HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW)

Similar documents
industry revolves around

Rotary vane air compressors for industry. Industry s advantage. with Hydrovane.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Industry s advantage. with Hydrovane. aircarecompressors.co.uk. Rotary vane air compressors for industry

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

COMPRESSED AIR SINCE 1919 BLADE BRINGING YOU THE FUTURE TODAY BLADE 4 5 7

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

A E R Z E N S C R E W C O M P R E S S O R S

Standard Products 2015 Edition

Rotary vane air compressors for industry. Standard Products

EnviroAire T/TVS Series

L23RS L29RS (30 40 HP) VARIABLE SPEED ROTARY SCREW COMPRESSORS. LRS Series

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Get your last air compressor first.

UD SERIES COMPRESSORS

ENVIROAIRE T & TVS HP OIL-FREE TWO-STAGE FIXED & VARIABLE SPEED ROTARY SCREW COMPRESSOR. EnviroAire T/TVS

Rotary Tooth Air Compressor System

Check out your benefits: Screw compressors S series

L23 L29 (30 40 HP) FIXED SPEED ROTARY SCREW COMPRESSORS. L Series

15-37 kw Rotary Screw Compressors

ULTIMA U75 U HP OIL-FREE TWO-STAGE VARIABLE SPEED ROTARY SCREW COMPRESSOR. Ultima

L04 L290 (5 400 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series

SCR Variable Speed Series Rotary Screw Compressor

Rotary Tooth Air Compressor System

SCK. Air Compressors SCK

L Series. L04 L05 (5 7.5 HP) Fixed Speed Rotary Screw Compressors

COMPRESSED AIR SINCE 1919 BLADE BRINGING YOU THE FUTURE TODAY BLADE

DSP SERIES. Oil Free Rotary Screw Air Compressors hp kw

ENVIROAIRE T & TVS HP OIL-FREE TWO-STAGE FIXED & VARIABLE SPEED ROTARY SCREW COMPRESSOR. EnviroAire T/TVS

Essentials encapsulated kw

SIERRA. Oil Free Rotary HP (37-300kW) OIL-FREE ROTARY SCREW AIR COMPRESSOR HP ( kw) Point of Manufacture - Davidson, NC USA

Operating Principle. Rotary Vane Compressor

BLADE BLADE COMPRESSED AIR SINCE 1919 BRINGING YOU THE FUTURE TODAY

ROGERS MACHINERY COMPANY, INC

Rotary Screw Compressors. L26RS Variable Speed

Sullair: An Industry Leader

A I R C O M P R E S S O R S R O L L A I R E

Atlas Copco Oil-injected Rotary Screw Compressors. G kw / hp

ROGERS MACHINERY COMPANY, INC

ABOUT MATTEI CUSTOM BUILT MATTEI COMPRESSOR PACKAGES

We re a dedicated team of compressed air specialists, passionate about good design, energy efficiency and reliability.

Nirvana hp Variable Speed Drive Rotary Screw Compressors. The Next Generation of Compressed Air

Lubricated Rotary Screw Air Compressors

Essentials encapsulated 3-20 HP

V-Series. Oil-less Rotary Vane

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

Sullair: An Industry Leader

Choose quality. FIMA 1

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

VSD SERIES // Variable Speed Drive Compressors The energy efficient champion

KTA50 Land Based Drilling Power Modules

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Rotary screw compressors

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series

Model name XATS 138 XAHS 108 Normal effective Working Pressure Bar(g) 7 8, Psi (g)

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Doosan XHP1070WCAT Bid Specifications

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SCREW COMPRESSORS OIL-FREE

MOBILAIR M 135/M 170/M 171. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 10.5 to 17.0 m³/min ( cfm) COMPRESSORS

OIL-INJECTED MEDICAL AIR COMPRESSORS GA 5-11 MED / GA MED / GA 7-37 VSD+ MED

ESP Series Screw Compressors

Reciprocating Compressors AIRBOX / AIRBOX CENTER

single stage rotary vane pumps KINNEY

XAS185 KD T4F Product Reference. Product Reference XAT(V)S 186 Jd Stage IV. Portable compressor. Standard Scope of Supply.

5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS. Paradigm

SULLAIR Oil Free Rotary Screw Air Compressors

Oil-Injected Variable Speed Rotary Screw Air Compressors HSC FRECON

Rotary Vane Compressors DRT4.04 DRT4.08

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

MSB kw

L45SR - L75SR - L120SR

P a c k a g e s. One step ahead. Energy-efficient Reliable Compact Quiet

Atlas Copco. Oil-free positive displacement screw blowers ZS / ZS VSD kw / hp

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

MSC kw

2 30 HP RECIPROCATING AIR COMPRESSORS. R-Series

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

THE EXPERTISE YOU WANT, THE SUPPORT YOU NEED, THE VALUE YOU DEMAND

FAC Series PORTABLE COMPRESSORS

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Atlas Copco Industrial Aluminium Piston Compressors. LE/LT/LF Oil-lubricated & oil-free ( kw / 2-20 hp)

VT Oil-Free Range Operators Handbook

EG Series Screw Air Compressors

Nirvana Variable Speed Drive Rotary Screw Compressors kw

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

GS Series. Rotary screw compressors. Variable Speed Drive HP

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

OPERATOR S MANUAL AND PARTS LIST

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

DESCRIPTION AND OPERATION

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

Doosan XHP1170WCAT Bid Specifications

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Doosan XHP1170FCAT Bid Specifications

SAV ( HP) FIXED SPEED ROTARY SCREW COMPRESSORS. Electra Saver

COMPRESSED AIR SINCE 1919 BLADE BLADE

Transcription:

HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW) Performance and Technical Data. Please refer to the final 2 pages of this document. Hydrovane are pleased to announce a range of Rotary Vane compressors in Regulated Speed format from 7kW up to 75kW. RS Models are now available in:- 7kW, 11kW, 15kW, 22kW, 30kW, 37kW and 45kW in the Vertical Format. with 75kW as an Enclosed Horizontal model. Background Compressors are most efficient when operating at full load. Part load and off-load conditions expend more energy at a reduced air flow. This fact can surprise many compressed air users after investigation of a poorly matched control system which is consuming energy and costing the user money that their process does not require. An effective way of closely matching an air flow to a compressed air system demand is by the use of a Variable Speed Drive (VSD), also known as an Inverter Drive. These electrical devices are excellent tools for optimising the electrical energy cost used to drive air compressors. A Hydrovane Regulated Speed compressor allows the flexibility of the Motor to work within a broader speed range than a fixed speed compressor. This option can satisfy a compressor system demand more precisely than a fixed speed unit can manage. A figure of +/- 0.2 of a bar based on selectable target pressure is achievable with a Hydrovane RS compressor. If the Compressed Air system has been analysed and found to be suitable to support an RS compressor then it is an excellent tool for optimising the electrical energy costs required to power an essential piece of plant equipment. Hydrovane have 10 years of extensive experience with Inverter Drives used in compressor technology which has resulted in the confidence and ability to incorporate the technology throughout our product range. Vertical HV04-HV45 Quote Support Documentation 1 of 7

The Package The Hydrovane Regulated Speed compressor (RS) has the same physical appearance as a Fixed Speed model. The same components are used:- Base Frame and enclosure, Drive Motor, Air End, Air and Oil Cooler, etc. The addition of a Variable Speed Inverter Drive and a modified starter panel means that the Motor speed can be controlled. The Inverter controls the speed of the motor allowing it to run down as low as 880rpm, and anything up to 2100rpm, (dependent upon the model). This in-turn varies the compressor air flow output. Features and Benefits The starter panel runs the full length of all vertical compressors. This allows plenty of room for any remote monitoring equipment, if required, or for RS compressors, a space for the Inverter Drive. This varying output from the compressor allows the compressor to be run at a slower speed to improve flow and efficiency. Compressors from 7kW up to and including the 45kW RS, all have a 10 bar Air End. This means that the flow can be regulated between the minimum pressure at 6 bar, up to the maximum pressure of 11 bar. This optimises the efficiency and flow of your compressor system to save energy. The 75kW RS operates between the minimum 6 bar and the maximum of 9 bar as this model has an 8 bar Air End. Control and Instrumentation The 'target pressure' the compressor maintains is selected and entered into the Electronic Controller display as standard on all RS Speed compressors. 37kW RS Starter Panel The compressor then strives to work to a pressure differential of +/- 0.2 bar from the target pressure. A pressure transducer is monitoring the requirements from the compressor system and feeding this information back to the controller. The controller then sends a signal to the inverter to regulate the motor speed accordingly. Fixed speed compressors work at 50Hz. Regulated Speed models frequency can be controlled so they work between around 30Hz to 70Hz. This is how they we are able to regulate the speed of the motor and regulate the flow of air from the compressor on a wider range. The controller is standard on all RS compressors, the only difference being the software parameters programmed into the controller. The parameters are controlled by security codes to protect the integrity of the compressor after commissioning. Electronic Control Panel Vertical HV04-HV45 Quote Support Documentation 2 of 7

Reduced Energy Venting System (REVS) Compressors are most efficient at full load. Part load conditions expend needless energy at a reduced air flow. In order to combat part load conditions and to further save energy losses and increased utility bills, the unique REVS system vents internal Air End pressure to atmosphere when the system is full or the system does not require any Air. This reduces the motor speed and in-turn saves valuable electricity. Features and Benefits Compressor Regulation REVS matches compressor output to the system demand and eliminates unnecessary unloaded running to save on electrical costs. An Air Vent Solenoid valve energises and quickly vents Air pressure which is not required in a part-load state. The Air Intake valve is also closed for a split second so the compressor starts with no internal air pressure giving a softer start. During periods of low or zero demand the compressor automatically stops in order to reduce energy consumption and can immediately restart when demand increases. Pressure is accurately monitored by a pressure transducer linked to the control system which enables plant discharge pressure to be controlled within +/- 0.2 bar. During periods of low or zero demand the compressor automatically stops in order to reduce energy consumption and will restart when demand increases. Cooling and Ventilation The 'combi-cooler' on the HV07RS-HV22RS located in the rear panel of the compressor has two functions. The first function cools the oil before the oil filter element and returns it to the Stator Oil injectors (which is the largest portion of the cooler). The smaller second section acts as an aftercooler for the compressed air delivering air temperature to the system at less than 10 C above ambient. AIR OIL Oil circulates through the compressor for cooling, lubricating and sealing, passing through the oil cooler and spin on type filter before being injected into the compression chamber. A thermostatically controlled oil bypass valve is fitted to ensure that the compressor reaches normal operating temperature as soon as possible after start-up. The cooling fan automatically stops when the compressor system temperature decreases sufficiently. This further reduces off load power consumption. Air flow through the compressor is designed to give specific cooling through the starter panel. Cooling Compressed air outlet temperature ranges from 7 C up to 10 C above ambient temperature. This results in smaller compressed air purification systems being required. Vertical HV04-HV45 Quote Support Documentation 3 of 7

Reduced Maintenance Features and Benefits The Vertical compressor is designed to minimise the number of consumable parts and provide extended service intervals. Easy access to service components as the hinged door and removable top lid cover offers access to all consumable items. 'Spin on-spin off' Oil and Air Filter and direct access to the Oil fill and drain access points means servicing is no longer a messy, arduous process. Silenced Package Modular package design is mounted on a steel base frame and contained within an acoustically insulated epoxy coated steel enclosure. The noise levels and reduced footprint of the Vertical range increase the versatility of the installation options. Total Piece of Mind Hydrovanes unique ADVANCE Warranty scheme is completely free, simple, flexible, and offers up to 10 years or up to 48,000 running hours of cover. (from the date of registration into the scheme). It is simple to use with minimum administration. Your local Hydrovane distributor will be able to register the compressor when the time comes for installation and commissioning. All RS models are eligible for the ADVANCE warranty scheme with the Inverter Drive having a 5 year warranty. The validity of the ADVANCE scheme rests on the user agreeing to the servicing and maintenance being carried out by an authorised Hydrovane distributor using proprietary service kits, oil and spare parts. A small price to pay for the peace of mind the ADVANCE warranty scheme offers. (If the ADVANCE warranty is not taken then a standard 12 month warranty applies) Every compressor arrives on-site with an ADVANCE warranty logbook. Just like a car, the service record can be completed every time work is done on the compressor. The log-book then acts as a service history for the compressor. Vertical HV04-HV45 Quote Support Documentation 4 of 7

The Rotary Vane Principle A B C D E F G H Air is drawn in through the air intake valve. Air is contained between the rotor and the stator wall as the cast iron blade is free to slide out of the slot in the rotor. This creates a compression cell. Air is compressed by decreasing volume as the off-set stator enables the blade to return into its slot. Oil is continually injected to cool, seal & lubricate. High pressure air passes into the primary oil separator where some 98% of the oil is removed without the need for an oil pump. Remaining traces of oil are removed in a final separator element, providing high quality air. System air passes through the aftercooler, removing most of the condensate. Oil is circulated by internal air pressure. It passes through an air-blast oil cooler and filter before being returned into the compressor. Air flow is regulated by an in-built modulation system Vertical HV04-HV45 Quote Support Documentation 5 of 7

Technical Data HV07RS - HV22RS PERFORMANCE DATA HV07RS HV11RS HV15RS HV18RS HV22RS F.A.D. m³/min. (cfm) @ 6-10 bar 0-1.30 (46) 0-1.87 (66) 0-2.46 (87) 0-3.12 (110) 0-3.88 (137) Noise Level - db(a) 67 69 70 70 71 Power - kw (hp) 7.5 (10) 11 (15) 15 (20) 18 (25) 22 (30) Starter type Inverter Soft Start Drive Type Direct Drive Operating Controls Inverter Drive Variable Speed Reduced Energy Venting System (REVS) Motor Rotation Speed - rpm up to 2220 up to 1900 up to 1800 Ambient Temperature Range 0 to 40 C Maximum Relative Humidity 85% non-condensing Air Discharge Temp. (above ambient) < 10 C FACTORY SETTINGS Minimum Pressure Valve - bar 5.5 to 6.0 Minimum Air Line Pressure - bar (PL) 6.5 8.0 Maximum Air Line Pressure - bar (PU) 8.0 8.5 REVS Delay Period - seconds (Rt) 60 Run-on-Time to Stop - seconds (St) 10 Pressure Display Units (PD) 0 (bar) (1 = psi, 2 = kpa) Temperature Display Units (Td) 0 = C (1 = F) Servo Valve - bar 8.5 9.0 Vacuum Relief Valve 1/2 anti-clockwise One turn anti-clockwise INSTALLATION Air Outlet Size - Rp ¾ ¾ ¾ 1 1 Minimum Room Volume - m³ 15 25 25 35 35 Air Inlet/Outlet Area - m² 0.3 0.5 Ventilation Rate - m³/h 2000 3400 Cooling Air Flow - m³/h (cfm) 1850 (1089) 3100 (1825) 4500 (2649) Recommended Air Receiver Capacity - litres 272 DIMENSIONS & CAPACITIES Compressor Oil Capacity - litres 3.0 7.0 7.0 7.5 7.5 Approved Compressor Oil Fluid Force Red 2000, Food Grade and HPO Air Quality - mg/m³ < 5 Package Depth - mm 635 825 Package Width - mm 500 700 Package Height - mm 1050 1510 Package Weight - kg 204 393 406 507 520 Vertical HV04-HV45 Quote Support Documentation 6 of 7

Technical Data HV30RS - HV75RS PERFORMANCE DATA HV30RS HV37RS HV45RS HV75RS F.A.D. m³/min. (cfm) @ 6-10 bar 0-5.58 (197) 0-6.46 (228) 0-7.93 (280) - F.A.D. m³/min. (cfm) @ 6-8 bar - - - 0-13.42 (474) Noise Level - db(a) 73 73 73 73 Power - kw (hp) 30 (40) 37 (50) 45 (60) 75 (100) Starter type Inverter Soft Start Drive Type Direct Drive Operating Controls Inverter Drive Variable Speed Reduced Energy Venting System (REVS) Motor Rotation Speed - rpm up to 1700 up to 1870 Ambient Temperature Range 0 to 40 C Maximum Relative Humidity 85% non-condensing Air Discharge Temp. (above ambient) < 10 C FACTORY SETTINGS Minimum Pressure Valve - bar 5.5 to 6.0 Minimum Air Line Pressure - bar (PL) 8.0 6.5 Maximum Air Line Pressure - bar (PU) 8.5 8.0 REVS Delay Period - seconds (Rt) 60 Run-on-Time to Stop - seconds (St) 2 10 Pressure Display Units (PD) 0 (bar) (1 = psi, 2 = kpa) Temperature Display Units (Td) 0 = C (1 = F) Servo Valve - bar 9.0 8.5 Vacuum Relief Valve 1½ turns anti-clockwise Non-adjustable INSTALLATION Air Outlet Size - Rp 1.5 Minimum Room Volume - m³ 60 90 90 120 Air Inlet/Outlet Area - m² 0.6 1.0 1.0 2.0 Ventilation Rate - m³/h 8,300 10,200 11,000 24,000 Cooling Air Flow - m³/h (cfm) 5020 (2955) 6320 (3720) 6550 (3855) 10,300 (6062) Recommended Air Receiver Capacity - litres 500 900 900 1200 DIMENSIONS & CAPACITIES Compressor Oil Capacity - litres 21.0 45.0 Approved Compressor Oil Fluid Force Red 2000, Food Grade and HPO Air Quality - mg/m³ < 3 < 5 Package Depth - mm 1100 955 Package Width - mm 900 2330 Package Height - mm 1592 1600 Package Weight - kg 909 963 992 1560 Vertical HV04-HV45 Quote Support Documentation 7 of 7