Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

Similar documents
S&C Switch Operators Types AS-1A and AS-10

INSTRUCTIONS. 1 Schematic. I Device ' I. S8C Switch Operators - Type CS-24. For Operation

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

INSTRUCTIONS. S&C Switch Operators - Type CS-1 A. For Operation INTRODUCTION

INSTRUCTIONS For Installation

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

INSTRUCTIONS For Installation

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

The Standard Mounting Arrangements for S&C Alduti-Rupter Switches

INSTRUCTIONS. Operating Lever4 Maximum Operating

Introduction CAUTION. S&C Power Operated Metal-Enclosed Switchgear Outdoor Distribution (4.16 kv, through 34.5 kv)

Horizontal Circuit Switchers

Horizontal Circuit Switchers

SPECIFICATION BULLETIN

Three-Phase Pole Mounted Recloser

I TABLE OF CONTENTS I INTRODUCTION. S&C Switch Operators - Type AS-1A. Qualified Persons. For Installation

INSTRUCTIONS For Field Assembly and Installation

S&C Trans-Rupter II Transformer Protector Outdoor Transmission (69 kv through 138 kv)

Introduction CAUTION CAUTION. S&C Power Operated Metal-Enclosed Switchgear Indoor and Outdoor Distribution (4.16 through 34.5 kv)

The Standard Mounting Arrangements for S&C Omni-Rupter Switches

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Instructions for Installation and Operation

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv)

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

S&C Vista Underground Distribution Switchgear

Installation. S&C Circuit-Switchers Mark VI 69-kV 51-inch Phase Spacing Single Pedestal Design Outdoor Transmission.

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Instructions for Installation and Operation

C1000 Series Automatic Cap Bank

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

OVERHEAD SERVICE. Items to consider

Typical Specification

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Publication No.: PSG

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

S&C Manual PME Pad-Mounted Gear

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Transfer switch GTEC open or delayed transition

SECTION MOTOR CONTROL

Cleaning Flooded Gear

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

Installation and Operation

Underground Distribution Switchgear

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

E Series Electric Actuators

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Underground Distribution Switchgear

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

East Central College

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Installation. S&C Manual PME Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) Table of Contents

Florham Park, NJ USA Call (ASCO) for sales or service

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

EUNHA MACHINERY INDUSTRIAL CO., LTD.(EMICO)

Operation. S&C Source-Transfer Vista Underground Distribution Switchgear. Pad-Mounted, Dry-Vault-Mounted, Wet-Vault-Mounted, and UnderCover Styles

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

GE CONSUMER & INDUSTRIAL

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Transfer switch OTEC open or delayed transition

Hazardous Factory Sealed Control Devices

Cleaning Flooded Gear

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

University of Houston Master Construction Specifications Insert Project Name

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

S&S POWER SWITCHGEAR EQUIPMENT LTD.,

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Type SOQ Negative Sequence Time Overcurrent Relay

Environment-Sealed Basic Switches

Motor-drive mechanism, type BUL. Technical guide

Florham Park, NJ USA Call (ASCO) for sales or service

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

PATTERSON PUMP COMPANY

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

MC-351, 421, 431, MC-4311

Design Standard. Purpose: Design Standard:

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Interrupter Replacement INSTRUCTIONS. For Replacement of Interrupters. A Cypo.qdated is the S&C trademark for devices employing the S&C Cypoxfl

Multi-Pak Group Control

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

Transcription:

a Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Switch Operators Types AS-1A and AS-10 are high-speed operators especially designed for remote power operation of S&C Alduti-Rupter Switches. Types AS-1A and AS-10 Switch Operators include the following features: Built-in internal decoupling mechanism, operable by integral external selector handle, with padlocking provisions and automatic mechanical locking of output shaft. Laminated safety-plate window permits visible air-gap verification of complete disengagement of output shaft. Open-close pushbuttons, externally operable, with padlockable cover. Built-in nonremovable, foldaway manual operating handle. Mechanical position indicators for both switch operator and Alduti-Rupter Switch open and closed posi tions (except for S&C Switch Operators Type AS-10). Non-reset electric operation counter. Laminated safety-plate window for inspection of builtin internal decoupling mechanism, mechanical position indicators, and operation counter (and position-indicating lamps, if furnished as accessories). Foolproof recoupling. Impossible with position-indexing drums to couple the switch operator and the Alduti-Rupter Switch unsynchronized. Fingertip precision adjustment of output-shaft rotation using self-locking spring-biased cams (except for S&C Switch Operators Type AS-10, which are factory-adjusted). Eight-pole auxiliary switch, coupled to motor, with fin gertip precision adjustment of individual contacts using self-locking spring-biased cams. Antifriction bearings throughout; tapered roller bearings for all high-torque gear-train shafts. Two-pole pull-out fuseholders for space heater and (except for 12-volt dc models) motor circuit. (For 12-volt dc models, a two-pole disconnect switch is used in series with a motor-circuit fuse.) Weatherproof, dustproof enclosure, equipped with 120/240-volt ac space heater, factory-connected for 240-volt ac operation. Can readily be field reconnected for 120-volt ac operation. Tamper-resistant design welded enclosure; baffled louvers; gasketed, flanged door openings; cam-action door latch; provisions for padlocking. Foul-weather accessibility to interior of enclosure. Access is by door rather than by removal of entire enclosure. S&C Switch Operators, Catalog Numbers 38854R4, 38855R4, and 38856R4 include 12-volt dc battery and constant-burden battery charger for connection to an S&C 30-Volt-Ampere Potential Device or other 120-volt, 60-hertz source. EXCLUSIONS: Switch operators do not include the operating linkage between the switch operator and the highvoltage switch. a S&C Switch Operators Types AS-1A and AS-10 are manufactured in accordance with a quality system certified to ISO 9001. Supersedes Specification Bulletin 769-31 dated 1-31-11 and Parts Bulletin 769-1 dated 11-21-11 April 16, 2012 S&C Electric Company Specification Bulletin 769-31

Conditions of Sale Continued SPECIFICATION DEVIATIONS: Various accessories are available as listed in the table on page 4. S&C Switch Operators Types AS-1A and AS-10 utiliz ing 115-volt 60-hertz or 230-volt 60-hertz motor and con trol voltage are available with optional source-transfer control compatibility as indicated in the applicable table on page 4. This accessory permits use of the switch opera tor along with a second switch operator and an S&C Micro-AT Source-Transfer Control in Weatherproof Enclo sure to provide automatic source transfer for primary-selective overhead distribution systems. Switch operators equipped for compatibility with the Micro-AT Source-Transfer Control in Weatherproof Enclosure include the following features: A microswitch and actuator which monitor the posi tion of the switch operator internal decoupling mecha nism. Auxiliary switch contacts that determine whether an opening or closing operation is required when the source-transfer control signals the need for an operation. An auxiliary contact which operates coincidentally with the switch operator opening contactor and closing contactor to assure that once an operation is initi ated by the source-transfer control, that operation will be completed before any other operations can be performed. S&C Switch Operators Type AS-1A, when ordered to replace a manual operating handle or an S&C Switch Operator Moto-Draulic Type with separate gearbox (originally furnished to operate rotating-type operating mechanisms), require a flexible coupling to connect switch operator output shaft to vertical operating pipe of high-voltage switch. Order flexible coupling matched to size of vertical operating pipe Catalog Number SA 35629 5, SA-35629-6, SA-35629-3, or SA-35629-4 for 1Z\x0 IPS, 20 IPS, 2Z\x0 IPS, or 30 IPS, respectively. How to Order 1. Obtain the catalog number of the desired switch opera tor from page 3. 2. If accessories are desired, obtain the suffix letter of the desired accessory from the table on page 4. Add the suffix to the switch catalog number. For example, for a 115-volt 60-Hz Type AS-1A Switch Operator for use with an Alduti-Rupter Switch Rotating-Type Operating Mechanism, complete with space heater thermostat and position-indicating lamps, spec ify Catalog Number 38847R4-DKM. A Note on Operating Speed S&C Switch Operators Types AS-1A and AS-10 are highspeed operators, having maximum operating times as specified in the table on page 3. For power operation of S&C Alduti-Rupter Switches Outdoor Distribution, this high operating speed is required to provide sufficient moving-contact velocity in the interrupters to ensure full interrupting capability and long operating life. The operators high operating speed also provides adequate closing velocity to meet duty-cycle fault-closing ratings for the applicable switches as listed in Specification Bulletin 761-31. 2 S&C Specification Bulletin 769-31

SWITCH OPERATORS Types AS-1A and AS-10 (For S&C Alduti-Rupter Switches) Application High-Voltage Device S&C Alduti-Rupter Switches Rotating-Type Operating Mechanism S&C Alduti-Rupter Switches Reciprocating- Type Operating Mechanism Voltage Rating of High- Voltage Device 7.2 kv thru 46 kv 7.2 kv thru 46 kv Switch Operator Type AS-1Aa AS-10f Motor and Control Voltage 12 Vdc 48 Vdc 125 Vdc 115 V 60 Hz 230 V 60 Hz 12 Vdc 48 Vdc 125 Vdc 115 V 60 Hz 230 V 60 Hz 12 Vdc 48 Vdc 125 Vdc 115 V 60 Hz 230 V 60 Hz Operating Lever12 Sector Length, Inches 1 Applicable for Type AS-10 Switch Operators only. Operating lever travels in left-hand or right-hand sector as indicated, viewed from front (door side) of switch operator. Operating lever in the up position corre sponds to the closed position of the Alduti-Rupter Switch. 2 Refer to the -S8 or -S9 Standard Minor Modification appearing on the applicable Alduti-Rupter Switch erection drawing bill of material when selecting an or switch operator. Where bracket SA-39154 or SA-39155 is indicated, specify an switch operator; where bracket SA-39868 is indicated, specify an switch operator. Contact your nearest S&C Sales Office. 3 Based on minimum battery and external control wire size requirements specified in S&C Data Bulletin 769-60; operating time will be less if larger-than-minimum battery size and/or external control wire size is utilized. a Type AS-1A Switch Operators are normally furnished with an output shaft rotation of 90 degrees counterclockwise to open the associated Alduti-Rupter Switch. Please review the Alduti-Rupter Switch erection drawing to verify that this is the correct direction of rotation for this application. If opposite direction of rotation is required, please so indi cate when ordering the switch operator. Maximum Operating Time, Seconds3 Minimum Locked- Rotor Torque at Rated Control Voltage, Inch-Lbs. 18 500 18 500 18 500 Accelerating Current, Amperes 80 30 46 23 80 30 46 23 80 30 46 23 Catalog Number 38854R4h 38847R4-A 38847R4-B 38847R4-D 38847R4-E 38855R4h 38852R4-A 38852R4-B 38852R4-D 38852R4-E 38856R4h 38853R4-A 38853R4-B 38853R4-D 38853R4-E Schematic Wiring Diagram Drawing Number CDR-3127R1 CDR-3127R1 CDR-3127R1 Page Reference for Dimensional Information f This switch operator has output characteristics equivalent to a linear actuator having a stalled-force rating of 4000 pounds (for 12-volt dc mod els), 4600 pounds (for 48-volt dc and 125-volt dc models), or 3800 pounds (for 115-volt 60-hertz and 230-volt 60-hertz models); a stroke length of 9 inches; and a typical operating speed of 12 inches per second at mid-stroke. l Applicable to Alduti-Rupter Switches with operating-mechanism rotation of 90 degrees; operating time will be greater if switch has increased operating-mechanism rotation. Typical running speed of switch operator output shaft: 26 revolutions per minute. h Includes 12-volt dc battery and constant-burden battery charger for connection to an S&C 30-Volt-Ampere Potential Device or other 120-volt 60-hertz source. n CDR-3205R1 for Catalog Numbers 38847R4-D, 38847R4-E, 38852R4-D, 38852R4-E, 38853R4-D, and 38853R4-E when furnished with source-trans fer control compatibility (suffix -U1 ). 5 6 S&C Specification Bulletin 769-31 3

ACCESSORIES FOR SWITCH OPERATORS Types AS-1A and AS-10 Item Suffix to be Added to Switch Operator Catalog Number Deletion of Externally Operable Open-Close Pushbuttons -J Space Heater Thermostat -K Key Interlock with Switch, locks Alduti-Rupter Switch open and disconnects motor-control circuit1 -L International Crating. Wood products used in the packaging are either hardwood or certified by the wood supplier as being heat treated (kiln dried) to a core temperature of 133 F (56 C) for a minimum of 30 minutes -L71 Position-Indicating LED Lamps (one red, one green), mounted inside the enclosure -M Extra Auxiliary Switch (individually adjustable contacts), 4-PST (coupled to motor)12 -Q Source-Transfer Control Compatibility. Permits use of switch operator with S&C Micro-AT Source-Transfer Control in Weatherproof Enclosure13 -U1 Duplex Receptacle and Convenience-Light Lampholder with Switch -V Extra Auxiliary Switch (individually adjustable contacts), 8-PST (coupled to Alduti-Rupter Switch)4 -W Remote-Control Blocking Switch, prevents remote operation of switch operator when the protective cover for the externally mounted open-close pushbuttons is open1 -Y Extra Auxiliary Switch (individually adjustable contacts), 12-PST (coupled to Alduti-Rupter Switch)4 -Z 1 Type AS-1A and Type AS-10 Switch Operators specified with sourcetransfer control compatibility (suffix -U1 ) cannot be furnished with key interlock with switch (suffix -L ), extra auxiliary switch coupled to motor (suffix -Q ), or remote-control blocking switch (suffix -Y ). 2 Required for some automatic-transfer and sectionalizing schemes. 3 Available as an optional accessory only with Type AS-1A and Type AS 10 Switch Operator Catalog Numbers 38847R4-D, 38847R4-E, 38852R4-D, 38852R4 E, 38853R4-D, and 38853R4-E, utilizing 115-volt 60-hertz or 230-volt 60-hertz motor and control voltage. 4 The 8-PST extra auxiliary switch (suffix -W ) cannot be furnished if the 12-PST version (suffix -Z ) is specified, and vice versa. PARTS Constant-Burden Battery Charger For Charging Battery Rated1 Catalog Number 12 volts dc MA-1050 1 The S&C Constant-Burden Battery Charger is intended for use with S&C Switch Operators Types AS-1A and AS-10 ordered for 12-volt dc operation with an automotive-type battery rated 80 ampere-hours or less, such as a Gould Mainte nance-free Truck Battery, part number C27-GNB. Although this battery charger is specifically designed for use with an S&C 30-Volt-Ampere Potential Device as its power supply, other 120-volt, 60-hertz sources may be utilized. 4 S&C Specification Bulletin 769-31

Type AS-1A Switch Operators a 12-volt dc switch operator includes battery compartment with separate access door, and with conduit-entrance area located on the left. S&C Specification Bulletin 769-31 5

Type AS-10 Switch Operators 6 S&C Specification Bulletin 769-31 a 12-volt dc switch operator includes battery compartment with separate access door, and with conduit-entrance area located on the left.