Compact, Safe and Efficient Wireless and Inductive Charging for Plug-In Hybrids and Electric Vehicles

Similar documents
Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Philosophy of Topology and Component Selection for Cost and Performance in Automotive Converters.

INDUCTIVE POWER TRANSFER CHARGING STATION FOR STATIC AND DYNAMIC CHARGE OF ELECTRICAL VEHICLES

Inverter with MPPT and Suppressed Leakage Current

FastInCharge Project: The Concept and Challenges of the Inductive Charging for Plug-in Electric Vehicles

Wireless Power Transfer at VEDECOM. François COLET, Mustapha DEBBOU 77 Rue des Chantiers, Versailles, France

POWER ELECTRONICS & DRIVES

Power Electronics Projects

G2V and V2G operation 20 kw Battery Charger

SPIRO SOLUTIONS PVT LTD POWER ELECTRONICS 1. RENEWABLE ENERGY PROJECT TITLES I. SOLAR ENERGY

Introduction to PrimoveCity. Gaëtan Bilodeau, P.Eng. Business Development - PRIMOVE December 2011

EMC for E-mobility. William Radasky presenting for Jacques Delaballe, IEC TC 69 Chair. APEMC Symposium Seoul, June 2017

Dr. Chris Borroni-Bird, VP, Strategic Development, Qualcomm Technologies Incorporated. Enabling Connected and Electric Vehicles

Fast thyristors. When burning for induction heating solutions.

Visions for Power Electronics in Automotive Applications

1. RENEWABLE ENERGY I.SOLAR ENERGY PROJECT TITLES WE CAN ALSO IMPLEMENT YOUR OWN CONCEPT/IDEA

Steve Hsu, September Alternative Fuels & Vehicles Technology and Trend

Next-Generation Power Electronics Technology with Vehicle Electrification

UNPLUGGED Project: Development of a 50 kw inductive electric vehicle battery charge system

Why Not A Wire? The case for wireless power. Kalyan Siddabattula System Architect bqtesla Wireless Power Solutions TEXAS INSTRUMENTS

EPE 18 ECCE Europe: LIST OF KEYWORDS

KRAV HELAUTOMATISK INDUKTIV LADDNING

Wireless Charger. Inductive charging system for AGVs

Abracon PTM Introduction to AWCCA Series Wireless Charging Coil Assemblies

POWER ELECTRONICS TITLES LeMeniz Infotech

MLCC(Multilayer Ceramic Capacitors) C0G Guide for Resonance Circuits

"Possibilities of wide tolerance +300V residential distribution grids, and +-300V for industrial"

CORPORATE PRESENTATION January, 2014

DVANCED ENERGY SOLUTIONS presents

Optimal Design Methodology for LLC Resonant Converter in Battery Charging Applications Based on Time-Weighted Average Efficiency

The Future of Automotive is Connected, Autonomous, Electric & Wireless

Inductive Power Supply (IPS ) for the Transrapid

E-DRIVE: HIGHLY INTEGRATED AND HIGH EFFICIENT

On-board 22 kw fast charger NLG6 Author: Katja Stengert BRUSA Elektronik AG, Neudorf 14, CH-9466 Sennwald

EMC for E-mobility FR-PM-1-5. Dr. William Radasky presenting for Jacques Delaballe, IEC TC 69 Chair and Jörg Bärenfänger, TC 69 ACEC Representative

Testing Renewable Power Plants on High-Voltage-Ride-Through Capability

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

An Overview of Automotive EMC Standards & Emerging Requirements

Electric cars: Technology

FINHRM FINHRM5 FINHRMA FINHRMAC

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Lecture 1. Introduction to Power Electronics

A Zero-Voltage-Transition Bidirectional DC/DC Converter

Contactless power interface for plug-in electric vehicles in V2G systems

Evolution of the standard CISPR25 to the Ed4. Impact on the design of vehicle component chambers and Frankonia solution EDTC

Power electronics solutions for DC networks

Optocouplers Help Promote Safe, Efficient EV Charging Stations

Surface Mount EMI Filter. Panel Mount EMI Filter

University of Florida Low Cost Solar Driven Desalination

DC-DC CONVERTER. 5.1 Advantages & Disadvantages of DC-DC Converters

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

Packard Electrical/Electronic Architecture Hybrid & Electric Vehicle Portfolio

PHYS 1444 Section 004. Lecture #19. DC Generator Transformer. Generalized Faraday s Law Mutual Inductance Self Inductance. Wednesday, Apr.

SINAMICS GM150 IGCT version

VEHICLE TECHNOLOGIES PROGRAM

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Packard Electrical/Electronic Architecture Hybrid & Electric Vehicle Portfolio

Electric buses Solutions portfolio

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

High Performance Machine Design Considerations

TECHNICAL WHITE PAPER

Low and High Voltage Power Supplies

Automotive EMI Demystified: Part 2 Pursuing an Ideal Power Supply Layout

Indice Pag. 1. Indice

A Practical Guide to Free Energy Devices

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Introduction to Power Electronics - A Tutorial. Burak Ozpineci Power Electronics and Electrical Power Systems Research Center

Testing Energy Storage Systems: From EVs to Utility Grid

Sensors for hybrid power generation system

Benefits of SiC MOSFET technology in powertrain inverter of a Formula E racing car

2007 International Future Energy Challenge Team Members

Dynamic Wireless Charging of Electric Vehicle

HIGH-RELIABILITY POUCH CELL CONNECTION AND COST ASPECTS OF A ROBUST BMS SOLUTION

High-Voltage, High-Current DC- DC Converters Applications and Topologies

Qingdao Zener Electric Co., Ltd

Tools and Techniques for Ensuring Automotive EMC Performance and Reliability

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

Chapter 22: Electric motors and electromagnetic induction

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information

G2V and V2G operation 20 kw Battery Charger

COOPERATIVE PATENT CLASSIFICATION

Vehicle Impact due to E- Mobility 5. Bayerischer Innovationskongress 23.June 2016 Techbase

UNC-Charlotte's Power Engineering Teaching lab

ELECTRIFICATION OF RTG CRANES

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

TORQUE-MOTORS. as Actuators in Intake and Exhaust System. SONCEBOZ Rue Rosselet-Challandes 5 CH-2605 Sonceboz.

VENSYS. Vensys 62 The next Generation of Gearless Wind Turbines goes into Production

Power Electronics. Rajeev Ram, Program Director, ARPA-E

Automotive Power Electronics Roadmap

48 V Traction Drives for the BEV Mass Market

Power Electronics Roadmap. Updated by the Advanced Propulsion Centre in collaboration with and on behalf of the Automotive Council

Advanced Materials The Key to Progress

Power Electronics

MAGNETEC MAGNET-TECHNOLOGIE

High Power Buck-Boost DC/DC Converter for Automotive Powertrain Applications

TECHNICAL DATA SHEET KVA UPS Systemss

BUSINESS DEVELOPMENT SEGMENTS PRESENTATION AUTOMOTIVE APPLICATION,

ADF. Restoring the perfect wave

Design of DC/DC Converters for 42V Automotive Applications

Transcription:

Smart Systems for Safe, Clean and Automated Vehicles Dr. Faical Turki Paul Vahle GmbH & Co. KG Dr. André Körner HELLA KGaA Hueck & Co.

Compact, Safe and Efficient Wireless and Inductive Charging for Plug- In Agenda Objectives and Requirements Energy Transfer Inductive transformer Power electronics Power system integration Additional Functions Foreign object protection Living object protection Positioning assistance RF system interference Summary 2

Objectives Comfort Eliminates plug-in and cables Park positioning support/assistance Security Cable free, minimizing tampering and preventing hazards Elimination of tripping over cables Availability Account for frequent insertions Automatic charging, increasing range Theft prevention Variants Stationary parking, including public, residential and during travel Dynamic en-route while driving 3

Requirements Input Voltage Input Power Power Factor >0.98 Efficiency DC out /AC in >90% Output Voltage Output Current Energy Transfer Direction Operating Frequency 230VAC / 50Hz / 60Hz 3.7kW... later: 7.2kW 22kW 450VDC 10A Uni-directional... Later: Bi-directional 85kHz (140kHz) Air Gap Tolerance Gap Tolerance X/Y Volume (Vehicle Side) Flux Density (general vacinity) 120mm 150mm 210mm Dz<50mm Dx<100mm; Dy<150mm 250mm x 250 mm x 20 mm <6.25µT (ICNIRP) INTERNATIONAL COMMISSION ON NON IONIZING RADIATION PROTECTION 4

Compact, Safe and Efficient Wireless and Inductive Charging for Plug- In Agenda Objectives and Requirements Energy Transfer Inductive transformer Power electronics Power system integration Additional Functions Foreign object protection Living object protection Positioning assistance RF system interference Summary 5

Quelle: WHD Quelle: Duracell Quelle: greenovation.tv Compact, Safe and Efficient Wireless and Inductive Charging for Plug- In Commercial applications of wireless energy transfer High power Industry Low power Inductive cooking Features and Functions Air gap Power Efficiency Frequency Control Field Monitoring Positioning Inductively charged toothbrushes Inductively charged portable devices 6

Compact, Safe and Efficient Wireless and Inductive Charging for Plug- In Evolution of inductive car charging HELLA VAHLE Inductive charging VAHLE licence plate charging GM EV-1 Delco Electronics 7

Air Gap Compact, Safe and Efficient Wireless and Inductive Charging for Plug-In System overview of the energy transfer AC in DC out Rectifier PFC DC- Link HF- Inverter Primary Coil Secondary Coil Rectifier, Filter Rectifier, PFC, DC Link, Inverter Rectifier, Filter Secondary Coil Primary Coil Battery 8

Power Transmission 3.7kW Demonstration Unit Cu Windings: Generate field Ferrite: Field guide Al: Aluminum Shielding Bottom Plate Primary circuit (L,C) Can be driven over with vehicle Sensors for additional function Integrated power electronics [Future] Pick-up Secondary circuit (Rectifier) Small, lightweight Sensors for power transmission and additional functions 9

Unipolar Rectangular (3.7kW) Unipolar rectangular Well known and simple design Large rotational angle tolerance Concentrated central magnetic flux with equal magnetic yoke distribution on outer edges 150 mm air gap 10

Bipolar Solenoid (3.7kW) Bipolar Solenoid Bipolar arrangement with 2 symmetric magnetic poles with opposite flux directions Lower rotational angle tolerance Flux flow in the outer region of the coil requires shielding on vehicle underbody Shielding (80mm air gap shown) Primary Shielding necessary 11

Bipolar Rectangular (3.7kW) Bipolar DD A bipolar field via 2 planar coils in the primary circuit with different flux flow directions Lower rotational angle tolerance No windings on the bottom of the primary coil - Reduced shielding requirements, thus less eddy current losses. Shielding 150 mm air gap 80 mm air gap 150 mm air gap (shown) Good efficiency due to high coupling 12

(7.2kW) (New Development Effort) HELLA/Vahle Recent developments in coil design allows for higher power at comparable size and at the same frequency (85kHz, 140kHz) Almost twice the power density High coupling High compatibility with other coils at different power levels (I.e. 3.6kW, 7.2kW) 80 mm air gap (shown) 13

Coil Efficiency Summary 400VDC, 3kW Planar coil Config #1 Solenoid coil Config #2 Solenoid coil Config #3 Primary Single Layer Unipolar Planar 500mm x 700mm Secondary (vehicle side) Double Layer Bipolar Planar 270mm x 310mm Coil Size [mm] 270 x 310 x13 270 x 310 x 22 185 x 210 x 22 #1 Air gap [mm] 80-160 180-250 120-140 DC-DC Efficiency [%] 86-91 83 93 92 94 L [uh] 205 200 118.2 C [nf] 6.3 6.3 10.9 Primary Single Layer Bipolar Planar 700mm x 500mm Secondary (vehicle side) Bipolar Solenoid 270mm x 310mm #2 Primary Single Layer Bipolar Planar 700mm x 500mm Secondary (vehicle side) Bipolar Solenoid 185mm x 210mm #3 14

Inductive resonant energy transfer Series-Series Resonant Circuit Preferred Topology Parallel-Parallel Resonant Circuit Hybrid Resonant Circuit Large air gap results in high leakage inductance Reactive power compensation by means of C leads to resonant circuit. Series Series Transmission Behavior: Gyrator I R =U WR *R / X 2 15

Power Electronics Uni-directional topology Wireless Interface Air Gap Rectifier PFC DC- Link HF- Inverter Primary Coil Secondary Coil Rectifier, Filter + No voltage converter necessary in vehicle Rectifier, Filter, Current/Voltage Measurements 16

Power Electronics Inverter Switching Strategy Free-wheel + Free-wheel Soft switching is maintained throughout the load operating region Zero Current Switching (ZCS) [IGBT] Zero Volt Switching (ZVS) [MOSFET s] Inverter operates at the resonant frequency which varies with: Coupling factor (k) X / Y / Z positioning variation Compensation capacitance (temperature affects) Output Voltage / Current is regulated by pulse skipping in a time symmetric fashion depending on load conditions Half cycles Reduces output ripple Whole cycles 17

Efficiency Battery State of Charge Efficiency DC out /AC in η>90% During constant current charging Until about 90% SOC Efficiency DCout / ACin of inductive charging is only slightly lower than that of conductive charging 18

Power Electronics Bi-directional topology (Charging or Grid Support) Bridgeless PFC DC/AC Inverter Charging Mode Rectifier Single stage DC/AC Inverter & PFC Rectifier Grid Support Mode DC/AC Inverter 19

Compact, Safe and Efficient Wireless and Inductive Charging for Plug- In Agenda Objectives and Requirements Energy Transfer Inductive transformer Power electronics Power system integration Additional Functions Foreign object protection Living object protection Positioning assistance RF system interference Summary 20

Foreign Object Monitoring (FOD) - Guidelines VDE-AR-E 2122-4-2 1. Function region 1 and transition region 2 a) Heating @40 C T<80 C (metallic Obj) T<90 C (non-metallic Obj) b) Inflammation is not permitted 3 4 2. Transition - and public area Personal protection as ICNIRP guideline, that is, much safer than German 26 BlmSchV Compact design = High flux density Eddy currents in metallic objects leads to heat / inflammation; required detection (FOD = Foreign Objects Detection). Compliance permitted for persons flux density (6.25 μt) in the outdoor area is safe; under the vehicle detection of organisms (LOD) LOD / FPS: interruption of energy transfer 6.25µT Twenty-sixth regulation Execution of the Federal Pollution Control Act (Decree on electromagnetic fields 26 BlmSchV) (27µT) 21

FOD Thin plastic sheet on top of primary coil, (secondary coil optional) First prototype detects objects on surface 50 cent coin cigarette pack gum wrapper 330 ml beverage can Possible increase of detection distance up to 20 mm for larger objects by optimizing internal structure 2014-012-17 VW 7.FIN 2. Presentation Inductive Battery Charging 3,7kW 22

ICNIRP Limits - simulation Magnetic field simulation analysis: Top view Side view Flux density will be lower than 6.3 µt (colored in dark red) at the borderline of the vehicle 2014-03-04 VW Inductive Battery Charging ICNIRP, Prototypes

Living Object Protection (LOP) Radar approach Test with CW Radar Sensor Integration approach: 2014-012-17 VW 7.FIN 2. Presentation Inductive Battery Charging 3,7kW 24

Positioning assistance Support for the driver to position vehicle in optimal charging x/y position when approaching, 5-30m At close range, ~ 1m at end position With increasing accuracy Communication Directional and distance information in the cluster or at the stationary charger box Virtual top view with guidance Perspective automation ~ Park Assist Approaches Optical / camera systems - Visibility Radio-based systems RFID Power Transformers 25

Field Strength H Compact, Safe and Efficient Wireless and Inductive Charging for Plug-In Radio system compatibility - keyless access and drive authorization Data transmission from the vehicle to the ID transmitter Frequency band f = 125kHz (25kHz, 132kHz...) Receiver Selectivity ID-Transmitter H in dbµa/m Distance from the transmitting antenna 26

Radio system compatibility - keyless access and drive authorization LF data reception disturbance from strong magnetic fields of charging vehicle hinders the charging vehicle and others nearby 27

Summary Based on known technologies in new designs and combination challenging but achievable system Allows comfortable and convenient charging Precondition for the widespread implementation of electric mobility Interoperability between systems and sub-systems of various vehicle and system manufacturers as necessary Compatibility with vehicle radio systems and other required radio systems 28

Industrial Application (Vahle) 29

Industrial Application (Vahle) Logistic (Sorter) Trams & Buses* * cooperation with Bombardier Tool-Machines Clean Rooms Automotive Production since 1998 30

Inductive Power Supply CPS : AGV-Application AGV 3 kw SuperCap chargers in Coburg (Kaeser) 1.5 kw AGV-supply with track guiding sensor in Tubos del Mas / Spain 31

Outlook: Dynamic Charging (Vahle / IAV) Future Challenge: Safe and inexpensive dynamic charging infrastructure 32

Thank you for your attention! Dr.-Ing. Faical Turki Paul Vahle GmbH und Co. KG, Westicker Str. 52, 59174 Kamen faical.turki@vahle.de Tel.: 02307 / 704 271 33

Backup BACKUP SAE INTERNATIONAL

Power Control + Self-sufficient power control in the vehicle - Voltage transformation in vehicle generates losses + No voltage converter necessary in vehicle 35

Inductive Series-Series resonant energy transfer gyrator Z in = XC 1 + XL 1 + XL h *Impedances (X ) referred to primary X L2 + XC 2 + R X Lh + XL 2 + X C2 + R at resonant frequency f n, C 1 and C 2 compensate Ls 1, Ls 2 and L h such that: U WR =380VDC X C1 + XL 1 + XL h = 0 X C2 + XL 2 + XL h = 0 Z in = X Lh 2 R Where: R = 8 π 2 R L The gyrator function transforms the primary referred load impedance R into 1/R times a constant X h 2 at resonant frequency f n 36

Integration into the HV board network Inverter Charger Heater A/C Inverter Charger Distribution box DC/DC 12V 12V Distribution box DC/DC Heater A/C HV battery HV battery EV Hybrid Plug-in Hybrid with inductive charging 37

Keyless entry LF compatibility 70dbµA/m ISO Kessy LF Font View Side View Top View The 70dBμA/m surface with unipolar rectangular WPT includes the keyless entry 70dBμA/m surface. In this flux density no Keyless Entry LF communication is possible WPT 140kHz 38

Keyless entry LF compatibility 100dbµA/m ISO Kessy LF Front View Side View Top View The 100dBµA/m WPT ISO does not completely enclose the Keyless Entry 100dBµA/m ISO Keyless Entry LF Communication is possible, depending on location, frequency, receiver and, if necessary, further measures. WPT 140kHz 39