IsoLED FLEX I CUSTOMER MANUAL

Similar documents
ISOLED XII OPERATIONAL / SERVICE MANUAL

6 Bay Battery Charger Operation Manual

Xenon Fiberoptic Lightsource

Model: SL360R Lithium Ion 360 LED Cordless Work Light

HEINE NT4 MED V

Cordless Endodontic Handpiece. Manual Revision Date: July 2005 OPERATION MANUAL

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

Product Data Sheet : LIGHTHAWK 6 CELL

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

SURGICAL LIGHTING SYSTEM INSTALLATION AND SERVICE MANUAL. System Two LED Installation and Service Manual ( Rev E)

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

SmartVent. Instructions for Use Version 4 (Dec 2009)

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

MODELS 2 & 4 Top Conduit Linears

INSTALLATION AND SERVICE MANUAL

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

MODELS. 2 & 4 Low Profile Linears

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

ISO FM Made in the U.S.A

Cordless Rechargeable Saw Instructions for Use

Light Source User Guide

Operating Instructions August 2013

UNIVERSAL BATTERY CHARGER II

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

Series 1 Examination Lamp. Series 2 Examination- and Reading Lamp. Series 3 Reading Lamp. Series 4 Reading Lamp. Series 5 Examination Lamp

UV-AIRE AIR PURIFYING SYSTEM

HID Flashlight - 15 Watt lumens - 90 minute run time battery

LED DayLite WireLess Mini

Installation Instructions Central Battery Units

LED-HL2-CMP LED Headlight System Operation Manual

V4 Cordless Lamp System User Guide

Emergency lighting units EM LED Light Engines

Slimax LED Curing Light System

25W Explosion Proof LED Light VAC or 11-25V AC/DC - Pedestal Mount - 100' Cord w/ EPP Cap

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

V3700UK OWNER S GUIDE.

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

LED DayLite Micro. User Guide Ver

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

XeVision XeRay XV-LX50 HID Searchlight

Class I Division 2 LED Pivoting Light - 4 foot 3 lamp - LED Oil Rig Fluorescent Replacement

Language specific user manuals are available on

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Service Instructions. DL-1-A Dental Vibrator

150W Explosion Proof LED Light Tower Lumens V AC/DC - Trailer Hitch Mounted

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

LED HANDHELD SLIT LAMP

96W Colored LED Light Bar - Completely Submersible 'L X 200'W Spot VDC Lumens

coop erat ive Flood Lights 50W Flood Light GLC-ASFL-50W-1 PERFORMANCE LED Chip Beam Angle 70 Lumen Maintenance Power Factor EMI ENVIRONMENTAL

Operation Manual. TX40 and CX40

sunnex DISTRIBUTOR TASK OFFERING CATALOG

XENON 300 LIGHT SOURCE

20V 1.5Ah LITHIUM-ION BATTERY

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

LED Headlight User s Manual

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

Intrinsically Safe Flashlight - Rechargeable LED Flashlight with Spot and Flood Beams

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

portable ac/dc suction pump USER S MANUAL ITEM # 18605

ESCORT LC Pump. Instruction Manual WARNING

OutdoorXUPS-600AHV-8364

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

EX Series User Manual

Universal Battery Charger II.

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

60V RECHARGEABLE LITHIUM-ION BATTERY

Fiber Optic Illuminator. Model 21AC Model 21DC

##CFG BWOP Manuals## 24v Emergency Power Unit Installation & Instructions for Use

CeraLux Lamp Module Assembly Instructions

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

31 Watt Low Voltage LED Fixture for Industrial Lighting - Adjustable Trunnion U-Bracket Mount

LED OPERATORY LIGHT Instructions For Use

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

SurePower Battery Pack Guide

TABLE OF CONTENTS 1. SHIPPING CARTON & CONTENTS INTRODUCTION PF SERIES MRI SPECIFICATIONS ASSEMBLY INSTRUCTIONS...

MP V 8A Electronic Smart Charger. Instruction and Information Manual

TITAN Tx350 Model Tx350-A Xenon Illuminator with Manual Dimming Operation Manual

IMPORTANT: SAFETY INSTRUCTIONS

Laerdal Compact Suction Unit 4

Professional Wireless Products

96W Ultraviolet LED Light Bar - Submersible Underwater Light 'L X 200'W Spot VDC

LED Twister II. User manual UK Version 1.0

UCA ADJUSTABLE ANGLE MULTI COLOR TEMPERATURE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

DC POWER SUPPLY ALIMENTATION C.C.

20V Lithium-Ion Battery Pack

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Transcription:

IsoLED FLEX I CUSTOMER MANUAL 1

IsoLED FLEX I CUSTOMER MANUAL Document No. OM-1221-C Version 1.0 AUGUST 14, 2015 ISOLUX LLC 1045 Collier Center Way Suite 6 Naples FL, 34110 2

TABLE OF CONTENT TABLE OF CONTENT...3 1. REVISION HISTORY...4 2. LABELS...4 2.1 LABEL, NAMEPLATE...4 2.2 LABEL, WARNING...5 3. SYMBOLS...6 4. Introduction...8 5. Functional Description...9 6. Theory of Operation... 12 7. Flex I Performance... 12 8. Battery Charger Specifications... 12 9. Operating Instructions... 15 10. Cleaning Instructions... 16 11. Care and Maintenance... 16 12. Packing and unpacking... 16 12.1 Transportation Label... 17 12.2 Unpacking... 18 13. TROUBLESHOOTING... 18 14. Disposal of Waste Products... 18 3

1. REVISION HISTORY Version Release Date Comments 0.1 11/13/2013 Rough Draft 1.0 08/14/2015 Final Document 2. LABELS 2.1 LABEL, NAMEPLATE LED PORTABLE DIAGNOSTIC LAMP MODEL No.: IsoLED Flex I S/N: XXXXX ISOLUX LLC NAPLES, FL. USA INPUT 16.8 VDC @ 0.9 A 15.1 watts max. OUTPUT Optical Output: >35 Klux @ 12 in. Operating Temp.: 0 to 50 C Storage Temp.: -10 to 60 C BATTERY OPERATED 14.4 VDC: > 9 hours operation @ full intensity Material: 1. Transparent Gloss Polyester with permanent Acrylic Adhesive backing. 2. Background color: Transparent. 3.Lettering and Markings: Black. 4. Size: 3.00 by 1.00 4

2.2 LABEL, WARNING Read accompanying documents Transport should only be undertaken with the light head facing directly down with the gooseneck arm bent over as close as possible to itself. Transport ne doit être entrepris avec la tête de lampe directement face vers le bas avec le col de cygne bras pliés au plus près possible de lui-même ISOLUX LLC Naples, FL. USA Material: 1. Transparent Gloss Polyester with permanent Acrylic Adhesive backing. 2. Background color: Transparent. 3. Lettering and Markings: Black. 4. Size: 3.00 by 1.50 5

Notes: 1. Unit is designed with protection against electric shock as per the requirements of IEC 60601 2. Equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide. 3. SYMBOLS QPS LISTING MARKING Caution Protective Earth Ground Read accompanying documents 6

Temperature Range: Operating, Storage and Transportation Relative Humidity Range This Side Up Keep Dry Recycle 7

4. Introduction The IsoLED Flex I is a portable, battery operated Exam / Diagnostic lamp ideal for use in the following environments: OB/GYN FAMILY PRACTICE DERMATOLOGY EMERGENCY ROOMS OUTPATIENT FACILITIES LABOR 7 DELIVERY SETTINGS URGENT CARE CENTERS It s portability without the encumbrance of a power cord and the flexibility of its gooseneck allows it to be used anywhere at any position. Its high efficiency design allows for reduced energy consumption and reduced cost of ownership, while its 50,000 hour of LED life provides for a free maintenance device with and end life of around 20 years. Its design follows and surpass the Energy Star Requirements Its CRI of 95 rating produces a very high color rendition for accurate diagnosis; and the life of the LEDs used is kept high by limiting their junction temperature to less than 45 º C for a better than 50,000 hours of operation; while its meager power consumption of 4.3 watts provides for a very efficient and eco-friendly lamp. Furthermore, the use of sharp cutoff optics allows for a well defined spot with a very small Halo effect and good depth of field. The IsoLED Flex I lamp has been designed taking into account all of the different disciplines that makes up for true latest-state-of-the-art LED technologies: Efficiency The LED Driver Board has an efficiency of 76 % and delivers 3.6 watts to power the unit s single LED. The battery charger efficiency is greater than 80 % and its Hi-Pot insulation is >4,000 VAC for 1 minute. Color Rendition Index Typical CRI of 95 for excellent color rendition. 8

llumination The LED optical efficiency plus the optical efficacy of the secondary optics used, provides > 35,000 lux at 12 inches from source, for a Figure of Merit of 8100 lux/watt Thermal The thermal design has been designed around keeping the Junction temperature of the LED lower than 45 º C (for a 27 º C ambient). This ensures the long life of 50,000 hours (70% of max.) and the minimum decrease of the lamp s illuminance vs. time. 5. Functional Description. The unit s front panel and interconnect diagram are depicted in Figure 5.1. The Control Box diagram is depicted in Figure 5.2. The Flex I unit consists of three (3) major components: The Control Box, The Headlight Assembly and the Battery Charger. All of the electronics are housed in the Control Box including the unit s two controls and two displays located at its front panel: Brightness Control: Controls the light intensity from 3 % to 100 %. Power ON Switch: Turns the unit on or off. Power ON indicator: Shows unit s status, on or off. Low Battery Indicator: Warns the operator that the battery is low The Control Box houses the 4-cell Battery Pack and the LED Driver. The Headlight Assembly contains the unit s Light Engine, composed of the single LED, heat sink, optics, 10 K thermistor and Metal Clad PC Board. The unit s battery charger is a Medical Approved unit certified to UL60601-1, EN60950, EN60601-1, EN60335-2-29 and is also certified to the following EMC Standards: EN60601-1-2, EN61000-6-3 (Emission) and EN61000-6-1 (Immunity). See Figure 8.1: Battery Charger Specifications. 9

BRIGHTNESS CONTROL BRIGHTNESS LOW BATTERY INDICATOR LO BATT. l O POWER ON POWER ON SWITCH POWER ON INDICATOR Battery Charger CONTROL BOX CONTROL BOX - Battery Pack - LED Driver GOOSENECK HEADLIGHT - Heat sink - LED - Optics Figure 5.1 IsoLED Flex I Interconnect Diagram 10

FRONT PANEL Power On Switch Brightness Control Power On Indicator Low Battery Indicator From Battery Charger 4-Cell Battery Pack LED DRIVER To Headlight UNIT'S CONTROL BOX Figure 5.2 Control Box Diagram NOTES: 1. The Battery Charger is only used when the unit is charging and non-operative. 2. The maximum voltage in the unit is 14.8 VDC. 3. There is no connection to any AC power source during unit s operation 11

6. Theory of Operation The Control Box houses the 4-Cell Battery Pack and the LED Driver Board. The Battery Pack, when low, gets charged when the Battery Charger is connected to the DC Jack located at the back of the Control Box. When the battery pack is fully charged, the battery charger indicator turns from red to green. The battery pack 14.4 VDC powers the LED Driver Board, which in turn, provides the 1.1 amps constant current that drives the unit s single LED. The Brightness Control provides a dimming range from 3 to 100 % of full optical power. The Low Battery Indicator turns from green to red when the battery pack voltage drops below 12 VDC. 7. IsoLED Flex I Performance The unit s performance is depicted in Figure 7.1: Flex I Specifications. 8. Battery Charger Specifications The unit s battery charger is a Medical Approved unit certified to UL60601-1, EN60950, EN60601-1, EN60335-2-29 and is also certified to the following EMC Standards: EN60601-1-2, EN61000-6-3 (Emission) and EN61000-6-1 (Immunity). See Figure 8.1: Battery Charger Specifications. 12

Figure 7.1 Flex 1 Specifications # of LEDs One Warm White LED Color Temperature CRI (Color Rendition Index) Light Intensity @ 12 4000 to 4500 º K 95 Typical > 35, 000 lux Working Distance 12 to 24 Spot Size (Iris control) ½ to 3 ½ LEDs Life Operating Temperature Electrical Power Minimum Operating Time Power Consumption Efficiency > 50,000 Hours -10 º C to +40 º C 14.4 volts Battery Pack (4 x 3.7 cells) rechargeable ion lithium batteries 2.6 A-Hour Capacity 10 hours of continuous operation at maximum light intensity. 4.3 watts Meets Energy Star Guidelines Dimming 3 % to 100 % Controls: Battery Charger, 15.1 watts Universal AC Input Weight - On/Off power switch - Power On green indicator - Low Battery green / red indicator - Brightness Control - UL certified per IEC 60601-1, 1988, 2 nd edition. 12.5 lbs 13

Figure 8.1 Battery Charger Specifications AC Input Voltage Range Universal: 100 to 240 VAC Input Frequency 47 to 63 Hz. Efficiency 80 % Charge Current 0.9 A, ± 5 % Charge Voltage 16.8 ± 0.1 VDC Terminal Charge 0.1 A ± 25 % Output Power Ripple Operating Temperature Insulation Class Insulation Voltage Electrical Safety Approvals EMC Standards Reliability (MIL-GDBK-217F) 15.1 watts < 100 mv p-p -25 C to +40 C Class II 4,000 VAC (primary) / 5,640 VDC (secondary) UL60601 1, EN60950, EN60601-1, EN60335-2-29 EN60601-1-2, EN61000-6-3 (Emissions), EN61000-6-1 (Immunity) MTBF > 250,000 hours at 30 C and full load Dimensions 4 x 1.8 x 1.5 Weight 0.29 lbs 14

9. Operating Instructions The IsoLED Flex I battery operated unit is an ambulatory unit that could be moved to any location by means of its 5 wheel base; in addition, It s extremely flexible arm (gooseneck) allows it to be positioned at any angle and distance from the patient. The operation of the IsoLED Flex I unit is simplicity on itself: - Turn power ON and observe the unit s brightness, turning the brightness control clockwise increases the light intensity. At full brightness, the battery pack will last approximately 10 hours. - Low battery indicator will turn from green to red when the battery voltage has decreased to < 12 VDC. When that happens, move the unit to its charging station and plug the battery charger to its DC jack located at the back of the Control Box. The charging time will be around 3 hours (overnight charge) 15

10. Cleaning Instructions Overall appearance - Check the general aesthetics of the IsoLED Flex I Diagnostics Lamp. The unit should be kept clean and dust free. Clean and dust as necessary. Optical Window - The front lens is made from a UV resistant polycarbonate plastic that has an external hard coating to resist scratching. Clean the lens using glass/plastic cleaner or mild soap and water mix. It is very important to use a clean, soft cloth to avoid any scratching of the lens. Never spray the cleaning fluid directly onto the lens surface, but instead spray into clean cloth and then wipe the lens. Do not expose the unit to excessive moisture. Failure to do so could result in personal injury and/or property damage. 11. Care and Maintenance Unit does not require any special handling. The only maintenance required is to wipe the unit s window with a soft non-lint cloth as required with its use (as needed). Unit should perform to over 50,000 hours with a minimum 70 % degradation of its light output. If unit fails to turn on, send back to factory for repairs. The IsoLED Flex I will give you years of failure free performance and no maintenance cost except for the meager 4.3 watts of power consumed, for a very low cost of ownership. The battery pack, after many recharge cycles (>800) may require replacement. Unit should be sent to Isolux LLC to replace the battery pack. 12. Packing and unpacking The Isolux LLC packing label shows three symbols depicting the environmental ranges of the unit under transportation. The additional four symbols relates to the conditions required for shipping the unit. Special care should be exercised when transporting the Flex I as per warning label on the back of the Control Unit. Unit shall be packaged with the head light and gooseneck bend tightly together and the head light facing down into the bottom of container. 16

12.1 Transportation Label - 10 C to + 70 C TEMPERATURE 10 % to 90 % HUMIDITY 500 hpa - 1060 hpa ATMOSPHERIC PRESSURE FRAGILE THIS SIDE UP KEEP DRY RECYCLE Material: 1. Transparent Gloss Polyester with permanent acrylic adhesive backing. 2. Background color: White 3. Lettering and Markings: Black. 4. Size: 4.00 High by 3.00 Wide 17

12.2 Unpacking WHEN REMOVING PARTS FROM THE SHIPPING CARTONS, BE CAREFUL NOT TO DAMAGE THE COMPONENTS. IMPORTANT: THOROUGHLY CHECK EACH BOX FOR PARTS THAT MAY BE LOCATED IN AREAS THAT CAN BE OVERLOOKED. 13. TROUBLESHOOTING ONLY FACILITY AUTHORIZED MAINTENANCE PERSONNEL SHOULD TROUBLESHOOT THE ISOLED FLEX I SYSTEM. TROUBLESHOOTING BY UNAUTHORIZED PERSONNEL COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE AND COULD VOID WARRANTY. 14. Disposal of Waste Products NO WASTE PRODUCTS ARE PRODUCED BY THE ISOLED FLEX IDIAGNOSTIC LAMP. THE UNIT IS COMPOSED OF NON-TOXIC MATERIALS AND COULD BE DISPOSED OF IN A STANDARD WAY AT THE END OF ITS LIFE. 18