TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Similar documents
Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Low Voltage General Purpose Motors

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

champion series motors

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Design specifications

Low Voltage General Purpose Motors

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

TRANSNORM LOW VOLTAGE MOTORS IC 411 TN LV 1 4E5

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

Guideline No.: E-03(201610) E-03 MOTORS. Issued date: October 28,2016. China Classification Society

Catalog. Low voltage Industrial performance motors

LIST OF PUBLISHED STANDARDS

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

Series E4F E5F

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

SECTION MOTOR REQUIREMENTS for HVAC

Unified requirements for systems with voltages above 1 kv up to 15 kv

INTERNATIONAL STANDARD

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

Drive IT Low Voltage General Purpose Motors

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

ELECTRIC MOTORS 3SIE IE3

SINGLE PHASE TEFC CAGE MOTORS

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

A few tips on how to select contactor for use in direct on line starter

YKK High-voltage Three-phase Asynchronous Motor

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

INTERNATIONAL STANDARD

Motors for hazardous areas New cast iron motors in sizes

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

TECHNICAL SPECIFICATION

Low Voltage Induction Motors

TECHNICAL SPECIFICATION

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

Electrical Motors. Witt&Sohn AG Oct-14

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

IECEx Certificate of Conformity Annexe

Demonstrate knowledge of electrical theory for Electrical Service Technician B

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

ABMA , Radial Bearings of Ball, Cylindrical Roller and Spherical Roller Types Metric Design.

INTER PLANT STANDARD STEEL INDUSTRY

From 4 to 20 poles ( over contact MM) IP 23. Available up to IP 44 with filters.

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC.

Low Voltage General Purpose Motors

1LG0 Low-voltage Motors

Starting of Induction Motors

Unit 34 Single-Phase Motors

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

Cutting-edge technologies backed by a century of experience

Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

Scope of Supply of 11Kv Induction motor. The motor is being procured for cooling water pump. The scope of supply of motor is as given below:

Catalog Low voltage Process performance motors

300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC

TEKNISK RIKTLINJE TR05-10E

شركة كهرباء محافظة القدس المساهمة المحدودة

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

CE Marking. Number of poles. Core Length. Frame size

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

A B C D, E, F M2BA 112 MB 3GBA ADB, 122, 451, etc

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Three-phase asynchronous motors

Catalog. Low voltage General performance IE2 high efficiency motors according to EU MEPS

Technical Specification For Outdoor Substation Harmonic Filter Banks

W22 Medium Voltage Motors TEFC - Severe Duty

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

TECHNICAL SPECIFICATION

Distribution transformers Efficiency over life-cycle

PASS M00. Multifunctional modules for high voltage substations kv; A;... 31,5 ka

Asynchronous generators

Faster project implementation. Earlier return on invest. SIMOTICS HV M shaft height 450 to 800: the modular motor concept up to 19 MW

Motors for use on a frequency converter

Australian Standard. Rotating electrical machines. Part 9: Noise limits AS IEC , Ed. 4.1 (2007) AS

Transcription:

Page 1 (7) TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT Title Document Asynchronous electric motors TBE 103 Issue 6 (E) Contents 1 GENERAL... 2 2 DEFINITIONS... 2 3 GENERAL PRODUCT REQUIREMENTS... 3 3.1 Standardisation... 3 3.2 Technical requirements... 4 3.3 Wet motors Additional requirements... 5 4 NUCLEAR SPECIFIC REQUIREMENTS... 5 4.1 Motors to be installed in the reactor containment... 5 4.2 Starting conditions... 5 4.3 Restart... 5 4.4 Phase opposition... 6 4.5 Impulse voltage withstand levels... 6 4.6 Dielectric strength (Withstand voltage tests)... 6 4.7 Insulation resistance... 6 4.8 Replacement parts... 6 4.9 Bearing cages... 6 5 DOCUMENTATION... 6 6 AGREEMENTS BETWEEN MANUFACTURER AND PURCHASER... 7 Document Issue Date Supersedes TBE 103 6 (E) 2013-08-20 Issue 5 (E)

TBE 103 5 (E) Page 2 (7) 1 GENERAL These Technical Requirements specify general requirements applicable to asynchronous electric motors intended for use in nuclear power plants. The requirements concern design, construction and documentation. Some requirements are therefore applicable only for certain types of equipment. The Manufacturer/Supplier must fulfil the requirements in order to meet the safety and reliability objectives of the Swedish Nuclear Power Plant (NPP) Owners. In addition to the requirements in this document, applicable parts of TBE 100 General Technical Requirements and Explanations, shall apply. Detailed Technical Data, and in some cases other technical requirements to be followed, for the equipment is given in the Technical Specification. If the requirements of various documents differ, the Technical Specification shall have precedence. Section 6 is a checklist that should be used in conjunction with making an inquiry or an order. 2 DEFINITIONS For general definitions see TBE 100 and KBE 100. Wet motors The term 'wet motors' refers to motors in which the rotor and stator with windings are immersed in circulating water which can be cooled in an external heat exchanger.

TBE 103 5 (E) Page 3 (7) 3 GENERAL PRODUCT REQUIREMENTS 3.1 Standardisation Asynchronous motors shall comply with relevant requirements in the following standards and in the noted order: IEC 60034-1 IEC 60034-2 IEC 60034-6 IEC 60034-7 IEC 60034-8 IEC 60034-9 IEC 60034-12 IEC 60034-14 IEC 60034-15 IEC 60034-18-1 IEC 60072 ISO 8821 SS-EN 50209 Rotating electrical machines - Part 1: Rating and performance Rotating electrical machines - Part 2-X: Methods for determining losses Rotating electrical machines - Part 6: Methods of cooling Rotating electrical machines - Part 7: Classification of types of constructions and mounting arrangements (IM Code) Rotating electrical machines - Part 8: Terminal markings and direction of rotation Rotating electrical machines - Part 9: Noise limits Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of the vibration severity (CENELEC HD 53.14 S1) Rotating electrical machines - Part 15: Impulse voltage withstand levels of form-wound stator coils for rotating a.c. machines Rotating electrical machines - Part 18: Functional evaluation of insulation systems -General guidelines Dimensions and output series for rotating electrical machines Vibration and shock - Mechanical vibration - Balancing - Shaft and fitment key convention Test of insulation of bars and coils of high-voltage machines Specific requirements of standards are described in the Technical Specification (TS). The Manufacturer/Supplier shall in the quotation show degree of compliance with the regulations and applicable product standards. Rating shall be in accordance with IEC 60034-1 for continues running duty (duty type S1) at rated output unless otherwise specified in the Technical Specification. Since the greatest degree of uniformity in the plant is desirable, the Manufacturer/Supplier is to choose make and type of equipment in consultation with the Purchaser.

TBE 103 5 (E) Page 4 (7) 3.2 Technical requirements 3.2.1 Starting prerequisites Starting method Motors shall be designed for direct-on-line starting, unless otherwise specified in the Technical Specification. Starting current The supplier shall specify the motor s starting current in the offer. If the purchaser has specific limitations in the motors starting current it shall be stated in the Technical Specification. Torque characteristic The supplier shall specify the motor s starting torque/speed curve at U N (rated voltage) and at 70 % of U N in the offer. 3.2.2 Direction of rotation Terminals shall be marked in accordance with IEC 60034-8. Direction of rotation must be clearly indicated in the installation documents, and marked with an arrow on high-voltage motors. 3.2.3 Terminal box design For motors rated at 1 kv or below, the terminal box shall be so designed that copper cables with crimped cable lugs can be used optionally. Other arrangements may be accepted for smaller motors prior to the Purchasers approval. 3.2.4 Terminal box size If several different sizes of terminal boxes can be installed on a given motor, the largest type shall be chosen, unless otherwise stated in the Technical Specification. 3.2.5 Auxiliary equipment connections Auxiliary equipment may not be connected via the terminal box for the motor s power supply. Heater and measuring equipment may not have a common terminal box. 3.2.6 Vibration Motors shall with regard to vibrations meet the standard (IEC 60034-14) class B. Balancing shall be done with a half key in accordance with ISO 8821. 3.2.7 Bearing monitoring Unless otherwise specified in the Technical Specifications, fittings for shock-pulse measurement transducers shall be provided at both bearing plates of motors having a power rating of 55 kw or more. 3.2.8 Surface treatment Surface treatment of motors located in areas with severity B, C and D according to TBE 101 shall be in accordance with TBY or requirements specified in TS. It shall withstand decontamination agent and high-pressure washing.

TBE 103 5 (E) Page 5 (7) 3.3 Wet motors Additional requirements 3.3.1 Operating conditions Wet motors shall be designed for direct on line starting at rated voltage, and must withstand reverse rotation at full speed. 3.3.2 Motor winding Motor windings shall be designed with continuous conductors without any joints in the water-filled parts of the motor. However, if a star-point or other connection must be arranged in a water-filled part, the Purchaser shall have approved the method and type of insulation to be used in advance. 3.3.3 Temperature sensors Motors shall be fitted with sensors for winding temperature monitoring in accordance with requirements specified in the Technical Specification. Alternatively, measuring winding circuit resistance may monitor the temperature. Temperature sensors shall be fitted in thermo wells, so that they can be replaced without need of draining the system. 3.3.4 Pressure resistance Components used in wet motors must not be damaged in any way by hydrostatic testing at a pressure of 1,3 times the design pressure of the motor casing or coolant circulation system. 4 NUCLEAR SPECIFIC REQUIREMENTS 4.1 Motors to be installed in the reactor containment 4.1.1 Materials Choice of material shall be performed in accordance with the environment existing at normal and extreme conditions and at design basis event with respect to temperature, pressure, radiation and humidity. Aluminum shall be avoided. 4.1.2 Lubrication The lubrication interval shall be two years or more. 4.2 Starting conditions 4.2.1 Starting time for motors with rated output of 7,5 kw or less Motors with rated output of 7,5 kw or less shall be designed for short starting times: less than three seconds at rated voltage. 4.2.2 Starting time for other motors Motors with rated output of 7,5 kw or more that run equipment such as fans, shall have a starting time of less than 12 seconds at rated voltage and less than 15 seconds at 70 % of rated voltage, unless otherwise stated in the Technical Specification. 4.3 Restart At rated voltage and at the intended load, electric motors shall withstand three starts in succession from hot state after running at normal operating conditions, without the stator winding temperature exceeding the limits set down in standards by more than 20 C.

TBE 103 5 (E) Page 6 (7) If the recovery time is longer than one hour, the supplier shall specify this in the offer. 4.4 Phase opposition Low-voltage motors shall be designed to withstand a start at full operational voltage when the remnant voltage at the motor terminals is 0,6 U N and in full phase opposition. The corresponding value for high-voltage motors (>1 kv) is 0,9U N. 4.5 Impulse voltage withstand levels Motors with form-wound stator coils rated at more than 1 kv shall be designed so that they, when running, can withstand impulse voltage(u p ) of at least U p =4U N + 5kV and having a front time of 1,2 µs and a time-to-half of 50 µs (IEC 60034-15). 4.6 Dielectric strength (Withstand voltage tests) The dielectric strength of motors shall be designed to withstand voltages levels that are in according with IEC 60034-1. 4.7 Insulation resistance The manufacturer shall state in the quotation the values for the insulation resistance on the motors electrical insulating system (EIS). Table 1 below is the minimum requirements for the EIS. Table 1 Motor type Minimum Requirements High-voltage motors at 40 C 10 000 M Low-voltage motors at 20 C 1000 M Wet motors at 20 C 2000 M Motor accessories According to TBE 100 Bearing insulation Manufacturers standard 4.8 Replacement parts Replacement parts that might affect the qualification status shall be specified. 4.9 Bearing cages Ball and roller bearing cages of plastic material are not allowed without approval by the Purchaser. 5 DOCUMENTATION In addition to documentation required in TBE 100 and KBE 100 the following are required: Dimensioned drawing Connection diagram, motor and any extra equipment List of apparatus for any extra equipment Maintenance instructions / lubrication instruction Torque/speed graph Record of temperature rise test

TBE 103 5 (E) Page 7 (7) 6 AGREEMENTS BETWEEN MANUFACTURER AND PURCHASER The list below shall be used as a frame in discussions between Manufacturer/Supplier and Purchaser in connection with offers or orders. 1 Review and complementary addition of the Technical Specification 2 Review of valid Inspection plan and inspection procedures 3 Verification of seismic requirements 4 Type of motor; cast iron or aluminum? 5 Temperature rise tests at rated voltage and output 6 Torque/speed curve at U N and at 0,7 U N 7 Requirements on starting time 8 Connection point for earth wire dimension and design 9 Terminal box size in relation to the connecting cable 10 Top or side mounted terminal box 11 Surface treatment, TBY 12 Drain hole 13 Sensors for measuring of winding temperature, number and location 14 Number and location of fitting for shock pulse measurements 15 Vibration requirements 16 Measuring method and the mounting arrangement for bearing monitoring 17 Heater for downtime heating 18 Will the motor be delivered with draw key? 19 Radial load 20 Noise level 21 Current transformers 22 Torque at installation of connection terminals for feeder cable 23 Equivalent diagram 24 ATEX (EX-classification) 25 Temperature sensors and other accessories 26 Bearing current requirements 27 Additional requirements regarding motors for speed controlled operation: 28 Is the motor designed for speed-controlled operation with respect to heating? 29 Can the cooling of the motor be maintained at low speed, external fan? 30 Range of speed regulation? 31 Are there any requirements for special connection cable with respect to EMC? 32 33 Additional requirements for motors located inside the reactor containment: 34 Ability to handle pressure variations in connection with pressure tests of the reactor containment 35 Is it possible to have a lubrication interval of two years? 36 Does the organic material involved meet the current environmental requirements? 37 Is material sensitive for radiation included in the motor, e.g. lubricating grease? 38 Functional evaluation of electrical insulation systems (aging) IEC 60034-18 39