HCI 434F/444F - Technical Data Sheet

Similar documents
HCI 534E/544E - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

UCI224F - Technical Data Sheet

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

HCI 534C/544C - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet

UCDI224F - Technical Data Sheet

LVI634E - Technical Data Sheet

UCI224C - Technical Data Sheet

UCDI274J - Technical Data Sheet

UCI274H - Technical Data Sheet

HCI634H - Technical Data Sheet

HCI634G - Technical Data Sheet

UCDI224E - Technical Data Sheet

HCI 534E/544E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534C/544C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

UCM274C - Technical Data Sheet

UCM274H - Technical Data Sheet

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

UCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

BCI184J - Technical Data Sheet

UCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

BCI164A - Technical Data Sheet

BCI184H - Technical Data Sheet

UCI274C - Technical Data Sheet Winding 06

HCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

PI144D - Technical Data Sheet

PI144J - Technical Data Sheet

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

HCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

BCI164D - Technical Data Sheet

BCI164B - Technical Data Sheet

HCI634H - Winding 311 and 312. Technical Data Sheet

BCI164C - Technical Data Sheet Winding 06

HCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI736F - Winding 312. Technical Data Sheet

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

HCI634V - Technical Data Sheet

PM734E - Winding 28. Technical Data Sheet APPROVED DOCUMENT

QSL9-G5. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

S5L1D-G4 Wdg Technical Data Sheet

P734H - Technical Data Sheet

This engine has been built to comply with CE certification.

QSK23-G3. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

6BTA5.9-G5. Description. Features rpm (50 Hz Ratings)

S3.8 G6 CoolPac. Description. Features rpm (50 Hz Ratings)

Features. Cylinder Block - Alloy cast iron with removable wet liners.

TAD1641GE VOLVO PENTA GENSET ENGINE

KTA38-G5. Features. Description rpm (50 Hz Ratings)

This engine has been built to co mply with CE certification. Gross Engine Output Net Engine Output Typical Generator Set Output

KTA50-G8. Specification sheet. Features. Description. Codes and standards rpm (50 Hz Ratings)

KTA50-G3. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

Perkins. Perkins. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. 202x76x x68x

Perkins. Perkins. Perkins. 175x68x Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg.

موتور ديزل : Cummins. ژنراتور : Stamford. Standby. Prime KVA KW KVA KW ديزل ژنراتور 1

TAD1344GE VOLVO PENTA GENSET ENGINE

MODEL PG 400 AP. Powered by: GENERATING SET PROFORMANCE 50Hz 60Hz STANDBY RATED POWER

Transcription:

HCI 434F/444F - Technical Data Sheet

SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000, VDE 030, NEMA MG1-32, IEC34, CSA C22.2-100, AS139. Other standards and certifications can be considered on request. VOLTAGE REGULATORS SX440 AVR - STANDARD With this self-excited system the main stator provides power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The SX440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. If 3-phase sensing is required with the self-excited system, the SX421 AVR must be used. SX421 AVR This AVR also operates in a self-excited system. It combines all the features of the SX440 with, additionally, three-phase rms sensing for improved regulation and performance. Over voltage protection is provided via a separate circuit breaker. An engine relief load acceptance feature is built in as standard. MX341 AVR This sophisticated AVR is incorporated into the Stamford Permanent Magnet Generator (PMG) control system. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of seconds. An engine relief load acceptance feature can enable full load to be applied to the generator in a single step. If three-phase sensing is required with the PMG system the MX321 AVR must be used. We recommend three-phase sensing for applications with greatly unbalanced or highly non-linear loads. MX321 AVR The most sophisticated of all our AVRs combines all the features of the MX341 with, additionally, three-phase rms sensing, for improved regulation and performance. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 1th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2. for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2

WINDING 311 CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION ± 0. % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. SX440 SX421 VOLTAGE REGULATION ± 1.0 % ± 0. % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT WILL NOT SUSTAIN A SHORT CIRCUIT INSULATION SYSTEM CLASS H PROTECTION IP23 RATED POWER FACTOR 0.8 STATOR WINDING DOUBLE LAYER LAP WINDING PITCH TWO THIRDS WINDING LEADS 12 STATOR WDG. RESISTANCE 0.0073 Ohms PER PHASE AT 22 C SERIES STAR CONNECTED ROTOR WDG. RESISTANCE 1.37 Ohms at 22 C R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 087G, VDE 087N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.% NON-DISTORTING BALANCED LINEAR LOAD <.0% MAXIMUM OVERSPEED 220 Rev/Min BEARING DRIVE END BALL. 6317 (ISO) BEARING NON-DRIVE END BALL. 6314 (ISO) 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 1160 kg 3 kg 463 kg.4292 kgm 2 177 kg 1 x 87 x 107(cm) 0 1160 kg 3 kg 440 kg.2304 kgm 2 1780 kg 16 x 87 x 107(cm) TELEPHONE INTERFERENCE COOLING AIR THF<2% 0.486 m³/sec 1030 cfm TIF<0 0.80 m³/sec 1240 cfm VOLTAGE SERIES STAR 380/220 400/231 41/240 440/24 416/240 440/24 460/266 480/277 VOLTAGE PARALLEL STAR 190/110 200/11 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/110 230/11 240/120 24/127 240/120 24/127 266/133 277/138 kva BASE RATING FOR REACTANCE VALUES 380 380 380 380 444 46 463 47 Xd DIR. AXIS SYNCHRONOUS 2.9 2.34 2.17 1.93 3.21 2.9 2.74 2.8 X'd DIR. AXIS TRANSIENT 0.17 0.1 0.14 0.12 0.18 0.17 0.1 0.14 X''d DIR. AXIS SUBTRANSIENT 0.12 0.11 0.10 0.09 0.13 0.12 0.11 0.10 Xq QUAD. AXIS REACTANCE 2.23 2.01 1.87 1.66 2.84 2.61 2.42 2.28 X''q QUAD. AXIS SUBTRANSIENT 0.30 0.27 0.2 0.22 0.42 0.39 0.36 0.34 XL LEAKAGE REACTANCE 0.06 0.0 0.0 0.04 0.07 0.06 0.06 0.06 X2 NEGATIVE SEQUENCE 0.21 0.19 0.18 0.16 0.28 0.26 0.24 0.22 X0 ZERO SEQUENCE 0.08 0.08 0.07 0.06 0.10 0.09 0.09 0.08 REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.08s 0.019s 1.7s 0.018s 1/Xd 60 3

0 HCI434F/444F Winding 311 THREE PHASE EFFICIENCY CURVES 4

Winding 311 THREE PHASE EFFICIENCY CURVES 60

Winding 311 Locked Rotor Motor Starting Curve MX 0 SX 30 346V 380V 400V 41V 440V 30 346V 380V 400V 41V 440V 2 2 PER CENT TRANSIENT VOLTAGE DIP. 20 1 10 PER CENT TRANSIENT VOLTAGE DIP. 20 1 10 0 0 200 400 600 800 1000 1200 1400 LOCKED ROTOR kva 0 0 100 200 300 400 00 600 700 800 900 1000 LOCKED ROTOR kva MX 60 SX 30 380V 416V 440V 460V 480V 30 380V 416V 440V 460V 480V 2 2 PER CENT TRANSIENT VOLTAGE DIP. 20 1 10 PER CENT TRANSIENT VOLTAGE DIP. 20 1 10 0 0 200 400 600 800 1000 1200 1400 LOCKED ROTOR kva 0 0 200 400 600 800 1000 1200 LOCKED ROTOR kva 6

0 HCI434F/444F Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 10000 SYMMETRICAL CURRENT (Amps) 1000 ASYMMETRICAL 100 0.001 0.01 0.1 1 10 TIME (secs) Sustained Short Circuit = 1,70 Amps 60 10000 CURRENT (Amps) 1000 SYMMETRICAL ASYMMETRICAL 100 0.001 0.01 0.1 1 10 TIME (secs) Sustained Short Circuit = 2,000 Amps Note 1 Note 2 The following multiplication factors should be The following multiplication factor should be used to convert the used to adjust the values from curve between values calculated in accordance with NOTE 1 to those applicable time 0.001 seconds and the minimum current to the various types of short circuit : point in respect of nominal operating voltage : 0 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v X 1.00 416v X 1.00 Minimum x 1.00 x 1.80 x 3.20 400v X 1.0 440v X 1.06 Sustained x 1.00 x 1.0 x 2.0 41v X 1.09 460v X 1.10 Max. sustained duration 10 sec. sec. 2 sec. 440v X 1.16 480v X 1.1 All other times are unchanged Note 3 The sustained current value is constant irrespective of voltage level Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732 7

Winding 311 / 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 10/40 C Cont. H - 12/40 C Standby - 10/40 C Standby - 163/27 C 0 Series Star (V) 380 400 41 440 380 400 41 440 380 400 41 440 380 400 41 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 24 220 230 240 24 220 230 240 24 220 230 240 24 kva 30 30 30 30 380 380 380 380 390 390 390 390 404 404 404 404 kw 280 280 280 280 304 304 304 304 312 312 312 312 323 323 323 323 Efficiency (%) 93.8 94.0 94.1 94.2 93.4 93.7 93.8 94.0 93.3 93. 93.7 93.9 93.1 93.4 93. 93.7 kw Input 299 298 298 297 32 324 324 323 334 334 333 332 347 346 346 34 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Delta (V) 240 24 266 277 240 24 266 277 240 24 266 277 240 24 266 277 kva 40 420 42 438 444 46 463 47 47 483 488 00 488 00 06 19 kw 324 336 340 30 3 36 370 380 380 386 390 400 390 400 40 41 Efficiency (%) 93.9 94.0 94.1 94.1 93. 93.7 93.8 93.9 93.2 93.4 93.6 93.7 93.0 93.2 93.4 93. kw Input 34 37 361 372 380 389 39 40 408 414 417 427 420 429 433 444 DIMENSIONS 2002 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. PO Box 17 Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 Website: www.newage-avkseg.com TD_HCI4F.GB_08.02_01_GB