UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

Similar documents
UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

SPA AGM VRLA batteries

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Aluminum Capacitors, Power High Ripple Current, Screw Terminals

BOOST POWER 1212 Product Description

Multi-Mover Charger for model L25

Galaxy VM. Battery Breaker Box Installation 09/

c-go 24V/6A 24V/8A 24V/12A

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

FAT. FAT Battery Range FIAMM.COM

PowerSafe OPzV Operation Guide for Solar Applications

Powerware Vdc Extended Battery Cabinet User s Guide.

Operating Instructions

Duo Battery Charge Controller

PowerSafe OPzV Operation Guide for Solar Applications

Nickel Metal Hydride Battery Pack. User Handbook

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

SBC / 2140 / Stage Battery Charger User Manual

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

EUROBAT EUROBAT GUIDE FOR MOTIVE POWER VRLA BATTERIES

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Pure Lead-Tin Technology

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

1. Production Features

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Solid Tantalum Surface Mount, TANTAMOUNT, Molded Case, Very Low DCL

Datasheet / Product specification Model: Solar AAA

Galaxy Receiving and Unpacking 09/

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

M Series External Battery Frame. User Guide

Uninterruptible power supply Supply MEg101.4

EcoSafe EOPzV. Operation Guide for Solar Applications

Ni-Cd Battery Product Specification

C3 Operating Instructions

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications


Technical data sheets

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

DECOUPLING MODULE. Input to output voltage drop

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 24V, 10A, DC-UPS 1/21.

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

SECTION

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

High Voltage Ceramic DC Disc Capacitors with Axial Leads, 10 kv DC to 30 kv DC

SCC-MPPT Solar Charge Controller

Smart Battery Charger

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Range. Alcad Single Cell Range. Powerful assurance for maximum operating reliability

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

CTC Battery, Inc. Lithium Iron Phosphate Battery Specification

PowerStor Standby Battery Systems

SCC-MPPT Solar Charge Controller

SCCP PWM Charge Controller/Load Manager Owner s Manual

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Micro. Fully charged. Charging Keepower MICRO Nominal battery voltage 12V Charge current 0.8 A. Keepower Battery Charger.

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Surface Mount Multilayer Ceramic Chip Capacitors for Non-Magnetic Applications (Epoxy Bonding)

NTC Thermistors, 2-Point Radial Leaded, Automotive Grade

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

CELLYTE 12 PLF & 12PLT Range

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

SECTION A Division of Exide Technologies

CX Series User s Manual

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

Surface Mount Multilayer Ceramic Chip Capacitors for Commercial Applications

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SCC-MPPT Solar Charge Controller

up to 63 A (1 module per pole)

Bulletin 1606 Switched Mode Power Supplies

SL10 SL10 SOLAR LED STREET / PARKING LOT LIGHT 10W,15W, 20W, 25W LED Lamp & Complete Solar Sytem

EASY CHARGE Weather-resistant fixed mount Battery Charger

FL20 Solar Bus Shelter / Transit Light System 10W, 15W, 20W LED Lamp(s) & Complete Solar Sytem

Battery charger , A, B

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

POWER SUPPLY SHORT-FORM DATA MAJOR AGENCY APPROVALS

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

EU Regulation for Premium Efficiency IE3 motors 2, 4, 6 poles efficienza

Phoenix Inverter

Sealed Lead-Acid Batteries

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

Transcription:

U-Series BATTERY REPLACEMENT Maintenance-free VRLA Lead-Acid Battery AGM (Absorbent Glass Mat) Technology Can Be Installed in Any Orientation Except Permanently Inverted 1. GENERAL DESCRIPTION The is a non-spillable maintenance-free VRLA lead-acid battery with absorbent glass mat (AGM) technology. It can be used as a battery replacement for many DC-UPS battery modules. 2. SHORT-FORM DATA Nominal voltage DC 12V Nominal battery 12Ah Capacity class capacity Nominal battery life 3 to 5 years According EUROBAT Battery current Max. 35A Discharging current Max. 3.5A Charging current Recommended charging voltage 13.9V 13.75V 13.6V 13.45V At 10 C At 20 C At 30 C At 40 C Self-discharge rate 3%/month At 20 C Temperature range -10 C to +40 C For charging -15 C to +50 C For discharging Connection terminal Faston 250 6.35x0.8mm Size (WxHxD) 151x100x98mm Weight 4200g / 9.26lb 3. ORDER NUMBERS Battery Replacement 4. MARKINGS 1/6

U-Series INDEX Page 1. General Description...1 2. Short-form Data...1 3. Order Numbers...1 4. Markings...1 5. Intended Use...3 6. Instructions for Disposal of the Batteries...3 7. Instructions for Battery Storage...3 Page 8. Installation Instructions... 3 9. Environment... 4 10. Fulfilled Standards... 4 11. Physical Dimensions and Weight... 5 12. Recommendations for a Long Battery Life... 6 The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com). No part of this document may be reproduced or utilized in any form without our prior permission in writing. WARNING Risk of electrical shock, fire, personal injury or death. - Do not short-circuit the battery poles or power wires and always check correct battery polarity. - Do not modify or repair the unit. 2/6

U-Series 5. INTENDED USE The battery is intended to be a replacement part for various DC-UPS battery modules. 6. INSTRUCTIONS FOR DISPOSAL OF THE BATTERIES Batteries must be completely discharged before replacement and can be returned to the supplier of the battery module or the battery manufacturer for disposal. Always dispose batteries through a recycling organization. 7. INSTRUCTIONS FOR BATTERY STORAGE Do not store batteries or battery modules at temperatures higher than 25 C or performance and lifetime may change. Do not store discharged batteries. Keep batteries fully charged! Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster then charged batteries. Do not store batteries longer than 9 months without charging or performance and lifetime may change. Every 9 months or whenever the open circuit voltage (OCV) falls below 12.6V, the battery module should be charged. Apply a charging voltage of 13.8V (at 25 C) for 72 hours. Batteries with an OCV below 12V must not be charged anymore and must be disposed. 8. INSTALLATION INSTRUCTIONS Install batteries in an enclosure providing protection against electrical, mechanical and fire hazards. Do not install the battery upside down. Do not cover or block the pressure release valves on top of the battery. Hydrogen gas can be released via pressure relief valves. It will form an explosive mixture in air when the concentration exceeds 4% in volume. It is mandatory to ensure sufficient ventilation of the battery. The necessary air flow must be calculated according to EN 50272-2. CAUTION: The unit contains wet cell batteries. Ventilation of the installation room in accordance with the rules of Canadian Electrical Code, part 1 is required if used in Canada. The maximum surrounding air temperature is +50 C / +122 F. The operational temperature is the same as the ambient or surrounding air temperature and is defined as the air temperature 2cm below the device. 3/6

U-Series 9. ENVIRONMENT Operational temperature *) -10 C to +40 C (14 F to 104 F) For charging Frequently charging below +5 C (41 F) reduced the lifetime of the battery -15 C to +50 C (5 F to 122 F) For discharging Storage temperature -20 C to +50 C (-4 F to 122 F) For storage and transportation Recommendation: Do not store at temperatures higher than 25 C or performance and lifetime may change. Humidity 5 to 95% r.h. IEC 60068-2-30 Do not energize while condensation is present Vibration sinusoidal Shock ±4mm at 16.7Hz fixed frequency for 1hour free fall from 20cm onto a wooden floor 0 to 6000m (0 to 20 000ft) Vibration in vertical mounting orientation according to IEC/EN 61056-1 Shock with bottom down orientation according to IEC/EN 61056-1 Altitude Degree of pollution 2 According to IEC 62477-1, not conductive *) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit. 10. FULFILLED STANDARDS UL 1989 VDS Component recognition - Stand-by batteries UL Category BAZR2 VdS Schadenverhütung () VdS Standard 2102 (Alarm Systems) RoHS Directive REACH Directive IEC 61056 IEC Batteries are exempt from the directive 2011/65/EU of the European Parliament and the Council of June 8 th, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Directive 1907/2006/EU of the European Parliament and the Council of June 1 st, 2007 regarding the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) General purpose lead-acid batteries (valve-regulated types) 4/6

U-Series 11. PHYSICAL DIMENSIONS AND WEIGHT Width 151mm / 5.94 Height 94mm / 3.70 Container height Height 100mm / 3.94 With battery poles Depth 98mm / 3.86 Weight 4200g / 9.26lb Fig. 11-1 Isometric view All dimensions in mm 5/6

U-Series 12. RECOMMENDATIONS FOR A LONG BATTERY LIFE Temperature: The temperature has the most impact on the service life. The hotter the temperature, the earlier the wear-out phase of the battery begins. The wear-out results in a degradation of battery capacity. Place the battery module in a cool location, e.g. near the bottom of the control cabinet. Do not place the battery module near heat generating devices. Do not overcharge batteries! Fig. 12-1 Service life (according to EUROBAT) vs. ambient temperature, typ. Service Life in Years 10 9 8 7 Design Life of Battery A: 3-5 Years C B: 6-9 Years C: 10-12 Years 6 B 5 4 A 3 2 1 Ambient Temperature 20 C 25 C 30 C 35 C 40 C 45 C Number of discharge cycles and depth of discharge: Do not discharge batteries more than necessary. Set buffer time limiter to the required buffer time. The number, as well as the depth of discharging cycles is limited. A replacement of the battery might be necessary earlier. When choosing the battery capacity, always try to get the next higher capacity than required. The depth of discharge reduces the service life of the battery and limits the number of cycles. Fig. 12-2 Battery degradation vs. discharging cycles, typ. Cell Capacity 120% 100% 80% 60% 40% 20% A B C Depth of discharge A: 100% B: 50% C: 30% Number of Discharging Cycles 0 200 400 600 800 1000 1200 Store batteries fully charged Do not store discharged batteries. Keep batteries fully charged! Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster then charged batteries. Batteries which are not in use should be recharged at least once a year. The higher the ambient temperature, the shorter the charging interval. At storage temperatures higher than 30 C, recharging should be done at least every nine months. 6/6