Boston Gear Ratiotrol

Similar documents
SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Boston Gear Ratiotrol

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

Boston Gear Ratiotrol

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

Boston Gear Ratiotrol

Boston Gear Ratiotrol DC Motor Speed Control

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

TABLE OF CONTENTS SPECIFICATION CHART...8 RATIOPAX DCX/DCXplus BETA II BETAplus VEplus

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Boston Gear RB Series

Fincor Series 2230 MKII/2240

CONTROL FEATURES AVAILABLE OPTIONS

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Boston Gear Ratiotrol

SAFTRONICS DF8 PLUS SERIES

MaxPak Plus Analog DC V S Drive

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

17429X.00 SERIES MODELS:

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Installation & Operation Manual

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Filtered PWM Speed Control for Permanent Magnet DC Motors

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

AC & DC Adjustable Speed Controls and Motors. MTY (81) MEX (55) QRO (442)

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

BC141, BC142, BC142-5 & BC142-6 DC Control

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

Installation and Operation Manual. *See page 6 for CE Information

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

KBMD-240D MULTI-DRIVE

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

PowerOhm Installation Manual for BM R Series Braking Modules

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

DC3N Non-Regenerative DC Drives

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

5001TCP SPEED CONTROLLER

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

PowerOhm Installation Manual for LG ATV Series Braking Modules

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

Installation and Operating Manual

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

CABINET REEL OPERATING INSTRUCTIONS

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

DC Variable Speed Drive Panel

5001TCP SPEED CONTROLLER

USER S MANUAL

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Snap-Trol 183 Nema 1 Series

KBIC SCR DC Motor Speed Controls

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

CABINET REEL OPERATING INSTRUCTIONS

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

KBAC SERIES Adjustable Frequency Drives for 3-Phase AC Motors NEMA-4X / IP-65

XENON POWER SUPPLY 4000 Watt Gladiator IV

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

MOTORTRONICS Solid State AC Motor Control

PowerOhm Installation Manual for BM R Series Braking Modules

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

THE MODEL D1025 MKII BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-276

WARRANTY INFORMATION...

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Installation Sheet January, 2016 Supersedes February, 2013

Transcription:

Boston Gear Ratiotrol DC Motor Speed Control P--BG Installation and Operation Beta ll Series Single Phase /- HP An Altra Industrial Motion Company

Contents Warnings............................. I II III General Information Introduction......................... General Description.................. Motor Selection...................... Installation Installation Guidelines................. Installing The Controller............... Initial Startup....................... Operation Power /Off...................... Run.............................. Stop.............................. Speed Control...................... Jog.............................. Reverse........................... Inoperative Motor................... IV Maintenance and Repair General........................... Adjustment Instructions.............. Troubleshooting..................... V Parts List......................... VI Ratings and Specifications Ratings........................... Operating Conditions................ Performance Characteristics.......... Adjustments....................... Specifications...................... VII Drawings......................... Index................................ Warranty............................. List of Tables Beta II Model Matrix.................. Jumper J Position................... Dip Switch (SW).................... Initial Potentiometer Settings.......... Dynamic Braking Characteristics....... Troubleshooting..................... Parts List, BETA II Controllers.......... Typical Application Data.............. Operating Voltages and Signals........ Controller Weights................... Speed Regulation Characteristics...... Shunt Data.................... Tachometer Feedback Voltage Selection. List of Figures Controller Mounting Configurations...... Controller Mounting Dimensions........ Logic Connection Diagram, Run-Stop-Jog Switch............................ Logic Connection Diagram, Forward-Reverse Switch and Run-Stop-Jog Switch...... Logic Connection Diagram, Run-Stop Pushbuttons and Run-Jog Switch...... Logic Connection Diagram, Optional Armature Contactor Reversing Using Switches.... Logic Connection Diagram, with Unidirectional Armature Contactor using Run-Stop-Jog Switch................ Boston Gear BETA ll Series P-BG

Logic Connection Diagram, with Unidirectional Armature Contactor Using Run- Stop Pushbuttons & Run-Jog Switch.... Logic Connection Diagram, Optional Armature Contactor Reversing Using Pushbuttons and Run-Jog Switch...... Logic Connection Diagram, Line Starting with Motor Speed Potentiometer........... Signal Connection Diagram, Motor Speed Potentiometer...................... Signal Connection Diagram, Tachometer Feedback......................... Signal Connection Diagram, Current (Torque) Reference Potentiometer............. Signal Connection Diagram, Line Starting without a Motor Speed Potentiometer... Signal Connection Diagram, -ma Interface.......................... Signal Connection Diagram, -ma Transducer with Auto/Manual Switch.... Signal Connection Diagram, Transducer with External Burden Resistor............. Signal Connection, - VDC External Speed Reference................... Functional Schematic, BETA ll Controller. Beta ll Control Board, /- HP........ The Following Safety Precautions Must Be Strictly Adhered To At All Times.. You as the owner or operator of BOSTON GEAR equipment have the responsibility to have the users of this equipment trained in its operation and warned of any potential hazards of serious injury.. The drive equipment should be installed, operated, adjusted, and serviced only by qualified personnel familiar with the construction and operation of the equipment and the hazards involved including those described below. Failure to observe this precaution can result in personal injury, loss of life, and property damage.. The National Electrical Code requires that an AC line fused disconnect or circuit breaker be provided in the AC input power lines to the controller. This disconnect must be located within sight of the controller. Do not operate the controller until this code requirement has been met.. The drive equipment is at AC line voltage potential whenever AC power is connected to the drive equipment. Contact with an electrical conductor inside the drive equipment or AC line disconnect can cause electric shock resulting in personal injury or loss of life.. Be sure all AC power is disconnected from the drive equipment before touching any component, wiring, terminal, or electrical connection in the drive equipment.. Always wear safety glasses when working on the drive equipment.. Do not remove or insert circuit boards, wires, or cables while AC power is applied to the drive equipment. Failure to observe this precaution can cause drive damage, personal injury, or loss of life. P--BG Boston Gear BETA ll Series

. All drive equipment enclosures, motor frames, and remote operator stations must be connected to an unbroken common ground conductor. An unbroken grounding conductor must be run from the common ground conductor to a grounding electrode buried in the earth or attached to a plant ground. Refer to the National Electrical Code and local codes for grounding requirements.. The atmosphere surrounding the drive equipment must be free of combustive vapors, chemical fumes, oil vapor, and electrically conductive or corrosive materials.. Solid state devices in the controller can be destroyed or damaged by static electricity. Therefore, personnel working near these static-sensitive devices must be appropriately grounded. Section I. General Information Introduction General Description These controllers statically convert AC line power to regulated DC for adjustable-speed armature control of shunt-wound and permanent-magnet motors. These controllers comply with applicable standards established by the National Electrical Code and NEMA for motor and industrial control equipment. The controllers are Underwriters Laboratories Listed (File No. E). Motor Selection These controllers control the operation of general purpose DC motors designed for use with solid-state rectified power supplies. The motor may be shunt-wound, stabilized shunt-wound, or permanent magnet. For maximum efficiency, the motor should be rated for operation from a NEMA Code K power supply. Boston Gear BETA ll Series P-BG

Table. BETA II Model Matrix Item Code RBA Cat. No. Line Voltage HP Range Construction Function VAC VAC Angle Bracket Chassis Open Chassis Enclosed Run/ Stop Arm. Cont. Run/Stop W/D.B. Arm. Switch Rev. Arm. Cont. Rev. W/D.B. Operator s Controls Local (Integral) Remote Wiring Diagram Figure # X X, RBAC X X X, RBAU X X X, RBACU X X X, RBAM X X X, RBACM X X X, RBAB X X X, RBAB-WD X* X X, RBAUB X X X, RBAUB-WD X* X X, /- /- RBAMB X X X, RBAMB-WD X* X X, RBAS X X X RBAS-WD X* X RBAR X X X RBAR-WD X* X X RBAUS X X X RBAUS-WD X* X X RBAMR X X X RBAMR-WD X* X X RBA X X X, RBAU /- /- X X X, RBAM X X X, * Washdown Duty Units are reconnectable Section II - Installation Before starting the installation, read this section thoroughly. In addition, a thorough review of the Ratings and Specifications (Section VI) is recommended. The following installation guidelines should be kept in mind when installing the controller. Installation Guidelines. Controller Mounting The controller may be mounted either vertically or horizontally. However, never mount the controller upside down, immediately beside or above heat generating equipment, or directly below water or steam pipes. The controller must be mounted in a location free of vibration. P--BG Boston Gear BETA ll Series

Multiple controllers may be mounted side by side, as close to each other as the mounting feet will allow. The minimum clearance at the top and bottom of the controller may be as narrow as the conduit fittings allow.. Atmosphere The atmosphere surrounding the controller must be free of combustible vapors, chemical fumes, oil vapor, and electrically conductive or corrosive materials. The air surrounding an enclosed controller must not exceed degrees C ( degrees F), and the air surrounding an open-chassis controller must not exceed degrees C ( degrees F). Minimum air temperature is degree C ( degrees F) for enclosed and open-chassis controllers.. Controller Construction The controller base is made of die-cast aluminum with a powdered epoxy finish, and the cover is made of a die-cast aluminum alloy. The controller enclosure is totally enclosed, nonventilated, and complies with NEMA type and standards. There is an oil resistant synthetic rubber gasket between the cover and base. Those models with integral operator controls include flexible boots to seal the switches, and a seal for the MOTOR SPEED potentiometer.. Line Supply The controller should not be connected to a line supply capable of supplying more than, amperes short-circuit current. Short-circuit current can be limited by using an input supply transformer of KVA or less, or by using correctly sized current limiting fuses in the supply line ahead of the controller. Do not use a transformer with less than the minimum transformer KVA listed in Table, page. If rated line voltage is not available, a line transformer will be required. If the line supply comes directly from a transformer, place a circuit breaker or disconnect switch between the transformer secondary and the controller. If power is switched in the transformer primary, transients may be generated which can damage the controller. See Table (page ) for minimum transformer KVA. Do not use power factor correction capacitors on the supply line to the controller. A -joule metal oxide varistor (MOV) is connected across the controller terminals. If higher energy transients are present on the line supply, additional transient suppression will be required to limit transients to % of peak line voltage. When a VAC line supply is used, connect the white (common) wire to Terminal L and connect the remaining (hot) wire to Terminal L.. Isolation Transformer While not required, an isolation transformer can provide the following advantages: a. Reduce the risk of personal injury if high voltage drive circuits are accidentally touched. b. Provide a barrier to externally generated AC supply transients. This can prevent controller damage from abnormal line occurrences. c. Reduce the potential for damaging current if the motor armature, motor field, or motor wiring become grounded.. Grounding Connect the green or bare (ground) wire of the line supply to the ground screw located near the top conduit entry hole in the controller base. Then ground the controller base by connecting the ground screw to the earth ground. The motor frame and operator control stations must also be grounded. Personal injury or loss of life may occur if the controller, motor, and operator stations are not properly grounded.. Wiring Practices The power wiring must be sized to comply with the National Electrical Code, CSA, or local codes. Refer to the controller data label for line and motor current ratings. Do not use solid wire. Signal wiring refers to wiring for potentiometers, tachometer generators, and transducers. Control wiring refers to wiring for operator controls, e.g., switches and pushbuttons. Signal and control wiring may be run in Boston Gear BETA ll Series P-BG

a common conduit, but not in the same conduit as the power wiring. In an enclosure, signal and control wiring must be kept separated from power wiring and only cross at a degree angle. If shielded wire (such a Alpha - two conductor, - three conductor, - four conductor) is used for the signal and control wiring, connect the shields to chassis ground (ground screw on the controller base) and tape the opposite ends of the shields. Two /- NPT threaded holes are provided for conduit entry, one each in the top and bottom of the controller. Installing the Controller. Remove the controller front cover (if used) by removing the four cover screws.. Check components in the controller for shipping damage. Report shipping damage to the carrier.. Check the controller and motor data labels to be sure the units are electrically compatible.. Be sure the controller has been calibrated correctly for the motor being used. Calibration is performed by changing the position of a Jumper (J) on the controller control board to comply with Table. To change the position of Jumper J, pull the jumper from the control board and then push it onto the appropriate two pins on the board. For the location of J, see Figure (page ). Jumper Position % % % % % Table. Jumper J Position Motor Armature Current Rating (Amperes) HP Maximum HP Maximum. Select the position closest to the motor nameplate armature current rating.. Check the positions of Jumpers J, J and J on the control board. For the locations of J, J and J, see Figure, page. For a VAC line supply and a V armature motor, Jumper J must be in the V position, and Jumpers J and J must be in the V position. For a VAC line supply and a V armature motor, J must be in the V position, and J and J must be in the V position. To change the position of J, J, or J pull the jumper from the control board and then push it onto the appropriate pins on the board. Note: If an armature contactor card option is to be installed in the controller, do not off-set the five-position plug (supplied with the card) at Connector J on the control board. Do not confuse Connector J with Jumper J. Refer to the Instruction Sheet supplied with the option for connection instructions.. The controllers may be surface mounted or panel mounted as shown in Figure, page. Mount the controller. Mounting dimensions are shown in Figure, page.. Conduit entry is made by punching out the knockout at the top or bottom of the controller base. To prevent component damage from knockout fragments, apply masking tape to the inside of the knockout before punching.. Connect the power wiring to Terminals L, L, A (+), A (-), F+ and F-. Be sure to observe Installation Guidelines and on page. If half-wave shunt field voltage is desired, connect one of the motor shunt field leads to Terminal F/ (see Table on page ). Note: Low inductance motors require a full-wave field to prevent current instability.. If the controller contains any options that require external wiring, follow the wiring instructions in the instruction sheet supplied with the option. P--BG Boston Gear BETA ll Series

. If remote operator control wiring and/or signal wiring is required, connect the controller as shown in the appropriate connection diagram (Figures through ). Figures through show operator control connections and Figures through show signal connections.. The controller can be programmed for various applications by throwing switches on SW.. Install the controller cover, if used. Table. Dip Switch (SW) Factory Default Setting Is All Switches ON Switch Position ON OFF ON OFF ON OFF ON OFF ON OFF Low Voltage (Vdc - Vdc) tachometer scaling. High Voltage (Vdc - Vdc) tachometer scaling. Selects internal burden resistor for -ma input. Selects to V speed reference input or external burden resistor (i.e. to ma). Selects internal current (torque) limit pot. Selects use of an external current (torque) limit pot. Selects Min Speed pot. adjustment. Selects Offset adjustment (for -ma input) with Min Speed pot. Selects anti-restart mode. Prevents controller from restarting automatically after an AC line power interruption. Disables anti-restart mode. Used for line starting applications (jumper TB: to TB: to enable drive. Boston Gear BETA ll Series P-BG

Figure. Base Mounted Controller Mounting Configurations. Ref Maximum Depth... Typ Ground. Ref. Ref... ÿ. PL. Ref. Ref... Ref.. ÿ. PL Figure. Controller Mounting Dimensions P--BG Boston Gear BETA ll Series

TB A TB L F S- Jog /VAC L E Run E Armature / VDC J A V V F+ Speed Adj K V V S- Jog Run +V TB -V K ÿ K ÿ Enable J Current Scaling S % % % % % J Default Settings J F/ F- V V /V / Wave /V Full Wave Figure. Logic Connection Diagram, Run-Stop-Jog Switch TB A Fwd S- /V TB L L F E S- Jog Run E Rev M Armature /VDC J A S- V V F+ M S- S- Fwd Jog Rev Speed Adj K V V Run +V TB +V Kÿ Kÿ Enable J % % % % % Current Scaling S J Default Settings F/ F- J V V /V / Wave /V Full Wave Figure. Logic Connection Diagram, Forward-Reverse Switch and Run-Stop-Jog Switch Boston Gear BETA ll Series P-BG

TB L F TB A /VAC L J E E A Armature / VDC Figure. Logic Connection Diagram, Run-Stop Pushbuttons and Run-Jog Switch Stop Run Run V V V V Jog TB +V Kÿ Kÿ Enable J % % % % % Current Scaling S J F+ F/ F- J V V /V / Wave /V Full Wave Speed Adj K +V Default Settings Figure. Logic Connection Diagram, Optional Armature Contactor Reversing Using Switches TB L F / VAC L Speed Adj K +V V V V V J TB KO J J % % % % % Current Scaling E E J V V S Default Settings TB A A F+ Reversing Board K K K M DB DB K K DB K M F/ F- /V / Wave TB K K TB COM +V S- Jog S Rev Fwd Momentary S- Run Jog Run Armature / VDC /V Full Wave Figure. Logic Connection Diagram, with Unidirectional Armature Contactor Using Run-Stop-Jog Switch, /- HP /VAC Speed Adj K +V TB L V V V V TB L F J Kÿ J Current Scaling J % % % % % E J S E V V Default Settings S-Jog S- Run Jog Run TB A A F+ F/ F- Reversing Board K M K DB DB DB K M TB TB K COM +V /V / Wave Armature /VDC /V Full Wave P--BG Boston Gear BETA ll Series

Figure. Logic Connection Diagram, with Unidirectional Armature Contactor Using Run-Stop Pushbuttons & Run-Jog Switch /- HP TB L /VAC L Speed +V Adj K J V V V V TB F Kÿ J J Current Scaling % % % % % E J V V S E Default Setting Stop TB A A F+ F/ F- Fwd Jog Run Reversing Board K M K DB DB DB K M TB TB /V / Wave K COM +V Armature /VDC /V Full Wave Figure. Logic Connection Diagram, Optional Armature Contactor Reversing Using Pushbuttons and Run-Jog Switch TB L /VAC L J V V V V TB F Kÿ J +V J Speed % % Adj % % K Current Scaling % E J V V S E Default Settings Stop TB A A F+ F/ F- Rev Fwd Jog Run Reversing Board K M K DB DB DB M K K /V / Wave TB K K TB COM +V Armature /VDC /V Full Wave TB A TB L F /VAC L E E Armature /VDC Figure. Logic Connection Diagram, Line Starting with Motor Speed Potentiometer Speed Adj K V V V V J TB +V Kÿ +V Kÿ Enable J % % % % % Current Scaling S A F+ F/ F- J J V V Line Starting /V / Wave /V Full Wave Boston Gear BETA ll Series P-BG

Speed Adj K Minimum resistance = K Maximum resistance = K TB * Min Spd * Shielded wire recommended for long runs or noisy environment. S S- Default Settings +V V Spd Ref Figure. Signal Connection Diagram, Motor Speed Potentiometer DC Tach V/K Polarity Insensitive TB e Piece Jumper K S- K IR Comp/Tach Max Spd K Arm J JJ Tach Note: In tach feedback mode and ends of pot are reversed (as shown) from IR Comp function. J NC + Cur Signal S Tach Arm Absolute Value SW: Default = -VDC Tach Shown Off = -VDC J NC -Arm Fdbk Fdbk K K Figure. Signal Connection Diagram, Tachometer Feedback J Tach Arm S Cur Ref K Spd Ref K TB +V = Internal torque limit pot Off = External torque limit pot S- Cur Limit K External Torque Ref Cur Ref Min Spd K S- Offset Input (-) Figure. Signal Connection Diagram, Current (Torque) Reference Potentiometer P--BG Boston Gear BETA ll Series

TB +V Enable S Line Start +V Speed Input Figure. Signal Connection Diagram, Line Starting without a Motor Speed Potentiometer XDCR Pwr -ma XDCR + - TB Min Spd Offset Pot %=Normal S +V S- S- Offset Input Input Offset Spd Ref -V ohm Figure. Signal Connection Diagram, - ma Interface XDCR Pwr to ma XDCR + - Man Spd K TB Man Auto Min Spd Offset Pot %= Normal S +V V Speed Ref S- Offset Input Input Offset S- Spd Ref -V ohm Figure. Signal Connection Diagram, - ma Transducer with Auto/Manual Switch Boston Gear BETA ll Series P-BG

XDCR Pwr XDCR + - Input Current -ma -ma -ma -ma R= V Max External Burden R ohm /W ohm /W ohm /W K /W * * TB Min Spd Offset Pot %=Normal *Use Internal ohm Resistor S +V S- Input Offset Ext Burden Offset Input Spd Ref -V S- * ohm Figure. Signal Connection Diagram, Transducer with External Burden Resistor TB Voltage Source -V + - S (No specific set-up) V Speed Ref Z = K Int Figure. Signal Connection, - VDC External Speed Reference P--BG Boston Gear BETA ll Series

Initial Startup. Open the controller cover (if used) by removing the four cover screws.. Be familiar with all options installed in the controller by reviewing the instruction sheets supplied with the options.. Be sure all wiring is correct and all wiring terminations are tightened securely.. Be sure the controller is calibrated correctly. See steps and under Installing The Controller on page.. Be sure the AC line voltage to the controller agrees with the controller data label. Table. Initial Potentiometer Settings Potentiometer Setting Description Accel / Turn Clockwise Seconds Cur Lmt fully Clockwise (%) % Load Decel / Turn Clockwise Seconds IR/Tach Fully Counterclockwise (%) % Boost Max Spd / Turn Clockwise % Speed Min Spd Fully Counterclockwise (%) % Speed. The potentiometers in the controller are factory adjusted as shown in Table. These settings will provide satisfactory operation for most applications. If different settings are required, refer to Adjustment Instructions starting on page.. If the controller has a cover, place it on the controller and secure it with the four cover screws.. Turn-on the AC supply to the controller.. Check motor rotation, as follows: a. If a MOTOR SPEED potentiometer is used, turn it fully counterclockwise. If an external signal is used for the speed reference, set it at minimum. b. If a RUN-STOP-JOG switch is used, place it in RUN position. Otherwise, initiate a RUN command. c. Turn the MOTOR SPEED potentiometer clockwise or increase the speed reference signal, as applicable. To stop the motor, place the switch in STOP position or initiate a STOP command, as applicable. If the motor rotates in the wrong direction, turn off the AC power to the controller, and then interchange the motor armature leads at the motor connection box or at the controller terminal board.. Refer to Section III, Operation for operating instructions. Section III - Operation Power /Off To energize the drive, turn-on the AC supply voltage to the controller. When this occurs, the motor shunt field energizes with rated field voltage, and potentially hazardous voltage is present at the motor armature terminals. These voltages can cause electric shock resulting in personal injury or loss of life. If the AC supply is interrupted and the controller is not set up for line starting, the motor will not restart when the AC supply is restored until the controller is reset by initiating a Stop command and then a Start command. If the controller is set up for line starting and the AC supply is interrupted, the motor will restart when the AC supply is restored, provided the external AC line contactor is pulled in. Run If a RUN-STOP-JOG switch is used, place the switch in RUN position. Otherwise, initiate a RUN command. A RUN command will accelerate the motor to the setting of the MOTOR SPEED potentiometer or external speed reference signal, as applicable. The rate of acceleration is preset by the ACCEL potentiometer on the controller control board. Stop If a RUN-STOP-JOG switch is used, place the switch in STOP position. Otherwise, initiate a STOP command. A STOP command will stop the motor at a rate proportional to the stopping rate of the motor load. Boston Gear BETA ll Series P-BG

If the controller has dynamic braking, the motor stopping time will be reduced. Dynamic braking provides exponential rate braking of the motor armature, which occurs when the circuit is opened between the controller and the motor armature, and one or more resistors are connected across the motor armature. The dynamic braking resistors provide initial braking torque and stops per minute as shown in Table. An antiplug feature is included with Armature Contactor Reversing With Dynamic Braking. This feature prevents restarting the motor before the motor has braked to a stop. Speed Control Motor speed is directly proportional to the setting of the MOTOR SPEED potentiometer or the magnitude of an external speed reference signal, as applicable. This potentiometer or the speed reference signal may be adjusted while the motor is running or may be preset before the motor is started. The rates of acceleration and deceleration are preset by the ACCEL and DECEL potentiometers, respectively, located on the controller control board. Maximum speed and minimum speed are preset by the MAX SPD and MIN SPD potentiometers, respectively, located on the control board. Jog If a RUN-STOP-JOG switch is used, place the switch in JOG position. Otherwise initiate a JOG command. Jog is momentary, causing motor rotation only while the switch is held in JOG position or while a JOG command is active. Release the switch to stop the motor. Normally, jog speed is directly proportional to the setting of the MOTOR SPEED potentiometer. If a separate JOG SPEED potentiometer is used, jog speed will be directly proportional to the setting of the JOG SPEED potentiometer. Reverse To reverse motor rotation on controllers with reversing capabilities, initiate a STOP function and then initiate a reversing command. The motor will then accelerate to the setting of the MOTOR SPEED potentiometer or external speed reference signal, as applicable. Forward and reverse speed ranges are identical. If a FWD-REV switch is used, it must have a center position interlock, which requires a momentary relaxation of pressure before the opposite position can be engaged. The center position causes a STOP command and allows time for the motor to stop before a REVERSE command is initiated. If a REVERSE command is initiated while the motor is rotating, motor and controller damage may occur. Table. Dynamic Braking Characteristics Component Model Rated Voltage Rated Horsepower / / / / / -/ Braking Torque (%) Stops Per Minute RBAM RBAM RBAM RBAM V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A V N/A N/A N/A. High Inertia Loads may extend braking time and cause the wattage rating of the dynamic braking resistors to be exceeded. P--BG Boston Gear BETA ll Series

If Armature Contactor Reversing With Dynamic Braking is installed, an antiplug feature prevents reversing the motor before the motor has stopped. Inoperative Motor If the motor stops and/or won t start, turn off the AC supply to the controller, remove the controller cover (if used), and check the AC line fuse on the controller control board. For the location of the fuse, see Figure, page. If the fuse is blown, refer to the Troubleshooting Table (Table ). Section IV - Maintenance and Repair General. Keep the controller dry and free of dust, dirt, and debris. No parts require periodic replacement.. Periodically turn off the AC line supply to the controller and check wire terminations to be sure they are tight.. Visually check components for damage due to overheating or breakage. All damaged and/or faulty components must be replaced for satisfactory operation.. Maintain the motor according to maintenance instructions supplied by the motor manufacturer. Adjustment Instructions Acceleration. Set the MOTOR SPEED potentiometer at % or the external speed reference signal at maximum, as applicable.. Initiate a RUN command and observe the time required for the motor to reach maximum speed.. Adjust the ACCEL potentiometer for the desired rate. Full counter clockwise rotation is the fastest acceleration (. second), and full clockwise rotation is the slowest acceleration ( seconds). Deceleration. With the motor running at maximum speed, quickly reset the MOTOR SPEED potentiometer to zero, or quickly decrease the speed reference signal to minimum, as applicable, and observe the time required for the motor to reach minimum speed.. Adjust the DECEL potentiometer for the desired rate. Full counter clockwise rotation is the fastest deceleration (. second), and full clockwise rotation is the slowest deceleration ( seconds). IR Compensation IR compensation is used only for armature feedback. The IR/COMP potentiometer is factory set at zero (full counterclockwise rotation) for satisfactory operation with most motors. If improved speed regulation is desired, readjust IR compensation as follows:. If the motor is shunt-wound, run it at rated base speed. If the motor is a permanentmagnet type, run it at about / speed.. Turn the IR/COMP potentiometer clockwise slowly until motor speed becomes unstable. Then turn the potentiometer counterclockwise until motor speed stabilizes. Maximum Speed The MAX SPD potentiometer is factory set to provide VDC armature voltage with a VAC line, or VDC armature voltage with a VAC line. To readjust maximum speed, run the motor at maximum speed and adjust the MAX SPD potentiometer for the desired maximum speed. Note: If the MAX SPD potentiometer is turned too far counterclockwise, speed instability may occur. Minimum Speed. Turn the MIN SPD potentiometer fully counterclockwise (%) for zero speed. Boston Gear BETA ll Series P-BG

. Set the MOTOR SPEED potentiometer at %.. Initiate a RUN command and adjust the MIN SPD potentiometer for the desired minimum speed (adjustable from to % of motor base speed). Current Limit. Turn the CUR LMT potentiometer fully clockwise (%) to limit motor armature current to % of rated.. Turn the CUR LMT potentiometer counterclockwise to reduce maximum motor armature current. Note: An external K ohm Current (Torque) Limit potentiometer can be used as shown in Figure on page. Dip switch S position must be in the OFF position if an external Current (Torque) Limit potentiometer is desired.. Move the one piece jumper on J, J and J from the ARM position to the TACH position.. Select the tachometer voltage scaling at max speed by dip switch SW: as follows: TACH VOLTS SW: to Vdc ON to Vdc OFF. Adjust the IR/TACH MAX SPEED potentiometer fully clockwise, this will provide minimum speed with tach feedback.. Run the motor with maximum speed reference and start adjusting the IR/TACH MAX SPEED potentiometer counterclockwise until motor speed increases to the desired maximum speed with tach feedback. Note that if the tachometer signal is lost, the drive will automatically revert back to armature feedback.. The GREEN power on LED indicator will change to RED whenever the controller is limiting (or regulating) current to the motor. Tachometer Feedback Setup. Before connecting or configuring tachometer feedback, follow the instructions to install and perform initial startup, then run drive with maximum input speed reference and adjust the MAX SPEED potentiometer (Rb) for the desired maximum motor speed. Note that for best performance, this should be within ±% of the motor nameplate maximum speed or stability problems may occur. P--BG Boston Gear BETA ll Series

Troubleshooting The following table is provided as a guide to common problems that may occur with a DC motor controller and the corrective action that may resolve that problem. Table. Troubleshooting Indication Possible Cause Corrective Action. Motor won t start (See Inoperative Motor Page ). AC line open Operator controls inoperative or connected incorrectly Be sure rated AC line voltage is applied to the controller. Repair accordingly. Open circuit between Connectors E and E. A wire jumper or switch must connect E to E. Controller not reset Line Voltage Selection Jumper J in wrong position Controller not enabled Loss of speed reference signal Controller not adjusted correctly Open shunt field winding or wiring to the motor shunt field, causing loss of torque Motor failure Initiate a STOP command and then a START command. See Step on Page under, Installing The Controller. Be sure + VDC is applied to Terminal TB-. Check for - VDC speed reference signal. Turn the ACCEL and CUR LIM potentiometers fully counterclockwise (%). Check the motor shunt field and associated circuitry for a loose connection or a broken wire. Repair accordingly. Repair or replace the motor.. Controller line fuse blows when AC line power is applied to the controller.. Controller line fuse blows when a START command is initiated. Control board failure Wiring faulty or incorrect Circuit, component, or wiring grounded SCR, SCR, SCR, or SCR shorted Bridge diode Db shorted Varistor RV shorted Shunt field diode D, D, D or D shorted Motor shunt field shorted or grounded Control board failure e or more SCR s or Diode Db shorted Motor shorted or grounded Control board failure causing SCR s to turn-on fully Replace the control board. Check all external wiring terminating in the controller. Correct accordingly. Remove ground fault. Replace shorted SCR s or the control board. Replace shorted diode or the control board. Replace RV or the control board. Replace shorted diode or the control board. Repair or replace the motor. Replace the control board. Replace shorted devices or the control board. Repair or replace the motor. Replace the control board. () Does not apply to permanent-magnet motors. (continued) Boston Gear BETA ll Series P-BG

Troubleshooting Table. Troubleshooting (continued) Indication Possible Cause Corrective Action. Controller line fuse blows while the motor is running. Motor overloaded Loose or corroded connection. Wiring faulty, incorrect, or grounded Motor shorted or grounded e or more SCR s or Diode Db breaking down (shorting intermittently) Control Board Failure causing SCR false firing or misfiring Check shunt field current. Low shunt field current causes excessive armature current. If field current is adequate, check for a mechanical overload. If the unloaded motor shaft does not rotate freely, check motor bearings. Also check for a shorted motor armature. Motor overload can also be caused by incorrect gear ratio. Correct accordingly. Check all terminals, connections, and wiring between the line, controller, and motor. Repair or replace the motor. Replace faulty devices or the control board. Replace the control board.. Minimum speed excessive Minimum speed not adjusted correctly Motor armature grounded Control board failure Maximum speed set too high Turn the MIN SPD potentiometer counterclockwise. Correct ground fault. Replace the control board. Turn the MAX SPD potentiometer counterclockwise.. Maximum speed excessive. Motor won t reach top speed. Controller not calibrated correctly Refer to Steps and on page. Open shunt field winding or wiring to the motor shunt field Motor field demagnetized Low line voltage Motor overloaded Maximum speed set too low Current limit set too low Check the motor shunt field and associated circuitry for a loose connection or a broken wire. Repair accordingly. Replace the motor. Check for rated line voltage, ±%, on the controller line terminals. Check shunt field current. Low shunt field current causes excessive armature current. If field current is adequate, check for a mechanical overload. If the unloaded motor shaft does not rotate freely, check motor bearings. Also check for a shorted motor armature. Motor overload can also be caused by incorrect gear ratio. Correct accordingly. Turn the MAX SPD potentiometer clockwise. Turn the CUR LMT potentiometer clockwise. Current scaling jumper J in wrong position See Step and Table (page ). Motor field demagnetized Control board failure Replace the motor. Replace the control board. () Does not apply to permanent-magnet motors. () Does not apply to shunt-wound motors. (continued) P--BG Boston Gear BETA ll Series

Troubleshooting Table. Troubleshooting (continued) Indication Possible Cause Corrective Action. Unstable speed AC line voltage fluctuating Loose or corroded connection. Wiring faulty, incorrect, or grounded Oscillating load connected to the motor Voltage selection jumpers J, J or J in wrong position IR compensation not adjusted correctly Maximum speed not adjusted correctly Observe line voltage with a voltmeter or oscilloscope. If fluctuations occur, correct condition accordingly. Check all terminals, connections, and wiring between the line, operator controls, controller, and motor. Stabilize the load. Turning the IR/TACH potentiometer counterclockwise may minimize oscillation. See Step on page under Installing The Controller. See the IR Compensation adjustment instructions on page. See the Maximum Speed adjustment instructions on page.. Line and motor armature current excessive. Shunt field current too low. Shunt field current too high Motor faulty Tachometer generator or coupling faulty (if used) Motor overloaded Open shunt field winding or wiring to the motor shunt field Shunt field connected for incorrect voltage Diode D, D, D or D failure Shunt field connected for incorrect voltage Shunt field windings shorted Ventilation insufficient Check motor brushes. Replace if needed. Repair or replace the motor. Repair accordingly. Check shunt field current. Low shunt field current causes excessive armature current. If field current is adequate, check for a mechanical overload. If the unloaded motor shaft does not rotate freely, check motor bearings. Also check for a shorted motor armature. Motor overload can also be caused by incorrect gear ratio. Correct accordingly. Check the motor shunt field and associated circuitry for a loose connection or a broken wire. Repair accordingly. Check motor rating and refer to Table, page. Replace faulty diode or the control board. Check motor rating and refer to Table, page. Measure the shunt field resistance and compare with the motor rating. Repair or replace the motor. Remove dirt, dust, and debris from motor intake and exhaust screens.. Motor thermal guard tripped (if used) Excessive motor load at low speed Line and motor armature current excessive Motor overheating from friction Shorted motor windings or faulty bearings Reduce the load or increase the speed. See Indication. Check for misalignment. Realign the motor. Repair or replace the motor. () Does not apply to permanent-magnet motors. () Does not apply to shunt-wound motors. Boston Gear BETA ll Series P-BG

Section V - Parts List Table. Parts List, Beta II Controllers Part Number Part Rating Model RBA Model RBA Control Board N/A Diode Db a, v N/A a, v N/A Fuse, Line, F A, v (ATM-) SCR, SCR, SCR, SCR A, V N/A A, V N/A Section VI - Ratings and Specifications Ratings. Duty.......................Continuous. Horsepower Range.........../ - HP (See Table, Page ). Line Fuse Interrupting Capacity....................., Amperes. Line Power...V or V, Single-Phase, or Hz. Motor Speed Potentiometer.......................K Ohms, /W. Overload Capacity, Armature Circuit.....................% for Minute. Timed Overload Threshold.........%. Service Factor...................... Table. Typical Application Data Component Ratings Rated Horsepower (HP) / / / / / -/ Rated Kilowatts (kw)......... -Phase AC Input (Full-Load) Line Amps V Unit V Unit...... - - - - - -...... KVA......... DC Output (Full-Load) Motor Armature Amps RBA Motor Model Amps RBA (Maximum) Model Full-Load Torque (lb-ft) with RPM Base Speed Motors Minimum Transformer KVA For Voltage Matching or Isolation V...... - - - V - - -.............. -........................... P--BG Boston Gear BETA ll Series

Ratings (continued) Table. Operating Voltages and Signals Power Source (Single phase) V, or Hz V, or Hz Armature Output VDC Operating Conditions - / - / Speed Reference Signal Magnetic Control Voltage - VDC VDC Table. Controller Weights Controller Model Weight - LBS (KG) RBAC. (.) RBACU, RBACM. (.) RBA, RBA. (.) RBAU, RBAM RBAU, RBAM RBAB, BRAB-WD RBAS, RBAS-WD RBAR, RBAR-WD RBAUB, RBAUB-WD RBAUS, RBAUS-WD RBAMB, RBAMB-WD RBAMR, RBAMR-WD. (.). (.). (.). Altitude, Standard...... Meters ( Feet) Maximum (). Ambient Temperature.................- C ( F - F) (). Relative Humidity.....% Noncondensing () Controller can be derated by % per meters to operate at higher altitudes. () C ( F) maximum in enclosed areas where open-chassis controllers are mounted. Performance Characteristics. Controlled Speed Range................. to Motor Base Speed. Efficiency (Rated Speed/Rated Load)..% a. Controller ly..................% b. Controller with Motor, Typical.......%. Speed Regulation..Regulation percentages are of motor base speed under steady-state conditions. Adjustments. Acceleration, Linear....... - Seconds. Deceleration, Linear....... - Seconds. IR (Load) Compensation.... to % Boost. Jog Speed........... - % of Motor Base Speed. Maximum Speed........% - % of Motor Base Speed. Minimum Speed............ - % of Motor Base Speed. Torque (Current) Limit............ - % of Full-Load Torque. Line Frequency Variation....± Hz of Rated. Line Voltage Variation........± of Rated Regulation Method Standard Voltage Feedback with IR Compensation Table. Speed Regulation Characteristics Load Change (%) Line voltage (±%) Variable Heating (Cold/Normal) Temperature (± C) Speed Range % ±% - % ±% : DC Tach Feedback.% ±%.% ±% : Boston Gear BETA ll Series P-BG

Specifications. AC Line Protection - A, ampere interrupting capacity AC line fuse provides instantaneous protection from peak loads and fault currents. This line fuse is located inside the controller.. Auxiliary Contact - A normally-open Form A relay contact, rated. ampere at VAC and A at VDC, is available for external use. The relay energizes when a RUN command is initiated, and de-energizes when a Normal STOP command is initiated, the overload monitor trips, or the anti-restart circuit is activated.. Supply - A half-wave or full-wave shunt field supply is available as Shown in Table. Table. Shunt Data Controller Motor Shunt Shunt Voltage (VDC) Rating Lead Connections (VAC) Half-Wave Full-Wave F F F/ F- F+ F- F/ F- F+ F- Low inductance motors require a full-wave field to prevent speed instability.. Motor Contactor - Controller model numbers with an M or U in the suffix, e.g., RBAU, RBAM, have a DC magnetic armature contactor which disconnects both motor armature leads from the controller. An antiplug circuit ensures that the contactor does not make or break DC.. Power Conversion - The DC power bridge consists of four SCR s and one freewheeling diode. Each device is rated at least PIV. The controller base forms an integral heat sink with the power devices electrically isolated from the base. a. Line Starting - By placing SW: in the OFF position, the anti-restart feature will be disabled, and the controller may be started and stopped with an external AC line contactor. However, a wire jumper must be connected between TB-- and TB-. If full speed operation is desired, connect another wire jumper between TB- and TB-. b. Tachometer Feedback - To use tachometer feedback with armature feed-back backup, connect the tachometer generator signal to TB- and TB- (polarity insensitive) and select the tachometer generator voltage at maximum speed by using SW: as follows: Table. Tachometer Feedback Voltage Selection Tach Voltage Vdc - Vdc Vdc - Vdc SW: ON OFF c. Torque Regulator - The controller will function as a torque regulator when SW: is OFF. This allows an external potentiometer to set maximum motor torque ( - % of rated).. Voltage Transient Protection - A metal oxide suppressor (varistor) across the AC line is combined with RC snubbers across the power bridge to limit potentially damaging high voltage spikes from the AC power source.. Selectable Capabilities - Switches allow the user to select various modes of operation as follows: P--BG Boston Gear BETA ll Series

/VAC L L TB F ATM- AC E AC S-A E SCR SCR FL= MV HP=.Ω R A TB / VDC /V /V F+ F/ SCR SCR A TB % % Com F- % % % = Power Connection TB = Customer Interface TB = Option Connector J = Space Connector (not on HP Ver) AC AC Line Voltage Selection J V V V V VAC VAC VAC / -V -V +V V +V K +V V J V V M J V M V R Current Reg UD Grn= Arm Isolator K M M + K Max Spd.K Shunt Isolator VAC Current Signal FL-V Red= Current Limit K uf K Max Spd Arm Tach K + UB Arm Arm Backup -V K M K K K + UB K M Accel + K M K K Decel K M Reset Load Monitor S- Open for Line Start Anti Restart J Arm S- K Tach J,, Set By e Piece Jumper J Arm Tach Absolute Value Open for HV Tach K K IR Conp/ Max Spd Tach S- Open For K Ext Burden K Res + K UB +V Offst Input Open For Offset S- Min Spd K Open For Torue Input S- Current Limit K +V Enable Supervisory KO KO Logic Q -MA +V Spd Ref K +V Run Coast Stop - - - - - Section VII - Drawings Connections G & G G Control And Firing Circuit Error Signal Speed Reg UC - + K Ext Accel Cap uf C + + - Figure. Functional Schematic, BETA II Controller Boston Gear BETA ll Series P-BG

Position Dip Switch (All set in closed position) Calibration Pot Deceleration Pot Acceleration Pot Armature-Tach Feedback Position Jumper J, J, J (set on Armature) RB RB Accel Decel J Option Connector J Maximum Speed Pot Minimum Speed Pot Motor Current Jumper J Set @ % /V AC Jumpers J & J (Shown in V Position) /V AC Jumper J (Shown in V Position) AC Line Fuse F Connector E TP SCR SCR DB SCR SCR TP E E TP TP RB RB F TP J % % % % % RB J Line St Min/Off Spd/Trq Burden Tach V Arm V V J V V RB TP RB J J J V J V Control Board _-DC Rev_ TB TB Max Spd RB RB Min Spd Tach TP G R Cur Lmt IR/ Tach RE Cur Lmt A- A+ F- F/ F+ L L Current Limit Pot IR/Tachometer Bi-Color LED Green = Power Red = Current Limit Logic & Signal Connection Terminals AC Line Connection Terminals Motor Shunt Connection Terminals Motor Armature Connection Terminals Connector E Shunt Resistors Figure. BETA II Control Board, / - HP P--BG Boston Gear BETA ll Series

Index A AC Line Protection..................... AC Supply Transients.................... ACCEL Potentiometer................... Acceleration, Linear..................... Altitude, Standard...................... Ambient Temperature................... Antiplug Circuit........................ Antiplug Feature....................... Anti-Restart Feature..................... Armature Feedback Backup.............. Atmosphere............................ Auxiliary Contact....................... C Circuit Breaker.......................... Conduit Entry.......................... Control Wiring.......................... Controlled Speed Range................. Controller Construction................... Controller Mounting..................... CSA................................. Current Limit Potentiometer.............. Current (Torque) Limit Potentiometer....... Current (Torque) Reference Potentiometer... Current Limit.......................... Current Limiting Fuses................... D Decel Potentiometer.................... Deceleration, Linear.................... Disconnect Switch...................... Displacement Power Factor (Rated Speed/Rated Load).................. Duty................................. Dynamic Braking....................... Dynamic Braking Resistors............... E Efficiency (Rated Speed/Rated Load)....... Electrical Noise......................... F Supply.......................... Full-Wave........................ Fuses................................. G Ground Screw.......................... Grounding............................. H Half-Wave Shunt Voltage............ Horsepower Range..................... I IR (Load) Compensation................. IR/Comp Potentiometer................. Isolation Transformer..................... J Jog Speed............................ Jog Speed Potentiometer................ Jumper J, J, J and J................. L Line Frequency Variation................. Line Fuse............................. Line Fuse Interrupting Capacity........... Line Power........................... Line Starting.....................,, Line Supply............................ Line Voltage Variation................... Low Inductance Motors.................. M Max Spd Potentiometer................. Maximum Speed...................., Min Spd Potentiometer.................. Minimum Speed...................., Minimum Transformer KVA................ Motor Contactor....................... Motor Rotation........................ Motor Speed Potentiometer.............. N National Electrical Code................, NEMA............................... NEMA Type and Standards............ O Oscillating Load....................... Overload Capacity, Armature Circuit........ P Power Bridge.......................... Power Conversion...................... Power Factor Correction Capacitors........ Power Wiring........................., R Relative Humidity...................... S Boston Gear BETA ll Series P-BG

Index Selectable Capabilities.................. Service Factor......................... Shielded Wire.......................... Shipping Damage....................... Short-Circuit Current..................... Signal Wiring........................... Speed Regulation...................... T Tachometer Feedback................, Torque (Current) Limit................... Torque Regulator....................... Transformer........................., Transients............................. Twisted Cable.......................... U Underwriter Laboratories Listed............ V Varistor............................, Vibration.............................. Voltage Transient Protection............, P--BG Boston Gear BETA ll Series

Warranty Boston Gear warrants that products manufactured or sold by it shall be free from defects in material and workmanship. Any products which shall within two () years of delivery, be proved to the Company s satisfaction to have been defective at the time of delivery in these respects will be replaced or repaired by the Company at its option. Freight is the responsibility of the customer. The Company s liability under this limited warranty is limited to such replacement or repair and it shall not be held liable in any form of action for direct or consequential damages to property or person. The foregoing limited warranty is expressly made in lieu of all other warranties whatsoever, express, implied and statutory and including without limitation the implied warranties of merchantability and fitness. No employee, agent, distributor, or other person is authorized to give additional warranties on behalf of Boston Gear, nor to assume for Boston Gear any other liability in connection with any of its products, except an officer of Boston Gear by a signed writing. Boston Gear Hayward Street Quincy, MA -- Fax: -- www.bostongear.com An Altra Industrial Motion Company P--BG / Printed in USA