Workshop I. Tuning LNB s and OFA Systems

Similar documents
Diagnostic Tools for Gas Turbine CO and SCR Systems

NOx: Troubleshooting and Optimization of Combined Cycle SCR Systems

C C A. Combustion Components Associates, Inc.

Worldwide Pollution Control Association

Boiler Optimization and MATS Work Practices Requirements. McIlvaine Hot Topics September 27 th, 2013

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants

NOx Emission Control Options for ICI Boilers

2001 Conference on SCR and SNCR

TECHNICAL PUBLICATION

Retrofitting of Mitsubishi Low NOx System

Mitsubishi Hitachi Power Systems America. Coal to Gas Conversions

Boiler Fuel Firing System

OPTIMIZING THE COMBUSTION PROCESS IN A COAL FIRED POWER PLANT REDUCES NOX BEYOND GUARANTEE LEVEL

OPTIMIZING THE BOILER COMBUSTION PROCESS IN A COAL FIRED POWER PLANT UTILIZING FUZZY NEURAL MODEL TECHNOLOGY

Combustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction

TECHNICAL PUBLICATION SYSTEM IMPACTS OF BURNING PRB COAL IN A WALL FIRED BOILER WITH PRE-NSPS BURNERS

A&WMA, CA SCAQMD, Diamond Bar, CA. Challenges for Meeting New Lower Air Emissions

Reliant Energy Tangential Low NOx System at Limestone Unit 2 Cuts Texas Lignite, PRB and Pet Coke NOx

IMPROVEMENT OF COAL-FIRED GENERATION UNITS AT LAMMA POWER STATION FOR NOx EMISSION CONTROL

Converting to Natural Gas for MATs Compliance August 7, 2014

Craig A. Penterson Senior Staff Engineer Fuel Equipment Design Riley Stoker Corporation

OPERATIONAL CRITERIA AND BURNER MODIFICATIONS FOR ACHIEVING LOW LOAD UNSUPPORTED COAL FIRING ON TANGENTIAL AND WALL-FIRED UNITS


TECHNICAL PUBLICATION

MECHANISM OF NOx CONTROL

Steinmüller Engineering GmbH POWER-GEN Europe, Vienna

Chapter 5 Oxygen Based NOx Control

MEETING TODAY'S EMISSION STANDARDS WITH 198WS COMBUSTION TECHNOLOGY

Experimental Investigation of Catalyst Deactivation Below the MOT and Full Load Regeneration

INSTALLATION OF THE POWER INDUSTRY S FIRST COMMERCIAL ALTA SYSTEM FOR NO X CONTROL AT AMEREN S SIOUX PLANT

2007 Chevron and John Zink Company, LLC

UPDATED LOW NOx COMBUSTION TECHNOLOGIES FOR BOILERS, 2003

John Zink # United Kingdom

INDUSTRIAL APPLICATIONS OF GAS TURBINES Fall 2010 Course

BENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS

REDUCTION OF BOILER STACK PARTICULATE EMISSIONS AND SCRUBBER WATER FLOW USING LOW-SODIUM COAL

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar

Combustion Control Problem Solution Combustion Process

COMBUSTION EFFICIENCY

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

Lecture 7a: Large Scale Oxyfuel Demonstrations. G Hesselmann APP OFWG Capacity Building Course 5 th & 6 th February 2009, Daejeon, Korea

1. Introduction. 2. Boiler

California s Success in Controlling Large Industrial Sources

Commercial Operating Experience on an Activated Carbon Injection System

Achieving Ultra Low NO x Emissions in Boiler Burner Retrofits. Bill Gurski Rex Isaacs John Guarco

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

An ISO 9001 company IPB-EU ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ELECTRIC UTILITY INDUSTRY. BECK VIDEO Scan w/ Smartphone 1

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Chariton Valley Biomass Project Iowa Switchgrass Cofiring Update

The influence of Air Nozzles Shape on the NOx Emission in the Large-Scale 670 MWT CFB Boiler

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Commencement of the Commercial Operation of 600 MW Unit, "Hirono No. 5 Thermal Power Station of The Tokyo Electric Power Co., Inc.

Optimization Solutions in Thermal Power Plants

Protea Series. The green fuel oil additives for power generation

Combustion and Boiler Performance Assessment of Kardia Power Plant

Towerpak Boiler. The versatile boiler to burn virtually any fuel economically

Furnace-based optimisation of a lignite-fired steam generator

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

U.S. Chamber of Commerce

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97

Aggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS. For Hot Mix Asphalt Facilities

NUMERICAL ANALYSIS OF INFLUENCE OF SOFA ON NOX EMISSIONS FOR PULVERIZED COAL BOILER

AUTOFLAME Combustion Managment System

Capital and O&M Benefits of Advanced Multi-Function Catalyst Technology for Combustion Turbine Power Plants

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

FLAME COOLING AND RESIDENCE TIME EFFECT ON NO x AND CO EMISSION IN A GAS TURBINE COMBUSTOR

University Turbine Systems Research Industrial Fellowship. Southwest Research Institute

\Performance of the Regenerative Burners in BaoSteel 2050 Hot Strip Mill Furnace Baoshan, China

RECOVERY CHEM TM ECBLRBAC SPRING 2008 SAINT JOHN, NB

Weishaupt Low NOx Solutions for Boiler Applications

LOW NOx ROTARY KILN BURNER TECHNOLOGY : DESIGN PRINCIPLES & CASE STUDY

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

An ISO 9001 company IPB-MI ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES. BECK VIDEO Scan w/ Smartphone 1

IED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE

State of the Art (SOTA) Manual for Internal Combustion Engines

Coal Fired Boilers. Technologies for Improved Efficiency & Reduced Emissions. C.Jayadevan Bharat Heavy Electriclas Ltd. Tiruchirappalli, India

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

Development of super low-level NOx RT burner for annealing furnace TAKAHITO SUZUKI KUNIAKI OKADA

I. Tire Heat Generation and Transfer:

Development of the Micro Combustor

Alternative Fuels Can Significantly Reduce Costs

IPB-MI ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES

Presented at 1996 AFRC International Symposium, Baltimore, Maryland, September 1996 Development of a High Performance Versatile Low NOx Burner

Emission measurement equipment was from both Volvo and Veolia was installed in the test buses.

Boiler Burners For Commercial And Industrial Applications

Ignition Reliability in SGT-750 for Gas Blends at Arctic Conditions. Magnus Persson Combustion Expert / Distributed Generation / Sweden

Case Study. Modernising gas fired power plant boiler damper drives and damper bearings

Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2

FUEL FLEXIBLE, ULTRALOW-EMISSIONS COMBUSTION SYSTEM FOR INDUSTRIAL GAS TURBINES

Usage Issues and Fischer-Tropsch Commercialization

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

Worldwide Pollution Control Association. August 3-4, 2010

The New Coen Micro-NOx

Power Generation Flexibilisation Case Studies from Germany. By Ronald Rost & Arun Kumar Sarna

Real time measurements of ash particle emissions. David Kittelson, David Gladis, and Winthrop Watts

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

NOx-Beta Ultra Low NOx Burners

The Multipoint Continuous Monitoring system (MCM) and its application in the Prime Glass project

Transcription:

Workshop I Tuning LNB s and OFA Systems R. Thompson FERCo, Laguna Hills, CA 29 Reinhold NO x Roundtable Cleveland, Ohio February, 29 1

REQUIREMENTS FOR EFFECTIVE NO X OPTIMIZATION Comprehensive Diagnostic Evaluation of Factors Affecting NO x Emissions: - Coal Property Variability - Burner Pipe Coal Flow Distribution - Combustion Uniformity (Individual Burner and OFA Settings) - Post-Combustion NO x Control (SCR/SNCR Grid Tuning) - Plant Combustion Controls and Process Instrumentation - SCR Catalyst Performance Degradation and Catalyst Replacement Management 2

ROLE OF ADVANCED INSTRUMENTATION IN OPTIMIZATION Expedient Cost Effective NO x Emissions Diagnostics and Tuning - Real-Time Burner Pipe Coal Flow Distribution Measurement - Real-Time Economizer Exit O 2,CO, NO Profiles for Interactive Burner/OFA Tuning Using Multipoint Emissions Analyzer - Quick Turnaround Fly Ash LOI Analysis (Hot Foil Analyzer) - Rapid Cost Effective SCR/SNCR Tuning Using Real-Time Multipoint Emissions Analyzer - Periodic SCR Catalyst Activity Measurement Using In situ KnoxCheck Advanced Instrumentation System FERCo Uses Custom Proprietary Instrumentation in its NO x Emissions Diagnostics and Process Control Optimization 3

COMBUSTION DIAGNOSTICS AND TUNING 4

BOILER/BURNER COMBUSTION TUNING Measure Primary Air and Coal Flow Distribution to Burners Optimize Mill Performance and Coal Fineness Balance Coal Flow to Individual Burners Characterize/Reduce Air Inleakage Between Furnace and Economizer Exit Adjust Secondary Air Flow to Burners for Uniform Combustion Improve Instrumentation/Placement Modify Boiler Firing Practice Over Load Range 5

BOILER OFA TUNING Characterize the Emissions and Profiles for Varying Levels of OFA Establish Tradeoffs Between OFA Flow, NO x, CO, LOI and Operating O 2 Level Evaluate the Potential Non-Uniformity in OFA Distribution to the OFA Ports Bias the OFA Flow, if Necessary, to Achieve Uniform Combustion Evaluate OFA Settings and Combustion Uniformity over the Load Range 6

IMPACT OF NON-UNIFORM COMBUSTION Local Air-Rich Zones - High NO x Emissions Local Fuel-Rich Zones - High Ash Carbon Levels, CO, Slagging/Fouling Overall O 2 Level Dictated by Lowest O 2 Region Average O 2 is Higher than Necessary 7

BENEFITS OF UNIFORM COMBUSTION Lowest Overall LOI and NO x Emissions at Uniform Low O 2 Level Improved Boiler Efficiency Reduced Dry Gas Loss Reduced Combustible Loss Emission Control Equipment Performance may Improve 8

COMMON CAUSES OF NON-UNIFORM COMBUSTION Uneven Coal Flow Distribution Coal Pipe Orifices Riffle Box Configuration Coal Feeder Calibration or Bias Uneven Air Flow Distribution Air Register/Damper Settings Windbox Design, FD Fan Placement Air Register/Drive Motor Malfunction OFA Ductwork Configuration Air Heater Seal Leakage or Partial Pluggage Furnace Air Inleakage Before O 2 Probes 9

LIMITATIONS OF STACK (CEM) DATA Boiler Average Emissions Only, No Indication of Burner Zone Gradients No Direct O 2 or CO Measurement Typically Not Real-Time Data to Allow Interactive Burner and OFA Tuning Difficult to Evaluate Combustion Uniformity Downstream of the Air Heater

MULTIPOINT COMBUSTION DIAGNOSTICS ANALYZER (MCDA) 11

ANALYZER FEATURES AND BENEFITS Simultaneous Measurement at 12 Sample Points NO, O 2, CO - 12 Channels Each (36 Total) Real-Time Contour Plots of Gas Concentrations Identify Non-Uniform Combustion and Air Inleakage Burner and OFA Tuning in Interactive Mode 12

BOILER TUNING CASE HISTORY Boiler Configuration 165 MW Combustion Engineering, T-Fired Divided Furnace 16 OEM Burners, 2 Elevations Fixed Coal Pipe Orifices Test Coal Blended Eastern and PRB NO x Controls Candidate for Retrofit LNB and OFA 13

WHY BALANCE THE COAL FLOW TO BURNERS? Fuel Rich Burners are a Source of High CO and LOI Fuel Rich Burners Can also Cause Furnace Ash Deposits, Waterwall Corrosion, and Fouling in the Convective Section Furnace Wall Cleanliness is a Key Issue in Low-NO x Firing with PRB Coals (Derates and Outages can Occur) Air Rich Burners Produce NO x and Contribute to Boiler Efficiency Losses Low-NO x Burner Vendors Typically Require the Coal Flow Variation Between Burners Not Exceed ±1% for Each Pulverizer 14

P E R C E N T D E V I A T I O N F R O M M E A N TYPICAL IMPROVEMENT WITH ORIFICE MODIFICATIONS 4 32 24 16 8-8 -16-24 PULVERIZER 1&2 COAL FLOW DEVIATIONS -32-4 165 MW Unit A B C D E F G H BURNER PIPE NUMBER PRE-RETROFIT POST-RETROFIT 15

TYPICAL IMPROVEMENT WITH ORIFICE MODIFICATIONS (cont d) P E R C E N T D E V I A T I O N F R O M M E A N 4 32 24 16 8-8 -16-24 PULVERIZER 3&4 COAL FLOW DEVIATIONS -32-4 165 MW Unit K L M N O P Q R BURNER PIPE NUMBER PRE-RETROFIT POST-RETROFIT 16

BENEFITS OF REPLACEMENT COAL PIPE ORIFICES Pulverizer Type Initial Coal Flow Deviation Final Coal Flow Deviation Orifice Type Location F-W ± 11.7% ± 1.5% Fixed IL B&W ± 29.2% ± 4.3% Fixed OH C-E ± 25.4% ± 3.2% Adjustable CT C-E ± 28.3% ± 9.6% Adjustable CT B&W ± 16.1% ± 4.1% Fixed CT C-E ± 32.4% ± 4.4% Adjustable CT C-E ± 38.% ± 7.7% Fixed OH C-E ± 38.2% ± 8.3% Fixed MI B&W ± 22.8% ± 4.9% Fixed OH C-E ± 39.3% ± 11.3% Fixed OH F-W ± 31.5% ± 4.8% Fixed CT F-W ± 12.3% ± 3.6% Fixed CT 17

Depth, Ft. Depth, Ft. TYPICAL IMPROVEMENT IN COMBUSTION UNIFORMITY BASELINE ECONOMIZER EXIT O 2 (%) PROFILE 5 4 3 2 1 5 1 15 2 25 3 35 4 Width, Ft. POST ORIFICE REPLACEMENT O 2 (%) PROFILE 5 4 3 2 1 5 1 15 2 25 3 35 4 Width, Ft. 18

TYPICAL IMPROVEMENT IN COMBUSTION UNIFORMITY (continued) Depth, Ft. BASELINE NO c (ppm @ 3% O 2 ) PROFILE 5 4 3 2 1 5 1 15 2 25 3 35 4 Width, Ft. Depth, Ft. Width, Ft. 5 1 15 2 25 3 35 4 1 2 3 4 5 POST ORIFICE REPLACEMENT NO c (ppm @ 3% O 2 ) PROFILE 19

BOILER TUNING CASE HISTORY Boiler Configuration 26 MW Babcock & Wilcox, Front Wall-Fired 24 Low-NO x Burners (4 x 6), 6 Overfire Air Ports Adjustable Coal Pipe Orifices, Dynamic Classifiers Test Coal Blended Eastern and PRB Post-Combustion NO x Control Babcock & Wilcox SCR 2

BURNER FRONT COAL FLOW DISTRIBUTION D-19 1.9 C-2-8.8 C-21 1.3 C-22 17.6 C-23-1.1 D-24-8. D-13 5.5 B-14-3.2 B-15-1.2 B-16 7.2 B-17-2.8 D-18.6 A-7 1.6 E-8 3.9 E-9-5.9 E-1-4.2 E-11 6.2 A-12 -.2 A-1 1.4 F-2-5.7 F-3-16.5 F-4 15. F-5 7.2 A-6-11.8 South North +19.4% -13.8% -22.3% +35.6% +.5% -19.4% 21

SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. BASELINE BOILER EXIT EMISSIONS PROFILES UNIT 2 - ECON. O2 CONTOURS TEST MT1-277 MW, ALL MILLS, NORMAL O2 & SOFA TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. UNIT 2 - ECON. CO CONTOURS TEST MT1-277 MW, ALL MILLS, NORMAL O2 & SOFA TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. UNIT 2 - ECON. NO CONTOURS TEST MT1-277 MW. ALL MILLS, NORMAL O2 & SOFA TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. 22

SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. POST-TUNING BOILER EXIT EMISSIONS PROFILES UNIT 2 - ECON. O2 CONTOURS APRIL 12th TEST S21-265 MW, NORMAL O2 & SOFA, SCR BASELINE NO NH3 TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. UNIT 2 - ECON. CO CONTOURS APRIL 12th TEST S21-265 MW, NORMAL O2 & SOFA, SCR BASELINE NO NH3 TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. UNIT 2 - ECON. NO CONTOURS APRIL 12th TEST S21-265 MW, NORMAL O2 & SOFA, SCR BASELINE NO NH3 TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. 23

BOILER TUNING BENEFITS NO x Emissions As-Found NO x =.44 lb/mmbtu Post-Tuning NO x =.38 lb/mmbtu NO x Reduction = 13.6% Estimated NH 3 Flow Reduction = 16% SCR Inlet NO x Uniformity As-Found NO x RMS = 9.2% Post-Tuning NO x RMS = 4.2% 24

BOILER TUNING BENEFITS (continued) Boiler Efficiency As-Found Operating O 2 Level = 3.3% Post-Tuning Operating O 2 Level = 2.9% Fly Ash LOI Decrease from 1 to 15 percent to 7 percent Approximate Boiler Efficiency Improvement = 1% Boiler Operational Performance Reduced Ash Deposition, Less Frequent Sootblowing Reduced Spray Flows, Larger Attemperation Margin Improved Tube Metal Temperatures 25

BOILER TUNING BENEFITS (continued) Lower Inlet NO x to SCR Increased Compliance Margin with NO x Regulations Reduced Reagent Consumption, Cost Potential to Accrue Valuable NO x Credits NH 3 Slip Less Sensitive to NH 3 /NO x Maldistributions More Uniform Inlet NO x Profile to SCR Inlet NO x Probe Data More Representative Less Impact of Mill Performance on NO x Profile at AIG Improved Boiler Performance Lower Operating O 2 Level, Increased Boiler Efficiency Better Burner Air/Fuel Ratio, Reduced Slagging/Fouling, Lower LOI Reduced Fuel Consumption and Secondary Emissions 26

OVERFIRE AIR (OFA) TUNING Tangentially-Fired Boilers Wall-Fired Boilers Cyclone Boilers Other Designs 27

OFA INFLUENCE FACTORS (T-FIRED) OFA Flow Rate CCOFA/SOFA Configuration SOFA Yaw Angle SOFA Bias (Between Levels and Corner-to-Corner) SOFA Flow Distribution to Corners SOFA Damper Schedule Over Load Range SOFA Tilt vs. Burner Tilt (included angle) 28

OFA TUNING CASE HISTORY Boiler Configuration 24 MW Combustion Engineering, Twin Furnace 32 Low-NO x Burners, 16 each Furnace (4 Elevations) Separated OFA, Two Levels Test Coal 1% PRB 29

OFA MIXING AFFECTS CO, NO EMISSIONS Reheat SOFA Dampers, % Superheat SOFA Dampers, % 3

CO, ppm NOx, ppmc SOFA YAW ANGLE IMPACT ON CO EMISSIONS 14 12 1 8 6 4 2 1 95 9 85 8 As-Found Horiz 1 with 5 against Reheat SOFA Yaw Angle 75 As-Found Horiz 1 with 5 against Reheat SOFA Yaw Angle 31

CO, ppm NOx, ppmc FINE TUNING SOFA YAW ANGLE PRB COALS 25 9 2 88 15 86 1 84 5 82 As-Found Horiz 5 with 5 against Superheat SOFA Yaw Angle 8 As-Found Horiz 5 with 5 against Superheat SOFA Yaw Angle 32

OFA TUNING CASE HISTORY Boiler Configuration 155 MW Combustion Engineering, Divided Furnace 24 Low-NO x Burners, Three Elevations, 12 per Furnace Advanced OFA, Four Compartments, Highly Staged Test Coal 1% PRB Instrumentation Direct Measurement of OFA Flow to Each Elevation and Each Corner 33

INITIAL COMBUSTION DIAGNOSTICS Inspection of OFA Dampers/Controls Indicated Proper Operation Economizer Profiles Non-Uniform with High CO MCDA Combustion Profiles Indicated Stuck Damper Corner #8 OFA Damper Bias Tests Confirmed Non-Uniform OFA Flow 34

INITIAL COMBUSTION DIAGNOSTICS (CONTINUED) Balanced OFA to Each Furnace CO Dropped by 6%; LOI by 2 points Plant O 2 Probes in West Furnace Increased (1.5% to 2.5%) NO x Emissions were Unchanged 35

WEST, FT. EAST, FT. WEST, FT. EAST, FT. WEST, FT. EAST, FT. WEST, FT. EAST, FT. WEST, FT. EAST, FT. WEST, FT. EAST, FT. IMPACT OF STUCK OFA DAMPER UNIT 5, TEST W-3, POST-OUTAGE USOFA ONLY 167 MWg, NORMAL O2, ALL MILLS, WARRANTY ECONOMIZER EXIT CONTOURS UNIT 5, TEST T28, POST-OUTAGE MIXED SOFA 167 MWg, NORMAL O2, ALL MILLS, AA & SOFA BIAS ECONOMIZER EXIT CONTOURS O2,% (dry) TOP, FT. O2,% (dry) TOP, FT. 5 4 3 2 1 5 1 15 2 25 3 35 4 5 4 3 2 1 5 1 15 2 25 3 35 4 BOTTOM, FT. BOTTOM, FT. CO, PPM TOP, FT. CO, PPM TOP, FT. 5 4 3 2 1 5 1 15 2 25 3 35 4 5 4 3 2 1 5 1 15 2 25 3 35 4 BOTTOM, FT. BOTTOM, FT. NO, PPM TOP, FT. NO, PPM TOP, FT. 5 4 3 2 1 5 1 15 2 25 3 35 4 5 4 3 2 1 5 1 15 2 25 3 35 4 BOTTOM, FT. BOTTOM, FT. 36

OBSERVATIONS FROM HIGH OFA DIAGNOSTIC TESTS Distribution of OFA to Furnace Corners often is Uneven on Retrofit OFA Systems Direct Measurement of OFA Flow to Corners is Valuable in Tuning OFA Systems Inside Corners on T-Fired Divided Furnace Designs May Get Less OFA Flow than Outside Corners OFA Flow and Windbox Pressure Should be Monitored Over the Load Range to Confirm Desired Staging Modification to Plant O 2 Probe Locations May be Necessary Calculations and Display of OFA Staging on DCS is Recommended (not just damper position) 37

SOFA FLOW, LB/HR SOFA FLOW DISTRIBUTION OFTEN NOT EVEN 6 UPPER SOFA FLOW VARIATION BY CORNER - OEM SETTINGS 5 4 3 2 1 C1 C2 C3 C4 C5 C6 C7 C8 CORNER NUMBER 38

FLOW, LB/HR INSIDE CORNERS OF DIVIDED FURNACE STARVED Top SOFA Flow 3 25 2 15 1 5 Outside Inside 2 4 6 8 1 12 % DAMPER OPEN 39

SOFA FLOW, LB/HR SOFA DAMPER BIAS REQUIRED FOR IMPROVED COMBUSTION UPPER SOFA FLOW VARIATION BY CORNER 4 35 3 25 2 15 1 5 C1 C2 C3 C4 C5 C6 C7 C8 CORNER NUMBER 4

OFA, % (of total air) W.B. PRESS., IN. VARIATIONS IN OFA AND WINDBOX PRESSURE WITH LOAD OFA FLOW & WINDBOX PRESSURE VS. LOAD 4 3.5 39 3 38 37 2.5 36 2 35 34 1.5 OFA, % W.B press in. H2O 33 1 32 31.5 3 1 11 12 13 14 15 16 17 LOAD, MW 41

OFA, % (of total air) NOx, LB/MMBTU NO x VARIATIONS WITH OFA FLOW AND LOAD NOx AND OFA FLOW VS. LOAD 4.2 39.18 38.16 37.14 36.12 35.1 OFA, % CEM NOx lb/mmbtu 34.8 33.6 32.4 31.2 3 1 11 12 13 14 15 16 17 LOAD, MW 42

DAMPER, % SEPARATE SOFA DAMPER SCHEDULES BY CORNER 12 CCOFA, % open 1 8 6 4 2 SOFA 3 CORNER 1 DMPR POSITION, % SOFA 3 CORNER 2 DMPR POSITION, % SOFA 3 CORNER 3 DMPR POSITION, % SOFA 3 CORNER 4 DMPR POSITION, % SOFA 3 CORNER 5 DMPR POSITION, % SOFA 3 CORNER 6 DMPR POSITION, % SOFA 3 CORNER 7 DMPR POSITION, % 2 4 6 8 1 12 STEAM FLOW, KLB/HR SOFA 3 CORNER 8 DMPR POSITION, % 43

OFA INFLUENCE FACTORS (WALL-FIRED) OFA Flow Rate/Measurement Burner to OFA Spacing OFA Configuration Multiple Level Location Service Pattern Wing Ports OFA Port Swirl and Penetration Control Ash Deposits 44

OFA OPTIONS FOR FRONT WALL-FIRED BOILERS OFA FLOW OFA FLOW 45

OFA TUNING WALL-FIRED CASE HISTORY B&W 225 MW Front Wall-Fired 24 Low-NO x Burners (4 rows x 6 wide) OFA Ports on Rear Wall for Improved Mixing OFA Ports Equipped with Manual Controls for Sleeve Damper Opening, Core Air Damper Position, and Spin Vane Setting Sleeve Damper Settings Used to Distribute OFA Flow. Core Air Damper and Spin Vanes Used to Control OFA Penetration and Mixing 46

PRELIMINARY OFA COMBUSTION DIAGNOSTIS LNB s Tend to Have Longer Flames Than Original Burners Gas Flow from Lower Burner Rows Hugs Rear Wall of Furnace Economizer Emissions Profiles with Minimum SOFA Spin Show Large O 2, CO, and NO Gradients High SOFA Spin Provides Improved Mixing and Reduced CO Gradients 47

SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. EMISSION CONTOURS WITH MINIMAL SOFA SPIN O2, CONTOURS, % 6 4 2 5 1 15 2 25 3 35 4 45 CO CONTOURS, PPM 6 4 2 5 1 15 2 25 3 35 4 45 NO CONTOURS, PPM 6 4 2 5 1 15 2 25 3 35 4 45 48

SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. EMISSION CONTOURS WITH HIGH SOFA SPIN O2, CONTOURS, % 6 4 2 5 1 15 2 25 3 35 4 45 CO CONTOURS, PPM 6 4 2 5 1 15 2 25 3 35 4 45 NO CONTOURS, PPM 6 4 2 5 1 15 2 25 3 35 4 45 49

RESULTS OF ADDITIONAL SOFA TUNING TESTS Full-Load SOFA Parameter Range: SOFA Sleeve Position: 5% to 1% Open SOFA Disk Position: 2 to 6 Inches SOFA Spin Setting: 3 to 9 Degrees Reduced OFA Flow Reduced Penetration and Mixing Into Fuel Rich Burner Flow Up Rear Wall LOI Increased Due to Reduced Mixing, NO Increased Due to Reduced Staging High OFA Spin Improves Mixing, Lowers CO, Allowing Lower O 2 Operation Scrubbing Action of High OFA Flow Benefits LOI In Spite of More Fuel Rich Lower Furnace 5

L O I, % ( a v g. ) O F A, % LOI DEPENDENCE ON SOFA SLEEVE POSITION LOI DEPENDENCE ON SOFA SLEEVE D.E. KARN UNIT 2 - TUNE (2/2) 2 2 15 15 1 1 5 5 225 MW 2 4 6 8 1 SOFA SLEEVE, % LOI, % OFA, % 51

L O I, % ( a v g. ) O F A, % LOI DEPENDENCE ON SOFA DISK POSITION LOI DEPENDENCE ON SOFA DISK POSITION D.E. KARN UNIT 2 - TUNE (2/2) 2 2 15 15 1 1 5 5 225 MW 1 2 3 4 5 6 SOFA DISK POS, IN.. LOI, % OFA, % 52

L O I, % ( a v g. ) O F A, % LOI DEPENDENCE ON SOFA SPIN LOI DEPENDENCE ON SOFA SPIN D.E. KARN UNIT 2 - TUNE (2/2) 2 2 15 15 1 1 5 225 MW 5 2 4 6 8 SOFA SPIN, DEG. LOI, % OFA, % 53

L O I, % ( a v g. ) LOI DEPENDENCE ON OFA (VARIOUS SPIN COMBINATIONS) LOI DEPENDENCE ON OFA (SPIN) D.E. KARN UNIT 2 - TUNE (2/2) 2 15 1 5 225 MW 2 4 6 8 1 12 14 OFA, % 54

ASSOCIATED OFA TUNING CONSIDERATIONS High Spin Vane Settings Do Benefit CO Reduction but Increased Back Pressure Restricts OFA Flow and Penetration Reduced OFA Penetration and Mixing Inhibits Carbon Burnout OFA Ports Adjustments to Minimize CO Do Not Simultaneously Reduce LOI As One Might Expect Tradeoffs Between OFA Settings, CO, LOI, and Operating O 2 Level are Likely Fuel Blend Dependent Test Coal Blend was 45% Western/55% Eastern 55

SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. SOUTH, FT. NORTH, FT. FINAL TUNED SOFA CONTOURS KARN UNIT 2 - ECON. O2 CONTOURS TEST T35-26 MW, ALL MILLS, SOFA=1%, TUNED TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. KARN UNIT 2 - ECON. CO CONTOURS TEST T35-26 MW, ALL MILLS, SOFA=1%, TUNED TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. KARN UNIT 2 - ECON. NO CONTOURS TEST T35-26 MW, ALL MILLS, SOFA=1%, TUNED TOP, FT. 6 4 2 5 1 15 2 25 3 35 4 45 BOTTOM, FT. 56

OTHER OFA TUNING ISSUES Large Opposed Wall-Fired Boilers Two Elevations of OFA Better than One Checkerboard Pattern Enhances Mixing Calibrated OFA Flow Measurement to each Elevation is Important Compartmentalized OFA Windbox Designs Can Provide Added Flexibility Resolve Burner Pipe Coal Flow Balance Issues Before Tuning OFA 57

CONCLUSIONS Balancing the Coal Flow Distribution to the Burners is an Important Prerequisite to Burner Tuning Fuel Rich Burners can Create Hot Spots of Incomplete Combustion, Ash Deposits, Slagging/Fouling and Corrosion Uniform Combustion is a Key Element in Efficient Low-NO x Firing with Low-NO x Burners and OFA Systems The Distribution of OFA Flow to the SOFA Ports is Frequently Not Even on Retrofit OFA Systems 58

CONCLUSIONS (continued) OFA Tuning is Often More Time Consuming Then Burner Tuning to Achieve Optimum Combustion Boiler and OFA Tuning Frequently Involves Adjustments to Equipment that is Not Automatically Controlled A Real-Time Multipoint Combustion Diagnostics Analyzer can Reduce Boiler Tuning Test Time by a Factor of Three to Five 59