Vacuum Circuit Breakers kv

Similar documents
Vacuum Circuit Breakers kv

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Operating conditions. Generalities. Normal operating conditions

Evolis offer Merlin Gerin

HD4. Gas insulated MV circuit-breakers kv A ka

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

0MV vacuum circuit breaker. 0Evolis 24 kv. 0User 0Manual. Creation Printed on 2008/07/17

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Air-insulated switchgear UniGear type ZS1

VD4 Installation and service instructions kv A ka

CPG.0 Single busbar gas-insulated cubicles

www. ElectricalPartManuals. com 3 to 17.5 kv Fluarc FG2 mastering electrical power FG2 630 A and 1250 A withdrawable FG2 630 A fixed

NIRAPOD 5. Vacuum Circuit Breaker. 630A A: 7.2kV - 12kV 20kA - 25kA kA 12AV20. current CHARGED CHARGED

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

PIX-H Metal-clad switchgear up to 17.5kV

HD4. Gas insulated MV circuit-breakers kv A ka

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

HD4. Gas insulated MV circuit-breakers kv A ka

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Masterpact NW DC Circuit Breakers

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Medium Voltage Distribution FBX. Gas insulated switchgear up to 24 kv. Technical Characteristics Catalogue 2011

TECHNICAL DESCRIPTION

cor Long Run Experience

VD4. Installation and service instructions kv A ka

Ensuring excellent switching capability and high quality with various advantages

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Metal Clad Air Insulated Switchgear

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Masterpact NW DC Circuit Breakers

Modular medium-voltage switchgear. NorMax

1. Safety practices General Introduction Standards...3

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

Pro-MEC Vacuum Circuit Breakers Vacuum Interrupter

Merlin Gerin MCset Metalclad switchgear with withdrawable circuit breaker 1-24kV

Medium voltage products HD4/R - HD4/RE MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Vacuum Circuit-Breaker Modules

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

DMX 3 -I 2500 switch disconnectors

Medium voltage vacuum circuit breaker. E-VAC series

NXPLUS C Single busbar. Maintenance-free for lifetime

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

MCset 4-24 kv Withdrawable SF6 circuit breaker

Contents. The RM6 range

Type SDV7 distribution circuit breaker family

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Memshield - ACB Ratings & Specifications

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

TECHNICAL DESCRIPTION

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ZX2 Gas-insulated medium voltage switchgear

MESG 12 / 17.5 / 24 / 36 KV

DBM Range 1500VDC (13,5kA to 20kA)

CBGS-0. Medium voltage distribution

33KV INDOOR SWITCHGEAR

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

EMPAC Metal enclosed capacitor bank for wind applications

Solid Dielectric, Single Phase Recloser

CP Automatic capacitor bank

GMA. Medium-voltage switchgear

3 - Protection components Motor circuit-breakers

Horizontal Circuit Switchers

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

I B D Q I B D Q O I B D Q O

Medium Voltage Distribution. Rollarc R400-R400D contactor 1 to 12 kv

Horizontal Circuit Switchers

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

with Vacuum Circuit Breaker HAF

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Type SDV7 distribution circuit breaker family Answers for energy.

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Transcription:

Medium Voltage Distribution Vacuum Circuit Breakers 12-24 kv Evolis withdrawable version Catalogue 2015

General Presentation As a specialist in breaking technologies, Schneider Electric took naturally an interest in vacuum breaking techniques. A major R&D investment was made to develop and engineer Evolis, providing customers with the very best of vacuum technology. DE60163 DE60164 Ceramic chamber Shield Fixed contact Mobile contact Metal bellows Fig. 1: vacuum interrupter components (24 kv internal coil type) Current Electrode AMF coil Contact disk Arc plasma Axial magnetic field Make-up of a vacuum interrupter Vacuum interrupters basically have two electrical contacts (fig.1), one fixed and the other mobile, and a sealed enclosure. The latter enables a high level of vacuum to be maintained inside the interrupter (less than 10-7 bar) to provide insulation between the open contacts. The dielectric strength of the vacuum allows the contact-to-contact distance to be reduced. This short distance together with the low opening speed allow the use of a low energy control mechanism. A metal clusters provides the link between the mobile contact and the enclosure. In order to keep the vacuum level required for the correct operation of the interrupter for 30 years, the enclosure must be perfectly sealed, and the various components have to be fully degased. This is achieved by: choosing materials that are specifically selected for this application (metals and ceramics) choosing an appropriate assembly process (vacuum, high temperature brazing) the use of a getter material to absorb the residual gas. Current breaking in a vacuum interrupter In vacuum breaking, the electrical arc generated on separation of the contacts is made up of a plasma of metal vapors produced by the vaporization of the contact material. At low values of current, these vapors very quickly condense on the shield and contacts when the arc disappears, thus allowing: the vacuum to be re-established a contact-to-contact dielectric strength to be restored that is greater than the recovery voltage: breaking is then complete. At high currents, the electrical arc in the vacuum switches to a concentrated mode which causes high, localized temperature rises on the contacts. The existence of these hot spots is detrimental to the quick restoring of the dielectric strength. Two techniques can be used in order to avoid this stagnation of the static concentrated arc: the so called RMF (Radial Magnetic Field) technique, involves rotating the arc thanks to an electromagnetic effect generated by a radial magnetic field; this therefore limits contact erosion. a more recent technique called AMF (Axial Magnetic Field) involves applying an axial magnetic field parallel to the axis of the two contacts (fig. 2) which allows a diffuse arc to be maintained (fig. 3) even at high current values. The arc energy is spread over the whole contact surface area, therefore causing very low levels of erosion. Schneider Electric has chosen this last technique for the Evolis range. PE60042 Fig. 2: cross-section of AMF contact Fig. 3: diffuse vacuum arc AMF technology AMF technology Evolis circuit breakers use AMF type vacuum interrupters. According to technical and economic optimization considerations, the axial magnetic field is generated: either by a coil outside of the interrupter (fig. 4), for rated voltages up to 17.5 kv or by a coil integrated in the interrupter contact structure (fig. 1), for the 24 kv voltage level. In both cases the AMF vacuum interrupters feature low arc voltages (Uarc of around 50 V) and maximum usage of the contact surface for very low contact erosion. 200110 The advantages provided The above choices provide customers with the following advantages in MV circuit breaker applications: simple and compact vacuum interrupters CuCr materials as main contacts in the interrupter for lower chopping current and low surge during breaking high electrical endurance meaning that there is no need for contact wear inspection in normal network protection applications including highly disturbed overhead line feeders. Fig. 4: 12 kv/17.5kv external coil type interrupter 01

Performance Tables Common according to IEC 62271-100 rated frequency short-time withstand current rated peak withstand current rated short circuit making current operating sequence operating times mechanical endurance electrical endurance opening breaking closing class number of operations class number of operations capacitive current breaking Humidity: average relative humidity 24-hour period 1 month Electrical according to IEC 62271-100 circuit breaker rated voltage 1 Ur (kv) rms power frequency withstand (50/60Hz 1min) Ud (kv) rms lightning impulse withstand Up (kv) peak rated short-circuit breaking current 2 Isc (ka) rms / 3s rated normal current (-25 0 C +40 0 C) Ir (A) rms climatic version -25 0 C +40 0 C Installation and Connections phase distance between poles (mm) dimensions C.B with cradle (mm) width (W) depth (D) max. with ES height (H) fr Ik for tk = 3s Ip Evolis 12P1 630 12 28 75 25 630 145 600 1090 940 (Hz) (ka) rms peak (ka) peak (ka) mass C.B. with cradle (kg) 167 168 1 17.5kV is also available, please contact us for more information. 2 Three-phase breaking capacity = Ur x Isc x 3 (MVA), Ex: 12kV x 25kA x 3 = 520MVA. LV connections plug ms ms ms 16 ka 25 ka 31.5 & 40 ka Evolis 12P1 1250 12 28 75 25 1250 145 600 1090 940 50 & 60 Ik = Isc Ip = 2.5 & 2.6 Ik = 2.5 & 2.6 Isc O - 3 mn - CO - 3 mn - CO O - 0.3 s - CO - 3 mn - CO O - 0.3 s - CO - 15 s - CO < 50 < 65 < 70 M2 10,000 (30,000 upon request) E2 100 100 100 class C1-C2 (for some applications) < 95% < 90% Evolis 630 24 50 125 16 630 250 900 1472 1200 267 Charging lever Evolis 630/1250 24 50 125 25 630/1250 250 900 1472 1200 268 Closing button Opening button Cluster connecter Operation counter Circuit-breaker position indicator Control mechanism status (spring charged or discharged) Push-to-unlock operating crank plug Epoxy arm 1. manufacturer 2. breaker type 3. rated voltage 4. rated insulation voltage 5. rated current Nameplate 6. rated short-circuit current 7. rated frequency 8. control voltage 9. serial number 10. standard 11. date of manufacture Racking truck 02

Function Description Fig.1: service position Composition The racking in function is provided by: the racking truck supporting the circuit-breaker (mobile part), the cradle including the bushings (fixed part), the LV plug. The allowable voltage range for all electrical operations of the circuit-breaker is within 85% ~ 110%Un. auxiliary contacts for 12kV: 3NO+3NC (3C) or 6NO+6NC (6C) option auxiliary contacts for 24kV: 5NO+5NC (4NO+4NC+1CHG) antipumping relay operation counter Operating Procedure The circuit-breaker moves through 2 stable positions: service position: circuit-breaker racked in and locked in place; low voltage plug connected. test position: circuit-breaker racked out and locked in place; low voltage plug connected. Fig.2: test position Fig.3: push-to-unclok racking in & out mechanism Fig.4: epoxy casting bushing & earthing switch (option) Fig.5: insulation arm and cluster connecter Safety Functions A propulsive system combined with a screw-shaft makes racking in and racking out easier. Interlocking In accordance with IEC standards 62271-100 and 62271-200, the following interlocking is provided: racking in or out is impossible unless the circuit-breaker is in the open position. circuit-breaker CANNOT be withdrawn when the main contacts are in closed position. the main contacts of the circuit-breaker are forbidden to be closed when: a. circuit-breaker is in the process of being withdrawn or led-in. b. circuit-breaker is between the test and service positions. c. circuit-breaker is between the test and disconnedted positions. racking in or out is impossible during breaker s charging procedure. Metal-clad enclosed cradle with epoxy casting bushing eusures the safest construction. Earthing is achieved throughout the whole racking in operation by means of the wheels of the racking truck. Protective shutters on the cradle prevent access to the racking fingers when the device is extracted (protection index: IP2X). For maintenance or test purposes, it is possible to: padlock the shutters in the closed or open position. Earthing Switch (option) It can be fixed on the cradle, allowing proper interlocking between the circuit-breaker and the earthing switch. auxiliary contacts for earthing switch, cctivated when earthing switch is in open or closed position. Optional Parts Position Contact (2 or 4 racked in/out), activated when circuit-breaker is in the test or service position. Condenser Tripping Device (CTD, 2000μF) providing DC power for the unit to trip when encountering power failure. Communication Output (RS485 RTU) monitoring operating conditions and positions of circuit-breaker and earthing switch, can also provide remote control of circuit-breaker Earthing Switch Interlock Protection Mechanism (when interlocked with another breaker): locking the breaker in test or disconnected position and forbidding it to be closed. Under Voltage Release Key Locking Device (OFF position locking, forbidden to rack in/out the cradle) Interlock and Padlock device (pushbutton locking, forbidden to close or open the breaker) Auto-Discharge Function: the spring of the circuit-breaker operating mechanism is automatically discharged when the circuit-breaker is extracted from the cubicle. This feature avoids unexpected closing of the circuit-breaker. Arc Protection Relay, faster response to trip CB at the beginning of fault arc generation. The cradle is developed by TOYO TECHNICAL CO. LTD., an official distributor of Schneider Electric. 03

Function Descriptions opening circuit DE57612EN (2) (4) (1) or (3) Composition The opening circuit can be produced using the following components: Shunt opening release (on energizing) (YO1) second shunt opening release (on energizing) (YO2) undervoltage release (YM) low energy release (Mitop). Shunt opening release (MX1 / YO1 and MX2 / YO2) Energizing this release causes instant opening of the circuit breaker. Operating mechanism Power supply Consumption 50/60Hz MX1/MX2 (12KV) 100...130 Vdc/ac, 200...250 Vdc/ac YO1/YO2 (24KV) 110/125 Vdc, 220Vdc, 220Vac V AC 0.85 to 1.1 Ur V DC 0.7 to 1.1 Ur V AC 160 VA V DC 50 W DE58092 Undervoltage release (MN / YM) This release unit causes the systematic opening of the circuit breaker when its supply voltage drops below a value less than 35% of the rated voltage, even if this drop is slow and gradual. It can open the circuit breaker between 35% and 70% of its rated voltage. If the release unit is not supplied power, manual or electrical closing of the circuit breaker is impossible. Closing of the circuit breaker is possible when the supply voltage of the release unit reaches 85% of its rated voltage. DE58093 Shunt opening release (1) Power supply MN (12KV) 100...130 Vdc/ac, 200...250 Vdc/ac YM (24KV) 110/125 Vdc, 220Vdc, 220Vac Opening 0.35 to 0.7 Ur Closing 0.85 Ur Consumption Triggering 200 (for 200ms) VA or W / V AC 400 VA -- / V DC 100 W Latched 4.5 VA or W / V AC 100 VA -- / V DC 10 W DE58094 Undervoltage release (2) Low energy release (3) Low energy release (Mitop) This release includes a low consumption unit and is specifically used with the Sepam 100LA self-powered relay ( REFLEX MODULE ), or the VIP relay. Power supply Direct current 0.6 A < I < 3 A Any tripping due to the Mitop release unit is momentarily indicated by an SDE type changeover contact (option). DE58098 Auxiliary contacts (4) Open/closed auxiliary contacts The number of contacts available depends on the options chosen on the operating mechanism. (see wiring diagrams) Contact characteristics Rated current Breaking capacity AC DC 220V (cosø 0.3) 110/220V (L/R 0.02s) 10A 1A 0.3A 04

Function Descriptions remote control DE57604 Function Remote control enables the remote opening and closing of the circuit breaker. (6) (7) Composition The remote control mechanism comprises: an electrical motor with gearing (MCH/M) a shunt closing release (YF) combined with an anti-pumping device an operation counter. DE58096 (5) Operating mechanism Electrical motor with gearing (MCH / M) The electrical motor carries out the automatic rearming of the stored energy unit as soon as the circuit breaker is closed. This allows the instant reclosing of the device after opening. The arming lever is only used as a backup operating mechanism in the case of the absence of the auxiliary power supply. The M3 contact indicates the end of arming operations. Power supply MCH (12kV) 100...125 Vdc, 100...130 Vac, 200...240Vac M (24kV) 110...127 Vdc/ac, 220...250Vdc/ac Consumption V AC/V DC V AC V DC 0.85 to 1.1Ur 180 VA (12kV), 380 VA (24kV) 180 W (12kV), 380 W (24kV) DE58092 Electrical motor and gearing (5) Shunt closing release (6) Shunt closing release (XF / YF) This release allows the remote closing of the circuit breaker when the operating mechanism is armed. Power supply Consumption XF (12KV) 100...130 Vdc/ac, 200...250 Vdc/ac YF (24KV) 110/125 Vdc, 220Vdc, 220Vac V AC V DC V AC V DC 0.85 to 1.1 Ur 0.85 to 1.1 Ur 160 VA 50 W The shunt closing release is combined with an anti-pumping relay that enables priority to be given to opening in the case of a permanent closing order. This thus avoids the device being caught in an uncontrolled opening-closing cycle. DE58097 Operation counter (7) Operation counter The operation counter is visible on the front panel. It displays the number of switching cycles (CO) that the device has carried out. Condenser tripping device Condenser tripping device (CTD, 2000µF) providing DC power for the unit to trip when encountering power failure. Condenser tripping device (CTD) Dimensions & fixing holes of CTD 05

Dimensions (Bushing Type) Cradle fixing holes Busbar (to be installed by customer himself) Earthing Switch (optional) Cradle Type Voltage (kv) Current (A) A B C D E F G H K P T MVCBE12 MVCBE12+ES MVCBE24 MVCBE24+ES 12 630 / 1250 600 940 210 740 250 390 205 540 550 145 24 630 / 1250 900 1188 268 1030 321 519 318 830 850 250 285 350 350 400 unit: mm The cradle is developed by TOYO TECHNICAL CO. LTD., an official distributor of Schneider Electric. 06

Wiring Diagrams Evolis 12kV 1a 1b 2a 2b end of charging indicator contact (option) Position Switch Test Service (option) 1c 2c For Earthing Switch (option) Evolis 24kV 1a 1b 2a 2b RS485 Module end of charging indicator contact Position Switch Test Service (option) (option) Auxiliary Contacts *21.22.23.24 can only be chosen for either auxiliary contact OR position switch 1c 2c For Earthing Switch (option) 施耐德電機授權經銷商 東技企業股份有限公司普得企業股份有限公司 總公司 : 台北市內湖區行愛路 68 號 6 樓 電話 :(02)8791-8588 中辦處 :(04)2296-9388 傳真 :(02)8791-9588 高辦處 :(07)227-2133 E-mail:toyotech@ms37.hinet.net 網址 :www.toyotech.com.tw As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Jun. 2016