IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Similar documents
IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

Indoor Air Quality Meter

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

VELOCICALC Air Velocity Meter

DP-CALC TM Micromanometer

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

Rotating Vane Anemometer

Rotating Vane Anemometer

PRIMARY CALIBRATORS MODEL 4046/4146

Model 8026 Particle Generator

Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters

Model 8026 Particle Generator

Thermo-Anenometer Model Owner s Manual

ANALOG BALANCING TOOL MODELS ABT701, ABT703, ABT711, ABT713

AXD 530 MicroManometer

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

EXHAUST FAN FLOW METER

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

HIGH VOLTAGE DIGITAL AMMETER

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Infrared Thermocouple Probe

AXD 510 MicroManometer

This manual covers the following model:

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

SPC Series. Digital Scale. Operation Manual

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Table of Contents Up and Running... 1 Measurements... 2 Keypad Operation... 4 Displayed Items... 4 Placement for Monitoring/Testing...

PVI 60KW, PVI 82KW, PVI 95KW

EAGL 1-Touch Laser Level

Tachometer. English. Users Manual

User's Guide. CO 2 Meter. Model CO250

INSTALL GUIDE Silverado/Sierra L/6.2L

Hydronic Manometers. Hydronic Manometer. Model HM680. Owner s Manual

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

INSTALL GUIDE Jeep Wrangler JK 3.6L V6

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

"WHERE TUBING AND FITTINGS COME TOGETHER"

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Fifth Wheel Power Hitch Operations Manual

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Installation / Operation Instructions Sunnex ORION Series Exam Lights

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN


Installation Power Management Unit Battery Cables and Battery Harness

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

Broadband PowerShield. CP27U Models. User Manual

FR1118- P10. User s Manual

Coating Thickness Gauges

SIDESLIDE SERIES C-CLAMP 940K-010FI BOLT 940K-010RSC PICATINNY 940K-010PIC PRODUCT MANUAL

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

INSTALL GUIDE Ford F L

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

CALIBRATION TEST FIXTURES

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

SUNTURA SOLAR TRACKER

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

HR-20P Pneumatically Controlled Pressure Regulator

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

TABLE OF CONTENTS 11.0 WARRANTY

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

II DISTRIBUTION & SUBSTATION TYPE C

User's Manual. Earth Ground Resistance Tester. Model Introduction


BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

SUNTURA HD SOLAR TRACKER

User Guide. Model Insulation Tester / Megohmmeter. Introduction

323/324/325 Clamp Meter

Volatile Organic Compounds Probe Maintenance Application Note TSI-149

i400s Calibration Information Introduction

362 Clamp Meter. Users Manual

Thermometer model 00826

Installation Guide. Marine Filter SURT023M SURT024M

Megohmmeter Test Probe

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Humidity Monitor model 00619

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

Thermometer models / 00831A

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Harley Davidson FL Touring Current Xtreme

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

CRD400 Fitting Inserter OPERATIONS MANUAL

ACCUBALANCE Air Capture Hood Model 8371

OPERATING INSTRUCTIONS AND PARTS LIST

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

SINGLE STICK DIGITAL VOLTMETER

Transcription:

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515 OPERATION AND SERVICE MANUAL P/N 1980571, REVISION D FEBRUARY 2016

Copyright TSI Incorporated / May 2007-2016 / All rights reserved. Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA Fax No. (651) 490-3824 LIMITATION OF WARRANTY AND LIABILITY (effective February 2015) Seller warrants the goods, excluding software, sold hereunder, under normal use and service as described in the operator's manual, to be free from defects in workmanship and material for twenty-four (24) months, or the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment. b. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment. c. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies. d. This warranty does not cover calibration requirements, and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty; f. This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning; g. This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS, BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.

Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call Customer Service department at (800) 874-2811 (USA) or (1) 651-490-2811 (International).

CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION... 1 CHAPTER 2 SETTING-UP... 3 Supplying Power to the Model 7515... 3 Installing the Batteries... 3 Using the Integral Probe... 3 CHAPTER 3 OPERATION... 5 Keypad Functions... 5 CHAPTER 4 MAINTENANCE... 7 Recalibration... 7 Cases... 7 Storage... 7 CHAPTER 5 TROUBLESHOOTING... 9 APPENDIX A SPECIFICATIONS... 11 iii

Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI immediately. 1. Carrying case 2. Instrument 3. Calibration collar 1

(This page intentionally left blank) 2 Chapter 1

Chapter 2 Setting-up Supplying Power to the Model 7515 IAQ-CALC Indoor Air Quality Meter The Model 7515 is powered with four size AA batteries. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Model 7515 is designed to operate with either alkaline or NiMH rechargeable batteries, although it will not recharge NiMH batteries. Battery life will be shorter if NiMH batteries are used. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage. Using the Integral Probe The sensing probe relies on the diffusion of air. For best results, try to keep the sensing probe surrounded by moving air. Do not breathe on the probe. Humans exhale CO 2 levels exceeding 10,000 ppm and it may take time for the probe to re-stabilize. 3

(This page intentionally left blank) 4 Chapter 2

Chapter 3 Operation Keypad Functions ON/OFF Key Sample Key Stats Key CAL Key Press to turn the Model 7515 on and off. During the power up sequence the display will show the following: Model Number, Serial Number, Software Revision, and Last Date Calibrated. Press and release to start the sample, then press the END key to stop the sample. Press to view the minimum, maximum and average of the last sample taken. Press to begin the field-calibration process. To re-calibrate in the field, first connect zero gas to the instrument and open the regulator. The instrument will automatically make zero itself after one minute. After zeroing the sensor, connect span gas to the instrument and open the regulator. The instrument will take one minute to make a reading. Then use the and ENTER keys to adjust the concentration displayed on the instrument to match the concentration on the gas cylinder. 5

(This page intentionally left blank) 6 Chapter 3

Chapter 4 Maintenance The Model 7515 requires very little maintenance to keep it performing well. Recalibration To maintain a high degree of accuracy in your measurements, we recommend that you return your Model 7515 to TSI for annual recalibration. Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization (RMA) number. To fill out an online RMA form, visit TSI s website at http://service.tsi.com. U.S. & International TSI Incorporated 500 Cardigan Road Shoreview MN 55126-3996 Tel: (800) 874-2811 (651) 490-2811 Fax: (651) 490-3824 The Model 7515 can also be recalibrated in the field using the CALIBRATION menu. These field adjustments are intended to make minor changes in calibration to match a user's calibration standards. The field adjustment is NOT intended as a complete calibration capability. For complete, multiple-point calibration and certification, the instrument must be returned to the factory. Cases If the instrument case or storage case needs cleaning, wipe it off with a soft cloth and isopropyl alcohol or a mild detergent. Never immerse the Model 7515. If the enclosure of the Model 7515, it must be replaced immediately to prevent access to hazardous voltage. Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage. 7

(This page intentionally left blank) 8 Chapter 4

Chapter 5 Troubleshooting Table 5-1 lists the symptoms, possible causes, and recommended solutions for common problems encountered with the Model 7515. If your symptom is not listed, or if none of the solutions solves your problem, please contact TSI. Table 5-1: Troubleshooting the Model 7515 Symptom Possible Causes Corrective Action No Display Unit not turned on Switch unit on. Low or dead batteries Replace batteries. Dirty battery contacts Clean the battery contacts. High CO 2 levels Breathing on probe Shield probe from breath and allow instrument to restabilize. Instrument Error message appears Fault in instrument Factory service required on instrument. WARNING! Remove the probe from excessive temperature immediately: excessive heat can damage the sensor. Operating temperature limits can be found in Appendix A, Specifications. 9

(This page intentionally left blank) 10 Chapter 5

Appendix A Specifications Specifications are subject to change without notice. CO 2 : Range: Accuracy 1 : Resolution: Sensor type: 0 to 5000 ppm ±3% of reading or ±50 ppm, whichever is greater 1 ppm Non-Dispersive Infrared (NDIR) Instrument Temperature Range: Operating (Electronics): 40 to 113 F (5 to 45 C) Storage: -4 to 140 F (-20 to 60 C) Instrument Operating Conditions: Altitude up to 4000 meters Relative humidity up to 80% RH, non-condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category II External Meter Dimensions: 3.3 in. 9.6 in. 1.8 in. (8.4 cm 24.4 cm 4.4 cm) Meter Weight: Weight with batteries: 0.6 lbs (0.27 kg) Meter Display Dimensions: Primary display: 4-digit LCD, 0.6 in. (15 mm) digit height Secondary display: 3.5-digit LCD, 0.3 in. (8 mm) digit height Power Requirements: Four AA-size batteries (included) 1 At 77 F (25 C). Add uncertainty of ±0.2%/ F (±0.2%/ C) away from calibrated temperature 11

(This page intentionally left blank) 12 Appendix A

TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 P/N 1980571 Rev D (US) 2016 TSI Incorporated Printed in U.S.A. *1980571*