GETTING STARTED WITH IN-WALL DIMMER SWITCH

Similar documents
INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

MOONRING 1.5 MOONRING 3

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Wireless Dimmer Installation and User Guide

poollux Power plx-pw60 & plx-pw100

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION INSTRUCTION Bollard Light 12V

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS

Spun Bay Installation Standard Version (non dimmable), Hook Mount

MAXLITE RKT LED Retrofit Kit

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

Captivate Illuminated Mirror Light

WASP-P PRESSURE SENSOR

Door Station - Interior Setup Guide

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Wet Rated Batten LED Luminaire

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

LAL SERIES LED LUMINAIRE

LED DayLite Micro. User Guide Ver

INSTALLATION. **Microprocessor Status LED:

HP10325 KIT. AMP Wireless Air Controls

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Installation Instructions

LED DayLite WireLess Mini

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

INSTEON Range Extender Owner s Manual

CSD Series Current Devices Split Core

NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

2-Way Dimmer (1 Gang)

Dimmer / 2-Way Dimmer

Installation Instructions

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Cable Cubby 1202 and 1402 Installation Guide

2-Way Dimmer (1 Gang)

Air Lift Performance 3S

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

CHARGING FOLIO. for iphone 6 USER GUIDE

HOMELINK DOOR OPENER KIT

Assembly and Operation Manual

User Manual. E11-N1EA LED Wireless RGBW A19 Bulb. LED + Smart Control

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Cable Cubby 650 UT Installation Guide

Installation Instructions: Eco Linear High Bay

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Magnetic Transformer

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

Model Numbers SAVI-NOTE75, SAVI-NOTE150

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions CRAFT M/L

WARNING / AVERTISSEMENT

Retractor SM Installation Guide

SAVE THESE INSTRUCTIONS

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Owner s Manual Hydro-X Xtreme Xtractor

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

System 350 S350C Temperature Slave Stage Module

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Cable Cubby 1200 and 1400 Installation Guide

EMIU 720W Mini Inverter

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

P


960 Montage sur staff préfabriqué Mounting in prefabricated plaster

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

Plug-in Dimmer Socket Kit

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

QIS Hardwired Roller Shade User Manual

VA-4233-AGx Series Electric Valve Actuators

ebus Button Panel EU and MK Series Setup Guide

INSTALLATION INSTRUCTIONS

UB-2 2 Universal Button

Electric Vehicle Supply Equipment

Installation Instructions RF4510-EA

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Transcription:

GETTING STARTED WITH IN-WALL DIMMER SWITCH This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any purpose. This restriction does not limit the recipient's right to use information contained in the data if it is obtained from another source without restriction. 1

INDEX Section 1: Mounting your In-Wall Dimmer Switch Installation...03 In-Wall Dimmer Switch Connection Diagram...04 Other connection styles Diagrams...05 Section 2: Connecting to Smartee Adding In-Wall Dimmer Switch to Zigbee Network...06 Binding In-Wall Dimmer Switch...06 Section 3: Specs Specifications...07 Dimensions...08 Section 4: Security Instructions Security Guidelines...09 Page 02

1 1 MOUNTING YOUR IN-WALL DIMMER SWITCH Instructions Warnings! To reduce the risk of serious injury or death, turn power OFF before installing this product. (Ce produit doit être à la terre conformément à NEC et exigences locales.) This device must be installed by competent licensed electricians. (Cet appareil doit être installé par un électricien compétent autorisé.) This product must be grounded in accordance to NEC and Local requirements. (Ce produit doit être à la terre conformément à NEC et exigences lo-cales.) Caution! Using this product in any manner other than outlined in this document voids your warranty. Webee is not responsible for any damage incurred as a result of misuse or abuse of this product. (L'utilisation de ce produit de quelque autre manière que décrites dans le présent document annule votre garantie. Webee n'est pas responsable de tout dommage subi à la suite d'un détournement ou d'abus de ce produit.) Installation 1. Confirm that the intended installation location conforms to the following requirements: -Wall box must meet box size requirements specified by the NEC (National Electric Code.) -Installation will be completed according to national and local codes. -The load being controlled by the device does not exceed 800 W. 2. To avoid SERIOUS INJURY or DEATH, turn OFF the local electrical power feeding the switch location. To disconnect power, turn off the breaker or remove the fuse from the fuse box. Verify that there is no power present using a voltage meter or test light. 3. If you are replacing an existing switch, note which wires are the Ground, Circuit Feed (HOT), Load (Switch Leg), and Neutral, when removing the existing switch. 4. Prepare the wires for connection by stripping off the insulation 5/8 of an inch. 5. Connect the ZigBee HA Dimmer Switch Wires using the supplied wire nuts. Connect GREEN wire from switch to GROUND Connect BLACK wire from switch to HOT FEED Connect WHITE wire from switch to NEUTRAL Connect RED wire from switch to LOAD Page 03

Warnings! If a direct short is created between the RED wire and GROUND or NEUTRAL, the Dimmer Switch will be damaged and unusable. (Si un court direct est créé entre le fil rouge et SOL ou neutre, le commutateur de relais sera endommagée et inutilisable.) 6. Test all connections. Fold wires and push them neatly into the switch box. Align the Dimmer Switch in the switch box with the air gap switch oriented at the bottom of the Dimmer Switch. Using the supplied screws, secure the Dimmer Switch in the switch box. 7. Verify that the Air Gap switch is fully pushed in. Then turn ON circuit breaker or replace the fuse. 8. If the Dimmer Switch is installed properly the top LED will blink slowly for 100 seconds signifying that the device is working as a independent local device. 9. You should now be able to control the load by tapping the top button. In-Wall Dimmer Switch Connection Diagram Connect GREEN wire from switch to GROUND Connect BLACK wire from switch to HOT FEED Connect WHITE wire from switch to NEUTRAL Connect RED wire from switch to LOAD For Keypad Function (Below): Cap RED wire on switch, do not connect. Dimmer Page 04

Other connection styles diagrams Wiring for 3-way with load at the end of the circuit. Wiring for 3-way with load in the middle of the circuit. Dimmer Dimmer Wiring for 3-way with load at beginning of the circuit. Dimmer Page 05

2 1 CONNECTING TO SMARTEE Adding to Zigbee Network To join the In-Wall Dimmer Switch to the Smartee, follow these instructions: 1- Click on the Add Device on your App. 2-If the LED on the switch is blinking (scanning for a network to join) and the switch is within range of Smartee ZigBee HA network it will join the network. 3. If the LED is not blinking, press and hold the top button for two seconds. The LED should start blinking and scanning for a network to join. If the Dimmer Switch has not been captured onto a ZigBee HA network, it s LED will blink slowly upon power up for 100 seconds. Once it s top button is pressed the LED will indicate the Dimmer Switch Load ON/OFF status. If the load is connected properly the light should toggle states with every button tap. If after following these steps the In-Wall Dimmer Switch will not join the Smartee Zigbee network, factory default your switch and try again. To factory default your switch do as follows: 1. Disconnect power by pulling out the airgap switch. 2. While pushing the top button, power the switch on by pushing in the airgap switch. 3. After 2 seconds the status LED will turn ON. 4. Once the status LED is ON, release the button. Verify that the switch is wired correctly and powered up. The LED's should light up on the face plate. Button controlling Load: -Tap the button to turn the light ON/OFF. -Push and Hold the button to Dim the light. Binding Instructions One *Load Device can have multiple *Keypads bound to it. In order to bind a keypad to a load please follow the following steps: 1. Locate the Load Device and quickly tap the button 6 times, and on the 6th tap push and hold the button down for one second. The LED should start fast blinking. 2. Once the Led is fast blinking, tap the button once. 3. You now have one minute to locate the Keypad you wish to bind to the Load. 4. Once located, quickly tap the button 6 times, and on the 6th tap push and hold the button down for one second. The LED should start fast blinking. 5. Once the LED is fast blinking briefly push and hold the button. To test if this is working, tap the button on the Keypap device and it should toggle the Load. To bind another keypad to the Load, repeat steps 1-5 for the other Keypad with the same Load. To unbind a keypad from the Load, repeat steps 1-5 for the Keypad you wish to unbind. *Load Device = Device that is actually connected to the light via the Red Wire. *Keypad = Device that only has power and neutral and the red wire is capped off. Page 06

323 1 IN-WALL DIMMER SWITCH SPECS Electrical specifications Description Min Typ Max Unit Rated - - 120 VAC Input frequency - - 60 Hz Operating temperature -20º - 40º ºC Storage temperature -20º - 50º ºC Operating Humidity 0-90% RH (nonconndensing) Supported Loads -120 VAC 480 W Halogen -120 VAC 480 W Fluorescent -120 VAC 480 W Incandescent -120 VAC 480W Dimmable LED VAC Wireless RF Characteristics Description Min Typ Max Unit RF Channels - - 16 - TX Strength - - +18 dbm Range - >100 ft. (>30m) ft. Protocol Zigbee HA 1.2 Page 07

Dimensions Page 08

4 1 SAFETY INSTRUCTIONS Safety Guidelines -To be installed and/or used in accordance with appropriate electrical codes and regulations. -If you are unsure about any of these instructions, consult a qualified electrician. -Follow all guidelines carefully, if you have any questions contact us at support@webeelife.com. Warning: Make sure to veriffy that the devices you are connecting are within the electrical range of the In-Wall Dimmer Switch. Otherwise, it will be damage and will no longer function. Page 09

V1.0 REV. February, 2016 2015 Webee LLC, All rights reserved. The Webee logo, Smartee and Bees are trademarks or registered trademarks of Webee LLC 10