Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Similar documents
3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Series VP3145/3165/3185

Pilot Operated 2 Port Solenoid Valve for Dry Air

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VP3145/3165/3185

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Vacuum / Release Unit

3 Port Solenoid Valve

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Series VQ Port Solenoid Valve

4 Port Solenoid Valve

0.35 W (Without light)

Series SV1000/2000/3000/4000

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

4 Port Solenoid Valve

3 Port Solenoid Valve

3 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

High Pressure Coolant Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber Seal VP300/500/700

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

3 Port 3 Position Valve

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Coolant Valve. Air Operated/External Pilot Solenoid

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Solenoid Valve

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

3 Port Air Operated Valve

Series VQZ1000/2000/3000 Single Unit

3 Port Direct Operated Poppet Solenoid Valve SeriesVKF300

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Manifold Specifications

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Exclusively for air pressure system and air-hydro circuit control

Series SYA3000/5000/7000

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Series SYA3000/5000/7000

5 Port Pilot Solenoid Valve Rubber Seal

5 Port Solenoid Valve Plug Lead Type

Series SYA3000/5000/7000

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series SYA3000/5000/7000

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

5 Port Air Operated Valve

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

5 Port Solenoid Valve

Series SYJ300/500/700

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

1 1/4 (32A) to 2 (50A) added.

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

Coolant Valve. VNC Series. Cylinder actuation by pilot air

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Solenoid Valve

5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4.

5 Port Solenoid Valve

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

Transcription:

Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing 360 rotation of 2 () entry direction (in 90 increments) Type 20 and 21 vailable in vacuum applications (Ð101.2 kpa) (Valve leakage: 0.03 cm 3 /s He or less) Can be used in vacuum/release circuits Universal porting N.C./N.O. type can be switched by supplying air to port 1 (P) or 3 (R). 2 way valves and selector valves can also be freely used. Type S42 1(P) Type 40 3(R) Easy manual operation Type 42 Since manual overrides are located in 2 directions, on the top and on the side of the valve, manual override operation is possible and is unaffected by mounting space and piping direction, etc. VV061 V100 S070 VQD VKF VK VT VS Ozone resistant (Series 80-) 5 FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing for use even in ozone environments. 9 1569

3 Port Solenoid Valve Direct Operated Poppet Type Series VKF300 How to Order Valves Body ported (Single type) Body ported (For manifold) Base mounted VKF332 VKF333 VKF334 Rated voltage 50 1 100 VC, 60 Hz 50 2 200 VC, 60 Hz 3 50 110 VC, 60 Hz 4 50 220 VC, 60 Hz 5 24 VDC 6 12 VDC 7 50 240 VC, 60 Hz 9 Other Option Electrical entry G: Grommet (Lead wire length: 300 mm) 5 G M5 5 G M5 5 G 01 H: Grommet (Lead wire length: 600 mm) Port size M5 01 D: DIN terminal DO: DIN terminal (Without connector) M5 x 0.8 Rc 1/8 ( port) Nil F N T (With bracket) Thread type RC G NPT NPTF For the port size 01 only. VKF33 2 3 VKF33 2 3Y VKF33 2 3E VKF33 2 3V VKF33 2 3W VKF334 VKF334Y VKF334E VKF334V VKF334W V Y W E Valve option Flow Characteristics/Mass Body ported Base mounted (With subplate) Valve model Operating pressure range (MPa) 0 to 0.7 101.2 KPa to 0.1 0 to 0.7 101.2 kpa to 0.1 For vacuum For low power consumption For vacuum/low power consumption Continuous duty type pplicable voltage: 12 and 24 VDC Port size M5 x 0.8 Rc 1/8 Note 1) VKF33 : dd 10 g to each when equipped with bracket. Light/Surge voltage suppressor Nil S Z None With surge voltage suppressor With light/surge voltage suppressor (Type D only) Since the indicator light is built in the connector, thus, DOZ is not available. Port size 01 Nil Flow characteristics 1 2 (P ) 2 3 ( R) C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv 0.67 0.10 0.15 0.41 0.39 0.11 0.56 0.13 0.13 0.32 0.25 0.09 0.56 0.13 0.13 0.32 0.25 0.09 0.67 0.10 0.15 0.41 0.39 0.11 0.56 0.13 0.13 0.32 0.25 0.09 0.68 0.13 0.15 0.59 0.31 0.14 0.56 0.13 0.13 0.32 0.25 0.09 0.56 0.13 0.13 0.32 0.25 0.09 0.68 0.13 0.15 0.59 0.31 0.14 0.56 0.13 0.13 0.32 0.25 0.09 Rc 1/8 (With sub-plate) Without sub-plate Mass (g) DIN Grommet terminal 80 (1) 120 90 (1) 130 1570

3 Port Solenoid Valve Direct Operated Poppet Type Series VKF300 Standard Specifications JIS Symbol () 2 Body ported Base mounted Valve specifications Electricity specifications Type of actuation Fluid mbient and fluid temperature Response time (at 0.5 MPa) (1) Lubrication Mounting orientation Impact/Vibration resistance (2) Enclosure Electrical entry Rated voltage llowable voltage fluctuation pparent power (C) Power consumption (DC) Surge voltage suppressor Indicator light C DC Inrush Holding W/o indicator light W/ indicator light C DC C DC Direct operated type 2 position single solenoid ir Max. 50 C 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, If lubricated.) Unrestricted 300/50 m/s 2 Dustproof Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 V 6, 12, 24, 48 V ±10% of rated voltage 9.5 V/50 Hz, 8 V/60 Hz 7 V/50 Hz, 5 V/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC or less) Neon bulb LED Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20 C, at rated voltage, without surge voltage suppressor) * When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time. Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) VV061 V100 S070 VQD VKF VK Construction VT 1 3 (P) (R) q t o r e VS y u i 1(P) 2() 3(R) w P R Component Parts No. q w e r t y u i Description Solenoid coil assembly Sub-plate Body Spool/Sleeve Return spring Bracket assembly Gasket assembly (With mounting screw) Material Ñ luminum die-casted luminum die-casted luminum Resin Stainless steel Steel Ñ Note For VKF334: VKF300-S-01 For VKF332: VKF300-13-2 For VKF333: VKF300-11-2 For VKF334: VKF300-11-1 o Bushing assembly Resin 3 For VKF33 4: VKF300-6-1 2 sets per unit required 1571

Series VKF300 Dimensions: Single Type Body ported Grommet: VKF332 - G- M5 01 DIN terminal: VKF332 - D- M5 01 17 Rc 1/8, M5 x 0.8 2()port ( 300 (Lead wire length) 59 68 1 32 2.3 18.5 20.5 Max..10 71.5 pplicable cable O.D. 4 to 6.5 32 2.3 Pg.7 28.5 27 29 mpm 25 2x 3.5 (Mounting hole) 63 58 50.5 27 P R 0.5 0.5 2xM5x0.8 1(P), 3(R) port 13.7 24 Refer to grommet type for other dimensions. Base mounted Grommet: VKF334 - G-01 DIN terminal: VKF334 - D-01 33.5 16.7 10 12.7 20 26 4 18.5 20.5 32 3 26 4 48.5 3 18.5 20.5 27 mpm 32 3 59 68 7.5 12 2x 4.3 (Mounting hole) (300 (Lead wire length) Max. 10 71.5 pplicable cable O.D. 4 to 6.5 Pg.7 78 70.5 P R 7.5 43.5 12 P R 43.5 13.5 11 33.5 3xRc1/8 1(P), 2(), 3(R) port 13.5 11 Refer to grommet type for other dimensions. 1572

3 Port Solenoid Valve Direct Operated Poppet Type Series VKF300 How to Order Manifold Body ported Common SUP/Common EXH Type 20: Body ported ( port top ported) 2() port: Rc 1/8, M5 x 0.8 How to Order VV3KF3 20 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Valve stations 01 1 station ááá 20 ááá 20 stations 05 Option Nil F Thread type Nil Rc 00F G 00N NPT 00T NPTF None With bracket (Not mounted) pplicable solenoid valve VKF333 - -M5 VKF333 - -01 pplicable blanking plate assembly VK300-42-1 Bracket VK300-43-1 Common SUP/Individual EXH Type 21: Body ported ( port top ported) 2() port: Rc 1/8, M5 x 0.8 3(R) port: Rc 1/8 Base mounted Common SUP/Common EXH Type 40: Base mounted ( port bottom ported) How to Order VV3KF3 21 05 1(P) port: Rc 1/8 1(P) port: Rc 1/8 3(R) port: Rc 1/8 2() port: Rc 1/8 How to Order Valve stations 01 1 station ááá 20 ááá 20 stations VV3KF3 40 05 01 Valve stations 01 1 station ááá 20 ááá 20 stations 01 Port size Rc 1/8 Thread type Nil Rc F G N NPT T NPTF Thread type Nil Rc 00F G 00N NPT 00T NPTF pplicable solenoid valve VKF333 - -M5 VKF333 - -01 pplicable blanking plate assembly VK300-42-1 pplicable solenoid valve VKF334 - pplicable blanking plate assembly VK300-42-1 Bracket VK300-43-1 VV061 V100 S070 VQD VKF VK VT VS Type 42: Base mounted ( port side ported) How to Order VV3KF3 42 05 01 Nil F Option None With bracket (Not mounted) pplicable solenoid valve VKF334 - pplicable blanking plate assembly VK300-42-1 2() port: Rc 1/8 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Type S42 (Solenoid on same side as port ) 2() port: Rc 1/8 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Solenoid direction Nil S Solenoid on opposite port Solenoid on same side as port Port size 01 C4 C6 Valve stations 01 1 station Thread type Nil Rc F G N NPT T NPTF Rc 1/8 4 cassette 6 cassette ááá ááá 20 20 stations 1573

Series VKF300 Dimensions: Manifold Body ported Type 20 Manifold Common SUP, Common EXH/Top Ported Grommet: G 4xRc1/8 1(P), 3(R) port DIN terminal: D pplicable cable O.D. 4 to 6.5 67.5 59 19 17 2 P R 2x 4.5 (Mounting hole) R P 7 20 34 Max. 10 Pg.7 mpm 78.5 71 Indicator light (Type DZ only) 4 x Rc 1/8 1(P), 3(R) port n x Rc 1/8, M5 x 0.8 2() port 4 x M3 x 0.5 depth 6 (Bracket mounting screw) 1 P=19 13.5 L2 L1 4 2x 4.5 (Bracket mounting hole) (300 (Lead wire length) 7 8 26 47.5 2.3 71.5 47.5 7 8 7 20 34 L L1 L2 L3 n 7 L3 7 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 35 27 13 54 46 32 73 65 51 92 84 70 111 103 89 130 122 108 149 141 127 168 160 146 187 179 165 206 198 184 225 217 203 244 236 222 263 255 241 282 274 260 301 293 279 320 312 298 339 331 317 358 350 336 377 369 355 396 388 374 67.5 59 32 17 2 P 1 P=1913.5 L2 5.5 L1 5 47.5 11 49 15.5 20 25 49 L Dimension n: Stations Type 21 Manifold n x Rc 1/8, M5 x 0.8 2() port nxrc1/8 3(R) port Common SUP, Individual EXH/Top Ported P 2x 4.5 (Mounting hole) ( 300 (lead wire length) Grommet: G 2xRc1/8 1(P) port 19 35 Pg.7 DIN terminal: D Max. 10 71.5 mpm pplicable cable O.D. 4 to 6.5 78.5 71 Indicator light (Type DZ only) 47.5 11 2 x Rc 1/8 1(P) port 19 35 R R 11 20 26 P=19 19 L Dimension L L1 L2 n 1574 n: Stations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 38 27 57 46 76 65 95 84 114 103 133 122 152 141 171 160 190 179 209 198 228 217 247 236 266 255 285 274 304 293 323 312 342 331 361 350 380 369 399 388

3 Port Solenoid Valve Direct Operated Poppet Type Series VKF300 Base mounted Type 40 Manifold Common SUP, Common EXH/Bottom Ported 67.5 59 20.5 1 P R L2 L1 4 x M3 x 0.5, depth 6 (Bracket mounting screw) P=19 13.5 P R 5 20.5 7 L3 7 5 nxrc1/8 2() port 4x 4.5 (Bracket mounting hole) P=19 16 2x 4.5 (Mounting hole) 25 30 (300 (leadwire length) 53.5 Grommet: G 4xRc1/8 1(P), 3(R) port 1.5 10.5 49.5 31 8 23 39 2.3 Pg.7 Max. 10 71.5 mpm 83 75.5 19.5 23 8 DIN terminal: D pplicable cable O.D. 4 to 6.5 Indicator light (Type DZ only) 10.5 49.5 4 x Rc 1/8 1(P), 3(R) port 23 39 8 1.5 VV061 V100 S070 VQD VKF VK VT VS L Dimension L L1 L2 L3 n n: Stations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 37 27 13 56 46 32 75 65 51 94 84 70 113 103 89 132 122 108 151 141 127 170 160 146 189 179 165 208 198 184 227 217 203 246 236 222 265 255 241 284 274 260 303 293 279 322 312 298 341 331 317 360 350 336 379 369 355 398 388 374 1575

Series VKF300 Dimensions: Manifold Base mounted Type 42 Manifold Common SUP, Common EXH/Side Ported Grommet: G DIN terminal: D 4xRc1/8 1(P), 3(R) port pplicable cable O.D. 4 to 6.5 67.5 59 20.5 nxrc1/8 2() port P R L2 L1 P=19 P=19 2x 4.5 (Mounting holes) 14 P R 5 (300 (Lead wire length) 49.5 11.5 18 39 8.5 11.5 Pg.7 Max. 10 71.5 mpm 83 75.5 Indicator light (Type DZ only) 49.5 4xRc1/8 1(P), 3(R) port 11.5 18 39 8.5 11.5 18 25 31 53.5 P=19 14.5 Type S42 Manifold Common SUP, Common EXH/Side Ported: Same direction as solenoid L1 L2 5 P=19 14 Grommet: G 49.5 11.5 8.5 DIN terminal: D 49.5 11.5 8.5 67.5 59 18.5 2 R P R P 2x 4.5 (Mounting hole) 11.5 18 37 71.5 11.5 18 37 ( 300 (lead wire length) 4xRc1/8 1(P), 3(R) port Pg.7 MX.10 mpm Indicator light (Type DZ only) 75.5 83 4 x Rc 1/8 1(P), 3(R) port nxrc1/8 2() port pplicable cable O.D. 4 to 6.5 18 25 31 53.5 P=19 20 L Dimension 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 38 57 76 95 114 133 152 171 190 209 228 247 266 285 304 323 342 361 380 399 L2 28 47 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 n L 1576 n: Stations

Series VKF300 Specific Product Precautions 1 Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions. ø9 Manual Override Operation Warning Connected actuator is started by manual operation. Use the manual override after confirming that there is no danger. Non-locking push type (Tool required) ø5 There are manual overrides in 2 directions, on the top and on the side (solenoid side). By pressing either of the manual overrides in the direction of the arrow (R) until it stops (approx. 1 mm), it will turn ON, and it turns OFF when released. Caution Mounting of Valves fter confirming the gasket is correctly placed under the valve, securely tighten the bolts with the proper torque shown in the table below. Proper tightening torque (N m) 0.6 to 0.8 Mounting screw Bushing C 12 VDC or less 24 VDC or more Light/Surge Voltage Suppressor Caution Without indicator light With indicator light Without indicator light With indicator light Without indicator light With indicator light (+) Red Precautions on connection of 24 V or more DC For the grommet type, connect the positive (+) side to the red lead wire and connect the negative ( ) side to the black lead wire. For the DIN terminal, connect the positive (+) side to the connector s no.1 terminal and connect the negative ( ) side to the no.2 terminal. (See the markings on the terminal block.) For 12 V or less DC, positive (+) and negative ( ) can be connected in either direction. Grommet type Grommet type (G) Black ( ) Varistor Varistor None None Diode None Coil Coil Coil Red (+) Black ( ) Surge voltage suppressor DIN terminal type (D) Neon bulb Varistor Varistor Diode Varistor Varistor Diode Coil Coil Coil Coil Coil Coil Symbol S Z S Z S Z VV061 V100 S070 VQD VKF VK VT VS The bushing may be damaged if the tightening torque of 0.8 N m is exceeded. In the event that damage does occur, be sure to replace the bushing. DIN terminal type SUP Block bushing assembly no. VKF300-6-1 2 sets per unit are required. Marking Indicator light (Built in the connector) Marking For C and 12 V or less DC Surge voltage suppressor (Built in the terminal block) For 24 V or more DC 1577

Series VKF300 Specific Product Precautions 2 Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions. Warning How to Wire DIN Terminal Connection 1. Loosen the set screw and pull out the connector from the terminal block of the solenoid. 2. fter removing the holding screw, insert a flat head screwdriver, etc. into the notch on the bottom of the terminal block and pry it up, separating the terminal block and the housing. 3. Loosen the terminal screws (slotted screws) on the terminal block, insert the core of the lead wire into the terminal in accordance with the prescribed connection method, and attach securely with the terminal screws. 4. Tighten the ground nut to secure the wire. Change of electrical entry (Orientation) fter separating terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). In the case of indicator light, avoid damaging the light with lead wire. Precautions The connector should be inserted and pulled out in a straight line without tilting diagonally. pplicable cable O.D.: ø4 to ø6.5 (Reference) 0.5 mm 2 2 core and 3 core wires equivalent to JIS C 3306 Circuit with indicator light C Circuit diagram NL: Neon bulb R: Resistor 12 VDC or less Circuit diagram LED: Light emitting diode R: Resistor How to Calculate the Flow Rate 24 VDC or more Circuit diagram D: Protective diode LED: Light emitting diode R: Resistor For obtaining the flow rate, refer to front matters 44 to 47. Ground nut Holding screw Housing Grommet (Rubber) Washer (Voltage symbol) Refer to the table below. Terminal screw (3 locations) (Position for light mounting) Terminal block Shaved part Connector part no. VK300-82-1 Part no. for connector with indicator light Rated voltage 100 VC 200 VC 24 VC 6 VDC 12 VDC 24 VDC 48 VDC Voltage symbol 1 2 3 LW06 LW2 LD4 LD8 Part no. VK300-82-2-01 VK300-82-2-02 VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 1578