Wiring Diagrams (Including Accessories) (50/60 Hz)

Similar documents
Wiring Diagrams DIAGRAM INDEX

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Installation Instructions

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

30GX AIR-COOLED LIQUID CHILLER

Product Data. 38AUZ/D 50 Hz Commercial Split Systems Air Conditioning Condensing Units 18.3 kw to 59.2 kw FEATURES/BENEFITS

30GX AIR-COOLED LIQUID CHILLER

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Installation Instructions

Installation Instructions

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Installation Instructions

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

Engineering Data Book

ARUF Series Multi-Position

Installation and Start-Up Instructions

Eclipse 2000 Service Parts

Engineering Data Book

List price 2012 USD A Service manual, CA-UK B Service manual, CIM5-UK C Service manual, CIM6-UK 29.

Starcool Reefer Parts Service Manual, CIM6, Spare part catalog Short Form manual, CIM6, ES. Back plate, evaporator

Installation Instructions

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Installation Instructions

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Installation Instructions

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

Installation Instructions

Installation Instructions

Parts List, Charging Chart, Wiring Diagram

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

CAUTION. SMALL ROOFTOP UNITS ACCESSORY ELECTRIC HEATER AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to15TONS TABLE OF CONTENTS !

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

TON KW 60HZ

Q7RE Series Single Packaged Heat Pump, Single Phase

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Parts List, Tech Labels, Wiring Diagrams

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

J1 Plug Pin Identification

Parts List, Charging Chart, Wiring Diagrams

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

CAS. Product Specifications

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications

ELECTRICAL SYSTEM RP-7

Replacement Parts List

Engineering Data Book

WIRING DIAGRAM SYMBOLS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

ZHA/ZHB SERIES WARNING

MCU/MCU+ 550(22) & 550(23) SERIES CONDENSING UNITS (Metal Lid)

Typical Applications. Horizontal Installation

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

Parts List, Charging Chart, Wiring Diagrams

FMV156DBF FMV156DCG FMV156DQF FMV156DSF

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

Installation Instructions

Predator Model Number Nomenclature

TANK LIDS, REAR STEP AND WHEELS

GENERAL ELECTRIC FAN COIL UNITS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MARINE / INDUSTRIAL SINGLE PACKAGE COOLING UNIT. Marine Systems 90MA/MU SERIES 3. CARRIER CORPORATION RevC

Q5RD Series Single Packaged Heat Pump, Single Phase

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

Prodigy Eclipse 600, 800, 1000 Service Parts

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

EDN & ESN SERIES PRODUCT DATA BOOK. Capacity: 12,000 to 72,000 BTU/HR CONCEALED DUCTABLE SPLIT SYSTEMS

Installation Instructions

Transcription:

UNIT 38AKS 028-044 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/230-3-60 460-3-60 575-3-60 230-3-50 346-3-50 380-3-60 400-3-50 Typical Field Wiring Electronic Programmable Thermostat, Liquid Line Solenoid Valves, and Power................ Fig. 5 Time Delay Relay Wiring............................. Fig. 6 Hot Gas Bypass Wiring.............................. Fig. 7 Motormaster Head Pressure Control Wiring........ Fig. 10,11,12 NOTE: Italics denote 60 Hz export units (not for sale in USA). Wiring Diagrams (Including Accessories) 028-044 (50/60 Hz) WIRING DIAGRAM INDEX SCHEMATIC DIAGRAM FIG. 38AKS028-044 Air-Cooled Condensing Units 50/60 Hz COMPONENT ARRANGEMENT FIG. LABEL DIAGRAM NO. 1 2 38AK501477 3 4 38AK501475 SAFETY CONSIDERATIONS " # " " $ " $ <6<*%8* '5*= 54>48: OPERATION +38%4;%? 7 () Control Module (CM) % & ' # ( ) % *+, -./ 012, % *+ % 3' ( 4 3' ( *+ % *+ % *+ %, % *+ 53' 53' *+ % *+ % 53' *+ %, 63' *+ Bypass Relay (BPR) 4 738 & ' # ( ) % 738 ( 63' % 738 & Time-Delay Relay (TDR) (Standard on 230, 346-3-50) % 9 % 9 :3 ; :3 ## *8 *9 4 9 *94 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 PC 111 Catalog No. 533-839 Printed in U.S.A. Form 38AKS-1W Pg 1 7-00 Replaces: New Tab 3a

Sequence of Operation 9 *+ @ -(019 9 4 @ % (A/ 92.( 3 # @ @B4='/)) B/ # (A2 * 4 9 ( ( % % 738 63' 63' ( 63' (, *+ & 4 *+ % C 738 % % % *+ &, : D<;<846 E # 9, % /A< /A< 4 /A<@ (/B0(@/ )// )A/ :,2, )A/ : )A/ LEGEND (Fig. 1-5) AFS ATS BPR C CB CH CM CMR COMP CR EQUIP FC FCPS FM FU GND HPS IFC LLSV LPS NEC Airflow Switch Air Temperature Switch Bypass Relay Contactor, Compressor Circuit Breaker Crankcase Heater Control Module Control Module Relay Compressor Control Relay Equipment Fan Contactor Fan Cycling Pressure Switch Fan Motor Fuse Ground High-Pressure Switch Indoor Fan Contactor Liquid Line Solenoid Valve Low-Pressure Switch National Electrical Code OPS TB TC TDR TRAN Oil Pressure Switch Terminal Block Thermostat, Cooling Time-Delay Relay Transformer Terminal Block Connection Marked Terminal Unmarked Terminal Marked Splice Unmarked Splice Factory Wiring Field Control Wiring Field Power Wiring Indicates common potential. (Does not represent wiring.) (

Fig. 1 Wiring Schematic 38AKS 208/230-3-60, 460-3-60, 575-3-60 @

Fig. 2 Component Arrangement 38AKS 208/230-3-60, 460-3-60, 575-3-60 NOTES FOR FIG. 1 AND 2 1. Connect TRAN2 to terminal H3 for 230V, H4 for 460V, and H2 for 575V units. If 208/230V units are run with a 208V power supply connect to terminal H2. 2. Connect TRAN1 to ORN lead for 230V, lead for 460V, and WHT lead for 575V units. 3. Compressor & fan motors thermally protected. Three-phase motors protected against primary single phasing conditions. 4. Replacement of original wires must be with Type 90 C wire or its equivalent. 5. Line # indicates location of contacts, #,# signifies single-pole double-throw contacts, # signifies a normally closed contact, # signifies a normally open contact. 6. Factory wiring is in accordance with National Electrical Code (NEC). Field modifications or additions must be in compliance with all applicable codes. 7. Wiring for field power supply must be rated 60 C. Use copper, copper-clad aluminum or aluminum conductors. 8. Terminals G/6, Y2/3 & C/7 of TB3 are for class 2 (24V) field external interlock connections. Class 1 field interlock contacts must have minimum rating of 180 VA, 220V, 50/60 Hz pilot duty. Class 2 field interlock contacts must have minimum rating of 70 VA, 24V, 50/60 Hz pilot duty. 9. Thermostat for standard units: HH01AD042, HH07AT172 & HH07AT174. Subbase: HH93AZ042, HH93AZ176 & HH93AZ180. Thermostat for BDP units: P272-2783 Subbase: P272-1883 & P272-1882. 10. Control module internal illustrated to indicate components orientational sequence. All items illustrated are theoretically represented as internal to component. 11. The factory-supplied LLSV drop control is shipped with the 38AKS unit but field installed at the indoor unit. )

Fig. 3 Wiring Schematic 38AKS 230-3-50, 346-3-50, 380-3-60, 400-3-50,

Fig. 4 Component Arrangement 38AKS 230-3-50, 346-3-50, 380-3-60, 400-3-50 NOTES FOR FIG. 3 AND 4 1. Connect to TRAN1 240V terminal for 400 and 230V units, 200V terminal for 346V units or ORN lead for 380V units. 2. Compressor & fan motors thermally protected. Three phase motors protected against primary single phasing conditions. 3. Replacement of original wires must be with Type 90 C wire or its equivalent. 4. Line # indicates location of contacts, #,# signifies single-pole double-throw contacts, # signifies a normally closed contact, # signifies a normally open contact. 5. Factory wiring is in accordance with National Electrical Code (NEC). Field modifications or additions must be in compliance with all applicable codes. 6. Wiring for field power supply must be rated 60 C. Use copper, copper-clad aluminum or aluminum conductors. 7. Terminals G/6, Y2/3 & C/7 of TB3 are for class 2 (24V) field external interlock connections. Class 1 field interlock contacts must have minimum rating of 180 VA, 220V, 50/60 Hz pilot duty. Class 2 field interlock contacts must have minimum rating of 70 VA, 24V, 50/60 Hz pilot duty. 8. Thermostat: HH01AD042, HH07AT172 & HH07AT174. Subbase: HH93AZ042, HH93AZ176 & HH93AZ180. 9. Control module internal illustrated to indicate components orientational sequence. All items illustrated are theoretically represented as internal to component. 10. The factory-supplied LLSV drop control is shipped with the 38AKS unit but field installed at the indoor unit. 11. On units with 380V, interchange fan motor connections 1 & 3 to ensure counter clockwise fan rotation. A

NOTES: 1. Factory wiring in accordance with the NEC. Any field modifications or additions must be in compliance with all applicable codes. 2. All field interlock contacts must have minimum rating of 180 va pilot duty plus capacity required for field-installed equipment. All field interlock contacts in the 24-v control circuit must have minimum rating of 70 va pilot duty plus capacity required for fieldinstalled equipment. 3. For internal unit wiring, refer to Fig. 1-4 or unit wiring label diagram. Power for TB1 and TB2 follows: UNIT POWER (V-Ph-Hz) TB1 POWER (V-Ph-Hz) TB2 POWER (V-Ph-Hz) 208/230-3-60 460-3-60 24-1-60 115-1-60 575-3-60 380-3-60 24-1-60 220-1-60 230-3-50 346-3-50 24-1-50 220-1-50 400-3-50 4. The following components are not located in the 38AKS unit control box: LLSV1, LLSV2, field control thermostat, AFS, alarm shut-off switch, and alarm or light. Fig. 5 Typical Field Wiring Electronic Arrangement Thermostat, Liquid-Line Solenoid Valves, and Power 2

Field-Installed Accessories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ig. 6 Time Delay Relay Wiring TB2 HGR HOT GAS BYPASS SOLENOID TB2 2 4 6 3 FIELD CONTROL THERMOSTAT TC1 TC2 ON 115-V CIRCUIT AUTO CB1 115V 24-V CIRCUIT LEGEND CB Circuit Breaker HGR Hot Gas Relay LLSV Liquid Line Solenoid Valve TB Terminal Board TC Thermostat, Cooling CB2 24V R Y1 Y2 W1 W2 G C X LLSV2 HGR TB3 Fig. 7 Hot Gas Bypass Control Wiring Schematics B

; A/ 5,/ 5 ',/ 5 + * 4 < 9 : & % C % ( 8 #+9 9 # B & @ : #+9 C & #+9 ) 8 #+9 # ' 9A, 3 #+9 A #+9 ' @ 2 7 @ B + ' # 3 ' #. % ' #. Fig. 8 Fan Motor Locations. * (( #*9 ' # 9/ 8 %) C & * 9/ %9 %, C & ' # 9/ (/B0(@/F # 99 )A/,2,F 99 8 %B C & * 9( 8 #+9 (@ #*7 (@ #*7 & % (@ #*7 % C 9@ + + & $ ) $ ) 9/ % 9) * (9 #*9 + $ ' # 9/ 8 + 39 C & $ ' # 9/ 8 C & 7 NOTES: 1. Transformer shield is field-supplied (575v transformer part no. HT01AH854 is field-supplied). 2. Exact mounting locations on divider panel for capacitor, Motormaster controller, and transformer are at discretion of installer. There are no wires or obstructions on reverse side of divider panel to interfere with mounting screws. Fig. 9 Mounting Motormaster Control Capacitor, and 460-V or 575-V Transformer 9, # )A/,2,,2, 5%/945B,)? + ' #. : * (( #*9 ' # 99 * (9 #*9 ' # 99 8 8 ' # 99 ' #..

SENSOR RED MOTORMASTER CONTROLLER FU1 FCI 11 21 P1 OR PURPLE FM1 12 13 22 23 T8 OR RED T4 OR T5 OR BLACK T1 OR E GRN- FC2 11 21 RED 1 12 22 BRN 2 FM2 13 23 FC3 11 21 ORN PNK 3 1 GRN- LEGEND FC Fan Contactor FM Fan Motor FU Fuse 2 12 22 VIO 3 13 23 GRA Fig. 10 Motormaster Controller Wiring; 38AKS 208/230-Volt Units FM3 (38AKS044 ONLY) GRN- SENSOR RED MOTORMASTER CONTROLLER FCI 11 21 12 22 13 23 460,575V 230V P1 OR PURPLE T8 OR RED T4 OR FM1 T5 OR BLACK T1 OR E GRN- FC2 11 21 RED 1 12 22 BRN 2 FM2 13 23 FC3 11 21 ORN PNK 3 1 GRN- LEGEND FC Fan Contactor FM Fan Motor 12 22 13 23 VIO GRA Fig. 11 Motormaster Controller Wiring; 38AKS 460 and 575-Volt Units 2 3 FM3 (38AKS044 ONLY) GRN- 9/

9A 8 < ' # 9( 92 8 ' % 5 9B ' @B4='/)) $ ))/ ' # 9@ ' # 9) 9. * & & (/ 3 (9 8 & Fig. 12 Location of Propeller on Motor Shaft from Outside of Orifice Ring Fig. 13 Sensor Installation HEADER END 38AKS028 HEADER END 38AKS034 HEADER END 38AKS044 Fig. 14 Motormaster Controller Sensor Locations on Condenser Coil Header Ends, 38AKS Units 99

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - MOUNTING TEMPLATE FOR MOTORMASTER CONTROL 9@

Copyright 2000 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 PC 111 Catalog No. 533-839 Printed in U.S.A. Form 38AKS-1W Pg 16 7-00 Replaces: New Tab 3a