North Central Texas Wildland Fire Working Group. Regional Response Guidelines

Similar documents
KING COUNTY FIRE MODEL PROCEDURE Section 7 Wildland

Sample Geographic Information System (GIS) Staffing and Response Time Report Virtual County Fire Department GIS Analysis

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

EXAMPLE STANDARD OPERATING PROCEDURE EXPOSURE PREVENTION AND DECONTAMINATION

Program of Instruction Course Syllabus

The following chart shows the NUS minimum stocking levels required for agency engines. Type Category Item Description NFES # 3, 4, & 5 6

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

Procedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November January 2005

North Lyon County Fire Protection District. Seasonal Firefighter Job Description

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 12 Wildland Back Fire Burn Out Revised

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

GREEN SHEET. California Department of Forestry and Fire Protection (CAL FIRE)

Spring Training 2015 Wildland Fire Training

Business Plan We will reflect the National Treasure in which we live

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire

Women in Wildland Fire Boot Camp 2018

GRANDVIEW TOWNSHIP FIRE DEPARTMENT STANDARD OPERATING GUIDELINES. #333 Vehicle Fire Date Issued: 01/01/2014 Date Last Revised: 01/01/2014

Fire Engine Information

Wildland Fire Fighter 2 - NFPA 1051, 2007

Category V. Criterion 5H: Hazardous Materials (Hazmat)

GREEN SHEET. California Department of Forestry and Fire Protection (CAL FIRE)

Rural Water Supply Operations Seminar & Drill

County of Santa Clara Countywide Multi-Hazard / Multi-Disciplinary Task Force (CMTF)

LEVEL 2 DEFENSIVE Standard Equipment Guide

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

RAPID INTERVENTION TEAM STANDARD OPERATING PROCEDURES

Douglas County Transportation & Land Services FLEET MAINTENANCE TECHNICIAN HEAVY EQUIPMENT MECHANIC

West Metro Fire Protection District

Green Monster Fire Engine Super-heavy Tactical Engine (Tatra) BLM Elko, NV Non-Serious Accident Review September 2008

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

Rural VFD Assistance Program Cost Share Rates and Guidelines

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

Driver/Operator Program Part III - Tanker

AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply

SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2009.

Apparatus Replacement Policy

Apparatus Riding Assignments

UNIT CAD CLASSIFICATION DEFINITIONS. Northampton County Emergency Management Services

STANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE

Fire Fighting, Police, and Emergency Equipment 135

Glendale Fire Department

EMERGENCY RESPONSE AND RADIO PROCEDURES

!! Describe different construction types of ground ladders. !! Identify the parts of a ladder including markings and labels.

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

KIT CONTENTS REPORT ICBS. DATE : May 30, :57:58 AM USER ID : PAGE : 1 Report Sorted By : Component Item Description

OPERATIONS IN THE VICINITY OF CATENARY WIRES ON AMTRAK RAILROAD LINES

Basalt Fire Rescue Engine 40 Inspection. Maps (in manila folder) Garmin GPS. Incident organizers Binoculars. Hazmat ERG Assorted pens and legal pad

ESSENTIAL SAFETY RESOURCES

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Wildland Fire Fighter 1 - NFPA 1051, 2007

SCENARIO 16 Overturned MC-331 Cargo Tank Truck

WEST BRIDGEWATER BOARD OF SELECTMEN PUBLIC WORKS LABORER Job Description. Assistant Director of Public Works, Director of Public Works

Fairview Fire District

PAGE 1 OF 6 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S450 Motor Vehicle Safety REV /01/09

EXPEDITION FIRE- BURNED DOZER

U.S. Firefighter Fatalities in Road Vehicle Crashes

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02 5

STANDARD OPERATING GUIDELINES

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY. Policy Subject: Number Page OVERNIGHT RETENTION OF COUNTY VEHICLES D-10 1 of 5

Position Number Community Division/Region Yellowknife North Slave

Dispatching Apparatus and Personnel

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

Presenter s Notes SLIDE 1

===============================================================

Conduct on-road training for motorcycle riders

FIRE ATTACK STRATEGIES

Maintenance and Specifications

Propane 101. Study Guide. Course Code: 8517

Powered Industrial Vehicle Policy

Emergency Decontamination

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C

PROGRAM Regional Board Presentation

Positioning Aerial Apparatus By: Joe Kroboth, III, PE, CFPS Emergency Services Instructor MFRI, Western Maryland Regional Office

Aerial Operations. Name: Frank Ennist

DRIVING & CITY VEHICLES January To identify some rules relevant to use of vehicles; and,

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report

2.3. Priority Responses recognized by the Derby Fire Department will be as follows:

Guidelines For the MITIGATION OF ACCIDENTAL DISCHARGES OF MOTOR VEHICLE FLUIDS (NON-CARGO) APPROVED 6/25/04

FREDERICK POLICE DEPARTMENT GENERAL ORDER

CLEARWATER FIRE & RESCUE TRAINING BUREAU

Water Supply for Suburban and Rural Firefighting, First Edition Final Version December 2012

HEAVY EQUIPMENT WITH WATER Item Description Daily Rate Mobilization/ Demobilization (loaded mile)

ADA Policy Deviated Fixed Route Procedures

Fire Department Access & Water Supply

East Lake Tarpon Special Fire Control District

BERKS COUNTY FIRE/RESCUE, HAZMAT, EMERGENCY MANAGEMENT, & EMS RADIO DESIGNATORS

Emergency Services Guidance for Competition Electric Vehicles

CLEARWATER FIRE & RESCUE TRAINING BUREAU

(1) A one-way trip constitutes one unit of transportation service.

Model Legislation for Autonomous Vehicles (2018)

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.

Portable Ladder Safety

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05

Rural Water Supply Operations Seminar & Drill

PUBLIC Law, Chapter 539 LD 1535, item 1, 124th Maine State Legislature An Act To Create a Smart Grid Policy in the State

Assistance to Firefighter Grant. Grant Example for Road Safety Fire Department

San Ramon Valley Unified School District

Mt. Diablo Unified School District

Transcription:

North Central Texas Wildland Fire Working Group Regional Response Guidelines Purpose These guidelines will outline basic minimum standards for resources being employed during regional response to wildland fire incidents. Scope The Texas Statewide Mutual Aid System (SB11) under Chapter 418 provides the authority for interlocal or regional mutual aid. This does not replace or supersede existing mutual aid agreements or interfere with the ability of municipalities to enter into written mutual aid agreements in the future. It is understood that if a written agreement is entered into by governmental entities or municipalities requesting resources, then the terms of that agreement control the rights and responsibilities of the participating parties to the extent the agreement provides terms that differ from the Texas Statewide Mutual Aid System. These standards are intended to bridge the expectations between local incidents and those requiring state assistance (TIFMAS). These guidelines will be recommended by the North Central Texas Wildland Fire Working Group (NCTWLF) to the Emergency Preparedness Planning Council (EPPC). EPPC will consider and recommend these guidelines for endorsement to North Central Texas Executive Board. The Executive Board will consider and adopt the regional guidelines. Local jurisdictions may consider these regional guidelines when organizing resources, responding to wildfires, and could adopt these guidelines locally. These guidelines constitute a living document. It is expected that with additional response lessons will be learned that will predicate a need to update this document. Therefore, the NCTWLF working group will consider and recommend changes as needed. Summary Wildland fires have the potential to cause catastrophic damage, threaten lives, impose critical infrastructure disruption and impact all sectors of the community. They have the potential to rapidly overwhelm local government capabilities and may quickly deplete resources. When adequately trained and equipped resources are made available quickly, wildland fires have the greatest chance of being successfully contained. This document outlines recommendations regarding the following wildland fire response elements: Firefighting Equipment Firefighter Personal Protective Equipment Firefighter Training and Qualifications Incident Command System

Firefighting Equipment Apparatus ordered for and responding to requests within the region will be categorized based upon the national standard for equipment typing. The following are minimum standards for each engine type: Type 7 Engine (Brush Truck, Attack, Booster, Grass Truck, etc.) 4WD or AWD Tank capacity: 50 gallons Pump capacity: 10 GPM at 100 PSI, with pump and roll capability Hose compliment: 200 of 1 Maximum GVWR: 14000 lbs. Type 6 Engine 4WD or AWD Tank capacity: 150 gallons Maximum GVWR: 19500 lbs. Type 5 Engine Tank capacity: 400 gallons Maximum GVWR: 26000 lbs. Type 4 Engine Tank capacity: 750 gallons Type 3 Engine Tank capacity: 500 gallons Pump capacity: 150 GPM at 250 PSI, with pump and roll capability Hose Compliment: 1000 of 1.5 and 500 of 1 Personnel: 3 It is imperative that wildland fire apparatus be functional and effective in remote, rugged and demanding environments. The following apply to all wildland fire apparatus: Vehicle not to exceed GVWR fully loaded including crew Mobile radio and one portable radio with current statewide interoperability frequencies

Fully functional seat belts for all riding positions Ignition devices: 6-12 fusees/flares or 1 drip torch Minimum of 4 wildland specific handtools (i.e. Pulaski, Fire Shovel, McLeod, Council Rake, Combi-tool, etc.) Mechanic tools and supplies, including appropriate jack, lug wrench and tow strap or chain Container(s) for drinking water (1/2 gallon per person) The following are suggested for wildland fire response: Backpack pump (common eponyms Fedco or Indian Pack) 300 of 5/8 hose (commonly called toy or ribbon hose with garden hose thread couplings) Garden hose barrel nozzle(s) Twin tip (forestry) nozzle(s) with 3/16 th straight bore and 6 gpm spray tips Dual GPM fog nozzle(s), 10/24 or 10/30 1.5 forestry hose clamp(s) 1.5 gated wye(s) 1.5 by 1 reducer(s) 1 by.75 reducer(s) Belt weather kit or Kestrel style electronic weather monitoring device Firefighter Personal Protective Equipment Wildland firefighter clothing and protective equipment is designed specifically to protect firefighters from heat stress, the primary cause of wildland firefighter injuries, in wildland firefighting operations. The following guidelines are adapted from national standards: All personal protective equipment (PPE) will meet or exceed agency policy and should be in compliance with the NFPA 1977, 2011 edition. Wear flame-resistant clothing on the fireline and do not wear clothing, even undergarments, made of synthetic materials, which can burn and melt on your skin. Roll your sleeves down to the wrist. Flame-resistant clothing should be cleaned or replaced whenever soiled, especially when soiled with petroleum products. Flame-resistant clothing will be replaced when the fabric is so worn as to reduce the protection capability of the garment, or is so faded as to significantly reduce the desired visibility qualities. Yellow long-sleeved aramid shirts are recommended. Wear a hard hat and leather gloves while on the fireline. Personnel assigned to wildland fires must wear a minimum of 8-inch-high, laced-type exterior work boots, with Vibram-type, melt-resistant soles. The 8-inch height requirement is measured from the bottom of the heel to the top of the boot. Use eye and face protection whenever there is a danger from material being thrown back in your face. Determine and comply with host agency requirements regarding fire shelters on fireline suppression assignments or follow your own agency s requirements if they are more restrictive. Use hearing protection when working with high-noise-level firefighting equipment, such as helicopters, air tankers, chain saws, pumps, etc.

When operating chain saws, sawyers and swampers will wear additional safety equipment, including approved chaps, gloves, hard hat, and eye and hearing protection. Swampers should wear chaps when the need is demonstrated by a risk analysis considering proximity of the chain saw to the sawyer, and the slope, fuel type, etc. Face and neck protection (Nomex shrouds) are not required PPE. If issued, shrouds should be deployed only in impending flash fuel or high-radiant heat situations and not routinely worn throughout the operational period, due to an unacceptable increase in physiological heat stress. Firefighter Training and Qualifications Fire suppression personnel responding to wildland fire incidents outside local agreements should be trained to national standards. The TIFMAS guidelines require that basic wildland firefighters have the following training: NWCG S130/S190/L180 or, TIFMAS S130/S190/L180 or, SFFMA Wildland Certification completed as of June 2008 with TFS/NWCG or TIFMAS basic wildland or, TCFP Basic Wildland certification In an effort to maintain the highest level of personal effectiveness, and thus the safest and most effective response effort, firefighters participating in operations at the regional level should meet these basic standards. There are two handcrews (Modules) available regionally. The members of these crews exceed the minimum training requirements and are held to a rigorous physical standard. Each module is selfsufficient, and arrives with 8-10 members (minimum of 2 paramedics with ALS gear), chainsaws, drip torches, handtools, and their own sustenance. They are a versatile resource that can be employed in a number of ways: Fire suppression functions such as, constructing handline, conducting burnouts, supporting heavy equipment or engine operations, mop up, and line medics Chainsaw support and assistance with other types of disasters (i.e. tornadoes, ice storms, flood damage, wide area searches, etc.) Assistance with wildland fire training Incident Command System In accordance with the Texas Disaster Act and other applicable provision of law and except as otherwise provided by law, the responsible local official in whose jurisdiction an incident requiring regional mutual aid has occurred shall remain in charge at such incident. Extended Attack (regional response) is the suppression activity for which a wildfire that has not been contained or controlled by initial attack (local mutual aid) forces and for which more firefighting resources are arriving, en route, or being ordered by the Incident Commander. An Extended Attack Incident is the phase of the incident when initial attack capabilities have been exceeded. This transition has a historically high potential for serious accidents and injuries. All planned actions must consider firefighter and public safety as the number one priority. Resources responding to a regional incident

(Extended Attack) should be working under a standard framework of command and control (ICS), and be familiar with the following: Incident Commander or Unified Commander who is responsible for the following: Establish an Incident Command Post (ICP) and check-in location(s) to receive, brief, and assign incoming resources. Determine and document incident objectives. Employ strategy and tactics that will follow the Standard Firefighting Orders, ensure Watch-Out Situations are mitigated, ensure work/rest requirements are met and ensure entrapment situations are avoided. Keep Dispatch or other higher level officers informed of the status of the fire, progress of the suppression effort, additional resources needed, weather conditions and special situations, such as values threatened, etc. Divide the fire into areas of responsibility and assign capable individuals to supervise these areas (i.e. Divisions, Groups, Task Forces and Strike Teams). Operations Chief, whose responsibilities are: Use the risk management process, and supervise operations. Maintain accountability of assigned resources. Brief and assign Operations personnel according to the IAP. Facilitate and coordinate the ordering and release of operation resources. Assemble and disassemble Task Forces/Strike Teams and assigned to operations. Report special activities, events, and occurrences to Incident Commander. Division/Group Supervisor, who is responsible to: Ensure that assigned personnel and equipment get on and off the fireline in a timely and orderly manner. Maintain accountability of assigned resources at all times. Brief and assign specific work tasks to Task Forces/Strike Team Leaders. Coordinate activities with adjacent Divisions. Resolve logistics problems within the Division/Group. Of course, as the incident evolves, many more functional positions may be assigned. Fire personnel should be familiar with ICS and be able to function within this system, regardless how large or complex the incident becomes.