Preventive maintenance kits

Similar documents
Product Structure. ABB Industrial drives, ACS800-31

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help

ABB wind turbine converters. Supplement to hardware manual ACS upgrade kits

ABB industrial drives ACS800, drive modules 0.55 to 2900 kw Catalog

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Low voltage AC drives. ABB industrial drives ACS800, multidrives 1.1 to 5600 kw Catalog

ACS 800. Hardware Manual ACS Drives (75 to 1120 kw)

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U7 Drives (50 to 600 HP)

ACS 800. Hardware Manual ACS Drives (500 to 2800 kw)

ACS800. Hardware Manual ACS Drives (0.55 to 110 kw) ACS800-U1 Drives (0.75 to 150 HP)

ABB industrial drives ACS800, multidrives, 1.5 to 5600 kw

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U31 Drives (7.5 to 125 HP)

ABB industrial drive ACS800 multidrive, 1.5 kw kw ACS800 multidrive modules, 1.5 kw kw Technical catalogue

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

ACS800. Hardware Manual ACS Drives (55 to 2500 kw / 75 to 2800 HP)

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U7 Drives (50 to 600 HP)

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U2 Drives (60 to 600 HP)

ACS 800. Hardware Manual ACS Drives (0.55 to 110 kw) ACS800-U1 Drives (0.75 to 150 HP)

ACS800. Hardware Manual ACS Drives (45 to 500 kw) ACS800-U2 Drives (60 to 600 HP)

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

ABB SINGLE DRIVES ACS880-01/04 +C132 marine typeapproved. Supplement

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U11 Drives (7.5 to 125 HP)

ADJUSTABLE FREQUENCY CRANE CONTROLS

LS200 Series Instruction Manual

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

ACS 800. Hardware Manual ACS Drive Modules (90 to 500 kw) ACS800-U4 Drive Modules (125 to 600 HP)

Industrial Chargers and

R5 ACS580-01, ACH580-01

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Hardware manual Sine filters

Frequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp

PAF F280 SERIES Instruction Manual

Variable speed application guidelines

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

PAF500F24 SERIES Instruction Manual

Power Conversion System The Best Technology for your photovoltaic and storage system

ABB LOW VOLTAGE AC DRIVES, WIND TURBINE CONVERTERS AND SOLAR INVERTERS Converter modules with electrolytic DC capacitors in the DC link Capacitor

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Medium voltage drive for single or multimotor applications, 3 27 MW

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

ABB Component Drives ACS150, 0.5 to 5 Hp

Capacitor reforming instructions Converter modules with electrolytic DC capacitors in the DC link

Spring Pin Socket User Manual

Welcome to the Applications training module for the ACS800 Single drives. If you need help navigating this module, please click the Help button in

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

IGSM series micro inverters Reliability Analysis Report

Drive IT Low Voltage AC Drive. ACS 600 Catalogue SingleDrive ACS 600, 1.5 kw-3000 kw MultiDrive ACS 600, 2.2 kw-4300 kw Related tools and accessories

Drive IT ACS 1000i. Integrated Medium Voltage AC Drive

Three Phase UPS Systems Range: 10 to 500kVA

1. Inspection and Maintenance

RVS-AX Instruction Manual

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

Liebert. FP 50Z kva

Regenerative DC Common Bus Supply

ACS 1000, ACS 1000i. Medium voltage AC drives for control of induction motors from kw

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

Hydrovar and Packaged Hydrovar

PowerFlex 700 Drive - Frame 9 Components Replacement

ABB industrial drives ACS800, single drives, 0.55 to 5600 kw

Hardware Manual ACS 600. ACS/ACC/ACP 601 Frequency Converters 2.2 to 110 kw (3 to 150 HP)

UPS5000-E (25-75 kva) Series

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Power Conversion Systems. SCHAEFER International. Switchmode Power Supplies, Chargers & Inverters. Thyristor-controlled Power Supplies & Chargers

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

3 Maintenance. 3 Maintenance. 3.1 Introduction. 3.1 Introduction

MCW Application Notes 24 th August 2017

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

ABB component drives ACS150, 0.5 to 5 Hp

9.1.4 Troubleshooting of Faults in LCD Screen

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11)

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Electronic Ballast EVG 2000-T

ACS 800. Hardware Manual ACS Drives (90 to 500 kw) ACS800-U2 Drives (125 to 600 HP)

Mounting and Installation Guidelines

Company profile 2 Profile of ČKD ELEKTROTECHNIKA 2

CN100A110 SERIES Instruction Manual

Catalog. ABB industrial drives ACS800, single drives, 0.55 to 5600 kw

ABB Drive Services Your choice, your future

2W, Low Cost DIP, Dual Output DC/DC Converters

Energy sector DC LINK CAPACITORS AND SNUBBERS

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

3 Internal Frequency Converter Operation 43

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Product Data Sheet DV5214 NU

STR3. Step Motor Drive. User Manual

Preventive Maintenance Checklist of Industrial Control and Drive System Equipment

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Transcription:

ABB industrial drives ACS800 Preventive maintenance kits All rights reserved. Welcome to the ABB industrial drives, ACS800 Preventive maintenance kits training module. If you need help navigating this module, please click the button in the top right corner. To view the presenter notes as text, please click the Notes button in the bottom right corner.

Objectives After completing this module, you will be able to Define the aging components of the ACS800 Recall the preventive maintenance kits for the ACS800 List the actions of preventive maintenance kit replacement operations State the actions of preventive maintenance measurements and checkings All rights reserved. - 2 - After completing this module, you will be able to define the aging components of the ACS800, recall the preventive maintenance kits for the ACS800, list the actions of preventive maintenance kit replacement operations, and state the actions of preventive maintenance measurements and checkings.

Lifespan of ACS800 components All rights reserved. - 3 - Lifespan of ACS800 components The following pages list the aging components and the common aging phenomena of the ACS800 drives.

Lifespan of ACS800 components Cooling fans FAN ON-TIME New fan Reset counter Change intervals 6 years: Main cooling fan(s) diode (DSU), IGBT (ISU) supply modules cooling fans All rights reserved. - 4-3 years: ACS800-01, ACS800-11 and ACS800-104 IP21 and IP55 internal cooling fan ACS800-02 enclosure extension cooling fan Thyristor (TSU) supply modules main cooling fans Cooling fan capacitor In the ACS800 the cooling fans operate for a short time when the drive is powered up and when the run-command for the drive is active. The cooling fan operating hour counter, the signal named FAN ON-TIME, should be checked and compared with the actual age of the drive. Resetting of the counter is recommended when the fan gets replaced. This can be done by using the DriveWindow2 software (for resetting single drives see parameter 145.14 FAN LIFETIME LIM / In system software see parameter 16.09 RESET COUNTER). The main cooling fan for the heat sinks needs to be replaced every six years. The Change interval for internal or additional cooling fans are three years. Note that in the case of separate cooling fan starting capacitors, they should also be replaced when changing the fan.

Lifespan of ACS800 components Electrolytic capacitors DC-link 9 years AINT + flatcables 9 years All rights reserved. - 5 - The typical aging phenomena of electrolytic capacitors are the decrease of capacitance and the increase of ESR. Note that some ACS800 drives have film type capacitors in dc-link. They don t have similar aging phenomena to electrolytic capacitors. In the case of dc-link capacitors the aging causes higher ripples on dc-link voltage and poorer response for rapid load torque changes. The change interval for the dc-link capacitors is nine years. In AINT boards the aging of electrolytic capacitors causes ripple on signals. The change interval for AINT board and its flatcables is nine years.

Aging components on ACS800 Electrolytic capacitors ESR Equivalent Serial Resistance (m) ESR contacts polarization leakage currents All rights reserved. - 6 - Equivalent serial resistance is the ohmic part of the equivalent series circuit of an electrolytic capacitor. It represents the losses associated with a capacitor due to metallic contacts, polarization, leakage currents, and so on; It is expressed in milliohms (mω).

Aging components on ACS800 Cooling air filters Door filters Module filters Annually (at least) replace (IP54) check (IP21...IP42) All rights reserved. - 7 - The drive may have cooling air filters attached on the cabinet door and some modules, for instance the R8i, may be equipped with an internal cooling air filter. Cooling air filters are recommended to be changed annually in the case of IP54 or higher IP classes. In the case of IP21 to IP42 mechanics, the filters must be checked at least annually.

ACS800 Preventive maintenance kits ACS800 Preventive maintenance kits All rights reserved. - 8-12 months warranty Reasonably priced reduces risk of incompatible spare parts ABB verified components Preventive maintenance kits are genuine service parts according exactly to the maintenance schedule, with a 12 months warranty. Kits are reasonably priced as a set compared to the price of individual spare parts. Using the preventive maintenance kits reduces the risk of incompatible spare parts. Delivery time for the kits is four weeks. Return old boards to the ABB Logistic Center. They will be used as exchange spare parts after repair or update and testing. Components on the open market may have similarities with those used on preventive maintenance kits and original drives. Replacing original components with components that are not verified by ABB has a high risk of damaging the drive. The Reason is that open market components have looser tolerances than those delivered by ABB. The exact contents of the Preventive maintenance kit can be found in the Kit Includes view in Parts OnLine.

ACS800 Preventive maintenance kits Assembly SAFETY! ESD requirements Mark connections Handle fiber optics carefully All rights reserved. - 9 - All hardware maintenance actions must be done without any voltage. Before starting the component changing, the safe level of voltages must be ensured by measuring. Check the safety instructions from the hardware and the user s manual. Use ESD protection and handle the new and old components according to ESD requirements. If the wiring connection markings are not clear, mark them to ensure the correct connections when re-installing the components. Handle fibre optics carefully. When disconnecting, pull from the connector, do not disconnect it (fibre optics) from the fibre itself.

ACS800 Preventive maintenance kits Assembly Tools Screwdriver with philips and torx heads Socket wrench tool kit Torque wrench Torque screwdriver All rights reserved. - 10 - LOTUS NOTES In-House Maintenance Manuals (IHMM) Direct links: IHMM for Legacy Drives and IHMM for Active Drives You can also find IHMM in the Lotus Notes Database Catalog. Links open in a new window. Possible requirements: Adobe Acrobat Reader, Lotus Notes, ABB network connection. Always use the correct tools and tightening torque. See individual assembly instructions for the preventive maintenance kits and maintenance instructions in the ACS800 In-House Maintenance manuals support section.

ACS800 Preventive maintenance kits ACS800 cooling fan replacement Hardware manual Clean heatsinks Check the airflow direction All rights reserved. - 11 - You can find the instructions for the exchange of the cooling fan in the drive specific hardware manuals. Before installing the new fan, clean the heatsinks with dry and clean compressed air. Point the airflow only to the backside of the heatsink. Due to the risk of ESD it must not be pointed to electronics, e.g. boards or IGBT modules. Ensure the operation of the fan and the correct airflow direction when making the measurements and other checkings for the unit.

ACS800 Preventive maintenance kits ACS800 other components replacement Cooling air filters: hardware manual All rights reserved. - 12 - You can find instructions for the exchange of cooling air filters in the drive specific hardware manuals.

ACS800 Preventive maintenance measurements ACS800 Preventive maintenance measurements All rights reserved. - 13 - Each drive type has its own reporting tool in the Legacy drives section of the In-House Maintenance manual. All preventive maintenance measurements and checkings are listed on each report form. Instructions for the reporting tool can be found in the training module: Preventive maintenance reporting tool.

ACS800 Preventive maintenance measurements Drives and inverter modules report All rights reserved. - 14 - Preventive maintenance report forms for single drives and inverter modules have three main sections.

ACS800 Preventive maintenance measurements Drives and inverter modules report 0. Environment All rights reserved. - 15 - Check the ambient conditions and that they fit the specifications listed on the hardware manuals. Pay attention to ambient temperature, humidity and other conditions. Note that the air conditioning may be switched off during the scheduled stop. Mark any abnormal items in the report, and if needed you can attach a digital photo. Check the corrosion level of the drive visually by using a magnifying glass and a flashlight. Check the fault logger contents, save the logger to a separate file with DriveWindow2 or mark them in the report. Check the availability of the documentation, manuals, application drawings, etc. Check the spare parts availability, compatibility and storage conditions. Note that annual re-freshing is recommended for individual electrolytic capacitors for dc-link and spare modules. Annual re-freshing ensures the spare units usability without re-freshing when repairing the drive. See the ACS800 Capacitor Reforming Guide in the ACS800 In-House Maintenance manual (section General manuals part Application & Installation & User s guides).

ACS800 Preventive maintenance measurements Drives and inverter modules report 1. Maintenance with no voltage applied All rights reserved. - 16 - In the case of light dust, clean the units with an ESD vacuum cleaner. Use an ESD approved brush to remove the dust and wear personal ESD protection. Note that in case of very dusty units or if the dust contains conductive particles, oil or any other particles that stick to the surfaces, the cleaning should be done in a certified repair center. In that case, the drive can be cleaned thoroughly and tested reliably before delivered back to the customer. Check the condition of electrical connections on the drive. Make a pull test for the wire connections and check the busbar connections with a torque wrench. Search for any loose connections on the busbars, terminals, and so on. Check the mechanical assembly of fuses and their compatibility. When visually checking the fibre optics, dc-link capacitors, printed circuit boards and IGBT-modules, pay attention to any marks of mechanical damage or other abnormalities. Check that the cooling air filters, if not changed, are clean. Check the mechanical conditions of application related to optional relays, contactors, and so on. Measure the insulation resistance of the motor cable and the motor. Disconnect the motor cable from the inverter output before the measurement.

!"" #$%&''$

ACS800 Preventive maintenance measurements Drives and inverter modules report 2. Maintenance with voltage applied All rights reserved. - 17 - Check the cooling fans operation. Make a backup copy of the drive software. Make an I/O test. Note that for safety reasons drives signals to other systems must be eliminated and motor output disconnected. If the drive is equipped with current transducers they can be checked by following the instructions that are in ACS800 In-House Maintenance manuals Support section. Mark down the reading of the Service hour meter, i.e. operation hour counter. Check the dc link. Compare the actual dc link voltage to the voltage in drives signals. Pay attention to safety! Voltage slicing is measured only when the maintenance is made in a certified repair center. Check the pulse encoder, if there is one. Check the mechanical conditions of the tacho, cabling and the coupling. Check the pulses with an oscilloscope when running the drive in scalar mode. The pulses should be square wave. When making a test run, check the motors direction of rotation, test that the drive follows upper level commands. If possible, run the drive on maximum speed and load. Check the emergency stop function. See earlier safety presentations for emergency stop function details. Note that in the case of smaller ACS800 single drives the emergency stop function is normally done by switching off the supplying voltage of the drive and that the drive has no individual relays for emergency stop.

& ()&*(!) + &$ &$, (! &$, (!!"" #$%&''$

ACS800 Preventive maintenance measurements Supply modules All rights reserved. - 18 - The operations mentioned on the diode and thyristor supply modules report form have similar actions to those mentioned earlier on the drives and inverter modules report description.

Additional information (1/2) All rights reserved. - 19 - Links to ACS800 hardware manuals in ABB Library: ACS800-01/U1 Hardware Manual ACS800-02/U2 Hardware Manual ACS800-04/04M/U4 Hardware Manual ACS800-04 Drive Modules Hardware Manual, (0.55 to 132 kw) ACS800-11/U11 Hardware Manual (5.5 to 110 kw) ACS800-07 (45 to 560 kw) Hardware Manual ACS800-07 (500 to 2800 kw) Hardware Manual ACS800-17 Drives (75 to 1120 kw), Hardware manual ACS800-17 Drives (55 to 2500 kw / 75 to 2800 HP), Hardware Manual ACS800-31/U31 Hardware Manual ACS800-37 Drives (55 to 2700 kw / 75 to 3000 HP), Hardware manual ACS800-104 Inverter Modules, Hardware Manual ACS800-107 (1.5 to 5340 kw) Cabinet-built Inverter Units Hardware Manual ACS800-607 Brake Units Hardware Manual ACS800-67 Wind Turbine Drives for Asynchronous Slip Ring Generators Hardware Manual ACS800-07LC Drives Hardware Manual Here are some links to related information. Some of the links are not available in the ABB Library, those documents can be found in the ACS800 In-House Maintenance manual. Check for the latest revision by using the document number search.

Additional information (2/2) Links to ACS800 hardware manuals in ABB Library: ACS800-204 IGBT Supply Modules Hardware Manual ACS800-207 Cabinet-installed IGBT Supply Unit Hardware Manual ACS800-404 Thyristor Supply Modules User's Manual User's Manual: ACS800-407 and ACS800-807 Cabinet-installed Thyristor Supply Units (TSU) (639 to 5991 kw) ACS800-307 and ACS800-507 Cabinet-installed Diode Supply Unit User's manual Diode Supply Modules ACS800-304 and ACS800-704 User's manual ACA 635 IGBT Supply Sections, ACS 800-17 Line-Side Converter User's manual All rights reserved. - 20 - Here are some links to related information. Some of the links are not available in the ABB Library, those documents can be found in the ACS800 In-House Maintenance manual. Check for the latest revision by using the document number search.

Thank you for your attention. You may now go ahead and move on to the next unit.