NT ELECTRONIC FLOWMETER, MODEL 4400

Similar documents
InVue Electronic Flowmeter, NT4400

NT Flowmeter, Model 4401

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

InVue Electronic Flowmeter, Model NT4400

Integrated Flow Controller, Model NT6500

RINSEGARD HP AND HPX. Simultaneously removes trace levels of positively charged ions and fine particles in ultrapure DI water

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

MODEL 106F TEFLON LIQUID FLOW SENSOR

CRITICAL MATERIALS HANDLING FLUOROGARD RS RESIST STRIPPING FILTERS

Ultra Compact UHP Liquid Flow Controllers

LFC Integrated Flow Control Module. Description.

Now available. in size. PrimeLocK Fittings. A premium PFA fitting for high-purity and corrosive chemical applications

INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520. User guide

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

LFC Integrated Flow Control Module. Description Malema Sensors

CRITICAL MATERIALS HANDLING PRIMELOCK FITTINGS

Overview CHEMLOCK PFA HOUSING. Space-saving housing solution enabling hassle-free cartridge changeouts and reduced exposure to chemicals

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

NOWPak Canister Dispense Connector

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Optimizer Point-of-use Photochemical Filters

Flaretek Tube Fitting Heated Flare and Assembly Procedures

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

Torrento high-flux, The new standard for nondewetting PTFE filters enabling unsurpassed particle protection and yield enhancement

CRITICAL MATERIALS HANDLING TORRENTO AT SERIES FILTERS

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

CRITICAL MATERIALS HANDLING PROCESSGARD PES CARTRIDGE AND DISPOSABLE FILTERS

FluoroLine Ultrapure PFA Tubing

Integra Pneumatically Operated Valves

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

Inline Ultrasonic Flowmeter

Flarelock II Tube Fitting

CR8 Manual Multi-turn Valve

NT INTEGRATED FLOW CONTROLLER, MODEL User Guide

Feature Advantage Benefit. Excellent chemical compatibility Better particle removal performance than polypropylene media

Integra Manually Operated Distribution Valves

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

Integra Pneumatically Operated Distribution Valves

Improve Yield & Reduce Cost with Levitronix Bearingless Pumps!

KEL DIFFERENTIAL PRESSURE FLOWMETERS

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Models 415 & 425. Electronic Pressure Regulators. Customer Value Proposition: Contact Information:

NOWPak Bottle System. Delivering your critical materials with purity, safety, and process efficiency FEATURES & BENEFITS. Purity.

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

PTFE PRESSURE REGULATOR

Mechanical Specifications:

Miniature Multimedia Valves

Glass Tube Full-View Flowmeters

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

WAFERGARD III NF-75O IN-LINE GAS FILTERS. Installation and use manual

Type Type 1001 Transducers. I/P & E/P Transducers

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

TELEDYNE HASTINGS INSTRUMENTS

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

UltiKleen G3 HiT KC Assemblies UltiKleen G2 HiT KC Assemblies

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Valve Solutions T2B. Features & Benefits. KF50 shown (KF40, KF50, NW63, NW80 and NW100 sizes available)

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

8000 Series Liquid Flow Meter

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

VSO Thermally Compensated Proportional Valve

Magnetic Inductive Flowmeter EP / UMF2 (B)

Sani-Tech Valves. Sani-Tech manufactures non-metallic sanitary valves for most high-purity fluid applications.

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

M-200 Series. High flow, Adjustable flow switch with right-angle flow

INSERTION flow sensor for continuous flow measurement

8000 Series Liquid Flow Meters

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Specification: Industrial Mixing Center

Figure 1: WPR2 Dimensions and Hardware

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Hoffer Engineering Guide for Liquids

SATRON VDt Differential Pressure Transmitter

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION

Transmitting Transducer. Gas/Air Velocity Range:

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Pneumatic Valves. Rometec srl Rometec srl Rometec srl -

RSS RAM SAMPLING SYSTEM

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

M-100 Series. Adjustable flow switch with right-angle flow

Signet 2551 Magmeter Flow Sensor

PSF50 Paddle flow switch

Field IT Electro-Magnetic Flowmeters Sensors

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

ELECTRONIC CONTROLLER

SATRON VT Pressure Transmitter

Miniature Solenoid Valves

Chemical Injection Pumps and Products

PPM100 Owner s Manual

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Transcription:

CONTAMINATION CONTROL SOLUTIONS NT ELECTRONIC FLOWMETER, MODEL 4400 Provides simultaneous flow and pressure outputs

simultaneous flow and pressure outputs Flow and Pressure Measurement Whether it s automation, process control or safety concerns that require flow and pressure measurement, the instrumentation must be clean, accurate and reliable. To meet the needs of the semiconductor industry, Entegris combines the latest electronic sensing technology and high purity materials to create leading-edge products that allow for greater control of process variables. No moving parts to generate particles Nonmetallic sensing technology for reliable measurement Integral pressure transducer for additional process information Flow-through design to minimize dead volume 1% full scale accuracy for critical measurements Easy installation in any orientation Constructed for Compatibility The NT Electronic Flowmeter is designed for use in ultra high purity applications in the semiconductor industry and is compatible with highly corrosive processes. The flow-through design minimizes dead volume, reducing the possibility of process contamination. This instru ment features PTFE and other high purity fluoro polymers for all wetted parts. With the FEP-jacketed pigtail available as the standard electrical connection, the flowmeter is resistant to harsh chemical environments and external spraydowns. Sensing Technology Using a nonmetallic pressure sensing technology, the instrument utilizes differential pressure to provide an accurate and reliable flow and pressure measurement. Flow and pressure measurements are not affected by bubbles or trapped vapor. All products are factory calibrated and 100% verified, require no field calibration and are simple to install. Standard electronic outputs enable easy integration with PLCs, control systems and electronic displays. Applications Measuring flow and line pressure allows the user to obtain valuable and critical diagnostic information which is used for monitoring or controlling process applications, such as: Chemical, DI water and slurry dispense Precision blending and metering Totalized flow for custody transfer System diagnostics 2 ENTEGRIS, INC.

Differential Pressure Measurement Entegris patented technology for differ ential pres sure flow measurement incorporates two pressure sensors. The pressure sensors are separ ated by a venturi style orifice in the process flow path. The orifice in the flow stream creates a differential pressure proportional to fluid flow rate. If there is no flow, the differential pressure is zero. As the flow rate increases, the differential pressure increases. Pressure Drop (psid) 8 7 6 5 4 3 2 1 Pressure Drop vs. Flow Rate (Approximate - values vary slightly by flow range) 10:1 turndown (T flow range) 0.45 0.30 0.15 Pressure Drop (bar) Flow Inlet pressure-outlet pressure The flowmeter electronics provide a linear flow signal (4-20 ma output signal) corresponding to the calibrated flow rate. The flowmeter also provides a pressure signal (4-20 ma output signal) corresponding to the pressure measured at the outlet sensor of the flowmeter. 0 0 20 40 60 80 100 % Full Scale Flow Rate (Standard Flowmeter Using Deionized Water) 0 Advantages of Differential Pressure Technology Ability to measure in many types of fluids Proven technology in many industries, including chemical, petroleum and natural gas Capable of measuring flow in the presence of trapped vapor and bubbles Provides repeatable measurements and reliable performance Reduces cost of ownership with easy installation and low maintenance Signal conditioning circuit FEP-jacketed pigtail connection Nonmetallic electronic pressure sensors Flared process connection Fluid flow Flared process connection Venturi style integral orifice ENTEGRIS, INC. 3

Dimensions FLARETEK CONNECTION Top View A 127.0 mm (5.00 ) 26 mm (1.02 ) Side View 53.3 mm (2.10 ) 26 mm (1.02 ) 40.1 mm (1.58 ) B 90.9 mm (3.58 ) 114.1 mm (4.49 ) Connector option: PVC-jacketed 8-wire cable Polypropylene 8-pin connector 101.6 mm (4.00 ) 8.4 mm (0.33 ) C Inlet/Outlet Dimension Port Connection A B C 1 4 Flaretek tube fitting 151.9 mm (5.98 ) 80.5 mm (3.17 ) 19.3 mm (0.76 ) 3 8 Flaretek tube fitting 155.4 mm (6.12 ) 81.8 mm (3.22 ) 19.3 mm (0.76 ) 1 2 Flaretek tube fitting 159.5 mm (6.28 ) 86.4 mm (3.40 ) 21.6 mm (0.85 ) 3 4 Flaretek tube fitting 165.6 mm (6.52 ) 94.7 mm (3.73 ) 27.4 mm (1.08 ) 1 Flaretek tube fitting 177.8 mm (7.00 ) 100.6 mm (3.96 ) 30.0 mm (1.18 ) SUPER 300 TYPE PILLAR CONNECTION Top View A 127.0 mm (5.00 ) 26 mm (1.02 ) Side View 53.3 mm (2.10 ) 26 mm (1.02 ) 40.1 mm (1.58 ) B 90.9 mm (3.58 ) 114.1 mm (4.49 ) 101.6 mm (4.00 ) C Inlet/Outlet Dimension Port Connection A B C 1 4 S300 Pillar tube fitting 123.7 mm (4.87 ) 80.5 mm (3.17 ) 19.3 mm (0.76 ) 3 8 S300 Pillar tube fitting 131.6 mm (5.18 ) 81.8 mm (3.22 ) 19.3 mm (0.76 ) 1 2 S300 Pillar tube fitting 136.7 mm (5.38 ) 86.4 mm (3.40 ) 21.6 mm (0.85 ) 3 4 S300 Pillar tube fitting 145.5 mm (5.73 ) 94.7 mm (3.73 ) 27.4 mm (1.08 ) 1 S300 Pillar tube fitting 155.7 mm (6.13 ) 100.6 mm (3.96 ) 30.0 mm (1.18 ) 4 ENTEGRIS, INC.

Specifications Materials: Wetted parts Body: PTFE Sensor interface: PFA or CTFE Primary seal: Kalrez Nonwetted parts Polypropylene, polyethylene, PVDF and PVC or FEPjacketed cable (in addition to materials listed above) Process temperature: 10 to 65 C (50 to 149 F) Consult factory for higher temperatures. Electrical input: 24 VDC (12 28 VDC input voltage) Electrical output: Two 4 20 ma electronically isolated outputs, one for flow and one for outlet pressure Pressure drop: 21 kpa (3 psid) at nominal flow, 10:1 turndown (nominal flow = 80% of full scale flow) Flow measurement 20 100% of range ±1.0% FS accuracy: 10 20% of range ±2.5% FS Accuracy stated as % of full scale using deionized water at 23 C (70 F) and includes the combined effects of linearity hysteresis and repeatability Repeatability: 20 100% of range ±0.5% FS 10 20% of range ±1.0% FS Operating pressure: 0 414 kpa (0 60 psig) Over-pressure limit: 690 kpa (100 psig) Pressure measurement ±1% of full scale (includes combined effects of linearity, hysteresis and repeatability) accuracy: Electrical enclosure: IP54 Approvals: Conforms to ANSI /ISA Standard 12.12.01, UL Standard 61010-1 Class I, Division 2, Groups A, B, C, D, T6 Note: Specifications are subject to change without notice. Please consult the factory for the most current information. ENTEGRIS, INC. 5

Flow Range The NT Electronic Flowmeter is available in the following fitting sizes and flow range combinations. T0 0-50 m T1 0-125 m T2 0-250 m T3 0-500 m T4 0-1250 m T5 0-2.5 m Flow Range T6 0-5 T7 0-10 T8 0-20 T9 0-40 T10 0-60 T11 0-90 Fitting Size 1 4 Yes Yes Yes Yes Yes 3 8 Yes Yes Yes Yes Yes Yes Yes 1 2 Yes Yes Yes Yes Yes Yes 3 4 Yes Yes Yes Yes 1 Yes Yes Yes Yes Yes Please consult the factory for custom fitting size and flow range combinations. T12 0-120 Ordering Information NT Electronic Flowmeter, Model 4400 Model Number 4400- - - - A - - Sensor Interface P1 = CTFE sensor interface P2 = PFA sensor interface P5 = CTFE sensor interface (hydrofluoric acid compatible) Electrical Output A = 4 20 ma (12 28 VDC input) Primary/Secondary Seal U1 = Kalrez 4079 Viton U2 = Kalrez 1050/Viton U3 = Kalrez 6375UP/Viton S1 = Kalrez 4079/Kalrez 4079 S2 = Kalrez 1050/Kalrez 1050 S3 = Kalrez 6375UP/Kalrez 6375UP Electrical Connector Type B06 = FEP-jacketed 6 pigtail electrical cable B12 = FEP-jacketed 12 pigtail electrical cable B30 = FEP-jacketed 30 pigtail electrical cable D00 = Polypropylene connector (cable not included) D06 = Polypropylene connector and 6 PVC cable D12 = Polypropylene connector and 12 PVC cable D30 = Polypropylene connector and 30 PVC cable Inlet/Outlet Connection* F02 = 1 4 Flaretek tube fitting F03 = 3 8 Flaretek tube fitting F04 = 1 2 Flaretek tube fitting F06 = 3 4 Flaretek tube fitting F08 = 1 Flaretek tube fitting W02 = 1 4 Super 300 Type Pillar tube fitting W03 = 3 8 Super 300 Type Pillar tube fitting W04 = 1 2 Super 300 Type Pillar tube fitting W06 = 3 4 Super 300 Type Pillar tube fitting W08 = 1 Super 300 Type Pillar tube fitting Flow Range* 10:1 Turn-down T0 = 0-50 m T1 = 0-125 m T2 = 0-250 m T3 = 0-500 m T4 = 0-1250 m T5 = 0-2.5 T6 = 0-5 T7 = 0-10 T8 = 0-20 T9 = 0-40 T10 = 0-60 T11 = 0-90 T12 = 0-120 * Please refer to previous page for fitting size and flow range combinations available. Product specified with a flared connection is packaged with two PVDF nuts. For alternative nut material or custom configurations and specifications, please contact the factory. 6 ENTEGRIS, INC.

For More Information Please call your Regional Customer Service Center today to learn what Entegris can do for you. Visit www.entegris.com and select the Customer Service link for the center nearest you. Terms and Conditions of Sale All purchases are subject to Entegris Terms and Conditions of Sale. To view and print this information, visit www.entegris.com and select the Legal Notices link from the footer. Entegris, the Entegris Rings Design, Creating a Material Advantage, NT and Flaretek are registered trademarks of Entegris, Inc. Kalrez is a trademark of E.I. DuPont de Nemours and Company. Viton is a registered trademark of DuPont Dow Elastomers. ANSI is a registered trademark of American National Standards Institute. ISA is a registered trademark of International Society of Automation. U.S. Patent 5,672,832, other patents pending. ENTEGRIS, INC. Corporate Headquarters 129 Concord Road Billerica, MA 01821 USA Customer Service Tel. +1 952 556 4181 Customer Service Fax +1 952 556 8022 In North America 800 394 4083 www.entegris.com 2004 2014 Entegris, Inc. All rights reserved Printed in USA 3962-1592ENT-0614