Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy

Similar documents
Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy.

Type Pneumatic actuators

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

TYPE EK-EU SMOKE CONTROL DAMPER

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Parts and characteristics

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type Pneumatic actuators

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

VersaWall SlimLine 1750

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

V-2410 Three-Way Multipurpose Solenoid Air Valve

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

TM-11x1 Series Room Temperature Module

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

HBO Range Gamme HBO. Hall effect open-loop current sensors. Capteurs de courant à effet Hall boucle-ouverte. Technical argumentation

CSD Series Current Devices Split Core

M9300 Series Potentiometer Kits

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Multileaf damper with actuator

ThermaWall 2600 Primary components - back sections Composantes principales - traverses ou meneaux

VA9905 Actuator and VG1600 Series Six-Way Valves

VA-4233-AGx Series Electric Valve Actuators

3RB12. Betriebsanleitung Instructions. Bestell-Nr./Order No.: 3ZX1012-0RB12-1AA1 Ausgabe/Edition 01/2003. GWA 4NEB a

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Index. ThermaWall Thermally broken curtain wall - Capped and SSG 2 1 2"(63.5mm) profile SSG. Capped

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

RedBin-P Pressure switches 5 Pa Pa

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

UHC-202 Hardware Guide

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

M9109 Series Electric Non-spring Return Actuators

Servo solenoid valves with on-board electronics (OBE)

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

COMMISSION INTERNATIONALE DE KARTING - FIA

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

RVP-R- VAV controller. In explosion-proof version

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Plan de présentation CSITC RT

M9300 Series Electric Non-Spring Return Actuators

M9300 Series Switch Kits

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Solid Clamps Raccords orientables

Servo solenoid valves with on-board electronics (OBE)

Parent s Guide. This guide contains important information. Please keep it for future reference US

Vannes à commande pneumatique pneumatically piloted valves

INSTALLATION INSTRUCTION Bollard Light 12V

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

Servo solenoid valves with on-board electronics (OBE)

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

RedCos-P Pressure sensor 20 Pa Pa

M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Ceiling swirl diffusers

Fan Relay Board (FRBii) Assembly

Specification Grade Contemporary Wall Mount/Technical Installation Data

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Transcription:

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy Type Easy QUICK AND EASY HANDLING Control components for VAV terminal units, to be mounted on the terminal unit for easy operation Simplified ordering and on-site assignment to rooms as selection is based on the nominal size of the duct Rapid volume flow rate setting without additional device Indicator light simplifies functional checking Proven technology of the Compact volume flow controllers Suitable for constant and variable volume flows as well as for V min / V max switching APPLICATION Application Electronic volume flow controllers of Type Easy are compact, all-in-one control devices for VAV terminal units Dynamic differential pressure transducer, electronic controller, and actuator are fitted together in one casing Suitable for different control tasks depending on how the input for the setpoint value signal is used The output signals of the room temperature controller, central BMS, air quality controller or similar units control the volume flow rate setpoint

Override control by means of switches or relays Volume flow rate actual value is available as linear voltage signal Standard filtration in comfort air conditioning systems allows for use of the controller in the supply air without additional dust protection. Since a partial volume flow is passed through the transducer in order to measure the volume flow rate, please note: With heavy dust levels in the room, suitable extract air filters must be provided. If the air is polluted with fluff or sticky particles, or if it contains aggressive media, Easy controllers cannot be used Application Electronic volume flow controllers of Type Easy are compact, all-in-one control devices for VAV terminal units Dynamic differential pressure transducer, electronic controller, and actuator are fitted together in one casing Suitable for different control tasks depending on how the input for the setpoint value signal is used The output signals of the room temperature controller, central BMS, air quality controller or similar units control the volume flow rate setpoint Override control by means of switches or relays Volume flow rate actual value is available as linear voltage signal Standard filtration in comfort air conditioning systems allows for use of the controller in the supply air without additional dust protection. Since a partial volume flow is passed through the transducer in order to measure the volume flow rate, please note: With heavy dust levels in the room, suitable extract air filters must be provided. If the air is polluted with fluff or sticky particles, or if it contains aggressive media, Easy controllers cannot be used DESCRIPTION Construction LMV-D3AL-F for LVC 227V-024T-05-013 for LVC LMV-D3A-F for TVR 227V-024T-05-002 für TVR

227V-024T-15-002 for TVJ, TVT SMV-D3A for TVT LMV-D3A for TZ-Silenzio, TA-Silenzio, TVZ, TVA Operating modes Variable volume flow V V min max : minimum volume flow rate : maximum volume flow rate Constant value V min : constant volume flow rate V : 100 % max Signal voltage range 0 10 V DC Parts and characteristics Sensor for dynamic differential pressure measurements Mechanical stops for limiting the damper blade positions Actuators with overload protection Release button to allow for manual operation Construction LMV-D3AL-F for LVC 227V-024T-05-013 for LVC LMV-D3A-F for TVR 227V-024T-05-002 für TVR 227V-024T-15-002 for TVJ, TVT SMV-D3A for TVT LMV-D3A for TZ-Silenzio, TA-Silenzio, TVZ, TVA Operating modes

Variable volume flow V V min max : minimum volume flow rate : maximum volume flow rate Constant value V min : constant volume flow rate V : 100 % max Signal voltage range 0 10 V DC Parts and characteristics Sensor for dynamic differential pressure measurements Mechanical stops for limiting the damper blade positions Actuators with overload protection Release button to allow for manual operation TECHNICAL INFORMATION Function, Technical data, Order code, Produktbeziehungen FUNCTION Functional description VAV terminal units control the volume flow in a closed loop, i.e. measurement comparison control. The volume flow rate is determined by measuring the differential pressure (effective pressure). For this purpose the VAV terminal unit is fitted with a differential pressure sensor. The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (V ). nom

The volume flow rate setpoint value comes from a higher-level controller (e.g. room temperature controller, air quality controller, central BMS) or from switch contacts. Variable volume flow control results in a value between V and V. It is possible to override the room temperature control, e.g. by a complete shut-off of the duct. The controller compares the volume flow rate setpoint value to the actual value and controls the integral actuator accordingly. The volume flow rate parameters V and V can be set on potentiometers. min max Volume flow control The volume flow controller works independent of the duct pressure Differential pressure fluctuations do not result in permanent volume flow rate changes To prevent the control from becoming unstable, a dead band is allowed within which the damper blade does not move. The factory set volume flow rate parameters can be altered by the customer min max Functional description VAV terminal units control the volume flow in a closed loop, i.e. measurement comparison control. The volume flow rate is determined by measuring the differential pressure (effective pressure). For this purpose the VAV terminal unit is fitted with a differential pressure sensor. The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (V ). nom The volume flow rate setpoint value comes from a higher-level controller (e.g. room temperature controller, air quality controller, central BMS) or from switch contacts. Variable volume flow control results in a value between V and V. It is possible to override the room temperature control, e.g. by a complete shut-off of the duct. The controller compares the volume flow rate setpoint value to the actual value and controls the integral actuator accordingly. The volume flow rate parameters V and V can be set on potentiometers. min max Volume flow control The volume flow controller works independent of the duct pressure Differential pressure fluctuations do not result in permanent volume flow rate changes To prevent the control from becoming unstable, a dead band is allowed within which the damper blade does not move. The factory set volume flow rate parameters can be altered by the customer min max

Principe de fonctionnement Régulateurs Easy et Compact 1 Sonde de pression différentielle 2 Servomoteur 3 Régulateur de débit 4 Signal de valeur de consigne Régulateur Easy

1 Régulateur Easy 2 V max - Potentiomètre 3 V min - Potentiomètre 4 Voyant lumineux 5 Bouton-poussoir de service 6 Raccordements pour capteur de pression effective 7 Capot de protection 8 Axe de blocage Illustration : LMV-D3A-F

TECHNICAL DATA Easy controller LMV-D3AL-F Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 3.5 VA max. Power rating (DC) 2 W max. Running time for 90 120 150 s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC to 2014/30/EU, low voltage to 2014/35/EU Easy controller 227V-024T-05-013

Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC ± 20 % Power rating (AC) 5 VA max. Power rating (DC) 3 W max. Running time for 90 100 s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easy controllers LMV-D3A and LMV-D3A-F

Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 5 VA max. Power rating (DC) 2.5 W max. Running time for 90 110 150 s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easy controller 227V-024T-05-002

Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC ± 20 % Power rating (AC) 5 VA max. Power rating (DC) 3 W max. Running time for 90 100 s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easyregler 227V-024T-15-002

Versorgungsspannung (Wechselspannung) 24 V AC ± 20 %, 50/60 Hz Versorgungsspannung (Gleichspannung) 24 V DC ± 20 % Anschlussleistung (Wechselspannung) Max. 5 VA Anschlussleistung (Gleichspannung) Max. 3 W Laufzeit für 90 150 270 s Eingang Sollwertsignal 0 10 V DC, R > 100 kω a Ausgang Istwertsignal 0 10 V DC, max. 0,5 ma Schutzklasse III (Schutzkleinspannung) Schutzgrad IP 20 EG-Konformität EMV nach 2014/30/EU Easy controller SMV-D3A

Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 6 VA max. Power rating (DC) 3 W max. Running time for 90 110 150 s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Variants, Product details VARIANTS

Part number Type Type of VAV terminal unit M466EU1 LMV-D3AL-F LVC M466EU2 227V-024T-05-013 LVC M466ES1 LMV-D3A-F TVR M466DC3 227V-024T-05-002 TVR A00000053055 227V-024T-15-002 TVJ, TVT M466ES3 SMV-D3A TVT M466ES2 LMV-D3A TZ-Silenzio, TA-Silenzio, TVZ, TVA Régulateur Easy LMV-D3AL-F

Régulateur Easy 227V-024T-05-013 Régulateur Easy LMV-D3A

Régulateur Easy 227V-024T-05-002

Régulateur Easy 227V-024T-15-002 Régulateur Easy SMV-D3A

PRODUCT DETAILS The Easy principle The Easy principle Sélectionner la dimension nominale

Régler le débit La diode verte s'allume : c'est prêt! Electrical connection, Commissioning, Characteristics

ELECTRICAL CONNECTION Répartition du bornier 1, : terre 2 ~, +: tension électrique 24 V 3 w: signal de valeur de consigne 0 10 V DC 4 U: signal de valeur réelle 0 10 V DC INBETRIEBNAHME Commissioning Use the potentiometer to set the minimum or maximum volume flow rate on site Take the adjustment value from the volume flow rate scale (sticker on each VAV terminal unit) Comply with the volume flow rate control range, do not set a volume flow rate which is below the minimum flow rate Volume flow rate range of LVC, TVR, TZ-Silenzio, TA-Silenzio, TVZ and TVA: 10 100% Volume flow rate range of TVJ and TVT: 20 100% Once the VAV terminal unit has been installed and wired, and the volume flow rate has been set, the unit is ready for operation Remove the transparent cover of the Easy controller only temporarily for wiring and commissioning Commissioning Use the potentiometer to set the minimum or maximum volume flow rate on site Take the adjustment value from the volume flow rate scale (sticker on each VAV terminal unit) Comply with the volume flow rate control range, do not set a volume flow rate which is below the minimum flow rate Volume flow rate range of LVC, TVR, TZ-Silenzio, TA-Silenzio, TVZ and TVA: 10 100% Volume flow rate range of TVJ and TVT: 20 100% Once the VAV terminal unit has been installed and wired, and the volume flow rate has been set, the unit is ready for operation Remove the transparent cover of the Easy controller only temporarily for wiring and commissioning Échelle de réglage de débit pour TVR-Easy

Chaque unité terminale VAV porte un autocollant avec une échelle de réglage de débit afin de déterminer les paramétrages sur site (voir exemple : TVR-Easy, grandeur nominale 200). Les pourcentages se rapportent à la plage de réglage qui peut être utilisé. Régulation à débit variable Les débits requis doivent être réglés sur site. Si V est réglé plus haut que V, V est fourni en tant que débit min max min Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-18 TROX GmbH

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy constant, même en cas d'émission d'un signal de consigne. Si V est réglé sur 0 %, le débit en résultant se situera entre la coupure et Vmax. Si le signal de consigne chute en min dessous de 0,5 V DC, le clapet de réglage se ferme (coupure). Régulation à débit constant Le débit constant est défini avec le potentiomètre V. Dans ce cas, le réglage du potentiomètre V est sans importance. min max Variable de pilotage en provenance du système centralisé de gestion du bâtiment (GTB-GTC) Pour que le système centralisé de gestion du bâtiment pilote le débit, il faut régler le potentiomètre V potentiomètre V max sur 0 % et le sur 100 %. Si le signal de consigne chute en dessous de 0,5 V DC, le clapet de réglage se ferme (coupure). Étant donné que le signal de consigne peut ou ne peut pas être inférieure à 0,1 V DC, une régulation prioritaire est recommandée pour la fermeture. min Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-18 TROX GmbH

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy Réglage usine À la livraison, les unités possèdent des réglages V min = 40 % et V max = 80 %. CHARACTERISTICS Caractéristiques du signal de valeur de consigne Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-18 TROX GmbH

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-18 TROX GmbH