Eliwell Device Manager - Parameters Table [EL61.00.DAX] Author: m.deantoni Machine: GIND Date: 28/04/ :31. Model: ST54X.

Similar documents
<IMG INFO> 425,15 349, ,85 14,15-1. Energy SB-SD-SCW600 Compact controller with Hot Water management for domestic heat pumps

STRA-24 for chilled beams

MATRIX LLC LEVEL CONTROL PANEL

ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

Modbus Integration Integration for Modbus Functionality for VT8600 Series

ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Combined Ventilation Controller RVWS-T-113HA

VENCO. Instruktions MANUAL. typ: pco LAN PERFORMO SWN. TPi Klimatimport AB Tel: Fax:

HWT 1402/9603. free cooling

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Power Flame Incorporated

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Commissioning manual. - Simplified VAV solution with full potential... Rev. Pascal-Comm RM-ver / RC-ver 1.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Touch Screen User Interface Operation Manuals For Crust Freezer Version 2.1 P27600 Dated December 2010

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

technical catalogue tetris KW Chiller and heat pumps air/water

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

RC-DO. Room controllers with display and manual forced ventilation function

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Remote Temperature Controllers. Quick Selection Guide

DTR CG OPTIMA ver.3.0 ( )

Installation Instructions

Control Panel. Operation and Service Manual

Installation Manual. ACL3200 Flare Stack / Incinerator Ignition Systems

Ventilation in balance

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

DDEC VI APPLICATION AND INSTALLATION. Parameter Group. Diagnostic Name. Min Max Default Access Range

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Refrigerators (Combis)

Vission 20/20 micro-controller. Operation and service manual

APM. ! Display range: -9999~9999; decimal point selectable! 2 Alarms output or 2 Digital input / 2 Pulses output for forward KWH & reverse KWH

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Installation and operating instruction. Combustion manager W-FM 100 und W-FM /

MIZCON Plus Cooling Tower Controller Model R7010W

Appendix A: Inputs, Outputs, and Parameters

Quick Start Guide of CV50- ControlVIT Series

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

VTZ variable speed Reciprocating compressors

YOSHI AWS D3 YoshiAirWaterSystem

SPEEDRIVE INSTRUCTIONS MANUAL

Micro Controller based Motor Protection Relay & Motor Management System

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Service Manual Preliminary Version. MCQUAY MicroTech II Control plan+driver. for Modular Chillers

Example application for an supply air control with recirculated air addition. HVAC Application Note 3

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

KE2 Temp + Defrost (pn 20611) Installation Manual

AT30 SERIES BATTERY CHARGER

Step And Rack Controllers

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

WQL/WQH/WQRC 524 to 1204

RKE RKE FO RKE BF RHR SRS Series

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Temperature Controller OVATION 214 User's Guide

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C)

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

Superheat controller EKC 315A

Option M4 Engine control and protection Functional description Modes and sequences General product information PID controller Additional functions

Technical Specificaions. kwh Energy Meter

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2

Operation Manual. Temperature Controller ST49. Revision 1.1, dated on

Wiring Diagrams DIAGRAM INDEX

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

AIR VOLUME TRANSMITTER / CONTROLLER IML

Chiller unit SLS-SLH

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

EASY TO RUN. Road Mode Operation. Standby Mode Operation. Temperature Set-point. Defrost. Alarm display. Malfunction codes table. Unit Data.

Phone: Fax: Web:

Superstatic 440. Static Heat- and Cooling Meter. Application

One step forward. Multi-pump and Multi-function control panel

Our complete line of refrigeration systems and performance options. Truck/Trailer/rail Product guide

Thermal Solutions Communications Gateway Instruction Manual Part Number Revised: April 13, 2015 Contents

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Temperature Controller TC5-2V8SA USER'S MANUAL. M rev. 03 K rev. 00

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

GS2 Series - Introduction

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Electro Controls. Temperature Controllers WattsIndustries.co.uk

ROGERS MACHINERY COMPANY, INC

YORK Modbus Solution to the YK Chiller with Variable Speed Drive

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

Transcription:

Group Name: CF. 1 CF00 - Type of analogue input AI1 num 0 2 0 2 2 CF01 - Type of analogue input AI2 num 0 2 0 2 3 CF02 - Type of analogue input AI3 num 0 6 0 5 4 CF03 - Type of analogue input AI4 num 0 6 0 0 9 CF04 - Last value analogue input AI3 scale C/Bar -4,6 [10] 99,9 50 51,6 10 CF05 - First value analogue input AI3 scale C/Bar -50 51,6 [9] 0-4,6 11 CF06 - Last value analogue input AI4 scale C/Bar 0 [12] 99,9 50 50 12 CF07 - First value analogue input AI4 scale C/Bar -50 50 [11] 0 0 13 CF08 - Analogue input AI1 differential C -12 12 0 0 14 CF09 - Analogue input AI2 differential C -12 12 0 0 15 CF10 - Analogue input AI3 differential C/Bar -12 12 0 0 16 CF11 - Analogue input AI4 differential C/Bar -12 12 0 0 17 CF12 - Analogue input AI1 configuration num 0 6 0 1 18 CF13 - Analogue input AI2 configuration num 0 6 0 2 19 CF14 - Analogue input AI3 configuration num 0 11 0 10 20 CF15 - Analogue input AI4 configuration num 0 11 0 0 21 CF16 - Digital input DI1 configuration num -32 32 0-1 22 CF17 - Digital input DI2 configuration num -32 32 0-2 23 CF18 - Digital input DI3 configuration num -32 32 0 0 24 CF19 - Digital input DI4 configuration num -32 32 0-5 25 CF20 - Digital input DI5 configuration num -32 32 0-27 28 CF23 - Analogue input AI1 configuration when configur... num -32 32 0 0 29 CF24 - Analogue input AI2 configuration when configur... num -32 32 0 0 30 CF25 - Analogue input AI3 configuration when configur... num -32 32 0 0 31 CF26 - Analogue input AI4 configuration when configur... num -32 32 0 0 32 CF27 - Type of analogue output AO3 num 0 2 0 0 35 CF30 - Analogue output AO3 configuration num -13 16 0 0 38 CF33 - Enable analogue output TC1 num 0 1 1 1 39 CF34 - Enable analogue output AO1 num 0 1 0 0 40 CF35 - Enable analogue output AO2 num 0 1 0 0 41 CF36 - Analogue output TC1 phase displacement num 0 90 27 20 42 CF37 - Analogue output AO1 phase displacement num 0 90 27 10 43 CF38 - Analogue output AO2 phase displacement num 0 90 27 10 44 CF39 - Analogue output TC1 pulse time num 5 40 10 20 45 CF40 - Analogue output AO1 pulse time num 5 40 10 10 46 CF41 - Analogue output AO2 pulse time num 5 40 10 10 47 CF42 - Analogue output TC1 configuration num -13 16 14 14 48 CF43 - Analogue output AO1 configuration num -13 16 0 0 49 CF44 - Analogue output AO2 configuration num -13 16 0 0 50 CF45 - Digital output DO1 configuration num -13 13 1 1 51 CF46 - Digital output DO2 configuration num -13 13 3 3 52 CF47 - Digital output DO3 configuration num -13 13 5 0 53 CF48 - Digital output DO4 configuration num -13 13 7 13 54 CF49 - Digital output DO5 configuration num -13 13 2 0 56 CF51 - Digital output AO1 configuration num -13 13 6 0 57 CF52 - Digital output AO2 configuration num -13 13 0 0 59 CF54 - Select COM1 protocol num 0 1 1 1 Page 1/8

60 CF55 - Eliwell protocol controller address num 0 14 0 0 61 CF56 - Eliwell protocol controller family num 0 14 0 0 68 CF63 - Modbus protocol controller address num 1 255 1 1 69 CF64 - Modbus baud rate protocol num 0 7 3 3 70 CF65 - Modbus parity protocol num 1 3 1 1 71 CF66 - Customer code 1 num 0 255 0 0 72 CF67 - Customer code 2 num 0 255 0 0 73 REL - Televis KeyType num 0 255 5 5 79 CF72 - RTC present num 0 1 1 0 80 CF73 - Analogue input 5 present num 0 2 0 0 83 CF76 - Analogue input AI5 differential C/Bar -12 12 0 0 84 CF77 - Analogue input AI5 configuration num 0 6 0 0 Group Name: Ui. 86 Ui00 - LED1 configuration num 0 13 1 1 87 Ui01 - LED2 configuration num 0 13 2 2 88 Ui02 - LED3 configuration num 0 13 7 0 89 Ui03 - LED4 configuration num 0 13 8 8 90 Ui04 - LED5 configuration num 0 13 6 6 91 Ui05 - LED6 configuration num 0 13 11 11 92 Ui06 - LED7 configuration num 0 13 3 3 93 Ui07 - Standby LED configuration num 0 1 1 1 95 Ui09 - Fundamental state display selection num 0 7 0 0 96 Ui10 - Enable defrost/sanitary water function from key num 0 1 1 1 97 Ui11 - Enable MODE function from key num 0 1 1 1 98 Ui12 - Enable DISP function from key num 0 1 1 0 99 Ui13 - Enable STAND BY function from key num 0 1 1 0 100 Ui14 - Enable SET function from key num 0 1 1 1 103 Ui17 - Installation engineer password num 0 255 1 13 104 Ui18 - Manufacturer password num 0 255 2 15 Group Name: tr. 132 tr00 - Temperature control type num 0 2 0 0 133 tr01 - Enable heating pump num 0 1 1 0 134 tr02 - Select temperature control probe in Cool num 0 5 0 0 135 tr03 - Select temperature control probe in Heat num 0 5 1 0 136 tr04 - Temperature control setpoint in Cool C/Bar 8 [138] 30 [139] 12 12 137 tr05 - Temperature control setpoint in Heat C/Bar 8 [140] 42 [141] 40 42 138 tr06 - Minimum temperature control setpoint in Cool C/Bar -50 30 [139] 11 8 139 tr07 - Maximum temperature control setpoint in Cool C/Bar 8 [138] 99,9 20 30 140 tr08 - Minimum temperature control setpoint in Heat C/Bar -50 42 [141] 30 8 141 tr09 - Maximum temperature control setpoint in Heat C/Bar 8 [140] 99,9 45 42 142 tr10 - Temperature control hysteresis in Cool C/Bar 0 25,5 3 2 143 tr11 - Temperature control hysteresis in Heat C/Bar 0 25,5 3 2 144 tr12 - Insert steps/compressors differential in Cool C/Bar 0 25,5 3 2 145 tr13 - Insert steps/compressors differential in Heat C/Bar 0 25,5 3 2 146 tr14 - Select probes for temperature control differen... num 0 3 0 0 147 tr15 - Select probes for temperature control differen... num 0 3 0 0 148 tr16 - Enable stop heat pump function num 0 1 0 0 149 tr17 - Stop heat pump function setpoint C -50 99,9 10 10 Page 2/8

150 tr18 - Stop heat pump hysteresis C 0 25,5 2 2 151 tr19 - Setpoint differential in Cool from Economy input C/Bar -25,5 25,5 5 5 152 tr20 - Setpoint differential in Heat from Economy Input C/Bar -25,5 25,5 5 5 Group Name: St. 153 St00 - Select operating mode num 0 2 2 0 154 St01 - Enable change mode from analogue input num 0 1 0 0 155 St02 - Select probe to change automatic mode num 0 2 0 1 156 St03 - Differential for change automatic mode in Heat C -25,5 25,5-10 -10 157 St04 - Differential for change automatic mode in Cool C -25,5 25,5 10 10 Group Name: CP. 158 CP00 - Type of compressor num 0 1 0 0 159 CP01 - Number of compressors per circuit num 1 2 2 1 160 CP02 - Select compressor on sequence num 0 6 0 1 161 CP03 - Minimum off/on for same compressor sec*10 0 255 18 18 162 CP04 - Minimum on/on time for same compressor sec*10 0 255 30 30 163 CP05 - Minimum on/on time for different compressors sec 0 255 10 10 164 CP06 - Minimum off/off time for different compressors sec 0 255 10 10 165 CP07 - Minimum compressor on time sec*10 0 255 2 2 166 CP08 - Minimum compressor on time per splitting incre... sec 0 255 10 10 167 CP09 - Minimum compressor on time per splitting decrease sec 0 255 5 5 168 CP10 - Compressor operating time for each on sequence sec*10 0 255 18 18 Group Name: Pi. 169 Pi00 - Enable primary circuit water pump num 0 1 1 1 170 Pi01 - Select primary circuit water pump function num 0 3 1 0 171 Pi02 - Delay primary circuit water pump on - compress... sec 0 255 60 20 172 Pi03 - Delay compressor off - primary circuit water p... sec 0 255 60 120 173 Pi04 - Minimum primary circuit water pump speed in Cool % 0 100 30 30 174 Pi05 - Maximum primary circuit water pump speed in Cool % 0 100 100 100 175 Pi06 - Minimum primary circuit water pump setpoint sp... C -50 99,9 20 20 176 Pi07 - Proportional band primary circuit water pump i... C -25,5 25,5 8 8 177 Pi08 - Fan speed setpoint for primary circuit water p... % 0 100 80 80 178 Pi09 - Surge current time primary circuit water pump... sec 0 255 2 2 179 Pi10 - Minimum primary circuit water pump speed in Heat % 0 100 30 30 180 Pi11 - Maximum primary circuit water pump speed in Heat % 0 100 100 100 181 Pi12 - Minimum primary circuit water pump setpoint sp... C -50 99,9 20 20 182 Pi13 - Proportional band primary circuit water pump i... C -25,5 25,5 18 18 183 Pi14 - Fan speed setpoint for primary circuit water p... % 0 100 80 80 184 Pi15 - Surge current time primary circuit water pump... sec 0 255 2 2 185 Pi16 - Enable primary circuit water pump anti-lock fu... num 0 1 0 0 186 Pi17 - Time primary circuit water pump not active for... ore 0 255 50 50 187 Pi18 - Time primary circuit water pump on for anti-lock sec 1 255 10 10 188 Pi19 - Enable primary circuit water pump anti-freeze... num 0 1 0 0 189 Pi20 - Primary circuit water pump regulator setpoint... C -50 99,9 8 8 190 Pi21 - Primary circuit water pump regulator hysteresi... C 0 25,5 2 2 191 Pi22 - Enable primary circuit water pump on when anti... num 0 1 0 0 192 Pi23 - Fan speed hysteresis for primary circuit water... % 0 100 10 10 193 Pi24 - Fan speed hysteresis for primary circuit water... % 0 100 10 10 Group Name: Fi. Page 3/8

194 Fi00 - Enable recirculating fan num 0 1 0 0 195 Fi01 - Select recirculating fan function num 0 1 1 1 196 Fi02 - Recirculating fan regulator hysteresis in Cool C 0 25,5 2 2 197 Fi03 - Recirculating fan regulator hysteresis in Heat C 0 25,5 2 2 198 Fi04 - Enable Hot Start function num 0 1 1 0 199 Fi05 - Hot Start regulator set point C 0 99,9 38 38 200 Fi06 - Hot Start regulator hysteresis C 0 15 2 2 201 Fi07 - Post-ventilation time in Heat sec 0 255 10 10 202 Fi08 - Delay compressor on - recirculating fan on sec 0 255 10 10 Group Name: FE. 203 FE00 - Enable open system intercooler fan num 0 1 1 1 204 FE01 - Select open system intercooler fan function mode num 0 1 1 1 205 FE02 - Surge current time open system intercooler fan sec 0 60 2 2 206 FE03 - Enable open system intercooler fan on with com... num 0 1 0 0 207 FE04 - Cut-off open system intercooler fan bypass time sec 0 255 2 10 208 FE05 - Open system intercooler fan pre-ventilation ti... sec 0 255 15 20 209 FE06 - Open system intercooler fan pre-ventilation ti... sec 0 255 15 2 210 FE07 - Open system intercooler fan minimum speed in Cool % 0 100 50 22 211 FE08 - Open system intercooler fan average speed in Cool % 0 100 95 100 212 FE09 - Open system intercooler fan maximum speed in Cool % 0 100 100 100 213 FE10 - Select probe to regulate open system intercool... num 0 4 0 3 214 FE11 - Open system intercooler fan minimum setpoint s... C/Bar -50 99,9 14 20 215 FE12 - Open system intercooler fan maximum speed diff... C/Bar -50 99,9 5,5 5 216 FE13 - Open system intercooler fan proportional band... C/Bar 0 25,5 3,5 5 217 FE14 - Open system intercooler fan maximum speed hyst... C/Bar 0 25,5 1 0 218 FE15 - Open system intercooler fan hysteresis cut-off... C/Bar 0 25,5 1 1 219 FE16 - Open system intercooler fan differential cut-o... C/Bar 0 25,5 2 1 220 FE17 - Open system intercooler fan minimum speed in Heat % 0 100 50 22 221 FE18 - Open system intercooler fan average speed in Heat % 0 100 95 100 222 FE19 - Open system intercooler fan maximum speed in Heat % 0 100 100 100 223 FE20 - Select probe to regulate open system intercool... num 0 4 0 3 224 FE21 - Open system intercooler fan minimum setpoint s... C/Bar -50 99,9 5,5 19 225 FE22 - Open system intercooler fan maximum speed diff... C/Bar -50 99,9 1,7 5 226 FE23 - Open system intercooler fan proportional band... C/Bar 0 25,5 1 5 227 FE24 - Open system intercooler fan maximum speed hyst... C/Bar 0 25,5 0,5 0 228 FE25 - Open system intercooler fan hysteresis cut-off... C/Bar 0 25,5 0,5 1 229 FE26 - Open system intercooler fan differential cut-o... C/Bar 0 25,5 1 1 230 FE27 - Enable open system intercooler fan on during d... num 0 1 0 0 231 FE28 - Open system intercooler fan switch on setpoint... C/Bar -50 99,9 19 19 232 FE29 - Open system intercooler fan switch-on hysteres... C/Bar 0 25,5 1 1 233 FE30 - Select probe to regulate open system intercool... num 0 3 1 1 Group Name: PE. 234 PE00 - Enable open system water pump circuit num 0 1 0 0 Group Name: Hi. 235 Hi00 - Enable primary intercooler heaters for anti-fr... num 0 1 1 1 236 Hi01 - Enable primary intercooler heaters regulator o... num 0 1 0 1 237 HI02 - Enable primary intercooler heaters for integra... num 0 1 0 0 238 Hi03 - Enable force heaters on during defrost num 0 1 0 1 Page 4/8

239 Hi04 - Number of primary intercooler heaters num 1 2 1 1 240 Hi05 - Select probe to regulate primary intercooler h... num 0 1 1 1 241 Hi06 - Primary intercooler heaters regulator setpoint... C -10 [243] 7 [242] 4 5 242 Hi07 - Primary intercooler heaters regulator maximum... C -10 [243] 99,9 7 7 243 Hi08 - Primary intercooler heaters regulator minimum... C -50 7 [242] -10-10 244 Hi09 - Primary intercooler heaters regulator hysteres... C 0 25,5 0,5 1 245 Hi10 - Primary intercooler heaters dynamic differenti... C -50 99,9 10 10 246 Hi11 - Primary intercooler heaters maximum dynamic di... C/Bar 0 25,5 25,5 25,5 247 Hi12 - Primary intercooler heaters dynamic differenti... C -50 99,9 5 5 248 Hi13 - Primary intercooler heaters regulator hysteres... C/Bar 0 25,5 1 1 249 Hi14 - Enable primary intercooler heaters digital dyn... num 0 1 1 1 250 Hi15 - Primary intercooler heater 2 switch-on setpoin... C/Bar 0 25,5 3 3 Group Name: HE. 251 HE00 - Enable open-system intercooler heaters for ant... num 0 1 0 0 252 HE01 - Enable primary open-system intercooler heaters... num 0 1 0 0 253 HE02 - Select probe to regulate primary open-system i... num 0 1 1 1 254 HE03 - Open-system intercooler heaters switch-on setp... C -10 [256] 7 [255] 4 4 255 HE04 - Primary open-system intercooler heaters regula... C -10 [256] 99,9 7 7 256 HE05 - Primary open-system intercooler heaters regula... C -50 7 [255] -10-10 257 HE06 - Open-system intercooler heaters regulator hyst... C 0 25,5 1 1 Group Name: HA. 258 HA00 - Enable auxiliary heater num 0 1 0 0 259 HA01 - Auxiliary heaters regulator setpoint C -25,5 25,5 2 2 260 HA02 - Auxiliary heaters regulator hysteresis C 0 25,5 1 1 Group Name: br. 261 br00 - Enable boiler num 0 1 0 0 262 br01 - Enable boiler during heating only num 0 1 0 0 263 br02 - Enable boiler digital dynamic differential num 0 1 1 1 264 br03 - Boiler dynamic differential setpoint C -50 99,9 10 10 265 br04 - Boiler proportional band dynamic differential C -50 99,9 5 5 266 br05 - Maximum boiler dynamic differential C/Bar 0 25,5 25,5 25,5 267 br06 - Boiler regulator hysteresis C/Bar 0 25,5 2 2 Group Name: df. 268 df00 - Enable defrost function num 0 1 1 0 269 df01 - Setpoint for enable interval count between def... C/Bar -50 99,9 2,5 5,5 270 df02 - Disable defrost setpoint C/Bar -50 99,9 13 30 271 df03 - Cumulative time between defrost cycles min 0 255 20 20 272 df04 - Delay compressor-valve-compressor start defrost sec 0 255 0 30 273 df05 - Delay compressor-valve-compressor end defrost sec 0 255 10 30 274 df06 - Drip time sec 0 255 40 30 275 df07 - Maximum defrost time min 0 255 5 3 276 df08 - Enable dynamic defrost differential num 0 1 0 0 277 df09 - Maximum dynamic defrost differential C/Bar -25,5 25,5 2 2 278 df10 - Dynamic defrost differential setpoint C -50 99,9 10 10 279 df11 - Defrost proportional band dynamic differential C -25,5 25,5-5 -5 280 df12 - Select probe to enable interval count between... num 0 4 0 4 281 df13 - Select probe to disable defrost num 0 4 0 4 282 df14 - Setpoint to clear cumulative time between defr... C/Bar -50 99,9 13 19 Page 5/8

Group Name: ds. 283 ds00 - Enable dynamic temperature control differential num 0 1 0 0 284 ds01 - Temperature control proportional band dynamic... C -50 99,9 5 5 285 ds02 - Temperature control proportional band dynamic... C -50 99,9 5 5 286 ds03 - Maximum temperature control dynamic differenti... C -50 99,9 5 5 287 ds04 - Maximum temperature control dynamic differenti... C -50 99,9 5 5 288 ds05 - Temperature control dynamic setpoint different... C -50 99,9 15 15 289 ds06 - Temperature control dynamic setpoint different... C -50 99,9 22 22 290 ds07 - Enable temperature control digital dynamic dif... num 0 1 0 0 Group Name: Ad. 291 Ad00 - Enable machine function without accumulation num 0 1 0 0 292 Ad01 - Type of accumulation compensation num 0 2 0 0 293 Ad02 - Constant accumulation compensation num 0 25,5 2 2 294 Ad03 - Accumulation compensation differential C 0 25,5 0,5 0,5 295 Ad04 - Accumulation compensation block setpoint in Cool C -50 99,9 4 4 296 Ad05 - Accumulation compensation block setpoint in Heat C -50 99,9 50 50 297 Ad06 - Time compressor on for accumulation compensati... sec*10 0 255 24 24 298 Ad07 - Compressor on reference time for accumulation... sec*10 0 255 18 18 Group Name: AF. 299 AF00 - Enable heat pump function in anti-freeze num 0 1 0 0 300 AF01 - Water pump regulator setpoint for heat pump fu... C/Bar -50 99,9 8 8 301 AF02 - Heat pump regulator setpoint in anti-freeze C/Bar -50 99,9 5 5 302 AF03 - Heat pump block setpoint in anti-freeze C/Bar -50 99,9 12 12 Group Name: PL. 303 PL00 - Enable power limitation function num 0 1 0 0 304 PL01 - Select probe for power limitation num 0 3 1 1 305 PL02 - High pressure setpoint for power limitation Bar -50 99,9 40 40 306 PL03 - Low pressure setpoint for power limitation Bar -50 99,9 3 3 307 PL04 - High water temperature setpoint for power limi... C -50 99,9 50 50 308 PL05 - Low water temperature setpoint for power limit... C -50 99,9 5 5 309 PL06 - External temperature setpoint for power limita... C -50 99,9 10 10 310 PL07 - External temperature setpoint for power limita... C -50 99,9 3 3 311 PL08 - Power limitation proportional band C/Bar 0 25,5 5 5 Group Name: AL. 312 AL00 - Time interval in which alarm events are counted min 1 99 60 60 313 AL01 - Number of low pressure alarms num 0 255 3 0 314 AL02 - Low pressure alarm bypass time sec 0 255 120 5 315 AL03 - Number of high pressure alarms num 0 255 0 0 316 AL04 - Enable flow switch time for primary circuit ma... sec*10 0 255 2 1 317 AL05 - Flow switch bypass time after primary circuit... sec 0 255 15 20 318 AL06 - Enable flow switch time for primary circuit au... sec 0 255 2 3 319 AL07 - Disable flow switch time for primary circuit a... sec 0 255 15 5 320 AL08 - Number of compressor thermal switch alarms num 0 255 1 255 321 AL09 - Bypass compressor thermal switch alarm time sec 0 255 1 0 322 AL10 - Number of open-system intercooler fan thermal... num 0 255 1 255 323 AL11 - Number of primary circuit anti-freeze alarms num 0 255 1 0 324 AL12 - Primary circuit anti-freeze regulator setpoint... C -50 99,9 4 3 325 AL13 - Primary circuit anti-freeze regulator hysteres... C 0 25,5 2 5 Page 6/8

326 AL14 - Enable force recirculating fan on during prima... num 0 1 0 0 327 AL15 - Primary circuit anti-freeze alarm bypass time min 0 255 1 0 328 AL16 - Enable gas low in plant alarm num 0 1 0 0 329 AL17 - Gas low in plant alarm bypass time min 0 255 5 10 330 AL18 - Gas low in plant alarm differential C 0 25,5 2 0 331 AL19 - Time gas low in plant before alarm min 0 255 30 120 332 AL20 - Enable low pressure alarm during defrost num 0 1 0 0 333 AL21 - High temperature alarm regulator setpoint from... C -50 99,9 90 90 334 AL22 - High temperature alarm regulator hysteresis fr... C 0 25,5 2 1 335 AL23 - High temperature time per alarm sec*10 0 255 30 20 336 AL24 - Low pressure alarm regulator setpoint from ana... Bar -50 99,9 2-50 337 AL25 - High pressure alarm regulator setpoint from an... Bar -50 99,9 42 90 338 AL26 - Low pressure alarm regulator hysteresis from a... Bar 0 25,5 2 10 339 AL27 - High pressure alarm regulator hysteresis from... Bar 0 25,5 2 10 340 AL28 - Low pressure alarm bypass time from analogue i... sec 0 255 10 0 341 AL29 - Number of low pressure alarms from analogue input num 0 255 2 0 342 AL30 - Time compressor 1 on before maintenance warning ore*100 0 255 255 255 343 AL31 - Time compressor 2 on before maintenance warning ore*100 0 255 255 255 344 AL32 - Time pump 1 on before maintenance warning ore*100 0 255 255 255 345 AL33 - Time pump 2 on before maintenance warning ore*100 0 255 255 255 346 AL34 - Maximum number of historical events per alarm... num 0 99 99 99 347 AL35 - Number of primary intercooler fan thermal swit... num 0 255 1 1 348 AL36 - Time flow switch on before open-circuit manual... sec*10 0 255 2 2 349 AL37 - Flow switch bypass time after open-circuit pum... sec 0 255 15 15 350 AL38 - Time flow switch on before open-circuit automa... sec 0 255 2 2 351 AL39 - Time low switch off before open-circuit automa... sec 0 255 15 15 352 AL40 - Number of primary circuit pump thermal switch... num 0 255 2 2 353 AL41 - Number of open-system pump thermal switch alarms num 0 255 2 2 354 AL42 - Number of compressor oil pressure switch alarms num 0 255 1 1 355 AL43 - Number of high pressure alarms from analogue i... num 0 255 0 0 356 AL44 - Number of open-system anti-freeze alarms num 0 255 1 1 357 AL45 - Open-system circuit anti-freeze regulator setp... C -50 99,9 4 4 358 AL46 - Open-system circuit anti-freeze regulator hyst... C 0 25,5 2 2 359 AL47 - Open-system circuit anti-freeze alarm bypass time min 0 255 1 1 360 AL48 - Compressor oil pressure switch alarm bypass time sec 0 255 1 1 Group Name: Vis. 497 Vis.St0 - Folder AI visibility - 0 0 0 0 498 Vis.St1 - Folder DI visibility - 0 0 0 0 499 Vis.St2 - Folder AO visibility - 0 0 0 0 500 Vis.St3 - Folder DO visibility - 0 0 0 0 501 Vis.St4 - Folder SP visibility - 0 0 0 0 502 Vis.St5 - Folder SR visibility - 0 0 0 0 503 Vis.St6 - Folder HR visibility - 0 0 0 0 504 Vis.Pa0 - Folder PAR visibility - 0 0 0 0 505 Vis.Pa1 - Folder FNC visibility - 0 0 0 0 506 Vis.Pa2 - Folder PASS visibility - 0 0 0 0 507 Vis.Pa3 - Folder EU visibility - 0 0 0 0 508 Vis.SSp0 - Folder SP\COOL visibility - 0 0 0 0 Page 7/8

509 Vis.SSp1 - Folder SP\HEAT visibility - 0 0 0 0 510 Vis.SSr0 - Folder SR\COOL visibility - 0 0 0 0 511 Vis.SSr1 - Folder SR\HEAT visibility - 0 0 0 0 512 Vis.PP0 - Folder PAR\CF visibility - 0 0 0 0 513 Vis.PP1 - Folder PAR\UI visibility - 0 0 0 0 514 Vis.PP2 - Folder PAR\TR visibility - 0 0 0 0 515 Vis.PP3 - Folder PAR\ST visibility - 0 0 0 0 516 Vis.PP4 - Folder PAR\CP visibility - 0 0 0 0 517 Vis.PP5 - Folder PAR\PI visibility - 0 0 0 0 518 Vis.PP6 - Folder PAR\FI visibility - 0 0 0 0 519 Vis.PP7 - Folder PAR\FE visibility - 0 0 0 0 520 Vis.PP8 - Folder PAR\PE visibility - 0 0 0 0 521 Vis.PP9 - Folder PAR\HI visibility - 0 0 0 0 522 Vis.PP10 - Folder PAR\HE visibility - 0 0 0 0 523 Vis.PP11 - Folder PAR\HA visibility - 0 0 0 0 524 Vis.PP12 - Folder PAR\BR visibility - 0 0 0 0 525 Vis.PP13 - Folder PAR\DF visibility - 0 0 0 0 526 Vis.PP14 - Folder PAR\DS visibility - 0 0 0 0 527 Vis.PP15 - Folder PAR\AD visibility - 0 0 0 0 528 Vis.PP16 - Folder PAR\AF visibility - 0 0 0 0 529 Vis.PP17 - Folder PAR\PL visibility - 0 0 0 0 530 Vis.PP18 - Folder PAR\AL visibility - 0 0 0 0 531 Vis.PF0 - Folder FNC\DEF visibility - 0 0 0 0 532 Vis.PF1 - Folder FNC\TA visibility - 0 0 0 0 533 Vis.PF2 - Folder FNC\ST visibility - 0 0 0 0 534 Vis.PF3 - Folder FNC\CC visibility - 0 0 0 0 535 Vis.PF4 - Folder FNC\EUR visibility - 0 0 0 0 536 Vis.PFCC0 - Folder FNC\CC\UL visibility - 0 0 0 0 537 Vis.PFCC1 - Folder FNC\CC\DL visibility - 0 0 0 0 538 Vis.PFCC2 - Folder FNC\CC\FR visibility - 0 0 0 0 Page 8/8