Installation, Operation & Maintenance Manual. Bulletin: IOMS-PUL CHEMAlarm LEAK DETECTIONI

Similar documents
DC Variable Speed Drive Panel

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

INSTALLATION OPERATION MAINTENANCE INSTRUCTION

E.S.P. Embedded Sensing Probes for Motor Brushes

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

M100F Incremental Motor Actuator R81F Interface Board

TECHNICAL DATA CAUTION

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

1100 Series Piston Type Differential Pressure Gauges

M9216 Series Electric Spring Return Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Relay Contact Ratings. Operating Temperatures. Life Expectancy. Humidity Tolerance Enclosure Mounting Weight

ELECTRIC ACTUATORS. Series 70 Pgs 4-11 PRODUCT QUALITY & PRECISION INTRODUCTION

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Model 550 Series Vibration Switches

RP-4000 Reserve Power Control

Installation Instructions

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Installation, Operation, & Maintenance Instruction. Bulletin #: IOM-PN-LCM D

PRODUCT INFORMATION BULLETIN

PRO REMOTE Series CAPACITANCE PROBE

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

R & D SPECIALTIES ROTROL I USER'S MANUAL

Installation, Operation & Maintenance Supplement Instruction. Bulletin No.: IOMS-PUL PULSA Series 7120V DRIVE MOTOR INSTALLATION

M-100 Adjustable flow switch with right-angle flow

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

System 350 P352AB Electronic Pressure Control Series

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

Installation Instructions

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

Purging Air From Divider Block Lubrication Systems

Application Engineering

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

D I S S O L V E D O Z O N E M O N I T O R INSTRUCTIONS FOR USE

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

How to Select Automation Accessories for Valves

TotalPac 3 Firecyle III Wet pipe Remote controlled system

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

Installation Operation Maintenance ADDENDUM

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

WATER PROCESS SOLUTIONS

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Boston Gear Ratiotrol

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

RESISTIVITY MONITOR/CONTROLLERS

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications


Engineering Operation & Maintenance. Leak Detector. Advance your process TO REPLACE WIL E-01 WIL E-01

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Electric Actuator Instructions

DIAMOND POINT VIBRATING PROBES

Solstice Electric Fryers SE Series Service Manual

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Model DFR 070/156/220 Rotary Actuator

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Myers Vacuum RD # 2 Box 247A Kittanning, PA Phone: Fax: Instruction Manual For Thermistor Gauge GT-340A

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

CIRCLE SEAL CONTROLS

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12.

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

P445 Series Electronic Lube Oil Control

T21 Thermal Differential Switch

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Installation and Operating Manual

SECTION DC POWER SUPPLY/BATTERY CHARGER

M9220-xxx-3 Electric Spring Return Actuators

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Table Of Contents. Section Description Page #

COM Overcurrent Relay

PATENT PENDING. Phone: (877) Operation and Service Manual

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

BULLETIN No.: PulsaPro 900-IOM-2009 Rev. J PulsaPro Control Addendum INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS

Locktite Manual Reset Gas Shut-Off Valves

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Series 44 Installation Instructions

TECHNICAL DATA. Trimpac 244a. April 15, 2011

CIRCLE SEAL CONTROLS

L5000 Plus. Installation & Setup Guide

PRO REMOTE 25 LV CAPACITANCE PROBE

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

Transcription:

Installation, Operation & Maintenance Manual Bulletin: IOMS-PUL-1011 CHEMAlarm LEAK DETECTIONI 1

TABLE OF CONTENTS 1. PRINCIPLES OF OPERATION... 3 1.1 General Description... 3 1.2 Process Specifications... 3 1.3 System Specifications... 3 1.4 Process Description... 4 1.5 Circuit Operation... 4 2. INSTALLATION... 5 3. START-UP... 5 3.1 Calibration... 5 4. MAINTENANCE... 6 4.1 Periodic Checks... 6 4.2 Conax Probe Disassembly... 6 4.3 Conax Probe Assembly... 6 4.4 Pulsafeeder Probe Disassembly... 7 4.5 Pulsafeeder Probe Assembly... 7 5. TROUBLESHOOTI NG... 8 6. REPLACEMENT PARTS... 9 7. SPECIFICATIONS... 9 8. ILLUSTRATIONS... 10 8.1 Typical Pump Installation... 10 8.2 Wiring Diagram-Standard Relay Output... 11 8.3 Wiring Diagram-Contactor Output... 12 8.4 Conax Probe Assembly... 13 8.5 Pulsafeeder Probe Assembly... 14 8.6 Enclosures... 15 2

1. PRINCIPLES OF OPERATION 1.1 General Description (Figure 1) The ChemAlarm monitors the electrical conductivity of the intermediate liquid in a double-diaphragm metering pump. Monitoring is performed by a dual-electrode electrical probe installed in the intermediate chamber, and associated electronic circuitry. The intermediate liquid is selected to have a different conductivity from the process liquid, the hydraulic liquid, or both. Failure of the primary (process) diaphragm, or the secondary (hydraulic) diaphragm, or both, results in contamination of the intermediate chamber by a foreign liquid, changing the conductivity within the chamber accordingly. This change is sensed by the circuit as an indicator of diaphragm failure. In a typical installation, the conductivity probe is wired at the factory to a junction box mounted on the pump. A control box containing the control module and output relay (or auxiliary contactor, if specified), is mounted remotely and wired to the junction box at the time of pump installation. ChemAlarm output is communicated by relay or contactor operation and is typically used to signal an alarm and/or to shut down the pump in the event of diaphragm failure. 1.2 Process Specifications ChemAlarm installations are of a custom nature, to meet the requirements of specific applications. These requirements, or process specifications, along with the resulting system specifications, are established prior to use; however, it is important for the user to be familiar with them in order to adapt to changes in process. Process specifications are: Conductivity of the process liquid Specific gravity of the process liquid Diaphragm monitored (Typically the primary, or process diaphragm) Output signal 1.3 System Specifications These specifications are developed in response to process specifications. They define the system supplied. Intermediate Liquid Selection Conductivity Specific gravity Miscibility with product liquid Sensor Probe Location Top Bottom Midpoint Sensing Mode Forward Reverse Conductivity Range Standard 3

Extended Output Relay Contactor 1.4 Process Description Since the product diaphragm is the primary containment barrier and since it is more likely to fail than the secondary diaphragm, most installations are designed to detect primary diaphragm failure. In some instances such a design will incidentally detect secondary diaphragm failure, but this is typically not the case. This discussion deals with detection of primary diaphragm failure; the same principles apply to the secondary diaphragm. The unit of conductivity is microsiemens per centimeter. Liquid conductivity ranges from nearly a million for certain acids to nearly zero for certain oils. To facilitate detection, the intermediate liquid is selected to have as different a conductivity as possible from the process liquid. The selection is also influenced by chemical compatibility and viscosity. Where the conductivity of the process liquid is greater than that of the intermediate liquid, the forward mode of sensing is applied: an increase in conductivity triggers detection. Where the conductivity of the process liquid is lower, the reverse of sensing is applied: a decrease in conductivity triggers detection. The probe can be situated at the top, bottom, or midpoint of the intermediate chamber. Where the process and intermediate liquids are immiscible or of significantly different specific gravities, change is likely to occur first at the top or bottom of the intermediate chamber. Detection is enhanced by positioning the probe in one of these locations, depending on the specific gravities. For example, consider an application in which nitric acid, 5% by weight, is being pumped, and for which ethylene glycol solution, 50% by weight, has been selected as an intermediate liquid. Temperature is 25 C. Forward mode sensing has been specified. The circuit will be calibrated to the ethylene glycol, which has an approximate conductivity of 2150 microsiemens/cm. Since the nitric acid has an approximate conductivity of 275,000 microsiemens/cm, over a hundred times the initial level, effective detection can be anticipated. Note that forward mode sensing is essential as reverse mode sensing detects only a decrease, but not an increase, in conductivity. 1.5 Circuit Operation A 24 VAC potential is applied across the two probes submerged in the intermediate chamber. The frequency of this signal is the same as that of the power supply, 50 or 60 HZ. A minute current, typically 500 microamperes, is conducted between the probes by this liquid in the chamber. Probe current is circuit-limited to a maximum of 10 milliamperes; a continuous short or ground will cause no harm. The sensing circuit is calibrated to the normal operating condition, after which it will detect and signal a change in conductivity. The circuit will either sense an increase in conductivity (forward model or a decrease (reverse mode). 4

2. INSTALLATION Connect AC power and probe leads per the pertinent wiring diaphragm (Fig. 2 or Fig. 3). Output contact ratings are given under "Specifications" below. To minimize electrical interference with the control signals, follow the procedure below for wiring of the probe leads between junction box and control box. 1. Isolate lead wires from power wiring. Do not run lead wires in the same conduit as power wiring. 2. All lead wires should be shielded and the shields grounded. 3. Dual control cable within the same shield should not exceed a length of twenty feet. Separate lead wires, individually shielded, can be used up to a length of 100 ft. 4. If the circuit board is installed as a component within an enclosure containing sources of electromagnetic interference, shield it with a grounded cover. 3. START-UP 3.1 Calibration Calibration adjusts the conductivity-sensing circuit so that a slight change in conductivity in the desired direction, due to diaphragm leakage, triggers the alarm. Initial calibration is the only procedure required at startup. 1. The control box must be powered and the intermediate chamber must be filled and purged of air. It does not matter whether or not the pump is operating. 2. Liquid conductivity varies significantly with temperature, so that an increase beyond calibration temperature can trigger a false alarm with a forward- mode control. A temperature decrease can similarly affect a reverse-mode control. Therefore, final calibration should be performed at normal operating temperature. 3. Calibration will cause several alarm signals. If this is unacceptable, disconnect power to the output circuits and disconnect the lead to output terminal "NO" (standard relay output, Fig. 2) or to output terminals T1 and T2 (contactor output, Fig. 3). 4. If the alarm has been deactivated per step (3) above, connect a multimeter, set in the continuity or resistance mode, to terminals "NO" and "C1" (Relay Output) or L1, and T1, (contactor output). In both cases, an open contact corresponds to the normal operating condition and contact closure corresponds to the alarm condition. 5. The calibration potentiometer is situated on the control circuit board inside the control box. It is the only potentiometer on the board. 6. Turn the potentiometer fully counterclockwise, for minimum sensitivity. 7. Slowly and carefully turn the potentiometer clockwise, increasing sensitivity, until the alarm signal is triggered. This references the circuit to the intermediate liquid. Decrease sensitivity by backing off the potentiometer 1/8 to 1/4 turn in the counterclockwise direction. This sets the circuit to detect a slight change of conductivity in the specified direction. 8. If the intermediate liquid has a very low conductivity, potentiometer adjustment will not trigger the alarm. In this case, leave the potentiometer in the most sensitive, or fully clockwise, position. 9. Replace signal leads and restore signal power, as necessary. 5

4. MAINTENANCE 4.1 Periodic Checks System operation should be confirmed on a regularly scheduled basis. Check calibration (see "Calibration"), which also verifies alarm circuit operation, except for an intermediate liquid of very low conductivity. In the latter case, confirm alarm circuit operation as follows: 1. For a forward mode system, simulate the alarm condition by momentarily shorting the probe circuit. Connect a test lead to terminal "H" on the circuit board and short to terminal "C" (or "CM") with a probe on the other end of the lead. 2. For a reverse mode system, simulate the alarm condition by opening the probe circuit. Momentarily disconnect the lead from either terminal "H or "C (or CM") on the circuit board. 4.2 Conax Probe Disassembly (See Figure 4) 1. Drain the intermediate liquid to a level below the probe. Refer to the pump operation bulletin. 2. Unscrew the tubing nut (1) and free the metal protective tubing from the elbow fitting (2). 3. Disconnect the wire leads at the junction box and withdraw them from the protective tubing to free up the probe assembly. The wire can be reused, provided sufficient length remains after trimming. 4. Unscrew bulkhead fitting (10) from the intermediate head. 5. Unscrew gland fitting (3) from the bulkhead fitting. 6. Straighten or clip the two protruding probe wires. 7. Remove all parts and inspect for damage. 4.3 Conax Probe Assembly (See Figure 4) 1. Strip about 1/4" of insulation from both wire ends. Ensure that the lengths of the probe wires are sufficient to reach the termination point in the junction box. 2. Insert the wires through the tubing nut (1) and elbow fitting (2) down flush against the bulkhead fitting. Spread the wires into an included bottom angle of about 60 to retain the insulator. Trim the wire ends to V." approximate length. Verify that they do not contact one another and that neither will contact the walls of the probe port in the intermediate head. 3. Screw gland fitting (3) into the elbow fitting and tighten. 4. 4. Position the insulation end of both stripped wire leads even with the top of the gland fitting and insert the wires into the long insulator (4). Slide the insulator down, pushing the tubing, until the insulator extends about ¼ above the gland fitting. 5. Position antirotation set pin (6) into the blind end of the external groove in metal sleeve (5). It can be held in position during assembly by a metal- to-metal adhesive. 6. Insert the wire ends into the sleeve, with the open end of the groove in the sleeve pointing down, and lower the sleeve around the long insulator (4) until it bottoms against the gland fitting. 7. Insert the wire ends in short insulator (9) followed by Teflon gland seal (8) with beveled end up. Slide the seal down flush against sleeve (5). 8. Insert the wire ends in short insulator (9) and slide the insulator down flush against the gland seal. 6

9. Slip bulkhead fitting (1), straight threads down, over the assembly, taking care to engage set pin (6) in the interior groove in the bore of the bulkhead fitting. Screw the bulkhead fitting into the gland fitting (3) and tighten. 10. Insert the wire ends into short insulator (11) and slide the insulator. Install the probe assembly in the intermediate head and tighten the bulkhead fitting. Spread the wires into an included bottom angle of about 60 to retain the insulator. 11. Trim the wire ends to 1/8 approximate length. Verify that they do no contact one another and that neither will contact the walls of the probe port in the intermediate head. 12. Install the probe assembly in the intermediate head and tighten the bulkhead fitting (10) only. 13. Using a multimeter, verify that the probe leads are not shorted to one another and that neither is grounded to probe assembly or intermediate head. 14. Install the protective tubing. Install and terminate the wire leads in the junction box. 15. Refill and plug the intermediate chamber. Prime and start the pump in accordance with procedures in the pump operations manual. 16. Check calibration (see "Calibration"). 4.4 Pulsafeeder Probe Disassembly (See Figure 4A) 1. Drain the intermediate liquid to a level below the probe. Refer to the pump operation bulletin. 2. Unscrew the tubing nut (1) and free the metal protective tubing from the elbow fitting (2). 3. Disconnect the wire leads at the junction box and withdraw them from the protective tubing to free up the probe assembly. The wire can be reused, provided sufficient length remains after trimming. 4. Unscrew bulkhead fitting (8) from the intermediate head. 5. Unscrew gland fitting (3) from the bulkhead fitting. 6. Straighten or clip the two protruding probe wires. 7. Remove all parts and inspect for damage. 4.5 Pulsafeeder Probe Assembly (See Figure 4A) 1. Strip about ¼ of insulation from both wire ends. Ensure that the lengths of the probe wires are sufficient to reach the termination point in the junction box. 2. Insert two or three inches of the wires through the tubing nut (1) and elbow fitting (2). 3. Screw gland fitting (3) into the elbow fitting and tighten. 4. Position antirotation set pin (5) into the blind end of the external groove in compression sleeve (4). It can be held in position during assembly by a metal-tometal adhesive. 5. Insert the wire ends into the compression sleeve and lower the sleeve until it bottoms against the gland fitting. 6. Insert the wire ends in one insulator (6), followed by Teflon gland seal (7). Slide the insulator and seal down flush against sleeve (4). 7. Insert the wire ends in the other insulator (6) and slide the insulator down flush against the gland seal. 8. Slip bulkhead fitting (8), straight threads down, over the assembly, taking care to engage set pin (5) in the interior groove in the bore of the bulkhead fitting. Screw the bulkhead fitting into the gland fitting (3) and hand tighten. Pull the wires back through 7

from the tubing nut end until only a 1/8 extension is left. Tighten the bulkhead and gland fitting together. 9. Spread the wires into an included bottom angel of about 60. 10. Trim the wire ends to 1/8 approximate length. Verify that they do not contact one another and that neither will contact the walls of the probe port in the intermediate head. 11. Install the probe assembly in the intermediate head and tighten the bulkhead fitting (8) only. 12. Using a multimeter, verify that the probe leads are not shorted to one another and that neither is grounded to probe assembly or intermediate head. 13. Install the protective tubing. Install and terminate the wire leads in the junction box. 14. Refill and plug the intermediate chamber. Prime and start the pump in accordance with procedures in the pump operations manual. 15. Check calibration (see Calibration ). 5. TROUBLESHOOTI NG DIFFICULTY Failure to alarm False alarm Circuit board check PROBABLE CAUSE No power to circuit board No power to alarm circuit(s) Wiring discontinuity in control box Probe leads shorted, open, or grounded Relay or contractor failure Calibration (consider temperature change beyond the limit of previous calibration) Corroded probes Circuit board failure Probe leads shorted, open, or grounded Calibration (consider temperature change beyond the limit of previous calibration) Corroded probes Circuit board failure NOTE: Relay operation is audible and can be observed through the transparent cover Shut off power to supply terminals L1 and L2 Disconnect probe leads from terminals H and C Turn the calibration potentiometer fully counterclockwise to stop, then ¼ turn clockwise Apply power to terminals L1 and L2, the relay should not energize Apply a jumper between terminals H and C, the relay should energize, remove the jumper, the relay should de-energize Turn the calibration potentiometer fully clockwise. The relay should remain deenergized 8

For models LCS and LCR, the relay should energize when a 9.1 K ohm or 10 K ohm resistor is connected between terminals C and H For models LHS, the relay should energize when a 2.7 megohm, or 3.0 megohm resister is connected between terminals C and H 6. REPLACEMENT PARTS When ordering replacement parts, always specify: 1. Pump model and serial number (stamped on pump nameplate) e.g., Model 7120- S-AE, Serial No. 8604146-1. 2. The part name and number from the Parts List. 7. SPECIFICATIONS Power Control signal Control options Load contacts (LCS & LCR) Load contacts (LHS) Load contacts (LCS, LCR, or LHS, with auxiliary contactor) Control box ambient temperature range Control box enclosure 120 VAC, single phase, 50/60 Hz OR 240 VAC, single phase, 50/60 Hz (optional) Maximum consumption: 3 watts 24 VAC, 50/60 Hz (frequency same as power supply) Typical current: 500 microamperes Maximum current: 10 ma (as limited) Resistance Model Mode Range Forward (actuates and below LCS 100,000 ohms LCR LHS Up to 100,000 ohms 3 megohms SPDT (single pole double throw) 10 amperes, non-inductive ¼ HP at 120 VAC 1/3 HP at 240 VAC SPDT (single pole double throw) 10 amperes, non-inductive 1/6 HP at 120 VAC 1/3 HP at 240 VAC upon increase in conductivity) Reverse (actuates upon decrease in conductivity) Forward (actuates and below upon increase in conductivity) DPST (double pole, single throw), normally open 1 HP at 120 VAC 2 HP at 240 VAC 32 F to 140 F NEMA 3 (standard) NEMA 4 (optional) NEMA 7 (optional) 9

8. ILLUSTRATIONS 8.1 Typical Pump Installation Figure 1 10

8.2 Wiring Diagram-Standard Relay Output Figure 2 11

8.3 Wiring Diagram-Contactor Output Figure 3 12

8.4 Conax Probe Assembly Figure 4 13

8.5 Pulsafeeder Probe Assembly Figure 4a 14

8.6 Enclosures Figure 5 15

CHEMAlarm LEAK DETECTION Bulletin: IOMS-PUL-1011 Pulsafeeder, Inc. A unit of IDEX Corporation 2883 Brighton Henrietta Town Line Road Rochester NY 14623 +1 (585) 292-8000 www.pulsa.com pulsa@idexcorp.com 16