STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Similar documents
STC 2P025 Series Solenoid Valve

STC 2E Series High Pressure Solenoid Valves Two-Way, Pilot Piston, Normally Closed

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2W Series Solenoid Valves

STC 2L Series Solenoid Valves

3V SERIES SOLENOID VALVE

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

4V130P-430P SERIES AIR PILOT VALVE

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

2V1-3V1 SERIES SOLENOID VALVE

STC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM

STC KS/KD Air Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2W160 Series Solenoid Valves

KS/KD Air Actuated Ball Valves

AIR & ELECTRIC ACTUATED VALVES

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

OWNERS MANUAL JANUARY 2007 ISO

DAP-625S and DAP-875S

PIVOT BUSHING KIT GM F-BODY

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

GWC Valve International

HR-20P Pneumatically Controlled Pressure Regulator

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Easytork Solenoid Valve IOM

FAN POWERED HEPA FILTER UNIT

Installation Instructions

ADI-125/750 ADI-125/1500 ADI-125/2500

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Terms and Conditions

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

10 Year Limited Warranty

SERIES 7400 THREE PIECE BALL VALVES

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

37SCENE 46SCENE 79SCENE

2015 & 2018 Fender Brace Installation Instructions

WEB CONTROL PRODUCTS

22421 SPORT SWAY BAR SET TOYOTA COROLLA

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Straight-Bore Clutch LSCC-32, 44, 54

BMRX Series ROTARY LEVEL CONTROL

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

MIL-24/2600Q MIL-24/3200DQ

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

2282R GM A Body Extreme Rear Sway Bar

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

INSTALLATION INSTRUCTIONS

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SERIES 2200 Replaceable Seat Butterfly Valves

Sport Sway Bar Kit UP SCION xb

1401 / 1402 / 1403 ADJUSTABLE TRAILING ARM MOUNT BRACES INSTALLATION OF HOTCHKIS PERFORMANCE ADJUSTABLE TRAILING ARM MOUNT BRACES

SERIES 2100 Resilient Seated Butterfly Valves

SPC-PANEL Simplex, Single Phase Pump Control Panel

COMPRESSED AIR LOADER MODEL: AL-1

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

Camaro / Firebird. Please read the following key points before installing this kit.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

BD SUPER B SPECIAL Dodge 5.9L Cummins 24v ISB

FCB-450, LCB-600, MCB-800

Power. On Your Terms.

Please read the following key points before installing this kit.

OWNERS MANUAL JANUARY 2007 ISO

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

DC to AC Power Inverters

Installation / Operation Instructions Sunnex ORION Series Exam Lights

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS

Model C230 Pump Controller

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

ActuLink ABS Module - ABS-MOD-400

END USER TERMS OF USE

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830

II DISTRIBUTION & SUBSTATION TYPE C

Sport Sway Bar Kit Chevy Camaro

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

P/N# Performance Lowering Springs Installation Instructions

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

EZR7 Universal 7-Pin Heavy Duty Plug Installation Instructions and Product Warranty Professional Installation Required

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

SUNTURA SOLAR TRACKER

Scale Feeder Manifold Water Filtration System Instruction Manual

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Series 2100 Operating Instructions

Rear Leaf Spring Kit 24366, Chrysler B-body, Chrysler E-Body

Pump Installation and Service Manual HRS Hydromatic Retractable System

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

INSTALLATION OF HOTCHKIS FRONT STABILIZER BAR

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

1 2-Inch Station Outlet Valves

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Rig Master Power by Mobile Thermo Systems Inc.

HSIV PLOW OPERATOR S MANUAL

DC to AC Power Inverters

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

Transcription:

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8 2P050-3/8F Valve Type 2 Way, Normally Closed (NC) Action Direct Acting Solenoid Valve Orifice 5.0 MM Operating Pressure Vacuum to 50 PSI Operating Temperature 32 to 122 F (0 to 50 C) Port Size (Tube OD) 1/4 NPT 3/8 NPT 3/8 Push-In Fitting Wetted Surfaces (NSF Compliant) Coil Duty Voltage Voltage Tolerance Coil Power Electrical Connections Installation Service Valve Body: Delrin Plastic, Can be Customized to any Plastic Seals: NBR (Buna N), Silicone, Viton Double Seals (Fitting Connection Only) Armature Assembly: Stainless Steel H Class, IP65, 100% ED Continuous Duty Options: 12, 24 VDC; 24,110/120, 220/240 VAC (50/60Hz) ±10% of Specified voltage 20 W DIN 43650A, Option: Molded Cable, ATEX Explosion Proof No Orientation Requirement (Optimum Position: Flow Horizontal & Solenoid Vertical) Potable Water, Air, Liquid 1

2P050 Series Solenoid Valve Components Nut (Plated Steel) Gasket Washer (Plated Steel) Screw (M3-30) O-Ring (Silicone) Encapsulated Solenoid Coil DIN Housing & Terminal Block (IP65) O-Ring (Silicone) Strain Relief Connector Armature Tube Assembly (Stainless Steel) Spring (Stainless Steel) NOTE: Model shown with Push-In Fitting Connection option. Threaded Connection and Tube Connection options share components other than valve body. Plunger (Stainless Steel) O-Ring (Silicone) Plunger Seal (NBR) Valve Body (Delrin) Release Button Each Side (Delrin) [Fitting Connection Only] Double O-Rings Each Side (Viton/FKM) [Fitting Connection Only] 2

Material Test Reports This document certifies that STC products have been subjected to quality assurance procedures and meet the material and performance specifications published by Sizto Tech Corporation (STC). The products have been manufactured, processed, inspected, and tested according to STC internal requirements and ISO 9001 standards. ISO 9001:2015 Certificate Number: QNB17180318 Date of Issue: 10, March, 2018 Valid Until: 28, February, 2021 Individual materials and components used in this product have been tested and conform to applicable published standards according to chart below. Please be advised that STC does not conduct its own material analysis of all raw materials, rather, STC relies on the statements of its material suppliers & reserves the rights to independently test raw materials if necessary. Material Test Reports may be available for specific products upon request. Material Use Location Material Standard 316 Stainless Steel Metal Fittings, Valves, Air Cylinders ASTM A240/A2666 304 Stainless Steel Valves, Air Cylinders ASTM A240/A666 CF8M Stainless Steel Valves ASTM A351/A743 Brass Valves ASTM B36/B62 Nickel-Plated Brass Composite Fittings ASTM B456/B927 Acetal Homopolymer (Delrin) Valves ASTM D4181/D6778 14 Acetal Copolymer (POM) Composite Fittings ASTM D4181/D6778 14 FKM (Viton) Seals ASTM D1418 PTFE (Teflon) Valves, Seals ASTM D3294 15 NBR (Buna N) Seals ASTM D1387 06 EPDM Seals ASTM D3568 03 Polybutylene Terephthalate (PBT) Composite Fittings ASTM D4000 3

To Connect the Valve Inlet & Outlet: Connect the inlet & outlet to the valve ports according to the flow direction arrow marked on the valve To Install the Coil: Put the coils on to the armature tube of the valve. Place the lock washer & nut on to the armature tube. Hand tighten the nut, then use a wrench to tighten the nut another quarter-turn. Do not over-tighten the nut, as it may cause the armature tube to fail prematurely. To Connect a DIN Coil: Installation & Operation 1. Remove the Philips-head screw from the plastic DIN housing & unplug it from the DIN coil 2. From the screw opening, push the terminal block out from the plastic DIN housing. 3. Note the 1, 2, and ground symbols on the underside of the DIN enclosure. 4. For DC DIN Coils, connect 1 to your Positive Lead & 2 to your Negative lead. 5. For AC DIN Coils, connect 1 to your HOT lead, 2 to your Neutral lead, & to your ground if required. Do not energize the coil without installing it onto the valve or connect the coil to a different voltage than specified. This will burn the coil and could create fire hazards. Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil body. The coil temperature may rise significantly if energized for extended periods this is normal. Although the coil is made of flame-retardant material, misuse of the coil could create fire hazards & generate smoke and/or a burning odor. If these conditions are encountered, the coil temperature has risen above safe levels and the power should be disconnected immediately. Operation: This valve is a two-way, normally closed, direct-acting valve & does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the plunger rests on the main orifice & is held in place by the plunger spring force, sealing the valve. When the coil is energized (right diagram), the solenoid lifts the plunger & allows the working medium to flow through the orifice. The working medium & flow direction are indicated in purple in the diagrams. De-Energized (Closed) Energized (Open) Flow Direction 4

2P050 Series Dimensions Push-In Fitting Connection 5

2P050 Series Dimensions Threaded Connection 1/4 NPT 6

2P050 Series Dimensions Threaded Connection 3/8 NPT 7

2-Way Direct Acting Valves Maintenance & Troubleshooting Guide Warning: DO NOT over tighten the nut holding the coil to the armature tube. Over tightening may result in damage to the welded joint. Attaching a Coil to a Valve: After wiring the coil, fit the coil assembly over the armature tube. Ensure that the threads of the tube are accessible. Fit the spring or lock washer over the assembly. For spring washers, the concave side should be oriented toward the coil. Tighten the nut over the washer by hand. For standard washers, tighten the nut an additional ¼ turn with a wrench if necessary. For spring washers, continue to tighten the nut until the spring washer is almost completely compressed. Installation Procedure: Connect the default outlet to the outlet port indicated by an arrow or the number 1 on the valve body. Connect the default inlet to the pressure port indicated by the tail of the arrow or a P on the valve body. The arrow marked on the valve body indicates the direction of flow. Notes: After an extended period of operation, the solenoid coil may burn out. This commonly occurs when input voltages are higher than the coil s specifications. If the valve does not make a clicking sound when energized/de-energized, the coil likely needs to be replaced. If you are using the valve at a low temperature, it may exhibit a small leak when first activated. To fix this, cycle the valve at the highest available operating pressure until there is no longer a leak. This process will create a proper mating surface between the seal and the orifice. Maintenance Procedure: 1. Turn off the power supply to the valve & ensure it is safely locked-out. 2. Remove any coils attached to the valve. 3. Unscrew the holding plate (if applicable) and the armature tube assembly and remove it from the valve body. The plunger & spring are not fastened to the tube and will fall out. 4. Check for any debris that may have collected on the plunger & the hole in the center of the valve. Clean any dirty surfaces or debris with clean water. 5. Place the spring back in the plunger & insert the plunger back into the armature tube. 6. Screw the armature tube & holding plate back into the valve. 8

To Connect a DIN Coil: Electrical Connections Remove the Philips screw from the plastic housing & unplug from the DIN coil. Use the removed screw to push the terminal block out of the plastic DIN housing. Note the 1, 2, and ground symbols. For DC DIN Coils, connect 1 to your positive lead & 2 to your negative lead. For AC DIN Coils, connect 1 to your HOT lead, 2 to your NEUTRAL lead, and to your ground lead, if required. To Connect a Grommet Coil: For DC Coils, connect the red wire to your positive lead & the black wire to your negative lead. For AC Coils, connect the black wire to your HOT lead & the white wire to your NEUTRAL lead. For Coils provided with Molded Cables, the color of the wire indicates the type of lead: GREEN = Ground Wire BLUE = Positive or HOT Wire BROWN = Negative or Neutral Wire DIN Coil Encapsulated Coil Terminal Block DIN Housing Grommet Coil Lead Wires 9

Terms & Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing & signed by STC. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipments must be reported within 15 days. CANCELLATION POLICY: Blanket orders can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is canceled within 90 days of scheduled ship date, and a 20% charge if canceled within 60 days. Regular orders for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers, or request an STC Credit Application. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. OBLIGATIONS You warrant, represent and agree: (1) to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with law or these terms and conditions, or from use of the product. SAFETY WARNING: Improper Selection or Failure to follow Usage Instructions of the products described on the Sizto Tech Corporation (STC) Internet Site and its related publications can cause Death, Personal Injury, and Property Damage. All system set-ups require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience. IMPORTANT NOTICE: All prices are subject to change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation to incorporate new factors in equipment previously sold. Information contained herein may be changed without prior notification. Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 94043 USA Tel: 650-856-8833 Fax: 650-856-8811 Email: Sales@StcValve.com www.stcvalve.com www.stcvalve.com 10