Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Similar documents
ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

Hazardous Factory Sealed Control Devices

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS / EFS Series Control Stations

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Arktite Plugs, Receptacles, and Connectors

Plugs and Receptacles: Hazardous Location

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs & Receptacles. Section P

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Spring-loaded cover seats against neoprene gasket.

EDS / EFS Series Control Stations

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Plugs and Receptacles Industrial Heavy Duty Non-Hazardous

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

EPOXY POWDER COATED COPPER FREE ALUMINUM

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

EDS / EFS Series Control Stations

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

IEC 309 Plugs, Connectors, Receptacles, and Inlets

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Control Stations Hazardous and Non-Hazardous

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Hazardous Duty Applications

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Covers for Cast Iron or Aluminum Device Boxes

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Circuit Breakers Hazardous

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Condulet Cast Device Boxes and Covers Application and Selection

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Motor Starters Hazardous and Non-Hazardous

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Solar Combiner Solutions

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

L-1. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit.

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Plugs & Receptacles. PowerMate. drilling pin and sleeve connectors

Condulet Conduit Bodies and Outlet Boxes Hazardous

PowerMate Drilling Pin and Sleeve Connectors

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

VR A 3W 4P Receptacle. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

GHG43 Series Control Stations

Applications. Illustrated Features

Applications. Standard Materials

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Division 2 Contender Series Factory Sealed Control Stations

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Transcription:

Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment in locations which are hazardous due to the presence of flammable vapors or gases in damp or corrosive locations in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist Features: The delayed action feature permits the plug to be used as an emergency push-pull switch CPS receptacles are equipped with a rotating mechanism which prevents complete withdrawal of the CPP plug in one continuous movement. Details of operation are illustrated and explained below Fig. Fig. 2 Fig. 3 Figure shows a CPS angle type receptacle assembly with CPP plug fully engaged. Figure 2 shows the plug withdrawn until it is stopped by the delayed action mechanism. In this position the circuit has been broken and the arc has been snuffed in the contact chambers. To completely withdraw the plug as shown in Figure 3, the delayed action release lever mush be rotated counterclockwise. The time required to actuate the mechanism permits dissipation of the arc-generated heat before contacts and arcing chambers are opened to the atmosphere. When inserting the plug, the reverse procedure is followed. CPS receptacles are factory sealed to simplify installation and wiring external seals are not required Series 52 receptacles have top hinged cover design, with 45 downward angled receptacle housing, to provide superior environmental protection from accumulations of dust, snow, ice, and water Back boxes used for angle type receptacles are standard EDS bodies. Assemblies are listed with single and two gang bodies and dead end or through feed hubs 2 to sizes Back boxes used for straight type receptacles are available with a variety of hub arrangements in 2 and 3 4 sizes All receptacles and 30 ampere plugs are provided with pressure terminals for ease of field wiring. 20 ampere plugs have solder terminals. Grounding: NEC Article 50 and CEC Part Section 8 requires that metal frames or exposed noncurrent-carrying metal parts of portable devices used in hazardous locations be grounded through an extra conductor in the portable cord CPS receptacles and CPP plugs are provided with an extra grounding pole In plugs, provision is made for attachment of the grounding wire to the grounding pole. In addition, direct connection is provided between plug and receptacle housings and the grounding pole. In the receptacle, grounding is accomplished through the conduit system Interchangeability of Plugs with Non-Hazardous Location Receptacles: 30 ampere CPP plugs can also be used with standard 30 ampere AR Arktite receptacles of the same style and number of poles, thus permitting portable devices suitable for use in hazardous locations to be connected to receptacles in both hazardous and non-hazardous areas NOTE: Equipment to be used in hazardous areas must be suitable for use in the specific hazardous location. Standard Materials: Receptacle housings die cast copper-free aluminum EDS Back boxes Feraloy iron alloy (U.S.)/Copper-free aluminum (Canada) Other back boxes Feraloy iron alloy Plug exteriors copper-free aluminum or Krydon fiberglass-reinforced polyester material. See listings Insulation all receptacles and plugs Krydon fiberglass-reinforced polyester material Pressure or solder contacts brass Crimp/solder contacts leaded red brass Standard Finishes: Copper-free aluminum aluminum acrylic paint. Feraloy electrogalvanized and aluminum lacquer Fiberglass-reinforced polyester natural (red, white) Brass natural Leaded red brass electro-tin-plate Electrical Rating Ranges: Angle type 20 and 30 amperes; 25 and 250 VAC Straight type 20 amperes; 25 and 250 VAC Certifications and Compliances: NEC/CEC: Class I, Division and 2, Groups C,D UL Standard: 00 CSA Standard C22.2 No. 30 002 US: -866-764-5454 CAN: -800-265-0502 Copyright 2006 Cooper Crouse-Hinds

Arktite Circuit Breaking CPS 2P Options: Material: copper-free aluminum, natural finish, is available on certain back boxes. See listings. Add suffix SA to Cat. No. * The following special options are available from factory by adding suffix to Cat. No. Suffix to be Added to Description Cat. # Receptacle interior rotated 22 2 degrees to right (viewed from face) and plug changed to match. 30 ampere units only...s4 Combination of receptacles and EFS/EFD or EDS series devices, such as pilot lights, switches, push button stations, etc., can be furnished using three, four and five gang bodies...specify Hub arrangements other than those listed can be supplied...specify Dimensions Straight type receptacles Series 52 20 Ampere plugs Cat. # a b C d CPP56 8 3 8 6 7 8 3 4 9 6 CPP52 7 5 2 3 4 9 6 These dimensions are approximate and vary with cable size. Series 532 and 732 Angle type receptacles a = 3 2 for single gang 7 3 6 for two gang 30 Ampere plugs US: -866-764-5454 CAN: -800-265-0502 Copyright 2006 Cooper Crouse-Hinds 003

Arktite Circuit Breaking CPS CPS52R Receptacle unit only CPS52 Single gang angle type CPS52 Two gang angle type CPP plugs with mechanical cable grip and Neoprene bushing Style 2 Grounded through extra pole and shell Plug With Plug High Impact Single Gang Two Gang With Molded Receptacle Receptacle Aluminum Composition Receptacle Hub Assembly Assembly Cable Handles Handle Unit only Rating Description Size Cat. # Cat. # Dia. Cat. # Cat. # Cat. # 20A, HP, 20A, 8VDC 30A, 2 HP, 7A, 2 HP, 480VAC, 60 hertz 30A, 3 HP, 7A, HP, 480VAC, 60 hertz 2 CPS52-0* CPS52-02* Dead 3 4 CPS52-20* CPS52-202* CPS52-30* CPS52-302*.32 to.625 2 CPS52-* CPS52-2* Through 3 4 CPS52-2* CPS52-22* CPS52-3* CPS52-32* CPP56 CPP52 CPS52R 2 CPS532-0 CPS532-02 Dead 3 4 CPS532-20 CPS532-202 CPS532-30 CPS532-302.375 to.875 2 CPS532- CPS532-2 Through 3 4 CPS532-2 CPS532-22 CPS532-3 CPS532-32 CPP4553 CPS532R 2 CPS732-0 CPS732-02 Dead 3 4 CPS732-20 CPS732-202 CPS732-30 CPS732-302 3-wire,.375 to.875 4-pole 2 CPS732- CPS732-2 Through 3 4 CPS732-2 CPS732-22 CPS732-3 CPS732-32 CPP4752 CPS732R * Back boxes are available in copper-free aluminum. To order, add suffix SA to the Cat. No. CSA certified units are rated at 600 VAC at 7A. Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings. 20 amp plugs are furnished with solder terminations at standard, ground contacts have pressure terminations. 004 US: -866-764-5454 CAN: -800-265-0502 Copyright 2006 Cooper Crouse-Hinds

Arktite Circuit Breaking CPS 2P CPS straight type shown with plug Style 2 Grounded through extra pole and shell 20A, HP, 60-400 hertz, 20A, 8VDC With aluminum handle CPS Dead Hub Assembly Body Size Cat. # Cat. # 2 CPS4-20 CPS20 3 4 CPS4-20 CPS20 CPS Receptacle Unit With Spring Door Cat. # CPS4R With high impact molded composition handle CPP Plugs With Mechanical Cable Grip and Neoprene Bushing Aluminum Composition Cable Dia. Cat. # Cat. #.32 to.625 CPP56 CPP52 CPS Through Hub Assembly Body Size Cat. # Cat. # 2 CPS4-2 CPS2 3 4 CPS4-2 CPS2 US: -866-764-5454 CAN: -800-265-0502 Copyright 2006 Cooper Crouse-Hinds 005

Arktite CPR Cable Connector Receptacles Circuit Breaking Application: CPR Arktite delayed action cable connector receptacles are used in non-hazardous areas only*: to make up adapter sets for connecting portable devices having CPP plugs to receptacles in non-hazardous areas. This is accomplished by equipping one end of the length of cable with the CPR receptacle and the other with a plug to mate with the receptacle in the non-hazardous area. to make up extension cords using the CPR receptacle at one end and a CPP plug at the other Features: Spring door housing with the same delayed action rotating mechanism provided in CPS receptacles listed on pages 002 through 005 Pressure terminals are furnished for ease of wiring Gland nut with mechanical cable grip and bushing for effective strain relief Standard Materials: Housing copper-free aluminum Insulation fiberglass-reinforced polyester Contacts brass Standard Finishes: Copper-free aluminum natural Fiberglass-reinforced polyester natural (red) Brass natural Style 2 Grounded through extra pole and shell. For use with CPP56 and CPP52 series plugs listed on page 005. Description Rating Cable Dia. Cat. # 20A, HP, 60 hertz.375 to.625 CPR54 20A, 8 VDC * CSA certified unit suitable for Class I Groups C and D (not available in USA). 006 US: -866-764-5454 CAN: -800-265-0502 Copyright 2006 Cooper Crouse-Hinds