Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Similar documents
7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

7 Lighting Technology

7 Lighting Technology

Compact Sheet-Steel Light Fittings Series 6114

Sheet Steel Emergency Light Fitting Series 6018

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

7 Lighting Technology

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Ex UPS standard Series 8265

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

LED Linear Luminaire Series EXLUX 6402

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6402/2

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Leading the way in hazardous areas Features EATON

Portable Lamps Series HS6145, HSL145

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

I Ex-Safety switches I

Plug and Socket Devices SolConeX 16 A Series 8570

Linear fluorescent luminaire LED V-CG-S

I Ex-safety switches I

10 Load and Motor Switchgear

Safety Switches Series 8537

Easy and safe installation

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

9 Control Equipment. Control Unit System Series ConSig 8040

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

I Ex-safety switches I

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

International approvals.

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

EX-RECESSED CEILING LIGHT FITTINGS

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Battery Boxes Series 8316

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Load disconnect switch Series 8146/5-V11

Emergency Light Fittings

Floodlight LED Series 6125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

PROTECTA III. Construction Tough glass reinforced polyester body

Installation Accessories

Unused flameproof threads for cable glands have to be closed with certified plugs.

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

EXEL-L. Detail of the internal side. Transparent polycarbonate

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear Luminaire for Fluorescent Lamps

7 Lighting Technology

A good connection. International approvals.

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Type Scope of delivery Order unit Order No.

Internationally approved.

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Emergency lighting units EM LED Light Engines

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

HTSB system System overview

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Transcription:

Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating modes Non-maintained operation Non-maintained operation with switchable emergency light blocking Maintained operation With or without self-test function For fluorescent lamps 8 W, x 16 mm, for two-pin holder G5 Suitable for wall and ceiling mounting Can be fitted to order with emergency exit signs Central locking All-pole disconnection via N/C switch when fitting is opened Enclosure in polyester resin; cover in polycarbonate compact emergency lighting fitting can be used for safety illumination, but also as information or emergency exit sign lights. Zone 1 and Zone 2 /26

Compact Emergency Light Fittings Selection table ersion Lamp Self-test Battery Emergency Rated voltage Ordering code Weight function capacity light duration [kg] C-LUX 6108 Compact emergency light fitting for Zone 1 and Zone 2 1 x 8 W with 2 Ah 1 h AC 6108/1081-80 3-3,2 1 x 8 W without 2 Ah 1 h (50 / 60 Hz) 6108/1081-80 4-3,2 1 x 8 W with 4 Ah 1,5 h 220-10%... 6108/1081-80 - 3,5 1 x 8 W without 4 Ah 1,5 h 254 + 6%, 6108/1081-80 8-3,5 Add. to ordering code Cable entries Standard: 1 x cable gland M25 x 1,5 1 2 x plugs M25 x 1,5 Special: specify non-standard entries in writing 9 Emergency exit only needed when used as information or escape sign lighting; With adhesive symbols positioned as follows. Mounting postion Standard Cable entries Hinge Z253K A this side down Special: Please specify other positions in writing Please specify emergency exit sign number (see below) Emergency exit sign Symbol complying with GB 125, DIN 4844, DIN 5035; recognition distance e = 30 m; size 150 mm x 355 mm Illustration Colours Order No. suffix: Sign Background Emergency exit sign No. white green red white green X X 60 Note: Z2580K Z259K Z258K Z25K Z256K Z254K Z255K X X 61 X X 62 X X 91 X X 1 X X 81 X X 92 X X 2 X X 82 X X 90 X X 0 X X 80 X X 93 X X 3 X X 83 When delivered, light fittings are wired for maintained operation. By removing a bridge and connecting an external switch, the light fitting is converted to maintained operation with switchable emergency lighting. Fittings are supplied without lamps, which must be ordered separately. Further escape and information signs available on request. /2

Compact Emergency Light Fittings Technical data Marking CE Explosion protection II 2 G Ex eds IIC T4 Test certificate PTB No. 9 ATEX 2161 Lamps 1 x 8 W; two-pin fluorescent lamps, 8 W, 16 mm dia., for G5 holder Ballast Electronic ballast, single channel with integral emergency light electronics Rated voltage AC: 220-10%... 254 + 6%; 50 Hz / 60 Hz Rated current 0,15 A Back-up fuse for battery set 5 A, equipment fuse 8560/1 Working frequency 30 khz... 35 khz Ambient temperature charging 5 C... + 50 C lighting operation 20 C... + 50 C Material Enclosure glass fibre reinforced polyester resin; Colour: white, similar to RAL 9010 Cover Polycarbonate Gasket Polyurethane; foamed into cover Protection class I (with internal PE terminal) Degree of protection IP 66 / IP 6 Cover lock Central locking using socket spanner M8/SW13; cover hinged for access. Ballast supply, charging and battery circuit disconnected when central lock is opened. Central lock Cover hinge Z250K Connections Terminal marking Terminal size Light guide Disconnection of light fitting on opening faulty lamp Cable entries Standard Terminal block in polyamide with terminal cover L; N; PE; L I L I = charging phase charging phase must be connected at all times 2 x 4 mm 2, for solid cores 2 x 2,5 mm 2, for flexible cores Reflector painted white; Cover with prism structure, providing directed light from the fitting Central locking device with safety interlock; switch 8080 with N/C contacts; when central lock is opened, voltage to ballast is disconnected on both poles; a safety interlock in switching mechanism prevents fitting from being reconnected while cover and central lock are open. If lamp is faulty power supply is automatically switched off by electronic ballast 1 cable entry 8161 in plastic, M25 x 1,5 and 2 plugs 8290 in plastic, M25 x 1,5 8290 M25 x 1,5 8290 M25 x 1,5 Z251K 8161 M25 x 1,5 Cover hinge Special Other entries in moulded plastic or metal are available to order, details available on request /28

Compact Emergency Light Fittings Technical data Installation notes Looping through of cables 2 leads can be connected to each terminal on the input side, making fittings suitable for looped connection. Z252K Mounting Can be wall- or ceiling-mounted Operating modes Mains operation for general lighting or as information lights; Emergency operation: fed from battery-set built into emergency lighting fitting when used for escape route illumination or as emergency exit sign lighting. Emergency light electronics Incorporated in one housing with electronic ballast unit Options Emergency lighting electronics are available: with or without automatic self-test function; in maintained operation or maintained operation with switchable emergency lighting blocking. Interference suppression to DIN EN 55015 Self-test function C-LUX 6108 is available with or without self-test function. The built-in self-test functions are activated as soon as soon as light is connected to mains and automatically repeated after pre-set time has elapsed. Operating test Weekly test of emergency light function; battery and lamp faults are recognized and indicated via red LED. Emergency light duration test Testing of battery capacity at intervalls of 3 months; operating of fitting in emergency light mode for 2.3 rd of rated operating time. If the fitting is switches off by the discharge protection before time has elapsed. Battery cannot be used longer for emergency operation. Fault is indicated via red LED. Function indicators 1 red LED and 1 green LED, incoprorated in reflector; can be seen from outside through cover. Displays LED Indication Function green On Charging current flowing; everything ok flashing Emergency light duration test running 1 : 1 twinkling Automatic function test running 1 : 10 red On Rechargeable battery capacity insufficient; battery replacement necessany flashing Battery discharged; not operational 1 : 1 twinkling Battery defective 1 : 10 Battery charging current-regulated constant current charging, duration 20 h, then changeover to trickle charging. Exhaustive discharge at U Batt = 1 /cell (3 ); emergency light electronics automatically swtiches light off protection (DIN DE 0108) Charging voltage limit when a battery voltage of 1,55 / cell (4,65 ) is reached, charging ceases Emergency light operating Battery capacity Emergency light operation time period 2 Ah 1 h 4 Ah 1,5 h /29

Compact Emergency Light Fittings Technical data (Continuation) Emergency light electronics (Continuation) Maintained operation, When delivered the light fitting is wired for maintained operation; by removing the bridge Maintained operation with between terminals 1 and 2 and connecting external switch F, switchable emergency the fitting is converted to maintained operation with switchable emergency lighting. lighting Terminal emergency Terminals emergency lighting electronics lighting electronics Bridge External switch F Maintained operation Z2803K Z2804K Maintained operation with switchable emergency lighting Maintained operation On failure of supply to general lighting, fitting is supplied from the battery, (function) irrespective of the light switch position. Maintained operation On failure of power supply to general lighting, fitting switches to emergency with switchable emergency lighting operation only if external switch F is closed. To switch emergency lighting centrally lighting to ready or not ready, e.g. depending on plant operating times. The external switch has a potential-free NO contact. Non-maintained operation Emergency lighting is only operative when general lighting has failed; it is then supplied from the battery. Connections: L, N, PE (phase L not connected) Changeover voltage from mains to battery operation at U < 0,6 x U N from battery to mains operation at U > 0,9 x U N Lighting power on emergency Emergency light operation time Emergency light power operation 1 h 55% 1,5 h 0% Battery set built into light fitting Type NiCd battery, gas tight Capacity 2 Ah or 4 Ah Operating voltge 3,6 Charging battery set When the central lock is opened the battery set is de-energized; it can be removed from the housing by unplugging its removable contact. Emergency exit sign Use for information and escape sign fittings Material Foil, self-adhesive, printed with various pictograms in different colours Recognition distance e = 30 m Mounting Foil is stuck to cover externally Options The various types of adhesive foil which can be supplied are detailed on page /2 /30

Compact Emergency Light Fittings Dimensions (in mm) M1121K Additional dimensions for cable entries 8161 and plugs 8290 Emergency exit sign a [mm] M1119K 8161 M25 x 1,5 32 8290 M25 x 1,5 6 Positions of cable gland and plugs M1120K /31