to single-phase 3 Pull power, load and control conductors to the pack(s).. 4 Connect power feeders. 4 Connect load conductors.. 5 Low-voltage application notes.. 5 Connect control conductors.. 6 Seal unused openings... 6 Install control module(s) 7 Set thumbwheel switch(es)... 7 Set Non-dim switches 8 Apply power and check. 8 Install dimmers 8 Install filler modules... 9 Test loads 9 Close door 9 Maintenance and Specifications.. 10 Warranty. 11

TOPAZ 12 WALL PACK INSTALLATION INSTRUCTIONS The TOPAZ 12 Wall Packs are easy-to-install front-wired electrical distribution panels and are connected similarly to a circuit breaker panel. These instructions will tell you how to mount, wire, assemble, test and maintain TOPAZ 12 Wall Packs. The instructions in this manual are provided in the order of installation. Step 1 - Unpack pack(s) In each pack box you will find one TOPAZ 12 Wall Pack, two keys, and one installation manual (this document). Dimmer and control modules are shipped separate. Leave control module and dimmer modules in their packing and store in clean, dry place until ready to perform Step 10. After unpacking, please inspect the pack for any possible shipping damage. Document any shipping damage and contact the freight company and Leviton. Step 2 - Mount pack(s) Packs must have 6" (152mm) minimum clearance above fan and 36" (914mm) minimum clearance in front for proper cooling and access. Packs should be located in a clean, dust free environment, within proper operating temperature range. See Specifications - Table IV, pg 10. One pack per location: Note: If you have a multiple pack or semi-recessed installation, skip ahead to the appropriate section for instructions. Locate stud or a secure framing member in wall where pack is to be mounted. Using the dimensions shown in Figure 1 mark location of one column of 2 mounting holes on wall over stud. Fasten pack to wall with appropriate fasteners. Note: Fully-loaded pack weighs 40 pounds (18.2 Kg.), not including wire weight. Figure 1 - Surface Mounting Dimensions Two packs mounted together: Locate two studs or secure framing members on 16 (406mm) centers in wall where packs are to be mounted. Note: If appropriately spaced studs or framing members cannot be located, packs may have to be mounted on Unistrut or equivalent supporting channels. Skip ahead to the next section for instructions. Using the dimensions shown in Figure 1 mark location of one column of 2 mounting holes on wall over each stud. Page I

Remove the 3 bolt hole knockouts and the ¾ T.S. conduit knockout on the mating sides between the two packs. Bolt packs together with ¼ bolts, internaltooth lockwashers (one under bolt head and one under nut), and nuts (not supplied). Bush control wire knockout with ¾ T.S. chase nipple or equivalent (not supplied). Fasten packs to wall with appropriate fasteners. Note: Two fully loaded packs weigh 80 pounds (36.2 Kg.), not including wire weight. Packs mounted to Unistrut supports: Note: If more than two packs are mounted together the mounting holes are no longer on 16" centers. Using the dimensions shown in Figure 1 mark the wall with the locations of two horizontal mounting channels. Fasten two mounting channels, Unistrut P3300T or equivalent (not supplied), to the wall at each vertical stud or framing member. Insert Unistrut nuts (not supplied) on 14 (356mm) centers in each channel for each pack section to be mounted. Remove the 3 bolt hole knockouts and the ¾ T.S. conduit knockout on the mating sides between adjacent packs. Bolt packs together with ¼ bolts, internal-tooth lockwashers (one under bolt head and one under nut), and nuts (not supplied). Bush control wire knockout with ¾ T.S. chase nipple or equivalent (not supplied). - Mount the pack assembly to the mounting channels using bolts and lockwashers. Semi-Recessed Packs: Locate semi-recessed mounting kit, Model Number 600-906 (shipped separately). Mount the two mounting brackets to the sides of the pack with the 10-24 screws and lockwashers supplied. Refer to Figure 2. Mount the pack in the wall to two studs or other suitable structure with #12 flat head wood screws (not supplied) or other suitable fastener. Adjust the mounting brackets if necessary to make sure the back of the black extrusion is at least 1/8 (3.175 mm) in front of the finish wall surface. - Skip to Step 3 for conduit installation instructions and then return to this step. - Attach the two vertical parts (countersunk holes) of the trim frame to one of the horizontal parts (tapped holes) with 2 black flat-head 6-32 screws (supplied). - Set the other horizontal trim frame part in place on top of the cabinet behind the blower grill. - Install the pre-assembled trim frame from the bottom of the pack and screw to the top part with the remaining screws. If frame fits loosely, bend the tabs provided in the vertical parts with pliers to press against pack wall. Figure 2 - Semi Recessed Mounting Dimensions Page 2

Step 3 - Terminate conduits See Figure 3. Terminate a feeder conduit at the top or bottom conduit knockouts of each pack. See Table IV, page 10, for knockout size and location. Terminate load conduits at top and/or bottom conduit knockouts of the pack which the loads will be connected. In most cases this means the first 12 loads should connect to the first pack, the next 12 loads should connect to the second pack and so on. Terminate the control conduits at the top, bottom or side conduit knockouts of the first pack. Bottom or side access is preferable. Top Conduit Knockouts Bottom Conduit Knockouts Figure 3 - Conduit Entry Areas Step 4 - Convert Bussing To Single-Phase Packs are shipped ready to accept three-phase, 4 wire feeders. If feeder is single-phase, 3 wire, convert bussing as follows. Otherwise skip to the next Step (5). Loosen the four bolts securing the feeder lugs/bussing. See Figure 4. Revolve one of the jumpers connecting the two sections of Ø B bussing to the Ø A bus locating it between the Ø A lug and bus. Revolve the other jumper to the Ø C bus in the same manner. Tighten all four bolts. Figure 4 - Bus Conversion Page 3

Step 5 - Pull power, load and control conductors to the pack(s) - Pull all conductors into the packs. Feeder and load conductors must be rated for 90 C, and be copper. Control conductors must be rated for operation at 85 C and are all Class 2. Step 6 - Connect power feeders - Connect the feeders at the phase, neutral and ground lugs and tighten according to Table I. See Figure 5 for lug locations. (If pack has been converted to single-phase, only lugs A & C will be terminated.) A N NEUTRAL LUG B C PHASE LUGS GROUND LUG Figure 5 - Power Lug Location Table I - Line Terminal Torque Ratings 14 AWG - 10 AWG 35 in.-lbs. (2-6 mm 2 ) Line and Neutral Lugs 8 AWG 40 in.-lbs. (rated for copper wire only, (10 mm 2 ) and for 90 C ampacity wire) Ground Lug 6 AWG 4 AWG 45 in.-lbs. (16-20 mm 2 ) 2 AWG - 1/O AWG 50 in.-lbs. (35-50 mm 2 ) Page 4

Step 7 - Connect load conductors Follow the instructions here for each dimmer type you are installing. 15/20 AMP INCANDESCENT & LOW-VOLTAGE LOADS: - Referring to Figure 6, connect the load conductor for the first (upper) dimmer to the upper load terminal, and the second load conductor to the lower load terminal. Terminate their respective neutral conductors to the adjacent neutral terminals located directly behind the load lug. Tighten all lugs according to Table II. Terminal 15/20A Incandescent, and Low-Voltage Load 1A 1 1B 2 2A 3 NEUTRAL BUS LOAD TERMINAL 4B 8 Table II - Load Terminal Torque Ratings Figure 6 Load Terminal Wiring LOAD TERMINALS (rated for copper wire only, and for 90 C ampacity wire) 14 AWG - 2 AWG 50 in.-lbs. (2-6 mm 2 ) LOW-VOLTAGE APPLICATION NOTES: When using TOPAZ 12 dimmer modules with transformer loads, the kw rating becomes the kva rating. VA ratings are found by multiplying the input voltage (12OV) by the current flowing in the transformer primary (120V side) for all transformers connected to the dimmer module. When calculating VA load keep in mind that transformer losses add many VA to the published VA load rating of the transformer. When current cannot be measured, derate the kw rating of the dimmer module by 25% and add up the kw ratings of the lamps involved. Caution: Operation of a dimmed transformer-loaded circuit with all lamps inoperative or removed may result in current flow or voltage in excess of normal levels. To avoid possible transformer overheating and possible premature transformer failure, Leviton strongly recommends the following: a. Do not operate dimmed transformer-loaded circuits without operative lamps in place; and b. Replace burned out lamps as quickly as possible; and c. Use transformers which incorporate thermal protection or fuse transformer primary windings to prevent transformer failure due to over-current. For best results transformers employed in transformer-loaded dimmed circuits should be high-quality units well varnished and with an extra margin of magnetic material. Page 5

Step 8 - Connect control conductors Follow the instructions below for the type of control you are installing. Note: All control terminals accept 24-14 AWG. (.02-2 mm 2 ) wire and are all Class 2. DMX512 or CMX: A Remote" or Universal" TOPAZ 12 Control Module is provided for each pack. Connect the control wires to the 5-position terminal strip in each pack as shown in Figure 7. (For ease of assembly, remove and discard TB2.) CONTROL CONSOLE, DLR INTERFACE OR PREVIOUS PACK Figure 7 TB3 ANALOG 0-10V: For analog 0-10V applications, a Universal Control Module must be used. Locate the terminal blocks inside the Pack labeled 0 to 10VDC Dimmer Control Inputs. Connect the incoming control wires to terminals 1 12. Connect to at least one common terminal per group of 12 inputs. Step 9 - Seal unused openings Seal any unused mounting and conduit access holes in the pack. This is necessary to maintain proper ventilation while the pack is operating. Page 6

Step 10 - Install control module(s) Unpack the control module(s). Set the 3 DIP switches labeled S1 on the printed circuit board (See Figure 8) as follows: SW1 down SW2 up SW3 down If the control module is a Remote type, verify that jumper JP5 is in the REM position. Control Module Type 120V Module No. TOPAZ 12 Remote LEC2102 LEC2105 TOPAZ 12 Universal 600-902 600-904 240V(Foreign Electric Service Only) If the control module is a Universal type, verify that the AMX/DMX switch is in the DMX position and that the Status/Other switch is in DMX position and that the Status/Other switch is in the Other position. See Figure 9. Install the appropriate control module in the bottom slot of each pack by sliding it in until it is fully seated. 3 GANG DIP SWITCH (S1) JUMPER (JP5) CONTROL FUSES (F1 3) RACK NO. THUMBWHEEL SWITCH TEST SWITCH POWER INDICATOR Figure 8 - Remote Control Module NON-DIM SWITCHES STATUS/OTHER SWITCH Step 11 - Set thumbwheel switch(es) AMX/DMX SWITCH Figure 9 - Universal Control Module Set the thumbwheel switch(es) on all TOPAZ 12 control modules according to Table III on next page. See Figure 8 (Pack 1 is usually the left-most pack). Page 7

Table III - Thumbwheel Switch Settings PACK NUMBER THUMBWHEEL SWITCH NUMBER 1 0 2 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 15 14 16 15 Step 12 - Set Non-Dim switches Note: if control module is not a Topaz Universal type, skip to the next step (Step 13). Switch Non-Dim switches to select which dimmers are to operate in the Non-Dim mode. The Non-Dim mode switches are located on the left-hand side of the top printed-circuit board on the Universal Control Module. See Figure 9, page 7. In the off (left) position, the channel will function as a dimmer. In the on (right) position, the dimmer will function as a non-dim (fully off or fully on). Only the first twelve switches are used. CAUTION: Do not operate these switches while the pack is energized. Step 13 - Apply power and check Apply power to the pack. Power indicator LED should be lit on the control module. If the LED is not lit or is flashing, at least one control fuse is blown or one power leg has no voltage present. Check the control fuses on the rear of the control module. Check the feeder wiring with a meter, correct the problem and restore power to the pack. See Figure 8. CAUTION: High Voltage - all measurements with a meter and other operations within the pack must be with the pack de-energized or by a qualified electrical installer exercising extreme care. Model Max Circuit No. Load Voltage Breaker 166-361 166-362 166-364 1.8kW 2.4kW 2.5kW *(foreign electrical services only) 120 120 220/240* 15A 20A 15A Step 14 - Install dimmers Unpack all dimmers. Slide a dimmer module into each dimmer slot beginning with the bottom dimmer slots first and building upward. Push the dimmers in until they are seated firmly. Page 8

Step 15 - Install filler modules If there are less than 6 dimmer modules for a pack, unpack and install filler modules (Part Number 166-360) in slots where there are no dimmers. This must be done to insure proper cooling while the pack is in operation. Filler modules look the same as dimmers, but do not have circuit breakers and are installed the same way. NOTE: Pack should not be operated without all spaces filled. This insures proper cooling. Step 16 - Test loads Switch all dimmer circuit breakers OFF first (switched to the right). Switch the test switch on the control module to the TEST position. See Figure 8, page 7. This will turn on the fan. Switch on the circuit breaker of each dimmer, one at a time, by moving the breaker handle to the left. Verify that the load is on and the dimmer is operating. When testing is completed, switch the test switch on each control module to the NORMAL position. This will turn off the fan and all dimmers. Verify that all circuit breakers are in the ON position (switched to the left). Step 17 - Close door If desired, label circuits for easy identification later. Close the front access door. This will aid in proper cooling of the pack and restrict access to the dimmer circuit breakers. See Figure 10. ACCESS DOOR LOCK DIMMER AND FILLER MODULES ACCESS DOOR CONTROL MODULE Page 9 Figure 10 - Assembled Pack

MAINTENANCE Once each year (or more often, if necessary) clean any accumulation of dust from the fan grills, dimmer module air-intake openings and control module front. This may be done with compressed air or a vacuum. Also check all wire terminations for tightness - refer to Tables I and II for torque ratings. Caution: Do not perform the above maintenance with the rack energized. Table IV - Specifications (per single pack section) Pack Capacity: Dimensions: Weight: Conduit Knockouts Top and Bottom Load/Line: Sides,Control Signal: Maximum Fan Noise Rating: Maximum Ambient Operating Temperature: Maximum Operating Humidity: Maximum Feeder Size: Nominal Input: 120 V Circuits: 240V Circuits: (FOREIGN ELECTRICAL SERVICE ONLY) Pack Enclosure: 12 Circuits, 20 Amp max. per circuit. 14-1/4" H x 14" W x 9" D (361.95mm H x 356mm W x 229mm D) Empty - 22 lbs. (10 Kg.) Full - 40 lbs. (18.1 8 Kg.) 4 concentric 1/2", 3/4", 1 ", 1-1 /4" T.S. 1 concentric 1", 1-1/4", 1-1/2" T.S. 1 concentric 1/2", 3/4" NC33 40 C (104 F) 90% without condensation. 125 Amp. 120/208V, 3Ø, 4W, 50/60 Hz, or 120/240V, 1Ø, 3W, 50/60 Hz. 240/415V, 3Ø, 4W, 50/60Hz, or 240/480V, 1Ø, 3W, 50/60Hz NEMA Type 1 for indoor use only (utilizer dans un endroit a I'abri) Phase-to-Neutral Operating Voltage: 120V + 10% or 220/240V + 10% Operating Frequency: 50 ±.5Hz or 60 ±.5Hz For further information on the operation of the TOPAZ 12 Wall Pack refer to the user guides and operations manuals of the control console or architectural control stations that will be used in conjunction with this product. For additional assistance, please contact the NSI Technical Support Line, Monday through Friday, 8:00 am to 5:00 pm PST. 1-800-864-2502 Page 10

LEVITON-NSI DIVISION TWO-YEAR LIMITED WARRANTY Leviton-NSI warrants new Leviton-NSI electronic control and dimmer products to be free from defective materials and workmanship for a period of two years from the date of purchase to the original owner when purchased from an authorized Leviton-NSI dealer. Fixtures, lamps and gel material are not covered under this warranty. The purchaser is encouraged to complete and mail to Leviton-NSI the product registration card enclosed with each product. Leviton-NSI products that have been subjected to accident, alteration, abuse or defacing of the serial number are not covered by this warranty. The normal wear and tear of items such as knobs, jacks and switches are not covered under this warranty. If your Leviton-NSI product requires service during the warranty period, Leviton-NSI will repair, at its option, defective materials provided you have identified yourself as the original owner of the product to Leviton-NSI or any authorized Leviton-NSI dealer. Transportation charges to and from an authorized dealer or the Leviton-NSI factory for repair shall be the responsibility of the owner. All products returned to Leviton-NSI must have a factory return authorization number issued prior to shipping. Leviton-NSI is not liable for any incidental or consequential damages resulting from defect or failure other than repairs of the Leviton-NSI product subject to the terms of this warranty. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty is expressly in lieu of all other agreements and warranties expressed or implied except as may be otherwise required by law. 20497 SW Teton Avenue Tualatin, OR 97062 503-404-5500 fax: 503-404-5600 Page 11