ELECTRICALLY INSULATED 14mm PROBE

Similar documents
ROTARY HEAD DIGITAL STEM THERMOMETER

CONTACT TACHOMETER User s ManUal CT6235B

Please read all of the installation instructions carefully before installing the product. Improper installation will void manufacturer s warranty.

12:1 WIDE-RANGE INFRARED THERMOMETER WITH STAR BURST LASER TARGETING

Instruction Manual. Backup Camera System With Replacement Mirror Monitor RVS

Instruction Manual. Backup Camera System With Replacement Mirror Display RVS N

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Instruction Manual. Backup Sensor Reversing System RVS-RS103

PIN-TYPE LCD MOISTURE METER

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

Instruction Manual. OEM Frameless Rear View Replacement Mirror Monitor with 7.2" Dual Display RVS Reverse With Confidence 1

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

DT304. Digital Temperature Logger INSTRUCTION MANUAL

CTFRP Series Power Supplies

User Guide IGD Series

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

MEX (55) QRO (442) Web Controls

Inductive. SeekTech Clamp WARNING! Operator s Manual

Wireless Video Inspection

RANGE HOODS USER INSTRUCTIONS

LEV/Wn Building A Connected World

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

MODEL 7400 STRUT SPRING COMPRESSOR

60 Watt Industrial LED Low Bay Light

MODEL 7600 STRUT SPRING COMPRESSOR

VFL-280. Visible Fault Locator. Operating Manual

SUBMERSIBLE MINI-PUMP

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Non-Contact Phase Rotation Tester

Owners Manual. LifeGuard Power Lift Model # Rev. 2/1/13

LIBERATOR USER MANUAL

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Owner s Installation Guide

A2P Single Phase Automatic Industrial Battery Charger

BroadBand PowerShield. 20 AHr Battery. User Manual

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Introduction RVS SYSTEMS

Owner s Manual & Safety Instructions

Defender 3000 Series Base Instruction Manual

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

EZ Carrier 3. Owner s Manual. Keep instructions for future reference

Operator s Safety and Service Manual

For technical questions and replacement parts, please call

Video & Power Over Coax Kit

INSTALLATION & OWNER'S MANUAL

Broadband PowerShield. CP27U Models. User Manual

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

OWNERS MANUAL HF4263

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

SPC-PANEL Simplex, Single Phase Pump Control Panel

Installation and Maintenance Instructions

EBG Series Surface Preparation Machines

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

2 Speed Hydraulic Hand Pump

#1034 Ford Sport Trac Installation Instructions

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

OWNERS MANUAL HF

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Portable 12V Jump Start Device Powered By KrankingKAP Supercapacitors REV. A

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

LifeGuardLift. LifeGuard Power Lift Model #100287A OWNERS MANUAL. Rev: 2/14/11

SLA Battery Capacity Analyzer

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

High Capacity Battery Charger

OUTDOOR SPEAKERS OWNER S MANUAL

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

LIFT NAME PART NUMBER SETBACK (min) SETBACK (max)

Tracer ORP PockeTester TM Code 1742

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

INSTALLATION INSTRUCTIONS

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Guardian HH Shaft Coupling

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

OPERATOR S MANUAL. 37 fpm 1000 POUNDS CAUTION POWERFUL LIGHTWEIGHT VERSATILE MODEL# OBH Complies with ASME B

OWNERS MANUAL HF4261

A48 / A48B (base plate) BATTERY CHARGER

OPERATING INSTRUCTION

Instruction Manual. Backup Camera System For Pickup Trucks. RVS-Pickup


ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc.

Visit us at

Installation Power Management Unit Battery Cables and Battery Harness

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

IMPROVED BUTTON CONTROLS NEW TOMAHAWK USER MANUAL

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

MetroPrime 22MPC Self-Priming Centrifugal Pump

Electrometer Lead Acid Battery Replacement

Pump Installation and Service Manual HRS Hydromatic Retractable System

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Guardian NV Flywheel Coupling

Transcription:

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com ELECTRICALLY INSULATED 14mm PROBE USER S MANUAL NOTE: ETL SAFETY RATING ONLY APPLIES TO THE DCS400 SERIES SYSTEMS. PE14 Please read this manual carefully and thoroughly before using this product.

INTRODUCTION Thank you for purchasing a PE14 Electrically Insulated Probe for your Seeker 400 Series (DCS400, DCS400-05 or DCS400-09) Wireless Recording Video Inspection System. Please read this user s manually thoroughly and carefully before using the product. The PE14 is a unique, electrically insulated, far-focus camera-tipped probe that gives the DCS400 system it is attached to an ETL safety rating of CAT III 1000V, CAT IV 600V. WARNING Although the PE14 probe is also compatible with the handle of Seeker 300, 200 and 100 (DCS300, DCS200 and DCS100) systems, attaching it to those systems does NOT upgrade their safety ratings. General does not advise and bears no responsibility for use of the PE14 probe with any system other than the DCS400. Working in concert with a DCS400, the PE14 makes it safe to inspect two kinds of environments: 1. Any area or enclosure where you would expect to find electrical wiring. Examples include junction and distribution boxes, circuit breaker panels, electrical cabinets, equipment chassis and enclosures, and motor control centers. Whether the wiring is exposed or hidden, it represents a potential hazard hazard to anyone operating a video camera scope with a conventional probe with a metal exterior. 2. Any area or enclosure where you would not expect to find electrical wiring, but exposed wiring nevertheless may be present. Examples include attics, crawl spaces, rafters, ducts and basements of houses in short, any area that is too inaccessible, confined or dark to be visible to the naked eye. 2

Such areas may contain electrical hazards created by age (worn insulation, e.g.) or structural modifications. The PE14 makes it possible to inspect electrically hazardous areas (as well as safe areas) using the capabilities and features of a Seeker 400 Series system. The probe has many applications in the automotive/boat/aircraft repair, plumbing, construction, restoration and HVAC/R industries. KEY FEATURES Attachment to DCS400 Series video camera scope gives entire system an ETL safety rating of CAT III 1000V, CAT IV 600V Flexible-obedient design lets user bend probe into different shapes and hold them to facilitate inspection of different areas 14mm diameter enables use in close quarters Wide depth of field of 1 in. (25mm) to infinity for clarity at all distances Adjustable LED lights inside probe tip illuminate dark spaces Water, dust, oil and scratch-resistant to IP67 standard 3

SAFETY INSTRUCTIONS WARNING DO NOT attach the PE14 to the handle of any video inspection system other than the DCS400, DCS400-05 or DCS400-09. Doing so does NOT upgrade the ETL safety rating of that unit. Doing so also voids the warranty of the PE14. If you have attached any of the three included probe tip accessories (the 45 mirror, the magnetic pickup, or the pickup hook), to the PE14, DO NOT use it to inspect any equipment or area known or suspected to contain live electrical wiring. Doing so could cause an explosive short-circuit that could cause serious equipment damage or personal injury. Before using the PE14 probe, carefully inspect it for any cuts, nicks or abrasions in its insulation. If you detect any flaws, discard the probe and purchase a new one. It is extremely important to inspect the probe for flaws before each and every use. WHAT S IN THE BOX The PE14 comes in a box with a package of three probe tip accessories (a 45 mirror, a magnetic pickup, and a pickup hook) and this user s manual. 4

ATTACHING THE PROBE To attach the PE14 probe to the handle (grip) of a DCS400 Series system, first roll the rubber insulation back from the connector end of the probe. Then line up the probe s alignment key with the flat on the coupling of the DCS400 s probe connector (left photo below). Push the two ends together until they mate. To secure the connection, turn the collar of the probe connector (right photo below). Finally, roll the yellow insulation forward until it covers both joined metal connectors. Make sure to extend the insulation until it reaches the grip's plastic housing (bottom figure). To detach the probe, reverse the process: After rolling back the insulation, turn the collar counterclockwise and pull the PE14 straight out from the DCS400 probe connector. USING THE PROBE To use the probe, follow the operating instructions for the DCS400 found in its user s manual. Before using a DCS400 system with a PE14, read the Safety Instructions section of this manual. 5

SPECIFICATIONS Type Flexible-obedient Length 3.28 ft. (1m) Diameter 14mm (0.55 in.) Camera Light Source 2 high-intensity white LEDs Camera Field of View 60 Camera Depth of Field 1 in. (25mm) to infinity Camera Resolution 640 x 480 pixels (still images); 320 x 240 pixels (video) Certifications Water, dust, oil and scratch-resistant to IP67 standard ETL CAT III 1000V, CAT IV 600V (only when used with DCS400 Series system) Tensile Strength >12mPa Breakdown Voltage 715kV/m Electrical Volume Resistivity 1 x 10 14 Ω-cm Operating Temperature -50 to 257 F (-45 to 125 C) @<80% relative humidity Weight 9.5 oz. (269g) OPERATING AND MAINTENANCE TIPS Please read the Safety Instructions on p. 4 carefully. The probe is flexible to help you operate in hard-to-reach areas. Never insert or bend it by force, and never over-bend any part of the probe. To avoid permanently damaging the delicate wires and optics inside the probe, keep its bending radius above 2 in. (50mm). Never use the probe or camera head to modify surroundings or to clear pathways or clogged areas. 6

The camera head and its cover are waterproof, but not acidproof or fire-proof. Do not touch acidic, corrosive or hot materials or they will ruin the camera head s protective plastic. Never place the camera head in contact with corrosive or oily places or high temperature objects. When inspecting a vehicle, shut off the engine. Metal and liquid under the hood may be hot. Don t get oil or gas on the camera head. Cover the camera-tipped end of the probe with the protective rubber cap when not using it. WARRANTY INFORMATION General Tools & Instruments (General s) PE14 Electrically Insulated Probe for Seeker 400 Wireless Recording Video Inspection Systems is warranted to the original purchaser to be free from defects in material and workmanship for a period of three years. Subject to certain restrictions, General will repair or replace this product if, after examination, the company determines it to be defective in material or workmanship. This warranty does not apply to damages that General determines to be from an attempted repair by non-authorized personnel or misuse, alterations, normal wear and tear, or accidental damage. The defective unit must be returned to General Tools & Instruments or to a General-authorized service center, freight prepaid and insured. Acceptance of the exclusive repair and replacement remedies described herein is a condition of the contract for purchase of this product. In no event shall General be liable for any incidental, special, consequential or punitive damages, or for any cost, attorneys fees, expenses, or losses alleged to be a consequence of any damage due to failure of, or defect in any product including, but not limited to, any claims for loss of profits. 7

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com