Load Table See attached wiring diagrams:

Similar documents
The Advantage and Optimum Dual and Quad Pumps and The Advantage Super-Hi Dual Pumps

Available Models and Weights

Dimension Series One, Two, Three and Four Grade Dispensers

Related Manuals Pump and Dispenser Start-Up/Installation Manual Flow Restrictor Installation Manual

Highline Super-Hi High Gallonage Model No. Description. Load Table. Operating Environment. Performance Requirements

Highline Standard Gallonage Dispenser. Load Table. Operating Environment. Performance Requirements

The Advantage Series. Pump & Dispenser Specifications MDE-3807A

PT Optimum Series Illustrated Parts Manual

Nozzles Lane-oriented and High-hose Attachment Downloadable Software. Endress & Hauser LPG Mass DN15 Diesel Exhaust Fluid (DEF)

Salesmaker Series Pumps And Dispensers Illustrated Parts Manual

Standard Features and Options M07300A001*1, M07300A002*1, M07300A003*1, M07300A004*1, M07300A005*1, M07300A006*1

Nozzles Lane-oriented and High-hose Attachment Back-lighted Liquid Crystal Displays (LCD)

MDE-2833D. Pumps and Dispensers. Site Preparation For Use With: All Gilbarco pumps and dispensers

General information about underground storage tank (UST) fueling systems in every day language.

Purpose Of This Document This manual provides the information to assemble and install Lighted Canopy Conduit Kits on The Advantage Series.

High. performance. Encore

Franklin Fueling Systems

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

Conventional Fueling 11A 11B. 1A Automatic Nozzle

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

Portable Fuel Dispensing Equipment

GASBOY FLEET & COMMERCIAL

700 Series Hanging Hardware

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

Executive Orders VR-203-F and VR-204-F VST Phase II EVR System. Exhibit 5 Liquid Removal Test Procedure

INSTALLATION INSTRUCTIONS

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

Model 1210C Battery Powered Pump Shown

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

VST EVR Total Balance System Solution

Committee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508

Bennett Horizon 2 Series Electronic

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications

Leak Detector, Red Jacket #FX1V

Creating an ROI. from your EMV migration.

Control Valves/Meters Grease

PROJECT: Springhill & Canal Development (1950 E. Springhill Drive, Terre Haute, IN 47802)

Healy VP Troubleshooting Guide

Emergency Shear Valves

Vapor Recovery Assist System

Electronic Assemblies, Dials & Schematics. Electronic Enclosure Assembly (1 and 2 lamp system) , 3-3 (3 and 6 lamp system)...

Installation/Operation/Parts

Site Preparation Manual

TLS Consoles Point-of-Sale (POS)

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

4Fiilbarco. Illustrated Parts Manual. Salesmaker 4. Pumps & Dispensers PT1554 I DEC85

12 Volt DC Diaphragm Pumps Series 400

GILBARCO ENCORE 300 & 500 SERIES DISPENSER RETROFIT with VDC control valves for HEALY SYSTEMS, INC. MODEL VP1000 VAPOR RECOVERY ASSIST SYSTEM OUTLINE

LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

IMPORTANT INFORMATION

TLS Consoles Point-of-Sale (POS)

Bennett Pacific NV Series

Model 1200 Rotary Pumps. Repair Kit MDE-4432 (formerly )

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

Dresser Wayne Ovation Grade Model B 12/3, R 13/3

Installation Using Battery Clips

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

W-300-AST Specifications

STANDARD FOR TESTING AND RATING PERFORMANCE OF PRESSURE WASHERS: DETERMINATION OF PRESSURE AND WATER FLOW

The VST Enviro-Loc Vapor Recovery System

12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

Model 124 Quart Stroke Pump Operation / Parts Manual

Who we are, what we do

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS. Designed for you. world

SWCAA 492. Oxygenated Fuels

SK700-II THE COMPLETE DISPENSING SOLUTION. Building Better Business

STP-MLD Installation and Owner s Manual

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Series Low Pressure Steam Heating Boiler Safety Valves

2011 Alternative Fueling Infrastructure Catalog

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

Horizon. Dependable. Protecting. dispensing. your investment. Behind Every Successful Forecourt

Installation/Operation/Parts

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

Say hello to the Wayne Ovation 2 fuel dispenser

M-1115S Series Fuel Pump

FM-530-RD Remote Dispenser

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems

Vapor Recovery Central Vacuum System

Installation/Operation Manual

MR 5-30-RD Remote Dispenser

Above Ground Products Setting the Industry Standard for More Than 120 Years

Installation/Operation/Parts Manual

EVR Hose Configuration

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

M3500 Industrial Pressure Transmitter

Above Ground Products Setting the Industry Standard for More Than 120 Years

12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP

FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300 must accompany this application.

Smith Meter PD Meters 3" Steel Model E3

Powers TM Controls SW 141 Differential Static Airflow Switches

Fuel Dispensing & Accessory Packages

Please note: upgrades from older fluorescent backlit displays (Q ) will require PMP Adapter Kit #62071 or equivalent

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

Transcription:

The Advantage MPD Single-Hose Dispenser For Bennett and Southwest Foundations Model Number B85 B84 Description The Advantage MPD Three-grade, single-hose (two-sided) The Advantage MPD Three-grade, single-hose (single-sided) Load Table See attached wiring diagrams: Domestic FE-270 The Advantage Series dispensers 110/115/120 VAC Operating Environment Relative Humidity..................................... 20% to 95% non-condensing Minimum Outside Ambient Temperature............................... -22 F (-30 C) Maximum Outside Ambient Temperature.............................. 131 F (55 C) Performance Requirements Delivery Rate *...................................... 12 gpm @ 26 psi inlet pressure (45 lpm @ kg/cm 2 inlet pressure) Meter Accuracy............................±.25% from 1.5 to 15 gpm (5.7 to 57 lpm) *Actual flow rates will depend on your specific installation and accessories used. Vapor Recovery Units United States EPA Flow Rate Limitation * The Environmental Protection Agency (EPA) has established regulations limiting flow rates for gasoline dispensers to a maximum of 10 gpm effective July 1, 1996. Per EPA, the burden of compliance with this regulation is the service station owner s responsibility. Since typical dispenser flow rates will vary with site installation and hanging hardware, Gilbarco is shipping flow limiters with each dispenser sold in the United States for field installation if needed. These flow limiters will reduce flow rates by 2 gpm to 3 gpm and allow compliance with this regulation when installed in a typical site with conventional STPs. Weights MPD Single-Hose Three-Grade Dispenser................... 910 pounds/410 kilograms MDE-2530-17E Pump and Dispenser Installation Addenda 06/98 Page i

R 7 4 1 8 5 2 0 9 6 3 The Advantage MPD Single-Hose Dispenser Model Number Breakdown Product B- The Advantage Series Family Member 0 - MPD Dispenser 1 - MPD Pump 2 - Dual Dispenser 3 - Dual Pump 4 - Quad Dispenser 5 - Quad Pump 6 - Blender Six-Hose Dispenser 7 - Blender Dispenser 8 - Single Hose MPD Dispenser A - Blender Pump Configuration 0-1-grade, 1-side 1-1-grade, 2-side 2-2-grade, 1-side 3-2-grade, 2-side 4-3-grade, 1-side 5-3-grade, 2-side 6-4-grade, 1-side 7-4-grade, 2-side 8-3 + 0 blender, 36" Frame, 2-side 9-3 + 0 blender, 48" Frame, 2-side A - 5 + 0 blender, 36" Frame, 2-side C - 3 + 1 blender, 48" Frame, 2-side D - 5 + 1 blender, 48" Frame, 2-side F - 3 + 0 blender, 48" Frame, 2-side J - 5 + 1 blender, 48" Frame, 1-side M -4 + 1 blender, 48" Frame, 2-side B X X Options Push-To-Start Nozzle Lever Activated Nozzle CRIND Card Reader Customer Programmable Preset Cash/Credit Pricing Full Vapor (Balance System) VaporVac Vacuum Assist Mechanical Totalizers Gallon Totalizers Metric Totalizers Imperial Totalizers Unlit Brand Panel Lighted Brand Panel Backlit Brand Panel Light Conduit (Canopy) Speaker Cash Acceptor Hose Retriever Cannot have both CRIND Card Reader and/or Cash Acceptor and Customer Programmable Preset. Unleaded Plus Super 87 89 93 Model number plate Options Full Vapor Cash Acceptor BalanceVapor Retriever Balance Ready U.S. Gal Tots Lever Activate Metric Tots Button Activate Imp Gal Tots CRIND Overhead Spkr Cash/Credit Cnpy Lgt Cndt Pump Preset MFG. BY GILBARCO, INC. GREENSBORO, N.C. Serial U.S.A. No. PA001020 For use with equipment specified in installation instructions. N.Y.F.D. C. of A. #4805 U L Model No. B05 DX Underwriters Power Operated Dispensing Device Labortories Inc. For Flammable Liquids No. H LISTED Page ii MDE-2530-17E Pump and Dispenser Installation Addenda 06/98

PRESS The Advantage MPD Single-Hose Dispenser Elevation Diagrams 53-13/16" 49-1/12" 31-5/16" 21" 9-1/2" Canopy Option 42" 23-1/2" Detail B 94" 95-3/16" 88-7/8" 60-1/2" 42-1/4" Detail A 16" 22" 25-1/4" 25-5/8" 48" 21-1/2" 32-3/8" Short Nozzle Cradles 36-1/8" Long Nozzle Cradles Revised Single-Line CRIND InfoScreen and Monochrome CRIND Detail B Detail A 24-3/4" 23" (Short 21-1/2" (Medium Nozzle Cradle) (Long Nozzle Cradle) Nozzle Cradle) 53-1/2" Base 53-1/2" Base Note: Gilbarco VaporVac and some Balance Vapor Recovery units use short nozzle cradles. Screening Specifications Lower Doors Overall: 22.94" H x 49.74" W Front Surface: 19.94" H x 42.25" W Canopy Option Front Surface: 9.5" H x 53.81" W Side Surface: 9.5" H x 31.31" W MDE-2530-17E Pump and Dispenser Installation Addenda 06/98 Page iii

Foundation Diagrams (For Bennett Foundations) Opening For 1" Vapor Recovery Pipe 22-1/2" 48" 45" 33" 16-1/2" (4) 13/16 x1-7/16" 21-1/2" 10-3/4" 18-1/2" 15-3/4" 12" 7-7/8" 6" 5" 2-1/2" Opening For 1/2" Speaker Conduit (Suggested Location) 11-9/16" 14-1/2" 6-1/16" 16" 24" 41-3/4" 4-15/16" 16" 20-7/8" (3) 1-1/2" Supply Unions (2-7/16" Up From Base) 2-3/4" (Optional, not required) (4) 3/4 x1 1/2" Opening For 1" Conduit (1) 1" Vapor Recovery Adapter 9-5/16" 1-1/16" FRONT VIEW FRONT J-BOX 1" Capped Elbow (supplied) This dimension is for use with a double poppet shear valve. 1-7/16" 9-3/4" SIDE VIEW Page iv MDE-2530-17E Pump and Dispenser Installation Addenda 06/98

(For Southwest Foundations) Opening For 1" Vapor Recovery Pipe 22-1/2" 48" 45" 33" 16-1/2" (4) 13/16 x1-7/16" 10-3/4" 7 7/8" 6" 4-31/32" (3) 1-1/2" Supply Unions (2-7/16" Up From Base) 21-1/2" 12" 15-3/4" 18-1/2" 5" 14-1/2" 2-3/4" Opening For 1/2" Speaker Conduit (Suggested Location) 24" 10" 11-3/4" 41-3/4" 20-7/8" (Optional, not required) (4) 3/4 x1 1/2" Opening For 1" Conduit (1) 1" Vapor Recovery Adapter 9-5/16" 1-1/16" FRONT VIEW FRONT J-BOX 1" Capped Elbow (supplied) This dimension is for use with a double poppet shear valve. 1-7/16" 9-3/4" SIDE VIEW MDE-2530-17E Pump and Dispenser Installation Addenda 06/98 Page v

Page vi MDE-2530-17E Pump and Dispenser Installation Addenda 06/98