Fuse Panels, Fuse Holders and Fuses

Similar documents
Fuse Panels, Fuse Holders and Fuses

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

FUSE PANEL PRODUCT MANUAL


NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Circuit protection for telecom applications

CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Products. Section Contents

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

Product Manual Select Code Comcode Issue 9 September Secondary DC Power Distribution Bay H

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/

Telecom Protection Products

5067 Mini BDFB / BDCBB

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

TPM/GMT Panel Installation Guide

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Special Purpose Fuses

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel


CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

Type SJK Test Switches

Fuse / Circuit Breaker Panels

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

twin engine two battery bank split charge system

Secondary DC Distribution

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512


PowerWorx DSX Series GMT Fuse Panel User Manual

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds

LAB 7. SERIES AND PARALLEL RESISTORS

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

VSM V-COUNT II are registered trademark of APEXS, Inc.

Fuse and Distribution Module

GMT Fuse Panel Installation Guide

ches UL File No. E101598

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

TIP SHEET T0491. Installation Tips for your Excalibur RS Passlock-sl2(4) + DLRC + SPDT

:: :: TFD4 :: TFD6

Method Of Procedure For Retrofitting ECS Power Systems (CC )

750 Paso Wiring Upgrade

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Demarcation Fuse Alarm Panel

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Technical Information and Diagnostic Guide

ECHO 8 Kit - Installation Manual

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

MAIN INCOMER -1 (500 KVA TRF.)

Circuit Breaker Types

Bussmann series Quik-Spec Power Module Switch elevator disconnect

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

CON EDISON EQUIPMENT

IEC Utilization Categories (Explanation)

General Purpose Flasher Circuit

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Installation Tips for your GMDLBP + Excalibur Remote Start system (for GM vehicles) v1.01 updated 10/09/13

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

Table No. 1 provides a means of identifying the various alternator systems. Note: All output figures are rated at 3600 RPM. TABLE NO.

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Central Locking Diagrams

Dual-Feed 600A Load Center Frame

USB Charge Port Installation Instructions

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

SCA-80(Q) C11 REPLACEMENT ASSEMBLY MANUAL

Power Distribution Units

Section 6: Parts Data

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation

Compact Circuit Protector (CCP)

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Application Note. Best Solutions for Managing High-Current Power Distribution

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

Product Manual Select Code Comcode Issue 4 April Lucent Technologies. Lineage 2000 Battery Plant J85500A-2

Type MTS Miniature Test Switches

Single pole connectors

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Remote Starter Integration for the 2007 Toyota Camry equipped with the Smart Key System with Push Button Start

Shaved-B. Installation Manual & Operation Instructions

Western Products, PO Box , Milwaukee, WI Hopper Spreader. Control Wiring and Electrical Components

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Circuit Breaker Types

MOTOALLIANCE WINCH MOUNT

Transcription:

DC Power Systems for Business-Critical Continuity Fuse Panels, Fuse Holders and Fuses 23" (58.42cm) Fuse Panels Description of Panels E/W Fuse Positions and Accessories Fuse Type Fuse Table Panel Height Notes Wrap & Solder Load Term 520987 (4) 0-5 A 70 A 1-3/4" (4.45cm) 2, 8 26-14 Ga Load Term* 431849300 (20-20) 0-10 A Split Load (20 A Max Per Side) Load & Grd. Rtn. Term Blocks GMT B 3/4" (1.91cm) 5 Wire Wrap Load Term 431622800 (50) 0-10 A (Accessory Grd. Bar 436105900) GMT B 3-1/2" (8.89cm) 5 1/4" (.64cm) Stud Load Term 431848900 (16) 0-60 A TPS C 7" (17.78cm) 3/4" (1.91cm) Stud (61-400 A), 7/8" (2.23cm) Stud (61-600 A) Load Term** 431407300 (1) 61-400 A TPL E 5-1/4" (13.34cm) 431407500 (1) 61-400 A E/W A 400 A Shunt TPL E 5-1/4" (13.34cm) 431605000 (2) 61-400 A TPL E 7" (17.78cm) 9 431605200 (2) 61-400 A E/W (2) 400 A Shunts TPL E 7" (17.78cm) 437417800 (2) 61-400 A A/F (2) Shunts & Ammeters TPL E 7" (17.78cm) 9, 10 431707900 (4) 61-400 A TPL E 10-1/2" (26.67cm) 431407400 (1) 61-600 A TPL E 5-1/4" (13.34cm) 431407600 (1) 61-600 A E/W A 600 A Shunt TPL E 5-1/4" (13.34cm) 9 431605100 (2) 61-600 A TPL E 7" (17.78cm) 431605300 (2) 61-600 A E/W (2) 600 A Shunt TPL E 7" (17.78cm) 437417900 (2) 61-600 A A/F (2) Shunts & Ammeters TPL E 7" (17.78cm) 9, 10 431707800 (4) 61-600 A TPL E 10-1/2" (26.67cm) 431401000 (1) 61-600 A Fuse Switch Unit TPL E 7" (17.78cm) 9 431430700 (2) 61-600 A Fuse Switch Unit TPL E 12-1/4" (31.12cm) 431432100 (1) 61-600 A Fuse Switch Unit A/F Ammeter and Shunt TPL E 7" (17.78cm) 9, 11 Lug Adpt. Load Term 431201100 (1) 800-1,200 A KRPC F 5-1/4" (13.34cm) 12, 13 426172900 (1) 800-1,200 A Fuse Switch Unit W/WO Shunt KRPC F 12-1/4" 12, 14 * Lugs not required ** See Table M 1

19" (48.26cm) Fuse Panels Description Fuse Type Fuse Table Panel Height Notes Wrap & Solder Load Term 521090 (4) 0-5 A 70 A 1-3/4" (4.45cm) 2, 8 Wire Wrap Load Term 431653100 (40) 0-10 A (Accessory Grd. Bar 436105900) GMT B 3-1/2" (8.89cm) 5 431848800 (20-20) 0-10 A Split Load (Accessory Grd. Bar 436105900) GMT B 3-1/2" (8.89cm) 5 Term Block #6 Screw Load Term 431848300 (10-10) 0-10 A Split Load GMT B 1-3/4" (4.45cm) 5, 7 26-14 Ga Load Term* (20-20) 0-10 A Split Load (20 A Max Per Side) 431849300 Load & Grd. Rtn. Term Blocks GMT B 1-3/4" (4.45cm) 5 1/4" (.63cm) Stud Load Term 431849800 (12) 0-60 A TPS C 7" (17.78cm) Lug Adpt. Load Term 431406800 (1) 61-400 A TPL E 5-1/4" (13.34cm) 15 431408300 (1) 61-600 A TPL E 5-1/4" (13.34cm) 15 Rear Fuse Cabinet Assembly ( 431849300) 2

Rear 61-600 amp Fuse Panel Rear 61-600 amp Fuse and Switch Distribution Panel 3

Side Rear Battery Load Alarm 0 5 amp Twin Fuse Block (70 Type) Side Alarm Battery Load 0 10 amp Fuse Block (GMT type) Side 61 600 amp Fuse Block (bolt-in type) Side TPS Fuseholders 4

A) 70 Type Fuse B) GMT Type Fuse C) TPS / TLS Type Table A: 70 Type 70 Type Designation Pins amp Capacity Color 0.18 248620100 Yellow 248628100 0.25 248620200 Violet 248628200 0.25* 248620300 Violet/White 248628300 0.5 248620500 Red 248628400 0.75 248620600 Brown 248628600 1.33 248620800 White 248628900 2 248621200 Orange 248629200 3 248621500 Blue 248629400 5 248621700 Green 248629700 Table B: GMT Type amp Capacity Color 0.18 248610301 0.25 248610200 Violet 0.5 248610300 Red 0.75 248610500 Brown 1.33 248610700 White 2 248610800 Orange 3 248610900 Blue 4 248611100 Brown/White 5 248611000 Green 10 248611200 Red/White Dummy 248872600 Safety Cover 248898700 Table C: TPS / TLS Type amp Capacity TPS Type 3 248230900 5 248231000 6 248231200 10 248231500 15 248231800 20 248232100 25 248232400 30 248232700 40 248233300 50 248233900 60 248234200 70 248234500 80 118413 90 118414 100 118415 Bussmann GMT-A ALM Fuse for Use with TPS Holders 0.18 248610301 Safety Cover 248898700 5

D) TPN Type 1 30 amp D) TPN Type 35 60 amp Table D: TPN Type amp Capacity 1 248230500 3 248230800 6 248231100 10 248231400 15 248231700 20 248232000 25 248232300 30 248232600 35 248232900 40 248233200 45 248233500 50 248233800 60 248234100 Top End E) TPL Type Table E: TPL Type amp Capacity 70 248251500 80 248252000 100 248252600 150 248253300 200 248254000 225 248254500 250 248255000 300 248255700 400 248257000 500 248258000 600 248259000 F) KRP-C Type Table F: KRP-C Type amp Capacity 800 248548200 1000 248549600 1200 248550100 6

Table G: Ammeters & Shunts amp Ammeter Shunt Part Capacity Number 100 292486500 298274400 200 292487000 298274700 300 292487300 298274900 400 292487500 298275000 500 292487600 298275200 600 292487800 298275300 Table H: Ammeters & Shunts amp Ammeter Shunt Part Capacity Number 100 292486500 298274402 200 292487000 298274702 300 292487300 298274902 400 292487500 298275002 500 292487600 298275202 600 292487800 298275302 Table I: Shunts amp Capacity Shunt 800 298275400 1000 298275500 1200 298275600 Table J: Bus Bars Number of Fuse Blocks Connected 2 341210700 3 341211400 4 341211900 5 341251200 6 341251400 7 341251000 8 341254100 Table K: Lugs and Adapters Description Adapter E/W (1) 2-4/0 saddle lug 483554500 (1) 0-500MCM saddle lug 245619900 (1) 600-1000MCM saddle lug 245619000 Adapter E/W (2) 1/0-500MCM saddle lugs 423554600 Adapter for crimp lugs 3/8" (.95cm) hardware (1" [2.54cm] C-C) or 1/2" (1.27cm) hardware (1-3/4" [4.45cm] C-C) 362755800 7

Application Notes 1. Unless otherwise specified (Notes 2, 7 & 12), an alarm LED card part number 486331800, for use with power board equipment with a fuse alarm circuit, is furnished as standard. When no power board alarm circuit is available and an alarm LED and relay is required, specify panel e/w optional alarm LED and relay card part number 486331600. Specify voltage and polarity. 2. This assembly is equipped with an alarm LED and relay card part number 486331600. If not required, it may be replaced with a 486331800 alarm LED card. Specify voltage and polarity. 3. These fuse panel assemblies can be used for ±12, 24, 48 OR 130 volt applications unless otherwise specified (Note 5). 4. Apparatus mounting blanks are provided for all unequipped positions. 5. To be used up to 60 Volt DC only. 6. Contact Emerson Network Power for additional information concerning any specific fuse panel. Specify part number and request assembly drawing. 7. This assembly has an alarm relay and lamp arranged for ± 24 or 48 volt only. Specify voltage and polarity. 8. When a special arrangement is required, specify additional quantity of twin fuse block(s), part number 248840300 and busbar(s) required per Table J. 9. Unless otherwise specified, output lugs and lug adapters are not provided, order from Table K and lug tables in this catalog per job requirements. 10. Ammeters and shunts are not furnished with assembly and must be ordered from Table J per job requirements. 11. Ammeters and shunts are not furnished with assembly and must be ordered from Table I per job requirements. 12. This assembly is equipped with a fuse alarm resistor tapped for 250, 500 or 2,500 ohms for connection to a fuse alarm relay circuit. 13. Lug adapters are not part of this assembly, order (1) or (2) part number 363221900 lug adapter (A/F 3/8" (.95cm) HDW 1" [2.54cm] C-C or 1/2" [1.27cm] HDW 1-3/4" [4.45cm] C-C ). Order (1) part number 63556800 busbar for fuse to discharge bus when required. 14. Assembly is furnished with a lug adapter A/F (3)sets of mounting holes 3/8" (.95cm) HDW 1" (2.54cm) C-C. When a shunt is required, order assembly equipped with a shunt mounting block part number 381413300 and shunt from Table I as required. 15. Assembly is furnished with (2) lug adapters A/F (2) sets of mounting holes 3/8" (.95cm) HDW 1" (2.54cm) C-C and (1) set of mounting holes 1/2" (1.27cm) HDW 1-3/4" (4.45cm) C-C. How To Order 1. Specify part number for 19" (48.26cm) or 23" (58.42cm) fuse panel assembly as required. 2. Specify part number and quantities of fuses, shunts, lug adapters and other accessories from associated tables and application notes as required. 3. S pecify quantity and part number of lugs and adapters required (see Table K or the Ground Bars, Terminal Panels & Lugs data sheet from Accessories). Emerson Network Power. The global leader in enabling businesscritical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Outside Plant Integrated Cabinet Solutions Precision Cooling Site Monitoring and Services 2005 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson Network Power Energy Systems 1122 F St. Lorain, OH 44052 Toll Free: 800-800-1280 (USA and Canada) Telephone: 440-246-6999 Fax: 440-246-4876 Web: EmersonNetworkPower.com/EnergySystems This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Vortex, Candeo and LORAIN are trademarks of Emerson Network Power Energy Systems, North America, Inc. 8 Printed in USA