AP312HP Gear Pumps. Single and multiple cast iron gear pumps. Reference: 200-P EN-01 1/54. Issue:

Similar documents
AP250HP Gear Pumps. Single and multiple cast iron gear pumps. Reference: 200-P EN-01 1/46. Issue:

AP212HP Cast Iron Gear Pumps

AP212 Gear Pumps. Standard and Low Noise series. Reference: 200-P EN-03 1/60. Issue:

Gear Pumps - AP05. Reference: 200-P EN-05 1/26. Issue:

APM212 Gear Motors, including Fan Drive Gear Motors

Monoblock Directional Control Valve HDM11S/3PQ

External Gear Pumps Series F

External Gear Pumps Series F

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

GP PUMP SIZE GP1 GP2 GP3 Displacement range cm 3 /rev clockwise, anticlockwise or reversible (seen from the shaft side)

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

The new Marzocchi Low noise and Low ripple gear pump

External gear pump Series G

INTRODUCTION XV-0P XV-1P XV-2P XV-3P. Summary: Displacements - Pressures - Speeds XV-0P XV-1P XV-2P XV-3P

Variable displacement axial piston pumps,

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P US-10 1/18. Issue:

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P EN-10 1/16. Issue:

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

External gear pump Series G

External Gear Pumps Series F

The new Marzocchi Low - noise and Low - ripple gear pump ELI2 series up to 35 cm 3 /rev

Variable displacement axial piston pumps,

MOTOR SCM M2

Group 1 Gear Pumps Technical Information General Information

SCM M2. Other advantages:

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

1.3 HIGH PRESSURE SERIES

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

6.3 SIZE 2. Ordering Code External Gear Pump

Internal Gear Unit. for motor/pump service Series QXM. Reference: 100-P EN-07 1/16. Issue:

Hydraulic gear pumps and motors

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

MOTOR SCM ISO

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Veljan Gear Pumps. 'B' Series Features:

3PE. Aluminium gear pumps. Technical Catalogue E IM03

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions - Fire resistent fluid Page 4 - Features

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

Petrone Oleodinamica s.r.l.

High Pressure Internal Gear Pumps Series QX

Internal Gear Pumps. Series QX. Reference: 100-P E-10 1/32. Issue:

External Gear Pumps Series N

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

GEAR PUMPS DIMENSIONAL DETAILS

US version. Drain connection

Series

TABLE OF CONTENTS INTRODUCTION GROUP OP GROUP 1P GROUP 2P GROUP 3P GROUP OP GROUP 1P GROUP 2P...

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Gerotor pump, fixed displacement volume

Catalog PowrFlowTM PVX Vane Pumps

2.4 HEAVY DUTY SERIES

3.5PC. Aluminium gear pumps. Technical Catalogue E IM04

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Hydraulic Pump Series VP1 Variable Displacement

CAST IRON GEAR PUMPS AND MOTORS Cascade Group 3 l Technical Information

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

PowrFlow PVX Vane Pumps

Variable displacement axial piston pumps,

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Radial piston hydraulic motor Hägglunds CAb

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

QHD1 TABLE OF CONTENTS. Gear Pump Catalogue Table of Contents

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

High Pressure Gear Pumps KP 5

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

TMF 500. Fixed Displacement Axial Piston Motor for Open and Closed Loop System MANUFACTURING THE PRODUCTION LINE OF HANSA-TMP

Output flow In l/min at 1500 min

Differential Lock Valve

TPVT 1200 BTB. Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7

Group 1. Gear Pumps Technical Information

PLP Pump (up to 16 cm 3 /r max. 120 bar) PHV Pump (up to 32 cm 3 /r max. 250 bar) PVS Pump (up to 100 cm 3 /r max. 100 bar)

HYDRAULIC OIL PUMPS AND MOTORS PRODUCT CATALOG. Hybel - Hydraulic Oil Pumps and Motors

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 114 / 0814 / E

TMF 600 ( cm³/rev.)

High Pressure Gear Motors KM 5

D SERIES HYDRAULIC PUMP

HYDRAULIC GEAR PUMP JP 10/20/30 SERIES

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

Hydraulic Pump Series F1plus Fixed Displacement

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

4.2 FIXED DISPLACEMENT DOUBLE PUMP

Transcription:

Gear Pumps Single and multiple cast iron gear pumps Reference: 200-P-991239-EN-01 Issue: 11.2017 1/54

Contents Page 1 General information... 3 1.1 External gear pumps components and construction / benefits... 4 1.2 Technical data... 5 1.3 Pressure... 6 1.4 Suction... 6 1.5 General precaution... 6 1.6 Identifying the rotation direction... 7 1.7 Formulas to determinate main gear pump operate parameters... 8 2 Overview standard pump configurations... 8 2.1 Standard components configuration... 9 3 Single pump customised versions... 22 3.1 Single pump customised versions order example... 23 3.2 Shaft end code... 24 3.3 Front cover/mounting flange... 26 3.4 Single pump dimensions... 29 4 Multiple gear pumps... 32 4.1 Multiple gear pumps: + standard cast iron versions... 32 4.2 Multiple gear pumps: +AP212HP standard cast iron versions... 35 4.3 Multiple gear pumps: +AP212 cast iron + aluminium versions... 39 4.4 Multiple gear pumps: ++AP212HP cast iron versions... 43 4.5 Multiple gear pumps: ++AP212 cast iron + aluminium versions... 47 5 Product identification plate... 51 6 Application form... 52 2/54

1 General information The product range of ucher Hydraulics SpA includes single pumps 05-100-212-212HP-250HP-300-312HP (corresponding with the common group denominations: 05-1-2-2.5-3) and several combinations of double pumps, triple pumps, and so on, that can be assembled together according to versions of displacement, flanging, and auxiliary valves. ucher Hydraulics SpA has supplied a wide range of external gear pumps and motors to industrial and mobile applications since many years. ucher s external gear pumps are widely used in modern hydraulic system to obtain high performances, long life service and low purchase and maintenance costs. Thanks to the positive field experiences recorded on the group 2 (AP212HP) and group 2.5 (AP250HP) cast iron pump and motor series, ucher Hydraulics has completed its product range introducing the new cast iron pump group 3. The new pump has been developed with modern and robust design concepts. Strong 2 pieces structure, big shafts diameter as well as high quality materials, allows to the to reach very high quality and performance levels, in order to fulfill the most innovative types of machines and applications. ucher designed this new pump with support bearings mounted in the cast iron body and covers. Tandem and triple pumps are also available with direct connections between the shafts. is specifically developed for wheel loaders, excavators and telehandlers applications. ucher Hydraulics has so achieved this state of the art by constantly improving its design, control and manufacturing techniques aligned with the latest technological developments, while simultaneously enhancing its Quality System ensuring that every single product offers the same high standards. Main applications and benefits Wheel loader Excavator Telehandler Robust design in compact dimensions Teeth design optimisation oriented to reduce pressure pulsation Reduced noise and vibration Reduced number of components - reduced weight ouble shaft seals - More shaft protection and long life without external leakage HNR seals Wide fluid temperature range admitted High volumetric and mechanical efficiencies Single or multistage possible configurations Strong splined shaft multistage connections AP212 aluminium / AP212HP cast iron rear interface ucher validation method: long life expectancy. 3/54

1.1 External gear pumps components and construction / benefits A C E F G F E A Cast iron front cover: the standard front cover design can be fitted to two different pump interfaces Cast iron main pump body: wide range of displacements obtainable with two different basic bodies both with back cover integrated. Rear ports on request. C HNR seal material instead of NR ouble HNR shaft seals E Strong pressure balance plate instead of aluminium. alancing area and intermediate notches optimised ENEFITS F Large diameter bearings, fitted both in front cover and body G Large number of teeth, tooth profile optimised, larger shaft diameter A Flexibility/smaller number of components A Reduced risk of external leakage A E High efficiencies/pressure limits A E Long life expectancy C Wider temperature range E E G G Lower pressure ripple Noise/vibration reduction E F G Higher load capacity and transmissible torque E F G Low friction and high mechanical efficiency E F G Higher max. pressure limit. The front mounting flange and the body/backcover are made of high strength cast iron to gives thermal stability, resistance to contamination and the strength necessary for persistently high levels of performance and life, needed in demanding heavy duty applications. ody/back cover integrated, larger shaft diameter, large-diameter bearing and bronze trust plate have been optimized to provide heavy duty, high pressure limits, high efficiencies and long life expectancy. Noise and vibration reduction due to the large number of teeth. The bearings are located in the front mounting flange, in the body/back cover and, for multiple pumps, in the body pumps. 4/54

1.2 Technical data Operating fluid temperature range (mineral oil): Recommended fluids Features NR HNR FPM (VITON) -15 / +80 C (peak: -20 / +90 C) -20 / +90 C (peak: -30 / +110 C) -5 / +100 C (peak: -10 / +110 C) hydraulic mineral oil-based Viscosity range: Cleanliness: Recommended Permitted Permitted for starting recommended for operating pressure > 170 bar recommended for operating pressure < 170 bar 20-120 mm 2 /s (cst) up to 700 mm 2 /s (cst) 2000 mm 2 /s (cst) 21/18/15 ISO 4406 22/19/16 ISO 4406 Standard seals material (valves not included) NR + HNR standard ( ISO1629) Extreme working limit values can not be combined Type isplacement P1 Pressure P3 Min speed Max speed** cm 3 /rev Cu.In.P.R. bar P.S.I. bar P.S.I. rpm rpm 40 40.2 2.45 300 4300 320 4600 500 3000 45 45 2.75 300 4300 320 4600 500 3000 54 54.4 3.32 290 4100 310 4400 500 3000 63 63.1 3.85 280 4000 300 4300 500 2500 75 75.3 4.60 240 3400 260 3700 500 2000 **: The max admitted speed is referred to single pump/single inlet configuration. In case of multiple pumps with common suction line, a speed reduction must be considered. IMPORTANT!: The pressure values are referred to unidirectional pumps, single versions only. Please consult ucher Hydraulics if even one of the operating limits indicated in the table (temperature, pressure, rpm) is exceeded, as well as in the case of two or more maximum values at the same time, or for applications with particularly heavy-duty cycles 5/54

1.3 Pressure Pressure levels: P1 = continuous pressure P3 = peak pressure The recommended oil speed in the pressure pipes is: v = 2 to 5 m/s 1.4 Suction The absolute suction pressure must be P in 0.75 bar (11 PSI); therefore, the following must be avoided: - large height differences between pump and tank - long stretches of piping - special features such as: - bends - reductions in diameter - quick couplings - etc. p (bar) 0.05 s P3 P1 t (s) It is also advisable to choose a filter of a suitable size to minimise any pressure drop and to take measures to prevent gradual clogging over time. P out P in (Example 1) (Example 2) M P in P out M 1.5 General precaution In addition to the recommendations regarding fluids, filtration, coupling, etc., we suggest the following: - Always check the rotation direction of the pump's drive shaft; it must be compatible with the rotation direction of the pump itself. - e particularly careful in cleaning and make sure, when connecting the suction and pressure piping, that no chips, rag threads, teflon tape, etc. get into the pump circulation system. - Check the tightness of the suction and pressure fittings, the correct positioning of the O-Ring, and make sure there is no dirt between the flange and the pump body. - The first pump start-up can be facilitated by manually filling the suction piping and the pump itself with oil. To facilitate air bleeding, start the pump with the circuit not pressurised. - To ensure the best heat distribution inside the tank, make sure the return pipe is not too close to the pump's suction piping. The pipings themselves should be below oil tank level to prevent the formation of foam. - o not subject the pumps to operating conditions different from those indicated on section 1.2 ; for extreme operations, always contact our Sales epartment. - In the event of pump painting, do not use solvents or paints that are incompatible with the material of the seals. o not bake paint with excessively high temperatures. o not paint over the product identification plate. 1.5.1 Hydraulic fluid The main function of the fluid used in hydraulic systems is to transfer energy but it performs also other important functions: protect the components from corrosion, lubricate the pump moving parts, remove particles and heat from the system. In order to ensure proper operation and long life of the system it is important to choose the correct hydraulic fluid with proper additives. ucher Hydraulics recommends to use a mineral based oil responding to ISO 6743/4 requirements, only. The system should be operated only with hydraulic oil containing anti-foaming and antioxidant additives. efore using other types of fluid, please contact our Sales ept, since they can cause serious damage to the directional valve components and jeopardize the correct function of the system. Never use fluids different from those indicated in section 1.2 and do not use fluids incompatible with the pump seals (i.e. HNR) 6/54

1.5.2 Filtration In order to ensure proper operation and long life of the pump components it is extremely important to provide a proper and effective filtration of the hydraulic fluid. It is advisable to follow filter manufacturers instruction and recommendations. The fineness of the filter should be selected in order to guarantee that a contamination levels indicated on section 1.2. When the high reliability of the system is an important requirement, a pressure filter must be used. In these cases it is also advisable to use a pressure filter with by-pass and indicator. The size of the return filters must suit the maximum return 1.5.3 irectives and standards Atex Attention: The equipment and protective systems of this catalogue ARE NOT intended for use in potentially explosive atmospheres. Ref: irective 99/92/EC and irective 2014/34/EU. 1.6 Identifying the rotation direction The rotation direction of a gear pump is identified by looking at the pump from the front and with the drive gear turned upwards (see figures below). Pumps with clockwise rotation () have a drive gear which turns clockwise, with the suction port on the left and the pressure port on the right. Pumps with counterclockwise rotation (S) have a drive gear which turns counterclockwise, with the suction port on the flow whereas the size of the pressure filters must suit the maximum pump flow. It is advisable to fit filters with pressure gauge or dirt indicator in order to make it possible to verify the filter condition. Particular attention has to be paid to the cleaning of the machine hydraulic circuit and its components before the first run-in, since the presence of foreign materials could cause damages even if a proper filtration is provided. In order to obtain the best performance of the system we recommend to strictly follow the conditions advised here above, failing which warranty shall be void. - ISO 9001: 2015 / ISO 14001:2015 ucher Hydraulics S.p.A. is certified for research, development and production of directional control valves, gear pumps and motors, power units, electro pumps, cartridge valves and integrated manifolds for hydraulic applications. right and the pressure port on the left. The figure also shows the pressure flow inside the pumps as the oil is transferred from the suction port to the pressure port. Pumps with a unidirectional rotation ( or S) have the denomination AP. Right-hand rotation Left-hand rotation S Suction Pressure Pressure Suction 7/54

1.7 Formulas to determinate main gear pump operate parameters The following parameters are defined: Vc = (cm 3 /rev) pump displacement; n = (rev/min) no. of rpms of the drive shaft; Q = (l/min) flow rate; p = (bar) operating pressure; T = (Nm) drive torque; N = (kw) Absorbed power; p Vc Q T n M N (T, n) v = (%) volumetric efficiency; m = (%) mechanical efficiency; t = (%) total efficiency Q = Vc n η p Vc N = Q p 100000 v T = 1.59 η m 6 η t Example /15 Vc= 40 cm 3 /r n= 1500 r/min p=200 bar η v = 94% η m = 90% η t = 84.6% Q = 40 1500 100000 94= 56.4 l/min. T = 1.59 200 40 90 =141.3 Nm N = 56.4 200 6 84.6 = 22.22 kw 2 Overview standard pump configurations This pumps configuration are considered as standard. 13 teeth S382S S388G S388S 15 teeth S582S S588G S588S 14 teeth S48C2S S48C8G S48C8S Straight keyed Ø 25.4 mm C182S C188G C188S Straight keyed Ø 22.225 mm C282S C288G C288S Tapered 1:8 C81P2P C81P8G Example 13 teeth external spline SAE J 498 13T 16/32 P 41.2 1.62 S3 SAE- 8 SAE FLANGE PORTS J518 (3000 PSI series) 2S S382S In the next pages, front, body/rear cover, and seals materials are listed for each pump series. For ordering purposes, it is enough to outline the complete pump description (for example: /40 S382S). In case of a different configuration request (or a combination of different features, such as port threads, front flange materials, etc.), the description configurator shown in section 3.1 can be easily used. 8/54

2.1 Standard components configuration rive shaft Cast iron flange Cast iron body/back cover Port type 13 teeth external spline SAE J 498 13T 16/32 P Tmax= 270 Nm 15 teeth external spline SAE J 498 15T 16/32 P T max = 460 Nm 41.2 1.62 46 1.81" S3 S5 SAE- 8 SAE FLANGE PORTS J518 (3000 PSI series) 2S 14 teeth external spline SAE J 498 14T 12/24 P T max = 950 Nm 55.6 2.19" S4 SP Ports 8G 46 1.81" Straight keyed Ø 25.4 mm C1 SAE-C 8C 41.2 1.62" SAE threaded ports UNF 8S Straight keyed Ø 22.225 mm C2 47 1.85" European 4 bolts flanged 2P Tapered 1:8 C8 European rectangular 1P SP Ports 8G 9/54

Serie page Serie page Serie page S382S-S582S S388G-S588G S388S-S588S 11 12 13 S48C2S S48C8G S48C8S 14 15 16 C182S C188G C188S 17 18 19 C282S C288G C288S 17 18 19 C81P2P C81P8G 20 21 Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 10/54

AP S382S S582S A S3: 41.2 (1.62 ) S5: 46 (1.81 ) 13.5.53" 174 9.5 Ø14.3 146 6.85".37".56" IA 5.75" Ø101.6 4" IA E 158 6.22" 103.6 4.08" 164.1 6.46" 0-0.05 24.6.97" 135 5.31" * S3: 13 teeth S5: 15 teeth H F Type A Suction Pressure H E F H E F mm inch mm inch mm inch mm inch mm inch mm mm inch mm inch mm inch mm 40 132 5.20 87.8 3.46 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 45 135 5.31 90.8 3.57 26.19 1.03 52.37 2.06 25.4 1 54 140.8 5.54 96.6 3.80 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 35.71 1.40 69.85 2.75 38.1 1.5 M12x 1.75 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 Pump description example: /40_S_S382S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For S3- S5 dimensions see 3.2 11/54

AP S388G S588G A S3: 41.2 (1.62 ) 13.5 S5: 46 (1.81 ).53" Ø14.3 174 146 9.5.56" IA 6.85".37" 5.75" Ø101.6 0-0.05 4" IA 24.6.97" 158 6.22" 103.6 4.08" 164.1 6.46" 135 5.31" * S3: 13 teeth S5: 15 teeth Suction - Pressure Type A Suction Pressure mm inch mm inch SPP SPP 40 132 5.20 87.8 3.46 45 135 5.31 90.8 3.57 54 140.8 5.54 96.6 3.80 1 1/4 SP 1 SP 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 Pump description example: /63 S388G Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For S3- S5 dimensions see 3.2 12/54

AP S388S S588S A 174 6.85" S3: 41.2 (1.62 ) S5: 46 (1.81 ) 41.15 9.5.37" 13.5.53" Ø14.3.56" IA 146 5.75" Ø101.6 4" IA 24.6.97" 158 6.22" 103.6 4.08" 164.1 6.46" 0-0.05 135 5.31" * S3: 13 teeth S5: 15 teeth Suction - Pressure Type A Suction Pressure mm inch mm inch UNF UNF 40 132 5.20 87.8 3.46 45 135 5.31 90.8 3.57 54 140.8 5.54 96.6 3.80 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 1 5/8-12 UNF-2 (SAE20) 1 5/16-12 UNF-2 (SAE16) Pump description example: /63 S388S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For S3- S5 dimensions see 3.2 13/54

AP S48C2S A 213 5.31" S4: 55.6 - (2.19") 12.7.5" 16.5.65" Ø17.5.69" IA 181 7.13" Ø127 5" IA E 158 6.22" 103.6 4.08" 178.6 7.03" 0-0.05 24.6.97" 135 5.31" * S4: 14 teeth H F Type A Suction Pressure H E F H E F mm inch mm inch mm inch mm inch mm inch mm mm inch mm inch mm inc mm 40 135 5.31 90.8 3.57 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 45 138 5.43 93.8 3.69 26.19 1.03 52.37 2.06 25.4 1 54 143.8 5.66 99.6 3.92 63 149.2 5.87 105 4.13 75 156.8 6.17 112.6 4.43 35.71 1.40 69.85 2.75 38.1 1.5 M12x 1.75 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 Pump description example: /40_S_S48C2S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For S4 dimensions see 3.2 14/54

AP S48C8G A 213 5.31" S4: 55.6 - (2.19") 12.7 0.5" 16.5.65" Ø17.5.69" IA 181 7.13" 24.6.97" Ø127 0-0.05 5" IA 158 6.22" 103.6 4.08" 178.6 7.03" 135 5.31" * S4: 14 teeth Suction - Pressure Type A Suction Pressure mm inch mm inch SPP SPP 40 135 5.31 90.8 3.57 45 138 5.43 93.8 3.69 54 143.8 5.66 99.6 3.92 1 1/4 SP 1 SP 63 149.2 5.87 105 4.13 75 156.8 6.17 112.6 4.43 Pump description example: /63 S48C8G Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) For S4 dimensions see 3.2 15/54

AP S48C8S A 213 5.31" S4: 55.6 - (2.19") 12.7.5" 16.5.65" Ø17.5.69" IA 181 7.13" 24.6.97" 0 Ø127-0.05 5" IA 158 6.22" 103.6 4.08" 178.6 7.03" 135 5.31" * S4: 14 teeth Suction - Pressure Type A Suction Pressure mm inch mm inch UNF UNF 40 135 5.31 90.8 3.57 45 138 5.43 93.8 3.69 54 143.8 5.66 99.6 3.92 63 149.2 5.87 105 4.13 75 156.8 6.17 112.6 4.43 1 5/8-12 UNF-2 (SAE20) 1 5/16-12 UNF-2 (SAE16) Pump description example: /63 S48C8S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) For S4 dimensions see 3.2 16/54

AP A C182S C282S 174 6.85" C1: 46 (1.81") C2: 41.2 (1.62") 13.5.53" Ø14.3.56" IA 146 5.75" Ø101.6 0-0.05 4" IA C1: Ø 25.4 (1"IA) C2: Ø 22.225 (.875"IA) 24.6.97" 9.5.37" 135 56 H 5.31" 2.2" E F 158 6.22" 103.6 4.08" * 1"-.998".875 -.874 28.1±0.1 C1 1.10" 25.4-0.01-0.04 6.375 0-0.025.251-250 25 0-0.2 C2.984 -.983 22.225 6.375.251-250 164.1 6.46" 0-0.025 0-0.025 M8 T max= 280 Nm T max= 185 Nm 1/4-28 UNF Type A Suction Pressure H E F H E F mm inch mm inch mm inch mm inch mm inch mm mm inch mm inch mm inch mm 40 132 5.20 87.8 3.46 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 45 135 5.31 90.8 3.57 26.19 1.03 52.37 2.06 25.4 1 54 140.8 5.54 96.6 3.80 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 35.71 1.40 69.85 2.75 38.1 1.5 M12x 1.75 30.17 1.19 58.72 2.31 31.8 1.25 M10x 1.5 Pump description example: /40_S_C182S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For C1- C2 dimensions see 3.2 17/54

AP C188G C288G A 13.5.53" C1: 46 (1.81") Ø14.3 174 C2: 41.2 (1.62") 146.56" IA 6.85" 5.75" 135 5.31" Ø101.6 0-0.05 4" IA C1: Ø 25.4 (1"IA) * 24.6.97" C2: Ø 22.225 (.875"IA) 9.5.37" 56 2.2" 28.1±0.1 C1 1.10" 158 6.22" Suction - Pressure 25.4-0.01-0.04 1"-.998" 6.375 0-0.025.251-250 25 0-0.2 C2.984 -.983 103.6 4.08" 164.1 6.46" 0 22.225-0.025.875 -.874 6.375 0-0.025.251-250 M8 T max= 280 Nm T max= 185 Nm 1/4-28 UNF Type A Suction Pressure mm inch mm inch SPP SPP 40 132 5.20 87.8 3.46 45 135 5.31 90.8 3.57 54 140.8 5.54 96.6 3.80 1 1/4 SP 1 SP 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 Pump description example: /63 C288G Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For C1- C2 dimensions see 3.2 18/54

AP C188S C288S A 174 6.85" C1: 46 (1.81") C2: 41.2 (1.62") 13.5.53" Ø14.3 146.56" IA 5.75" 135 5.31" Ø101.6 0-0.05 4" IA C1: Ø 25.4 (1"IA) 24.6.97" C2: Ø 22.225 (.875"IA) * 9.5.37" 56 2.2" 28.1±0.1 C1 1.10" 158 6.22" Suction - Pressure 25.4-0.01-0.04 1"-.998" 6.375 0-0.025.251-250 25 0-0.2 C2.984 -.983 103.6 4.08" 0 22.225-0.025.875 -.874 6.375 0-0.025.251-250 164.1 6.46" M8 T max= 280 Nm T max= 185 Nm 1/4-28 UNF Type A Suction Pressure mm inch mm inch UNF UNF 40 132 5.20 87.8 3.46 45 135 5.31 90.8 3.57 54 140.8 5.54 96.6 3.80 63 146.2 5.76 102 4.02 75 153.8 6.06 109.6 4.31 1 5/8-12 UNF-2 (SAE20) 1 5/16-12 UNF-2 (SAE16) Pump description example: /63 C288S Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) * For C1- C2 dimensions see 3.2 19/54

AP C81P2P 135 5.31" 22 80+20 Nm 14.5.57" 47 1.85" 32.5 1.28" 5.197" A Ø11.43" IA 124.2 4.89" 98 3.86" Ø 50.8 f8-0.300-0.076 2"IA M14x1.5 24.6.97" 42 1.65" 154.6 6.09" 52.6 2.07" 17.5.69" 4h9-0.03 0.156 -.157 12.15 0-0.15.478 -.472 Ø21.59.85" IA Taper 1:8 * see 3.2 11.2.44" 18.71" d F T max= 230 Nm A Suction Pressure Type mm inch mm inch d F d F 40 45 54 144.2 5.68 100.1 3.94 63 149.63 5.89 105.53 4.15 27 1.06 51 2.00 M10x 1.5 19.78 40 1.56 M8x 1.25 75 157.23 6.19 113.13 4.45 33 1.22 62 2.43 M12x 1.75 27.98 51 2.00 M10x 1.5 Pump description example: /63 C81P2P Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) 20/54

AP C81P8G 135 5.31" 22 80+20 Nm 47 1.85" 32.5 1.28" 5.197" A Ø11.43" IA 124.2 4.89" 98 3.86" Ø 50.8 f8-0.300-0.076 2"IA M14x1.5 24.6.97" 42 1.65" 52.6 2.07" 154.6 6.09" 4h9-0.03 0.156 -.157 12.15 0-0.15.478 -.472 * see 3.2 Ø21.59.85" IA Taper 1:8 17.5.69" 11.2.44" 18.71" Suction-Pressure T max= 230 Nm Type A Suction Pressure mm inch mm inch SPP SPP 40 45 54 144.2 5.68 100.1 3.94 63 149.63 5.89 105.53 4.15 1 1/4 SP 1 SP 75 157.23 6.19 113.13 4.45 Pump description example: /63 C81P8G Pump size isplacement Series Rotation (S= Left-hand rotation, = Right-hand rotation) 21/54

3 Single pump customised versions HNR seal earings alancing plate 2x HNR shaft seal Cast iron front cover alancing plate External gears earings ody/back cover integrated In this section, a single pump can be configured and customized. wide availability of covers, bodies and gears provides great flexibility to pump range and allows several different pump configurations. In order to simplify the selection of the desired pump combination, a 'configurator form' is available and, by filling it out, it will guide you in the pump creation process. 22/54

3.1 Single pump customised versions order example A P 3 1 2 H P / 4 0 - S - S 3 8 8 G A - * Function AP= single gear pump - unidirectional Series 312HP isplacement 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation S = Left-hand rotation = Right-hand rotation Shaft end code see section 3.2 Front cover type see section 3.3.1 Type of ports code see section 3.3.2 Inlet/outlet port size code combination see section 3.3.2 E H F HRE section : Version - Progressive number (omitted) Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 23/54

3.2 Shaft end code A P 3 1 2 H P / 4 0 - S - S 3 41.2 1.62 Shaft end shape Shaft end ordering code Max torque 13 teeth external spline SAE J 498 13T 16/32 P S3 T max = 270 Nm 46 1.81" 15 teeth external spline SAE J 498 15T 16/32 P S5 T max = 460 Nm 55.6 2.19" 14 teeth external spline SAE J 498 14T 12/24 P S4 T max = 950 Nm 46 1.81" Ø25.4 1"IA Straight keyed Ø 25.4 mm - 1 inches C1 T max = 280 Nm 24/54

Shaft end shape Shaft end ordering code Max torque 41.2 1.62" Ø22.225.875"IA Straight keyed Ø 22.225 mm - 0.875 inches C2 T max = 185 Nm 47 1.85" M14x1.5 1:8 Tapered shaft 1:8 C8 T max = 230 Nm 25/54

3.3 Front cover/mounting flange 3.3.1 Front cover type A P 3 1 2 H P / 4 0 - S - S 3 8 Type Shape Cast iron Ordering code SAE- (Ø 101.6 mm - 4 inches) with HNR seals (shaft seals and O-ring) 8 SAE-C (Ø 127 mm - 5 inches) with HNR seals (shaft seals and O-ring) 8C European rectangular (Ø 50.8 mm - 2 inches) with HNR seals (shaft seals and O-ring) 1P SAE- 174 6.85" 146 5.75" 46.5 1.83" 9.5.37" SAE-C 213 8.39" 181 7.13" 49.5 1.95" 12.7.5" 103.6 4.08" Ø101.6 4" IA 164.1 6.46" 103.6 4.08" Ø127 5" IA 178.6 7.03" European Ø11.43" IA 124.2 4.89" 50 1.97" 5.20" 154.6 6.09" 101.8 42 4.01" 1.65" Ø50.8 2" IA 154.4 6.08" 98 3.86" 26/54

3.3.2 Port types A P 3 1 2 H P / 4 0 - S - S 3 8 8 G A Port type (SAE-, SAE-C, EU) Ordering code isplacement imension (mm - inches) Suction Pressure code SP ports 8G 40-45-54 63-75 1 1/4 SP 1 SP A 1 1/4 SP 1 SP 20.78" 0.5.02" 160+10 Nm 18.71" 0.5.02" 120+10 Nm Ø38 1.50" IA 1 1/4 SP Ø55 2.17" Ø30 1.18" IA 1 SP Ø42 1.65" IA SECTION - SECTION - IMPORTANT!: Tightening torques depends on several different factors including lubrication, coating and surfaces finish. The fitting manufacturer shall be consulted. In the interest of safety, only fittings with STRAIGHT THREA ENS should be used (e.g. IN3852). Fittings with TAPERE THREA ENS (e.g. IN 3852 form C) should never be used, as they can cause deformation and cracks in the valve body. Our warranty conditions will not be valid in case tapered fittings are used. The work port adaptors have to be fastened respecting the tightening torque values indicated. 27/54

Port type (SAE-, SAE-C, EU) Ordering code isplacement imension (mm - inches) Suction Pressure code SAE threaded ports UNF 8S 40-45-54-63-75 1 5/8-12 UNF-2 (SAE20) 1 5/16-12 UNF-2 (SAE16) A 1 5/8-12 UNF-2 (SAE20) 170+10 Nm 24.94" 20.79" 0.5.02" 1 5/8-12 UNF-2 (SAE 20) 1 5/16 12 UNF-2 (SAE16) 160+10 Nm 24.94" 20.79" 0.5.02" Ø38 1.50"IA Ø60 2.36"IA Ø30 1.18"IA Ø50 1.97"IA 1 5/16-12 UNF-2 (SAE 16) SECTION - SECTION - Port type (SAE-, SAE-C, EU) Ordering code isplacement imension (mm - inches) Suction Pressure code d F European 4 bolts flanged 2P 54-63 75 27-1.06 (d) 51-2.00 () M10x1.5 (F) 33-1.22 (d) 62-2.43 () M12x1.75 (F) 19-0.78 (d) 40-1.56 () M8x1.25 (F) 27-1.06 (d) 51-2.00 () M10x1.5 (F) A 33/62 27/51 19/40 Ø62 2.4" IA E 25+5 Nm 37 1.46" 22.87" 18.71" M12x1.75-6H n 4 bolts Ø51 2.01" IA E 37 69" 22.87" 18.71" Ø40 1.57" IA E Ø33 1.30" IA Ø27 1.06" IA 20+5 Nm M10X1.5-6H n 4 bolts 37.69" 21.83" 17.67" Ø19 75" IA 20+5 Nm M8X1.5-6H n 4 bolts E SECTION E-E E SECTION E-E E SECTION E-E IMPORTANT!: Tightening torques depends on several different factors including lubrication, coating and surfaces finish. The fitting manufacturer shall be consulted. 28/54

Port type These flanges are available for SAE- and SAE-C body type, only. NOT available for European version Ordering code isplacement imension (mm - inches) Suction Pressure H E F H E F code H E F SAE FLANGE PORTS J518 (3000 PSI series) 2S 40 45-54 63-75 30.17 1.19 35.71 1.14 58.72 2.31 69.85 2.75 31.8 1.25 38.1 1.5 M10 x1.5 26.19 1.03 M12 x1.75 30.17 1.19 52.37 2.06 58.72 2.31 25.4 1 31.8 1.5 M10 x1.5 A C 58.72±0.1 2.31 ±0.004 G G 30.17 ` 1.19 ±0.15 Ø 31.8 1.22 +0.006 IA 1 1/4 1 SECTION G-G 18.71" 22.87" M10x1.5-6H n 4 fori 52.37±0.1 2.06 ±0.004 26.19 1.03 20+5 Nm 20+5 Nm F F Ø25.4 ±0.15 1 +0.006 IA SECTION F-F 18.71" 22.87" M10x1.5-6H n 4 fori 35.71 1.41 1 1/2 SECTION V-V 69.85±0.1 2.75 ±0.004 V V Ø38.1 1.50 IA 25+5 Nm 20.5.81" 24.5.96" M12 x1.75-6h n 4 fori Other ports 9 3.4 Single pump dimensions If the requested port type is not included in the previous versions, please indicate number 9 and specify the details in the request note 29/54

Pump with SAE- front cover A S3: 41.2 (1.62 ) S5: 46 (1.81 ) 13.5.53" 46.5 1.83" Ø14.3.56" IA 146 5.75" 103.6 4.08" Ø101.6 4" IA 158 6.22" 164.1 6.46" 0-0.05 24.6.97" S3: 13 teeth S5: 15 teeth 9.5.37" 135 5.31" Pump size A mm inch mm inch /40 132 5.20 87.8 3.46 /45 135 5.31 90.8 3.57 /54 140.8 5.54 96.6 3.80 /63 146.2 5.76 102 4.02 /75 153.8 6.06 109.6 4.31 Pump with SAE-C front cover A S4: 55.6 - (2.19") 16.5.65" 49.5 1.95" Ø17.5.69" IA 181 7.13" 103.6 4.08" Ø127 5" IA 158 6.22" 178.6 7.03" 0-0.05 24.6.97" S4: 14 teeth 12.7.5" 135 5.31" Pump size A mm inch mm inch /40 135 5.31 90.8 3.57 /45 138 5.43 93.8 3.69 /54 143.8 5.66 99.6 3.92 /63 149.2 5.87 105 4.13 /75 156.8 6.17 112.6 4.43 30/54

Pump with European body and front cover 22 80+20 Nm 14.5.57" 47 1.85" 32.5 1.28" 5.197" A Ø11.43" IA 124.2 4.89" 98 3.86" Ø 50.8 f8 2"IA -0.300-0.076 M14x1.5 24.6.97" 42 1.65" 154.6 6.09" 52.6 2.07" 17.5.69" Ø21.59.85" IA Taper 1:8 11.2.44" 18.71" Type A mm inch mm inch /40 - - - - /45 - - - - /54 144.2 5.68 100.1 3.94 /63 149.63 5.89 105.53 4.15 /75 157.23 6.19 113.13 4.45 31/54

4 Multiple gear pumps 4.1 Multiple gear pumps: + standard cast iron versions (SAE- and SAE-C versions only) Standard versions means separated inlet/outlet side ports, without shaft seal between pump stages 4.1.1 rive torque calculation example T max = T1 + T2 <see section 3.2> rive gear 1st pump 1st body edicated to tandem version T imax = 200 Nm rive gear 2nd pump 2nd body with back cover integrated p 1 V c1 T max = 1.59 η m1 + 1.59 p 2 V c2 η m2 Example: /75 + /54 Common suction versions available on request. Please contact our Sales epartment. p1= 200 bar p2= 100 bar M rive gear 1st pump rive gear 2nd pump 75 200 54 100 T max = 1.59 + 1.59 = 265 + 95.4 = 360.4 Nm 90 90 T max = 360.4 460 Nm (splined 15T) T 2 = 95.4 T imax 200 Nm 32/54

4.1.2 Tandem pumps dimensions M Z C E 158 6.22" 135 5.31" Pump size C E mm inch mm inch mm inch /63 55.5 2.19 67.5 2.66 44.2 1.74 /75 63.1 2.48 67.5 2.66 44.2 1.74 SAE- SAE-C Front cover dimensions mm inch mm inch Z 46.5 1.83 49.5 1.95 For other covers dimensions see 3.3.1 33/54

4.1.3 imensions example 271.4-10.69" 41.2-1.62" 9.5.37" 227.2-8.94" 177.1-6.97" 109.6-4..31" 146 5.75" Ø101.6 4" 24.6.97" 158 6.22" 103.6 4.08" 164.1 6.46" Example /75+/54 (SAE- front cover): 135 5.31" Total lenght: 271.4=(Z++C++E)=46.5+63.1+67.5+50.1+44.2 Port position: 227.2= (Z++C+) = 46.5+63.1+67.5+50.1 109.6= (Z+) 46.5+63.1 4.1.4 How to order tandem pumps + standard cast iron versions 1st PUMP 2nd PUMP 1st OY 2nd OY 1 2 3 3 4 5 6 7 8 7 8 A P 3 1 2 H P / 7 5-5 4 - S - S 3 8 2 S C - 2 S - 1 Function AP= single gear pump - unidirectional 6 Front cover type see section 3.4.1 2 Series 3 4 312HP isplacement 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation 7 8 Type of ports code see section 3.3.2 Inlet/outlet port size code combination see section 3.3.2 E S = left-hand rotation = Right-hand rotation 5 Shaft end code H F see section 3.2 9 HRE section : Version - Progressive number (omitted) Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 34/54

4.2 Multiple gear pumps: +AP212HP standard cast iron versions (Tandem pumps combination of group 3 with group 2 are possible for SAE-, SAE-C and European versions, too) Standard versions means separated inlet/outlet side ports, without shaft seal between pump stages 4.2.1 rive torque calculation example T max = T1 + T2 <see section 3.2> rive gear 1st pump 1st body T imax = 200 Nm rive gear 2nd pump 2nd body pump AP212HP (Cast Iron) p 1 V c1 T max = 1.59 η m1 + 1.59 p 2 V c2 η m2 Example: /45 + AP212HP/15 p1= 200 bar p2= 100 bar M rive gear 1st pump rive gear 2nd pump Further information regarding group 2 pumps: see dedicated AP212HP Cast Iron Gear Pumps catalogue 45 200 15 100 T max = 1.59 + 1.59 = 159 + 26.5 = 185.5 Nm 90 90 T max = 185.5 230 Nm (splined 13T) T 2 = 26.5 T imax 200 Nm 35/54

4.2.2 Tandem pumps dimensions M AP212HP Z F G 158 6.22" 135 5.31" Pump size SAE-, SAE-C Pump size European version mm inch mm inch mm inch mm inch /40 41.3 1.63 37.5 1.48 ------------------------- ----------- ----------- ----------- ----------- /45 44.3 1.74 37.5 1.48 ------------------------- ----------- ----------- ----------- ----------- /54 50.1 1.97 37.5 1.48 /54 50.1 1.97 37.5 1.48 /63 55.5 2.19 37.5 1.48 /63 55.5 2.19 37.5 1.48 /75 63.1 2.48 37.5 1.48 /75 63.1 2.48 37.5 1.48 SAE- SAE-C European Front cover dimensions mm inch mm inch mm inch Z 46.5 1.83 49.5 1.95 50 1.97 For other covers dimensions see 3.3.1 Pump size AP212HP F G mm inch mm inch AP212HP/15 38.3 1.51 48.3 1.90 AP212HP/19 41.3 1.63 51.3 2.01 AP212HP/22 43.55 1.71 55.55 2.11 AP212HP/26 46.55 1.83 56.55 2.23 AP212HP/29 48.55 1.91 58.55 2.31 AP212HP/33 51.55 2.03 61.55 2.42 36/54

4.2.3 imensions example 214.9-8.46" 166.6-6.56" 41.2-1.62" 9.5.37" 128.3-5.05" 90.8-3.57" 146 5.75" Ø101.6 4" 24.6.97" 158 6.22" 103.6 4.08" 164.1 6.46" Example /45+AP212HP/15 (SAE- front cover): 135 5.31" Total lenght: 214.9 =(Z+++F+G) = 46.5+44.3+37.5+38.3+48.3 Port position: 166.6 = (Z+++F) = 46.5+44.3+37.5+38.3 90.8 = (Z+) = 46.5+44.3 37/54

4.2.4 How to order tandem pumps +AP212HP standard cast iron versions 1st PUMP 2nd PUMP 1st OY 2nd OY 1 2 3 22 23 4 5 6 7 8 27 28 A P 3 1 2 H P / 4 5-2 1 2 H P / 1 5 - S - S 3 8 2 S - 2 N - 1 Function 6 Front cover type AP= single gear pump - unidirectional see section 3.4.1 2 Series 3 312HP isplacement 7 Type of ports code see section 3.3.2 4 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation 8 Inlet/outlet port size code combination see section 3.3.2 E S = left-hand rotation = Right-hand rotation 5 Shaft end code H F see section 3.2 9 HRE section : Version - Progressive number (omitted) AP212HP 22 Series 27 Type of ports code 212HP 212HP (Cast iron) see section 3.5 AP212HP Catalogue 23 isplacement 212HP 15= 15.1 cm 3 /rev 19= 19.2 cm 3 /rev 22= 22.2 cm 3 /rev 26= 26.2 cm 3 /rev 29= 28.9 cm 3 /rev 33= 33 cm 3 /rev 28 29 Inlet/outlet port size code combination see section 3.5 AP212HP Catalogue ody material + seal material code see section 3.5.1 AP212HP Catalogue 212HP d 24 Version Omitted if 12 teeth standard LN= 12 teeth Low Noise version 30 ack cover type / Valve setting value see section 3.6 AP212HP Catalogue Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 38/54

4.3 Multiple gear pumps: +AP212 cast iron + aluminium versions (Tandem pumps combination of group 3 with group 2 are possible for SAE-, SAE-C and European versions, too) Standard versions means separated inlet/outlet side ports, without shaft seal between pump stages 4.3.1 rive torque calculation example T max = T1 + T2 <see section 3.2> rive gear 1st pump 1st body T imax = 200 Nm rive gear 2nd pump 2nd body pump AP212 (aluminium) p 1 V c1 T max = 1.59 η m1 + 1.59 p 2 V c2 η m2 Example: /45 + AP212/15 p1= 200 bar p2= 100 bar M rive gear 1st pump rive gear 2nd pump Further information regarding group 2 pumps: see dedicated AP212 Gear Pumps catalogue 45 200 15 100 T max = 1.59 + 1.59 = 159 + 26.5 = 185.5 Nm 90 90 T max = 185.5 230 Nm (splined 13T) T 2 = 26.5 T imax 200 Nm 39/54

4.3.2 Tandem pumps dimensions M AP212HP Z F G 158 6.22" 135 5.31" Pump size Pump size SAE-, SAE-C mm inch mm inch European version mm inch mm inch /40 41.3 1.63 37.5 1.48 ------------------------- ----------- ----------- ----------- ----------- /45 44.3 1.74 37.5 1.48 ------------------------- ----------- ---------- ----------- ---------- /54 50.1 1.97 37.5 1.48 /54 50.1 1.97 37.5 1.48 /63 55.5 2.19 37.5 1.48 /63 55.5 2.19 37.5 1.48 /75 63.1 2.48 37.5 1.48 /75 63.1 2.48 37.5 1.48 SAE- SAE-C European Front cover dimensions mm inch mm inch mm inch Z 46.5 1.83 49.5 1.95 50 1.97 For other covers dimensions see 3.3.1 Pump size AP212 aluminium F G mm inch mm inch AP212/4.5 24.3 0.96 46.6 1.83 AP212/6.5 25.8 1.02 48.1 1.89 AP212/8.5 27.3 1.08 49.6 1.95 AP212/11 29.3 1.54 51.6 2.03 AP212/15 32.3 1.27 54.6 2.15 AP212/19 35.3 1.39 57.6 2.27 AP212/22 37.6 1.48 59.9 2.36 AP212/26 40.6 1.60 62.9 2.48 40/54

4.3.3 imensions example 215.2-8.47" 160.6-6.32" 128.3-5.05" 41.2-1.62" 90.8-3.57" 9.5.37" 146 5.75" Ø101.6 4" 24.6.97" 158-4.02" 103.6 4.08" 164.1 6.46" Example /45+AP212/15 SAE-: 135 5.31" Total lenght: 214.9 = (Z+++F+G) =46.5+44.3+37.5+32.3+54.6 Port position: 160.6 = (Z+++F)= 46.5+44.3+37.5+32.3 90.8= (Z+) = 46.5+44.3 41/54

4.3.4 How to order triple pumps +AP212 cast iron + aluminium versions 1st PUMP 2nd PUMP AP212 Aluminium 1st OY 2nd OY 1 2 3 22 23 4 5 6 7 8 27 28 A P 3 1 2 H P / 4 5-2 1 2 / 1 5 - S - S 3 8 2 S - 2 N 1 Function AP= single gear pump - unidirectional 6 Front cover type see section 3.4.1 2 Series 3 4 312HP isplacement 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation 7 8 Type of ports code see section 3.3.2 Inlet/outlet port size code combination see section 3.3.2 E S = left-hand rotation = Right-hand rotation 5 Shaft end code H F see section 3.2 9 HRE section : Version - Progressive number (omitted) AP212 22 Series 27 Type of ports code 212 212 (Aluminium) see section 3.5 AP212 Catalogue 23 isplacement 212 4.5= 4.4 cm 3 /rev 6.5= 6.4 cm 3 /rev 8.5= 8.4 cm 3 /rev 11= 11.1 cm 3 /rev 15= 15.1 cm 3 /rev 19= 19.2 cm 3 /rev 22= 22.2 cm 3 /rev 26= 26.2 cm 3 /rev 28 29 Inlet/outlet port size code combination see section 3.5 AP212 Catalogue ody material + seal material code see section 3.5.1 AP212 Catalogue 212 d 24 Version Omitted if 12 teeth standard LN= 12 teeth Low Noise version 30 ack cover type / Valve setting value see section 3.6 AP212 Catalogue Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 42/54

4.4 Multiple gear pumps: ++AP212HP cast iron versions (: SAE- and SAE-C versions only) Standard versions means separated inlet/outlet side ports, without shaft seal among pump stages 4.4.1 rive torque calculation example T max = T1 + T2 + T3 <see section 3.2> rive gear 1st pump 1st body T imax = 200 Nm rive gear 2nd pump 2nd body T imax = 200 Nm rive gear 3rd pump 3rd body pump AP212HP (cast iron) p 1 V c1 p 2 V c2 T max = 1.59 + 1.59 + 1.59 η m1 η m2 p3 V c3 η m3 Example: /75 + /54 + AP212HP/15 p1= 210 bar p2= 150 bar p3= 120 bar Further information regarding group 2 pumps: see dedicated AP212HP Cast Iron Gear Pumps catalogue M rive gear 1st pump Intermediate drive gears T max = 1.59 75 210 + 1.59 54 150 + 1.59 15 120 = 278.25 + 143.1+ 31.8= 453.15 Nm 90 90 90 T max = 453.15 950 Nm (splined 14T) T 2 = 174.9 T imax 200 Nm T 3 = 31.8 T imax 200 Nm Common suction versions available on request. Please contact our Sales epartment. 43/54

4.4.2 Triple/multiple pumps dimensions M AP212HP Z C F G 158 6.22" 135 5.31" Pump size C mm inch mm inch mm inch /40 41.3 1.63 - - 37.5 1.48 /45 44.3 1.74 - - 37.5 1.48 /54 50.1 1.97 - - 37.5 1.48 /63 55.5 2.19 67.5 2.66 37.5 1.48 /75 63.1 2.48 67.5 2.66 37.5 1.48 SAE- SAE-C Front cover dimensions mm inch mm inch Z 46.5 1.83 49.5 1.95 For other covers dimensions see 3.3.1 Pump size AP212HP F G mm inch mm inch AP212HP/15 38.3 1.51 48.3 1.90 AP212HP/19 41.3 1.63 51.3 2.01 AP212HP/22 43.55 1.71 55.55 2.11 AP212HP/26 46.55 1.83 56.55 2.23 AP212HP/29 48.55 1.91 58.55 2.31 AP212HP/33 51.55 2.03 61.55 2.42 44/54

4.4.3 imensions example 354.3-13.96" 306-12.05" 230.2-9.06" 180.1-7.09" 55.6-2.19" 112.6-4.33" 12.7 0.5" 181 7.13" Ø127-5" IA 24.6.97" 158 4.02" Ø17.5.69" 103.6 4.08" Example /75+/54+AP212HP/15 SAE-C: 135 5.31" Total lenght: 354.3 = (Z++C+++F+G) =49.5+63.1+67.5+50.1+37.5+38.3+48.3 Port position: 306 = (Z++C+++F)= 49.5+63.1+67.5+50.1+37.5+38.3 230.2 = (Z++C+) = 49.5+63.1+67.5+50.1 112.6= (Z+) 49.5+63.1 45/54

4.4.4 How to order triple pumps ++AP212HP cast iron versions 1st PUMP 2nd PUMP 3rd PUMP AP212 Aluminium 1st OY 2nd OY 3rd OY 1 2 3 3 22 23 4 5 6 7 8 7 8 27 28 A P 3 1 2 H P / 7 5-5 4-2 1 2 / 1 5 - S - S 4 8 C 2 S C - 2 S - 2 N 1 Function 6 Front cover type AP= single gear pump - unidirectional see section 3.4.1 2 Series 3 4 312HP isplacement 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation 7 8 Type of ports code see section 3.3.2 Inlet/outlet port size code combination see section 3.3.2 E S = left-hand rotation = Right-hand rotation 5 Shaft end code H F see section 3.2 9 HRE section : Version - Progressive number (omitted) AP212HP 22 Series 27 Type of ports code 212HP 212HP (Cast iron) see section 3.5 AP212HP Catalogue 23 isplacement 212HP 15= 15.1 cm 3 /rev 19= 19.2 cm 3 /rev 22= 22.2 cm 3 /rev 26= 26.2 cm 3 /rev 29= 28.9 cm 3 /rev 33= 33 cm 3 /rev 28 29 Inlet/outlet port size code combination see section 3.5 AP212HP Catalogue ody material + seal material code see section 3.5.1 AP212HP Catalogue 212HP d 24 Version Omitted if 12 teeth standard LN= 12 teeth Low Noise version 30 ack cover type / Valve setting value see section 3.6 AP212HP Catalogue Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 46/54

4.5 Multiple gear pumps: ++AP212 cast iron + aluminium versions (: SAE- and SAE-C versions only) Standard versions means separated inlet/outlet side ports, without shaft seal among pump stages 4.5.1 rive torque calculation example T max = T1 + T2 + T3 <see section 3.2> rive gear 1st pump 1st body T imax = 200 Nm rive gear 2nd pump 2nd body T imax = 200 Nm rive gear 3rd pump 3rd body pump AP212 (aluminium) p 1 V c1 p 2 V c2 T max = 1.59 + 1.59 + 1.59 η m1 η m2 p3 V c3 η m3 Example: /75 + /54 + AP212/15 p1= 210 bar p2= 150 bar p3= 120 bar Further information regarding group 2 pumps: see dedicated AP212 Gear Pumps catalogue M rive gear 1st pump Intermediate drive gears T max = 1.59 75 210 + 1.59 54 150 + 1.59 15 120 = 278.25 + 143.1+ 31.8= 453.15 Nm 90 90 90 T max = 444.15 950 Nm (splined 14T) T 2 = 174.9 T imax 200 Nm T 3 = 31.8 T imax 200 Nm Common suction versions available on request. Please contact our Sales epartment. 47/54

4.5.2 Triple/multiple pumps dimensions M AP212 Z C F G 158 6.22" 135 5.31" Pump size C mm inch mm inch mm inch /40 41.3 1.63 - - 37.5 1.48 /45 44.3 1.74 - - 37.5 1.48 /54 50.1 1.97 - - 37.5 1.48 /63 55.5 2.19 67.5 2.66 37.5 1.48 /75 63.1 2.48 67.5 2.66 37.5 1.48 SAE- SAE-C Front cover dimensions mm inch mm inch Z 46.5 1.83 49.5 1.95 For other covers dimensions see 3.3.1 Pump size AP212 aluminium F G mm inch mm inch AP212/4.5 24.3 0.96 46.6 1.83 AP212/6.5 25.8 1.02 48.1 1.89 AP212/8.5 27.3 1.08 49.6 1.95 AP212/11 29.3 1.54 51.6 2.03 AP212/15 32.3 1.27 54.6 2.15 AP212/19 35.3 1.39 57.6 2.27 AP212/22 37.6 1.48 59.9 2.36 AP212/26 40.6 1.60 62.9 2.48 48/54

4.5.3 imensions example 354.6-13.96" 300-11.81" 230.2-9.06" 180.1-7.09" 55.6-2.19" 112.6-4.33" 12.7-0.5" 181 7.13" Ø127-5" IA 24.6.97" 158 6.22" Ø17.5.69" 103.6 4.08" Example /75+/54+AP212/15 SAE-C: 135 5.31" Total lenght: 354.6 = (Z++C+++F+G) =49.5+63.1+67.5+50.1+37.5+32.3+54.6 Port position: 300 = (Z++C+++F)= 49.5+63.1+67.5+50.1+37.5+32.3 230.2 = (Z++C+) = 49.5+63.1+67.5+50.1 112.6= (Z+) 49.5+63.1 49/54

4.5.4 How to order triple pumps ++AP212 cast iron + aluminium versions 1st PUMP 2nd PUMP 3rd PUMP AP212 Aluminium 1st OY 2nd OY 3rd OY 1 2 3 3 22 23 4 5 6 7 8 7 8 27 28 A P 3 1 2 H P / 7 5-5 4-2 1 2 / 1 5 - S - S 4 8 C 2 S C - 2 S - 2 N 1 Function 6 Front cover type AP= single gear pump - unidirectional see section 3.4.1 2 Series 3 4 312HP isplacement 40= 40.2 cm 3 /rev 45= 45 cm 3 /rev 54= 54.4 cm 3 /rev 63= 63.1 cm 3 /rev 75= 75.3 cm 3 /rev Rotation 7 8 Type of ports code see section 3.3.2 Inlet/outlet port size code combination see section 3.3.2 E S = left-hand rotation = Right-hand rotation 5 Shaft end code H F see section 3.2 9 HRE section : Version - Progressive number (omitted) AP212 22 Series 27 Type of ports code 212 212 (Aluminium) see section 3.5 AP212 Catalogue 23 isplacement 212 4.5= 4.4 cm 3 /rev 6.5= 6.4 cm 3 /rev 8.5= 8.4 cm 3 /rev 11= 11.1 cm 3 /rev 15= 15.1 cm 3 /rev 19= 19.2 cm 3 /rev 22= 22.2 cm 3 /rev 26= 26.2 cm 3 /rev 28 29 Inlet/outlet port size code combination see section 3.5 AP212 Catalogue ody material + seal material code see section 3.5.1 AP212 Catalogue 212 d 24 Version Omitted if 12 teeth standard LN= 12 teeth Low Noise version 30 ack cover type / Valve setting value see section 3.6 AP212 Catalogue Unpainted pumps are ucher Hydraulics standard; should a painted component be required, this feature must be specified in its purchase order. 50/54

5 Product identification plate 2 1 : Rotation (= Clockwise rotation - S= Counterclockwise rotation) 1 S 7A/**** 2001073863011 /45 S382S 3 4 5 2 : Manufacturing year and month 3 : Progressive identification no. (optional) 4 : ucher Hydraulics S.p.A. product code 5 : escription MAE IN ITALY Manufacturing month Manufacturing year 2017 2018 2019 2020 2021 January 7A 8M 9M 0M 1M February 7 8N 9N 0N 1N March 7C 8P 9P 0P 1P April 7 8Q 9Q 0Q 1Q May 7E 8R 9R 0R 1R June 7F 8S 9S 0S 1S July 7G 8T 9T 0T 1T August 7H 8U 9U 0U 1U September 7I 8V 9V 0V 1V October 7J 8Z 9Z 0Z 1Z November 7K 8X 9X 0X 1X ecember 7L 8Y 9Y 0Y 1Y 51/54

6 Application form ate: Contact: Customer: Location: Overall quantity per year: Minimum batch size: elivery time requested: Feasibility: Prototypes: Series: Target price: Type of application: Rotation S External gear pump general data R Speed range isplacement: Single pump (cm 3 /rev) ouble pump (cm 3 /rev) 1st 2nd Continuous work pressure (bar) Peak work pressure (bar) 1st 1st 2nd 2nd 3rd 3rd Multiple pump (cm 3 /rev) 1st 2nd 3rd Oil type rive shaft Oil temperature ( C) min max Port type Oil viscosity (cst) min max Front cover type Suction line pressure earing support Voltage Front cover material rain case pressure Intermediate cover (with or without shaft seal) with without Radial load (N) ack cover type/circuit Axial load (N) ack cover material aluminium cast iron Working hours per year Valves Cycles per year Additional notes: 52/54

53/54

info.it@bucherhydraulics.com www.bucherhydraulics.com 2017 by ucher Hydraulics S.p.A, I-42124 Reggio Emilia All rights reserved. ata is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. ecause the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 410.110.000 54/54