Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Similar documents
SECTION PANELBOARDS

Lighting Panelboards. P2 Panelboards

A. Submit manufacturer's literature and technical data before starting work.

Design Guide for Integration of Fixed-Mount Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Enclosed Circuit Breakers

Application guide. Tmax Link OEM UL 891 Switchboard Program

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Quik-Spec Electrical Gear

Cutler-Hammer. January 2001

Bussmann series Quik-Spec Coordination Panelboard

Switchboards Instant Service

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Type MP-T Type MP-HT Type MP-MT

Selection and application guide

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

NEMA Contactors & Starters (Freedom)

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

IN2 Enclosed Switches and Circuit Breakers

Medium Voltage Metal-Enclosed Switches

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Medium Voltage Metal-Enclosed Switches

POWER PRODUCT Meter Centres Contents

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

SECTION MOTOR CONTROL

US CATALOG. ProLine Panelboard and breakers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Design Standards NEMA

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Control Circuit Protection

Save time and money, plus increase home value!

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Bulletin 1489 Circuit Breakers. Selection Guide

22.000A IR. Catalog Number. Price $

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

OTEC Transfer switch open transition

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Series L9 UL-489 Miniature Circuit Breakers

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Revised P1 Panelboards

Series KTU7 UL489 Molded Case Circuit Breakers

Technical data OT16E3 OT160E3 UL & CSA

Cutler-Hammer. January 2001

Engine Generator Circuit Breakers

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

QMB Fusible Panelboards

Big performance in a small package

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Transfer switch OTEC and OTECSE open transition

PowerPact B. Molded case circuit breakers and switches from A

Series KTU7 UL489 Molded Case Circuit Breakers

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Underwriters Laboratories Inc. Marking Guide. Panelboards. July 2004

Enclosed Circuit Breakers

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Molded Case Circuit Breakers

Design Standard. Purpose: Design Standard:

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Big performance in a small package

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Enclosed Circuit Breakers

Quik-Spec. Section Contents

Quick Start Guide TS 910 & TS 920

Self-protected Combination Starters System PKZ 2-SP

Product Specification Sheet #3LD2.1

Eylander Electric Inc

General information about motor protection

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Tmax Molded Case Circuit Breakers

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Quik-Spec Coordination Panelboard Specifications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Tmax Molded Case Circuit Breakers

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

1489-M Circuit Breakers

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Panelboards Circuit Breaker / Lighting and Distribution

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Transcription:

Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers

Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip button. Field installable internal accessories increase flexibility. Field installable external accessories for handle blocking/ locking and interlocking. UL, CSA, and NOM certified for use anywhere in the NAFTA market. Modernization of previous breaker accessories in order to comply with QR Circuit Breakers. 2

General Information The Siemens QR circuit breaker has a compact design for use in North American markets. Features include the ability to handle higher interrupting ratings and higher inrush currents, as well as available UL listed field installable internal accessories. Applications: Implemented in load centers, panelboards, switchboards, meter centers, and modular metering Use by OEMs in control panels and a variety of other 240V applications Operating Conditions: Standard QR breakers are calibrated at 40 C ambient temperatures. Operation at higher temperatures will require derating. Enclosures are available for installing QR breakers in factory environments (NEMA 1, 12), as well as outdoors (NEMA 3R, 4X, and 4X 316 Stainless Steel). 250A Frame UL489 CSAC22.2 NOM003 Series Ratings HACR Rating 10 ka, 25 ka, 65 ka, 100 ka @ 240V AC Pushtotrip button ULListed Field Installable Internal Accessories Cablein, cableout design Enclosures available in NEMA 1, 1R, 4X, and 4X 316 Stainless Steel Reverse Feed 3

General Information QR2 Breaker 10kA * QRH2 Breaker 25kA * Ampere Rating 2 Pole 3 Pole Ampere Rating 2 Pole 3 Pole 100 QR22B100 QR23B100 100 QRH22B100 QRH23B100 125 QR22B125 QR23B125 125 QRH22B125 QRH23B125 150 QR22B150 QR23B150 150 QRH22B150 QRH23B150 175 QR22B175 QR23B175 175 QRH22B175 QRH23B175 200 QR22B200 QR23B200 200 QRH22B200 QRH23B200 225 QR22B225 QR23B225 225 QRH22B225 QRH23B225 250 QR22B250 QR23B250 250 QRH22B250 QRH23B250 HQR2 Breaker 65kA * HQR2H Breaker 100kA * Ampere Rating 2 Pole 3 Pole Ampere Rating 2 Pole 3 Pole 100 HQR22B100 HQR23B100 100 HQR22B100H HQR23B100H 125 HQR22B125 HQR23B125 125 HQR22B125H HQR23B125H 150 HQR22B150 HQR23B150 150 HQR22B150H HQR23B150H 175 HQR22B175 HQR23B175 175 HQR22B175H HQR23B175H 200 HQR22B200 HQR23B200 200 HQR22B200H HQR23B200H 225 HQR22B225 HQR23B225 225 HQR22B225H HQR23B225H 250 HQR22B250 HQR23B250 250 HQR22B250H HQR23B250H Load side lugs are supplied as standard. If both line and load side lugs are needed, add L to the end of the catalog number. Molded Case Switch Amperes Voltage Poles Interrupting Rating 250 240 3 100kA HQR23S250HA 4

Internal Accessories Shunt trips and auxiliary switches are operational devices that are contained within an addon module for the QR circuit breakers. Each module can be installed in the field. Shunt Trip A shunt trip is used to trip the breaker remotely. It is operated by providing voltage to the shunt trip coil. The coil in this device is designed to be energized momentarily, so included is a builtin limit switch which opens the coil circuit after the breaker trips. With the circuit breaker in the tripped position, voltage cannot be applied through the coil circuit due to the open contacts in the limit switch. The operational range of this device is (70 to 110%) of the marked voltage rating. Auxiliary Switches Auxiliary switches are used for remote indication of breaker contact position (ON or OFF). Each switch consists of "A" (normally open) and "B" (normally closed) contacts with a common connection. These devices are typically used for signaling purposes. QR breakers with accessories installed 5

Accessories Shunt Trip Control Voltage Shunt Trip Shunt Trip and Auxiliary Switch Combination AC DC 24 S07QR2 S07QR2A 120 240 48 S01QR2 S01QR2A Auxiliary Switch Contains (1) or (2) sets of A contacts and B contacts. Maximum Control Supply Voltage (V) Maximum Allowable Current (A) Single Auxiliary 1A 1B Contact Double Auxiliary 2A 2B Contact 250 AC /125 DC 5 AC / 0.5 DC A01QR2 A02QR2 Terminal Connectors Breaker Amp Rating (A) Type Wire Size Wire Grip Screw Torque #3 1/0 AWG Al/Cu 100 inlb (11.3 Nm) 2/0 AWG 300 Kcmil Al/Cu 225 inlb (25.4 Nm) #3 1/0 AWG Cu ONLY 100 inlb (11.3 Nm) 2/0 AWG 300 Kcmil Cu ONLY 225 inlb (25.4 Nm) Lug Aluminum Connector 100 250 Copper Connector 100 250 Compression Lug 100 250 #6 AWG 350kcmil Al/Cu N/A CCQ250 (Kit of 1) Lug Retainer 100 250 QRLUGRETAINR (Kit of 10)* 3TA1QR300 (Kit of 3) 3TC1QR250 (Kit of 3) * To move lugs from line side to load side QRLUGRETAINR is required. Copper Connector TC1QR250 Aluminum Connector TA1QR300 Compression Lug CCQ250 6

External Accessories Description Padlock Device HPLQR Mounting Screw Kit MSQR3 Handle Blocking Device HBLQR Handle Slidingbar Interlock SBMIQR Padlock Device HPLQRa Handle Block Device HBLQRb a Can be used to lock breaker handle in OFF or ON positions. b Can be used to block breaker handle in OFF or ON positions. 7 Mechanical Interlock

Panelboard Kits DEADFRONT MAIN END Panelboard Kits Works With Catalog Number Description Breaker Poles Phase Panelboard Type MBKQR1A RP1 Panelboard Kit for Main or Subfeed QR Breakers 1Phase 1 RP1 MBKQR3A RP1 Panelboard Kit for Main or Subfeed QR Breakers 3Phase 3 RP1 MBKQR1 P1 Panelboard Kit for Main or Subfeed QR Breakers 1Phase 1 P1 MBKQR3 P1 Panelboard Kit for Main or Subfeed QR Breakers 3Phase 3 P1 BBKQR1 P2 Panelboard Strap Kit for Branch Mounting of QR Breakers 2P or 3P P2 BBKQR2 P2 and P3 Panelboard Strap Kit for Branched Twin Mounting of QR Breakers P3 MBKQRFK P1/RP1 Horizontal Mount Space Filler Kit for 1Phase/3Phase QR P1/RP1 BBKQRP1FK P2 Horizontal/Vertical Mount Space Filler Kit for 1Phase/3Phase QR 1, 3 P2 BBKQRP2FK P3 Horizontal Dual Mount Space Filler Kit for 1Phase/3Phase QR 1, 3 P3 MBKQRC1FK C1 Main Position Space Filler Kit for 1Phase/3Phase 1, 3 C1 8

Enclosures NEMA 1 A general indoor, sheetsteel enclosure for use in normal atmospheres. Listed as service entrance equipment. NEMA 3R An outdoor, sheetsteel enclosure providing protection against driving rain, sleet or snow. Listed as service entrance equipment. NEMA 12 A specialindustry, sheetsteel enclosure for use in atmospheres containing particles of lint, dust, dirt, sawdust and other foreign matter. NEMA 4, 4X Stainless steel indoor or outdoor enclosure designed for use in areas where serious corrosion problems exist. They provide a degree of protection against windblown dust, rain, splashing water and hosedirected water. Available in both 304 Stainless Steel and 316 Stainless Steel, Meets NEMA Type 1, 3, 4, 4X, 12 and 13 requirements and UL 508 Type 4 and 4X requirements. NEMA 3R Enclosure QR2N3R3 9 Enclosure Type Mounting Poles Ampere Rating NEMA 1 Indoor (general duty) Surface 100 250 QR2N1S NEMA 1 Indoor (general duty) Flush 100 250 QR2N1F NEMA 3R Outdoor (rain, snow) Surface 100 250 QR2N3R3 NEMA 12 (particulate matter) Surface 100 250 QR2N12 NEMA 4X (corrosion, particulates, water) Surface 100 250 QR2N4X NEMA 4X 316 Stainless Steel (corrosion, particulates, water) Surface 100 250 QR2N4X316

Dimensions QR Frame Outline Drawing 3 Pole (All dimensions in inches) Bottom Top 10

Dimensions QR Frame Outline Drawing 2 Pole (All dimensions in inches) Bottom 11 Top

Application Data General In the application of circuit breakers, consideration should be given to the following factors: 1. 2. 3. 4. 5. Voltage of circuit. Ampacity of circuit. Frequency of power source. Operation conditions. Fault current available. Voltage of circuit The system voltage should not exceed the listed voltage rating of the circuit breaker, fuse, or switch. Ampacity of circuit The listed continuous current rating of the circuit breaker should not exceed the allowable ampacity of the conductors. Where the allowable ampacity of the conductor does not correspond to listed current ratings for fuse or circuit breakers, the next larger rating of fuses or circuit breakers is permitted providing it does not exceed the conductor ampacity by more than 25%. An exception to this rule is permitted for motor circuits or other circuits where high inrush currents may persist for an appreciable time. Frequency of power source Circuit breakers are calibrated for use on direct current of 4860Hertz alternating current. For frequencies above 62Hertz, some fuses, switches and circuit breakers must be derated. The derating varies with each type and size of protective device. Consult your local representative for specific information. having a rated ampacity greater than 125 amperes, only 75 C cable shall be used unless otherwise indicated on the circuit breaker label. Note: Exceptions to this rule are outlined in Article 11014C(1) and C(2) of the 2005 National Electric Code. Conductors should be derated in accordance with the Nation Electrical Code for both ambient temperature and continuous loading. Conductors which are loaded continuously should be derated to 80% of their allowable currentcarrying capacity except when supplied by an assembly including its overcurrent device that is listed for continuous operation at 100% of its rating. When the type of load is unusual, intermittent, or one which involves momentary peak currents such as motor loads, consideration should be given to the heating effect on the protective device over a period of time. The duty cycle of a motor which is started and stopped frequently may require a circuit breaker or fuses with a higher rating than an infrequently started motor. The presence of excessive dust, moisture, corrosive fumes, or explosive atmosphere requires the use of enclosures suitable for such atmospheres. For application in regions where fungus growth may occur, some circuit breakers should be treated with a fungus and moisture resistant material. Operating conditions Molded case circuit breakers and fuses are calibrated without any enclosure as specified by the \ Underwriters Laboratories, Inc. Sound engineering practice dictates that continuous loads should not exceed 80% of the breaker or fuse current rating for most applications. Fault current available The interrupting rating of the circuit breaker should be greater than the available short circuit current at the point of application. The short circuit current from some power sources, such as engine driven generators, is limited, and the protective device characteristics should be selected to clear such faults without delay. Electrical connections Molded Case Circuit Breakers are to be connected with 60 or 75 C wire for breakers having a rated ampacity of 125 amperes or less. For circuit breakers Some systems require a study of protective device characteristics to assure proper protection and coordination for any possible value of fault current. 12

Time Current Curve SIEMENS 200 A Time Current Characteristic Curve QR Frame, Types QR2, QRH2, HQR2, HQR2H Thermal Magne c Circuit Breaker 2 & 3 Pole For applica on and coordina on purposes only. Based on 40 C ambient, cold start. Connected with 4 feet of rated wire (75 C) per terminal. Tested in open air with current. Types QR2, QRH2, HQR2, HQR2H 60Hz 240 Volts Instantaneous Trip Table Rating Amperes 100 175 200 250 Fixed Instantaneous Trip Amperes 1000 2000 1500 2500 Interrup on Ra ngs Breaker Type Time in Seconds QR2 QRH2 HQR2 HQR2H Symetrical RMS Amperes 240 Volt 10 ka 25 ka 65 ka 100 ka 814497TC200 rev. 1 Aug 2016 13 Current in Amperes X 10 Siemens Industry Inc. Norcross, GA, 30092 The above TCC is for 200A only. TCC s for different amperes are available on www.usa.siemens.com/qr

Notes: 14

Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 18002414453 info.us@siemens.com Subject to change without prior notice Order No.: CBBRQRBPG0117 All rights reserved Printed in USA 2017 Siemens Industry, Inc. Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.